FRM – New Materials and Documents Referenced in the Technical Support Documents
Original sourcePDF at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at source
Other documents for the same rulemaking
References: 729 extracted, 0 linked to papers
Nielsen O. J., Scott B. F., Spencer C., Wallington T. J., Ball J. C. 2001. Trifluoroacetic acid in ancient freshwater, 2001. Atmospheric Environment, Volume 35, Issue 16, 2001. Pages 2799-2801, ISSN 1352-2310, https://doi.org/10.1016/S1352-2310(01)00148-0.
Nix, E. 2018. How Fast is the World’s Population Growing? Elizabeth Nix on the History Channel. Retrieved from: https://www.history.com/news/how-fast-is-the-worldspopulation-growing. 22 August 2018.
Poore, J., & Nemecek, T. 2018. Reducing food’s environmental impacts through producers and consumers. Science, 360(6392), 987-992.
Ricci, P.F., Sheng, H. 2013. Benefits and Limitations of the Precautionary Principle. Encyclopaedia of Environmental Health, 2011, OPP 276-285. Published by Elsevier.
Rio. 1992. https://www.un.org/en/development/desa/population/migration/generalassembly/docs/g lobalcompact/A_CONF.151_26_Vol.I_Declaration.pdf.
Ritchie, H., Roser, M., and Rosado, P. 2020. "CO₂ and Greenhouse Gas Emissions". Retrieved from: https://ourworldindata.org/co2-and-other-greenhouse-gas-emissions University of Oxford. 2020 Rüdel, H., Wolfgang Körner, Thomas Letzel, Michael Neumann, Karsten Nödler, Thorsten
Reemtsma. 2020. Persistent, mobile and toxic substances in the environment: a spotlight on current research and regulatory activities, Environmental Sciences
UNEP. 2022. “As it Bakes, Egypt Looks to the Cooling Power of the Sea for Help. Retrieved from: https://www.unep.org/news-and-stories/story/it-bakes-egypt-looks-coolingpower-sea-help. 17 May 2022.
VDI. 2017. Evaluation of sustainability, VDI Guidelines, Oct. 2017.
WHO. 2022. World Health Organization. Food Safety. Retrieved from: https://www.who.int/news-room/fact-sheets/detail/food-safety. 19 May 2022
WMO. 2022. World Meteorological Organization (WMO), Scientific Assessment of Ozone Depletion: 2022, World Meteorological Organization, GAW Report No. 278, Geneva,
Switzerland, 2022, ISBN 978-9914-733-97-6. https://ozone.unep.org/sites/default/files/2023-02/Scientific-Assessment-of-OzoneDepletion-2022.pdf 2022 TOC Refrigeration, AC and Heat Pumps Assessment Report
UV treatment of (recirculated) air 2022 TOC Refrigeration, AC and Heat Pumps Assessment Report Chapter 3 __________________________________________________________ Refrigerants Chapter Lead Authors Asbjørn Vonsild Lambert Kuijpers Co-authors
HC-290, particularly in low-charge hermetically sealed applications such as refrigerators and small appliances), ammonia (R-717) and R-744 in industrial uses, and water in vapour-compression cycles for specialized applications such as desalination and deepmine chillers, gradually also for smaller sized turbo-units for cooling (e.g., for data centres). 2010-onwards – refrigerants with zero or near-zero ODP and very low global-warming potential (GWP), such as “natural refrigerants” and unsaturated synthetic chemicals. 2022 TOC Refrigeration, AC and Heat Pumps Assessment Report Hence also significant pursuit of unsaturated halochemicals including hydrochloro-olefins (HCOs), hydrochlorofluoro-olefins (HCFOs), and hydrofluoro-olefins (HFOs). The olefinic double bond between two carbon atoms leads to atmospheric instability and, in turn, a very short atmospheric lifetime. The result is near-zero ODP predicated on the decomposition before rising to the stratosphere and likewise very low GWP again by atmospheric decomposition in the troposphere. Examples include HFO-1234yf for mobile air conditioner use, HFO-1234ze(E) and HCFO-1233zd(E) for (centrifugal) chillers, and
HFO-1336mzz(Z) and HFO-1336mzz(E) gaining acceptance as blend components in addition to other refrigerants addressed below. The use of HCOs, HCFOs, and HFOs remains controversial as some parties deem them still of concern based on secondary chemistry of these chlorine- and fluorine-containing substances yielding longer-lived greenhouse gases (GHGs) or ozone-depleting substances. Likewise, there is potential to form such environmentally persistent chemicals as trifluoro-acetic acid (TFA). See further section 3.4.2. Another chemical group being pursued consists of the fluoro-iodocarbons, notably FIC-13I1 (CF3I). Proponents advocated their use in the late 1980s and 1990s, and
GWP is taken. However, some experts advocate the use of GWP values with shorter integration time horizons, particularly in the case of HFCs which often have relatively short lifetimes. They also emphasise the use of various instantaneous or sustained metrics such as the global temperature potential (GTP) (Shine et al., 2005; Hodnebrog et al., 2013) See also section 8.7 of the IPCC (2013) AR5 WGI report for a detailed discussion of the pulse GTP and sustained GTP. The GWP parameter is not directly related to sustainability. It is actually the policy choice of a certain GWP (with a certain ITH) that could lead to more or less sustainability in the operation of equipment with certain refrigerants. Although new concepts have recently been proposed (such as the GWP* which adds extra emissions in case of the consideration of shortlived compounds compared to CO2), this has so far not been considered for refrigerants. There is also an effect on the GWP related to the carbon cycle feedback, i.e., the climate impact would change in a warming world; for this reason, GWPs including the carbon cycle feedback have been published in the IPCC AR6 (2021). This is a correction to the calculation of the
