FRM – New Materials and Documents Referenced in the Technical Support Documents
Original sourcePDF at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at source
Other documents for the same rulemaking
References: 729 extracted, 0 linked to papers
Gluesenkamp, K.R. 2017. “Heat pump clothes dryer.” DOE Building Technologies Office 5th Annual Peer Review, March 13-16, 2017, Arlington, Virginia. https://energy.gov/sites/prod/files/2017/04/f34/6_32226b_Gluesenkamp_0313171630.pdf Gatarić, P. and Lorbek, L. 2021. Evaluating R450A as a drop-in replacement for R134a in household heat pump tumble dryers, Int J Refrig. https://doi.org/10.1016/j.ijrefrig.2021.03.020
IEA. 2021. Achievements of Energy Efficiency Appliance and Equipment Standards and Labelling Programmes: A global assessment in 2021, Paris, France. 2022 TOC Refrigeration, AC and Heat Pumps Assessment Report
IIR. 2015. IIR 29th Informatory Note on Refrigeration Technologies; The Role of Refrigeration in the Global Economy. IIR, Paris, France.
IIR. 2019. IIR 38th Informatory Note on Refrigeration Technologies; The Role of Refrigeration in the Global Economy. IIR, Paris, France.
SEAD. 2019. Global Appliance Testing Costs Catalogue, www.superefficient.org
SEDI. 2012. Potential Energy Savings from Heat Pump Dryers in North America, https://www.energystar.gov/ia/partners/pt_awards/SEDI_Fact_Sheet_H.pdf
TeGrotenhuis, W., Caldwell, D., Butterfield, A., Crook, A. 2016. Affordable Hybrid Heat Pump Clothes Dryer, PNNL-25510, Pacific Northwest National Laboratory, Richland, Washington 99352, USA.
The Economist Intelligence Unit Ltd. 2019. The Cooling Imperative - Forecasting the Size and Source of Future Cooling Demand, London, UK. Topten.eu. 2016. Policy Recommendations for tumble driers, https://www.topten.eu/private/adviser/policy-recommendations-tumble-driers Topten.eu. 2018. Policy Recommendations on Commercial Refrigerated Display Cabinets, https://storage.topten.eu/source/files/Topten_Recommendations_for_Commercial_Refr igerated_Display_Cabinets.pdf
UNE & IIR 2018. Cold Chain Technology Brief – Commercial, Professional and Domestic Refrigeration.
UNEP. 2006. 2006 Report of the Refrigeration, Air Conditioning and Heat Pumps Technical Options Committee, Chapter 3, Domestic Refrigeration.
UNEP, 2018a. Report of the Technology and Economic Assessment Panel, April 2018, Volume 2: Decision XXIX/4 TEAP Task Force Report on Destruction Technologies for Controlled Substances.
UNEP. 2018b. Report of the Technology and Economic Assessment Panel, September 2018: Decision XXIX/10 TEAP Task Force Report on Energy Efficiency. TEAP September 2018: Decision XXIX/10 Task Force Report on issues related to energy efficiency while phasing down hydrofluorocarbons - updated final report (Volume 5) - Advance (unep.org)
UNEP, 2021. Report of the Technology and Economic Assessment Panel, May 2021, Volume 4: Decision XXXI/7 - Continued provision of information on energy-efficient and lowglobal-warming-potential technologies. Von Esebeck, J. and Bush, E. 2018. Household refrigerators and freezers: Recommendations for policy design, Topten International Group. www.topten.eu
Historically, larger sizes of food retail and food service refrigeration applications are prone to significant refrigerant leakage because most of the large systems are field installed with many joints and fittings. In recent years, progress has been made to improve leak tightness, especially for centralized systems, and the effort continues for better refrigerant management during the life of the equipment. The progressing phaseout of HCFC-22 in Article 5 parties, and the phasedown of high-GWP HFCs in many countries, requires making informed choices on the best replacement options. To facilitate this, many industry organizations have conducted and published research into alternative refrigerants that can meet the needs of these applications in a safe and reliable manner. There has been significant development of technology and concepts for using low-GWP R744 (CO2) as refrigerant, especially for larger capacity systems (Hafner, 2018), and low-GWP
AHRI launched a low-GWP Alternative Refrigerant Evaluation Program (AREP) in 2010 (AHRI, 2013). Several new blends based on HFO-1234yf and HFO-1234ze(E) as well as
HFC-134a in this type of equipment. Wherever safety standards are not yet adopted for the use of flammable refrigerants, and wherever it is not possible to design and install R-744 condensing units for cost or building code reasons, choosing a lower GWP A1 refrigerant in place of R-404A or HFC-134a, is always recommended. 5.3.3.2 Low-GWP and lower flammability (A2L) HFC/HFO blends A new set of low-GWP alternative refrigerant blends for HFC-134a, R-404A and HCFC-22 replacement is also being introduced with GWPs ranging from less than 150 to 300, such as R-454A, R-454C, R-455A and R-457A. These are all lower flammability (A2L) refrigerants. Many low-GWP HFC/HFO blends contain HFC-32 and HFO-1234yf and/or HFO-1234ze(E). Tests on these alternative blends reported by Schultz, 2013 show a volumetric capacity either identical or varying in the range of ±5 %, with an efficiency 2 to 7 % lower compared to
