FRM – New Materials and Documents Referenced in the Technical Support Documents
Original sourcePDF at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at source
Other documents for the same rulemaking
References: 729 extracted, 0 linked to papers
UNEP. 2016. Report of the technology and economic assessment panel. Decision XXVII/4 task force report on suitability of alternatives under high ambient temperature (HAT) conditions, United Nations Environment Programme (UNEP), Nairobi, Kenya.
UNEP. 2018. Report of the technology and economic assessment panel. Volume 5: Decision
UNEP. 2019. Report of the technology and economic assessment panel. Volume 3: Decision
UNEP. 2019. Report of the Refrigeration, Air Conditioning and Heat Pumps Technical Options Committee (RTOC), 2018 Assessment. United Nations Environment Programme (UNEP), Nairobi, Kenya.
UNEP. 2020. Montreal Protocol on Substances that Deplete the Ozone Layer, Volume 3: Decision XXX/5 Task Force Final Report on Cost and Availability of Low-GWP Technologies/Equipment that Maintain/Enhance Energy Efficiency. United Nations Environment Programme (UNEP), Nairobi, Kenya.
UNEP. 2022a. The Montreal Protocol on Substances that Deplete the Ozone Layer. Article 2F: Hydrochlorofluorocarbons. https://ozone.unep.org/treaties/montrealprotocol/articles/article-2f-hydrochlorofluorocarbons, Accessed on July 6th, 2022.
UNEP. 2022b. The Montreal Protocol on Substances that Deplete the Ozone Layer. Article 5: Special situation of developing countries. https://ozone.unep.org/treaties/montrealprotocol/articles/article-5-special-situation-developing-countries, Accessed on July 6th, 2022.
Wan, H., Cao, T., Hwang, Y. 2019. A Novel Unitary Air Conditioning System Design for Flammable Refrigerants and Building Ventilation. Proc. 25th IIR Int. Congr. Refrig. Montréal, Canada. 2022 TOC Refrigeration, AC and Heat Pumps Assessment Report
Wan, H., Cao, T., Hwang, Y., Chang, S.-D. 2020. Performance Comparison of Three Refrigerants in a Novel Unitary Air Conditioning System. Proc. 14th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2020). Kyoto, Japan.
Wang, X., Amrane, K. 2016. AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) – Summary of Phase II Testing Results. Proc. 16th Int. Refrig. Air Cond. Conf., Purdue, USA.
Wang, X., Gandhi, P. 2018. A2L Refrigerants Leaks and Ignitions Testing under Whole Room Scale. Proc. 17th Int. Refrig. Air Cond. Conf., Purdue, USA.
Zhang, W., Yang, Z., Li, J., Ren, C-X., Lv, D., Wang, J., Zhang, X., Wu, W. 2013. Research on the flammability hazards of an air conditioner using refrigerant R-290. Int. J. Refrig., Vol. 36, Issue 5, 1483-1494.
Zhou, X. F. 2014. HCFC phase out progress report in RAC sector. Proc. Int. Techn. Conf. Alternative Technology to HCFC-22 in Room Air-conditioner Sector, China Household Electrical Equipment Association (CHEAA), Ningbo, China. 2022 TOC Refrigeration, AC and Heat Pumps Assessment Report Chapter 8 __________________________________________________________ Applied Building Cooling Systems Chapter Lead Author Dennis Dorman Co-authors
ASHRAE (2020) and ARI (1998). 2022 TOC Refrigeration, AC and Heat Pumps Assessment Report A few other general remarks are important. First, water-cooled chillers installed inside the commercial building envelope that provides cooling (and heating) are normally installed in a mechanical equipment room. If installed outdoors, they may be installed in protective enclosures. Very large enterprises, such as the largest high-rise office buildings, health care complexes, or central systems at a university campus can contain a dozen or more chillers, along with boilers, pumps, and air handling units. These mechanical equipment rooms have special features that isolate it from the building occupants, restrict entry to authorized personnel, and have special refrigerant detection, ventilation, and refrigerant venting requirements according to local building code requirements. The use of special mechanical equipment rooms, along with use of a secondary coolant to the units delivering conditioned air to the occupied space provides isolation of the refrigerant from the building occupants.