HTF secondary loop, leading to better energy efficiency of the low-temperature system and also allowing the use of R-744 in subcritical operation at the low-temperature level. Some other designs are also possible where the condensation heat of the low-temperature system is directly released to the atmosphere. The use of a HTF with phase change offers an energy saving potential: ice slurry for medium temperature or R-744 for medium and low temperatures (Møller, 2003). Through the selection of the correct additive, ice slurry can also outperform a single-phase HTF (Hägg, 2005;
HC-systems is limited; however, charge reduction strategies can help in increasing the number of systems with these flammable refrigerants. 5.4.3.4 Ultralow-GWP R-717 Due to its toxicity, R-717 is confined in a ventilated machinery room and R-717 systems are always designed with secondary loops, indirect systems, at each temperature level. Several large supermarkets operate with R-717 especially in Luxembourg and Switzerland. R-717 can be used in indirect systems at the medium-temperature level, and also cascaded together with R-744 at the low-temperature level. Research into low-charge R-717 systems are also underway in Europe and North America. 5.4.3.5 Ultralow-GWP R-744 The real breakthrough in using R-744 as a refrigerant began around 2005 with two major new options: R-744 as the only refrigerant in booster systems and R-744 in cascade systems along with HFCs or other refrigerants. For using R-744 as the only refrigerant in small, medium, and large size supermarkets, R-744 has been introduced in transcritical booster systems (Figure 5-4). In 2021, more than 40,000 transcritical R-744 systems of different sizes have been installed, mainly in Europe (85 %) (Koegelenberg, 2021)). Due to the widespread use of R-744 in Europe and growing use in North America, the cost of systems has been significantly reduced and now compete with
HFC gases in all applications. The commonly used HFCs in existing food retail and food service are R-404A and HFC-134a and in many Article 5 parties HCFC-22 is also used. Ultralow-, low- and medium-GWP alternatives for these refrigerants are now available in the European Union and North 2022 TOC Refrigeration, AC and Heat Pumps Assessment Report American markets and we can expect these to grow in Article 5 parties as well, as refrigerants and components become readily available. Non-halocarbon refrigerants such as R-744 are increasingly being used in food retail systems worldwide – both in cascaded systems (R-744 for low side cascaded with a second refrigerant like HFC-134a, R-450A, R513A, HFO-1234ze, or R-717 and HC-290 in limited cases) and in transcritical all-R-744 systems. Transcritical systems are being modified extensively to reduce their energy penalty at high ambient conditions with different component and system technologies. R-744 is also beginning to see its use in food service applications with condensing units. Commercial stand-alone systems, which are commonly used in food retail and food service establishments, have for the most part transitioned to HC-290, with some exceptions where the properties of the halocarbon blends are needed for achieving performance (covered in Chapter 4).
AIRAH. 2015. https://www.airah.org.au/Content_Files/Resources/Trial-Retrofit-of-Doors-onOpen-Refrigerated-Display-Cabinets.pdf
AHRI. 2013. Low-GWP Alternative Refrigerant Evaluation Program http://www.ahrinet.org/site/514/Resources/Research/AHRI-Low-GWP-AlternativeRefrigerants-Evaluation
AHRI. 2014. http://www.ahrinet.org/Resources/Research/AHRI-Low-GWP-AlternativeRefrigerants-Evaluation-Program/AHRI-Low-GWP-AREP-Conference
AHRI 1250. 2014. AHRI Standard 1250 (I-P) 2014 Standard for Performance Rating of Walk-in Coolers and Freezers. http://www.ahrinet.org/App_Content/ahri/files/standards%20pdfs/AHRI%20standards %20pdfs/AHRI_1250_(I-P)-2014.pdf"
ASHRAE. 2016. https://www.ashrae.org/about/news/2016/ashrae-ahri-doe-partner-to-fundflammable-refrigerant-research
Chasserot, M. 2013. Natural Refrigerants Market Trends; Bangkok Technology conference June 30, 2013
Dallinger, J., Sheehan, J. 2012. Supermarktkälteanlage mit CO2 als Kälteträger – Fallstudie einer Anlage in Australien. DKV Tagung 2012, Würzburg, Germany de Larminat, P. 2018. “An overview of lower GWP blend for the food cold chain.” Paper ID72. 5th IIR Conference on Sustainability and the Cold Chain, Beijing China, April 2018.