Eritrea, central India, southern Iran, Iraq, Oman, Pakistan, Kuwait, parts of Saudi Arabia, and southwestern USA. There are other regions that experience HAT conditions, but those regions are sparsely populated. Considering the populated HAT regions, the demand for all refrigeration, air conditioning, and heat pump products is small with less than 4 % of global demand. When considering indirect systems and the chillers used in commercial buildings, the global demand is even less. Table 8-2: High Ambient Rating Conditions In non-HAT countries, systems are normally rated for 35 °C (T1 in ISO 5151:2014) with operation and performance ratings up to 46 °C High ambient temperature (HAT) conditions require a design at 46 °C (T3 in ISO 5151:2014) with operation and performance ratings up to 52 °C Commercial building customers in HAT regions want full capacity products, not products that are designed for other regions and derated for use in HAT countries. This means that a 600kW rated air-cooled chiller delivers 600 kW of cooling operating at T3 conditions. Customers want the product to be optimized at T3 conditions to keep energy cost as low as possible. The product must be reliable in harsh conditions to avoid purchasing redundant equipment. And in time, products must also transition to a refrigerant with lower GWP (other than R-410A or
ACEEE 2010: Performance Comparison of Evaporatively-Cooled Condenser versus AirCooled Condenser Air Conditioners, Faramarzi, R., John Lutton, J., Sean Gouw, S. 2022 TOC Refrigeration, AC and Heat Pumps Assessment Report
Southern California Edison, 2010 ACEEE Summer Study on Energy Efficiency in Buildings.
AHRI. 2020. 2020 Standard for Performance Rating of Water-chilling and Heat Pump Waterheating Packages using the Vapor Compression Cycle, Air Conditioning Heating and Refrigeration Institute, Arlington, Virginia.
ARI.1998. Refrigeration and Air Conditioning, Air-Conditioning and Refrigeration Institute (now the Air-Conditioning, Heating, and Refrigeration Institute), Arlington, Virginia
ASHRAE 2020: 2020 ASHRAE Handbook, HVAC Systems and Equipment (SI Edition),
ASHRAE, Atlanta, GA, USA. ASHRAE Study on Mechanical Joints. VRF Wizard Nov 21, 2018.
Calm, J.M. 2006. Comparative Efficiencies and Implications for GHG Emissions of Chiller
Refrigerants, International Journal of Refrigeration (IJR). 2016b, 29(5):833-841, 2006EN
CARB (California Air Resources Board). 2020. Resolution 20-23, Prohibition on Use of Certain Hydrofluorocarbons in Stationary Refrigeration, Chillers, Aerosols-Propellants, and Foam End Users. https://ww2.arb.ca.gov/rulemaking/2020/hfc2020?utm_medium=email&utm_source=govdeliver Congress.com. 2021. H.R.133 - Consolidated Appropriations Act, 2021. Space https://www.congress.gov/bill/116th-congress/house-bill/133/text Department of Agriculture, Water and the Environment. 2021. Australia Government. Space https://www.environment.gov.au/protection/ozone/rac/new-rules-charging-rac-equipment EN378. 2016. Refrigerating Systems and Heat Pumps – Safety and Environmental
Requirements, A1 2012 Parts 1-4, European Committee for Standardization (Comité Européen de Normalisation, CEN),
Brussels, 2008 EN14825. 2018. Air conditioners, liquid chilling packages and heat pumps, with electrically driven compressors for space heating and cooling - Testing and rating at part load conditions and calculation of seasonal performance, European Committee for Standardization (Comité Européen de Normalisation, CEN), Brussels, 2018
EPA. 2022. Environmental Protection Agency. 40 CFR Part 84 [EPA-HQ-OAR-2021-0643;
FRL-8831-01-OAR] Phasedown of Hydrofluorocarbons: Restrictions on the Use of Certain Hydrofluorocarbons under Subsection the American Innovation and Manufacturing Act of 2020