Dickes, R. and Winaday, E. 2022. CO2 Scroll Compressor with Dynamic Vapor Injection integrated into Transcritical Refrigeration Systems – a theoretical assessment, Proceedings of the 15the IIR – Gustav Lorentzen Conf. on Natural Refrigerants, GL2022, Trondheim, Int. Inst. of Refrigeration, 10.18462/iir.gl2022.0149
Eckert, M., Kauffeld, M; Siegismund, V. et al. 2022. Natural Refrigerants: Applications and
Emerson. 2021. https://e360hub.emerson.com/webinars/preparing-for-the-safe-use-of-a2lrefrigerants-in-commercial-refrigeration
EPA. 2010. US-EPA: Transitioning to low-GWP alternatives in commercial refrigeration. Fact sheet, October 2010
EPA. 2014. http://www2.epa.gov/greenchill/reports-guidelines-and-tools
EPA. 2022. https://www.epa.gov/system/files/documents/2022-09/GreenChill-Keeping-Coolfor-15-Years-2022_1.pdf
EPA. Dec 2022. https://www.epa.gov/climate-hfcs-reduction/technology-transitions
Finckh, O., Schrey, R., Wozny, M. 2011. Energy and efficiency comparison between standardized HFC and CO2 transcritical systems for supermarket applications. IIR Int. Congr. Refr. August 21 – 26, 2011, Prague, Czech Republic
Gao, K., Purohit, N., Becerra, E.V., Vogl, R., Sethi, A., and Hulse, R. 2022. Performance Evaluation Of R471A In Refrigerated Display Cabinet And Walk-In-Cooler. 2022 International Refrigeration and Air Conditioning Conference. Paper 2490. https://docs.lib.purdue.edu/iracc/2490 2022 TOC Refrigeration, AC and Heat Pumps Assessment Report
Garry, M. 2018. Hydrocarbons21.com. Available at: http://hydrocarbons21.com/articles/8122/emerson_unveils_first_propane_condensing_u nits
Gullo, P., Hafner, A., Banasiak, K., Minetto, S. 2018. A review of recent technological advancements in multi-ejector concepts, Proceedings of the 13th IIR-Gustav Lorentzen Conference on Natural Refrigerants, GL2018, International Institute of Refrigeration,
DOI: 10.18462/iir.gl.2018.1358 Hägg, C. 2005. Ice Slurry as secondary fluid in refrigeration systems. KTH Stockholm,
Schweden, ISBN 91-7178-192-7 Huff, H., Finckh, O., Verma, P., Liu H. 2012. Viable solutions to increase efficiencies of transcritical CO2 systems for commercial refrigeration. IIR Gustav Lorentzen
Conference, June 25-27, 2012, Delft, The Netherlands
Hafner, A., Claussen, I.C., Schmidt, F., Olsson, R., et al. 2014a. Efficient and integrated energy systems for supermarkets, Proceedings of the 11th IIR-Gustav Lorentzen Conference on Natural Refrigerants, GL2014, International Institute of Refrigeration,
ISBN 978-2-36215-004-3. Hafner, A., Nekså, P. 2014b. System configurations for supermarkets in warm climates applying R-744 refrigeration technologies. Case studies for selected cities. International Special Issue 2014 - United Nations Environment Programme, International Institute of
Refrigeration, Centro Studi Galileo, Associazione dei Tecnici del Freddo, European Energy Centre, Casale M.to, Italy, 2014
Hafner, A., Nekså, P. 2018. Integrated CO2 solutions for supermarkets, Proceedings of the 13th IIR-Gustav Lorentzen Conference on Natural Refrigerants, GL2018, International Institute of Refrigeration, 10.18462/iir.gl.2018.1002 Hydrocarbons21. 2016. http://hydrocarbons21.com/articles/7026/cocacola_to_allow_hydrocarbons_in_smaller_cooler_equipment
Karve, N., Velde, K van de, Vandaele, S. 2022. Energy efficiency of an integrated refrigeration and air-conditioning system using test and site measurements, Proceedings of the 15the IIR – Gustav Lorentzen Conf. on Natural Refrigerants, GL2022,
Kauffeld, M. 2013. Trends and perspectives in supermarket refrigeration In GTZ Proklima
Yearbook, 2008, p. 161-172 Kauffeld, M. 2015. Current and Future Carbon-saving Options for Retail Refrigeration. In Sustainable Retail Refrigeration Editors: Evans, J. und Foster, A.M., Wiley-Blackwell; 1. edition (11 Dec. 2015), ISBN 978-0-470-65940-3
Koegelenberg, I., Garry, M. 2021. ATMOsphere Natural Refrigerants Market Forecast (20212030), https://atmosphere.cool/product/natural-refrigerants-market-forecast-2021edition/ September 2021
Lagrabette, O. 2005. Kältetechnik im Einzelhandel – Carrefour setzt auf die “grünen” Medien. KKA 1 (2005), S. 20 – 24
Minetto, S., Girotto, S., Rossetti, A., Marinetti, S., Tosato, G. 2018. A new approach to performance data harvesting and processing in commercial refrigeration systems, Proceedings of the 13th IIR-Gustav Lorentzen Conference on Natural Refrigerants, GL2018, International Institute of Refrigeration, 10.18462/iir.gl.2018.1147 Møller, J.B. 2003. CO2 is keeping Supermarkets Cool. The NEWS. 8. 12. 2003 2022 TOC Refrigeration, AC and Heat Pumps Assessment Report