EUR-Lex. 2014. Regulation (EU) No 517/2014. Space https://eurlex.europa.eu/legalcontent/EN/TXT/?uri=uriserv:OJ.L_.2014.150.01.0195.01.ENG
IEA. 2018. The Future of Cooling, Opportunities for Energy Efficient Air Conditioning International Energy Agency, 15 May 2018
IEC 60335-2-40. 2022. Household and Similar Electrical Appliances - Safety - Part 2-40: Edition 6.0B Particular requirements for electrical heat pumps, air-conditioners and dehumidifiers, International Electrotechnical Commission, 2018
Investigation Unit. 2021; Lihai Building “6-21” General Explosion Accident Investigation
Report, Index No. 11500106MB18895394/2021-00314, People’s Government of Shapingba District, August 2021 Gloёl et al. 2014. JRAIA, 2015 2022 TOC Refrigeration, AC and Heat Pumps Assessment Report Gloёl et al. 2014. JRAIA, 2018 Government of Canada. 2016. Justice Laws Website. Products Containing or Designed to Contain an HFC Used as a Refrigerant. https://laws.justice.gc.ca/eng/regulations/SOR2016-137/page-10.html Japan’s Ministry of Economy, Trade and Industry. 2019. Japan’s Policy on Fluorocarbons Management. MOP31. https://www.jraia.or.jp/english/side/MOP31_02.pdf
Kasahara, H. 2018. Current Status of Japan’s Legislation on F gases and RACHP using LowGWP Refrigerants, The Japan Refrigeration and Air Conditioning Industry Association (JRAIA), July 13, 2018.
Kujak, S., et.al. 2021. A Conversation on Refrigerants, ASHRAE Journal, ASHRAE Journal, March 2021
Montreal Protocol Office. 2018. Refrigerant Landscape – South East Asia. Twinning Workshop on Energy-Efficient and Climate-Friendly Refrigeration and Air
Conditioning, Beijing, China, 11-12 April 2018
National Climate Agency. 2021. Singapore Government Agency Website, Reducing GHG emissions from the use of refrigerants in RAC sector. https://www.nea.gov.sg/ourservices/climate-change-energy-efficiency/climate-change/reducing-ghg-emissions- from-theuse-of-refrigerants-in-rac-sector Öko-Recherche. 2020. Briefing Paper: HFC availability on the EU market, https://ec.europa.eu/clima/sites/clima/files/docs/0106/2020_03_25_hfc_availability_en.
Sharma, S. 2017. Mission Critical Cooling, Sensitivity Factors in Choosing between Air - and Water-Cooled Chillers. ASHRAE Journal, Volume 59, Number 10, October 2017
Taylor, S. 2019. Value-Based HVAC Equipment Selection, ASHRAE Journal, December 2019 Technical Information ART 41, 2005. Du Pont Suva Refrigerants: Technical Reference
Manual, DuPont Turpin, J. 2019. Refrigerant Choices for Chillers Remain Complex, ACHR News, May 6, 2019
UNEP. 2016. The Kigali Amendment to the Montreal Protocol: HFC Phasedown. Space https://www.unep.org/ozonaction/resources/factsheet/kigali-amendment-montreal-protocol-hfcphasedown
UNEP. 2018. Report of the Refrigeration, Air Conditioning and Heat Pump Technical Options Committee, Ozone Secretariat, UNEP, Nairobi, Kenya, February 2019
UNEP. 2019. Report of Workshop for Enabling Activities for HFC Phase down for the Southern African Development Community (SADC) of the Africa Anglophone Network
UNEP. 2014. HFC Policy Analysis Report. UNEP/OzL.Pro.WG.1/34/INF/4/Add.1
UNEP. 2014. Compendium of Policies Governing Hydrofluorocarbons (HFCs).
UNEP/OzL.Pro.WG.1/34/INF/4/Add.2 UL 60335-2-40. 2019. Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirement for Electrical Heat Pumps, Air-Conditioners and
Dehumidifiers, Underwriters Laboratory, November 2019 2022 TOC Refrigeration, AC and Heat Pumps Assessment Report
Williams, P. 2007. Keeping ‘Cool’ in Prison, Engineered Systems Article 92517, February 2007
Wheeler, G, 2019. End-of Life Strategies for HVAC Systems, ASHRAE Journal, December 2019