GWP is that this GWP is more commonly used — in scientific literature, standards, and regulations — which is important to an efficient discussion of the climate impact. 2022 TOC Refrigeration, AC and Heat Pumps Assessment Report A classification of 100-year GWPs (which is identical to the classification in the previous
RTOC reports ((UNEP, 2015) and (UNEP, 2019)) is given in Table 3-1. Table 3-1 categorizes using “less than” or “more than” and therefore a refrigerant such as HFO-1234yf is included in the ultra-low, very low, and low GWP groups. Likewise, HFC-23 is included in the ultrahigh, very high, and high GWP groups. The values in the table are not an attempt to match any “cut-off” values in legislation, which are often set based on the GWP of alternatives deemed viable at the time of writing of the specific legislation, and they are normally based on a specific publication that includes lists of
Typically, for “off the shelf” RACHP systems, the manufacturer will have selected the refrigerant, whereas for bespoke systems, selections may be carried out by the designer, installer and/or service company. Industry organisations, such as AEM, SAE, AHRI, etc., conduct screening projects to understand how new refrigerants will meet user needs. Data are shared through industry consortiums to support users who are making refrigerant selections. 2022 TOC Refrigeration, AC and Heat Pumps Assessment Report Environmental legal obligations Legislation prohibits the use of certain refrigerants and in some cases the use for particular equipment and applications. This includes regulations covering fluids with an ozone depletion potential, but also GWPs above certain threshold values, although other environmental impacts may also apply in some countries. Safety requirements
Typically, users select refrigerants that are compatible with existing system requirements. Refrigerants that require new system design face other technical challenges but can still be successfully employed. One example of system architecture change is noted when going from R-404A to CO2 (R-744) in large commercial refrigeration applications. Refrigerants and safety standards The framework of RACHP sector safety standards relies upon an alpha-numeric refrigerant safety classification (A1, B3, etc.) and safety limits (lower flammability limit (LFL), acute toxicity exposure limit (ATEL), etc.). Therefore, it is desirable that refrigerants be listed in the applicable classification and numbering standards, such as ISO 817 (ISO 817:2014) and
ASHRAE Standard 34 (ASHRAE 34-2022), and amendments/addenda thereof.11
RACHP industry. CEN TR 17608:2022 (CEN, 2022) gives an overview of the state of the art of safety standards related to flammable refrigerants. Further discussion can be found in the TEAP XXVIII/4 Task Force report (UNEP, 2017a) and an overview from this report concerning the scope of different international standards is provided in Table 3-3. However, many countries adopt international standards but add specific national deviations or publish their own standards equivalent to those in Table 3-3.
Therefore, it is pertinent to refer to national standards as applicable. An overview of current safety standards is maintained by the Ozone Secretariat and can be accessed at: https://ozone.unep.org/system-safety-standards Briefing notes have been provided by UNEP: a) Safety standards relevant to Refrigeration, Air-Conditioning and Heat Pump equipment (UNEP, 2017b) b) Updating the refrigeration, air-conditioning and heat pump (RACHP) safety standards (UNEP, 2017c) c) Application of safety standards to Refrigeration, Air-Conditioning and Heat Pump equipment – a lifetime perspective (UNEP, 2017d) 2022 TOC Refrigeration, AC and Heat Pumps Assessment Report Table 3-3: Scope of different international and regional safety standards for R/AC&HP systems from the TF XXVIII/4 report (UNEP, 2017a) Sector Product safety standards Group safety standard
AHRI 8028. 2021. A2L Refrigerants and firefighter tactical considerations. https://www.ahrinet.org/App_Content/ahri/files/RESEARCH/Technical%20Results/A
HRI-8028_Final_Report.pdf AHRTI 9007-01. 2017, Pravinray Gandhi, George Hunter, Randall Haseman, Brian Rodgers, Benchmarking Risk by Whole Room Scale Leaks and Ignitions Testing of A2L Refrigerants. https://www.ahrinet.org/App_Content/ahri/files/RESEARCH/Technical%20Results/A HRI_9007-01_Final_Report.pdf
ANSI/ASHRAE Standard 34-2022 with addenda ac and ah, Designation and Safety Classification of Refrigerants American Society of Heating, Refrigerating, and AirConditioning Engineers (ASHRAE), Atlanta, GA, USA
Barrault, S., Saba, S., Clodic, D, Nemer, M. 2013. Refrigerant inventories and emissions platform. Proceedings Papiernicka Compressor Conference, September 2013, https://www.researchgate.net/publication/276204059 (also available from IIR Fridoc)
Calm, J. M. 2012. “Refrigerant Transitions ... Again” (keynote). Moving Towards Sustainability (Proceedings of the ASHRAE/NIST Conference), American Society of Heating Refrigerating, and Air-Conditioning Engineers (ASHRAE), 2012, Atlanta, GA,
USA. Calm, J. M., Didion, D. A. 1997. Trade-Offs in Refrigerant Selections — Past, Present, and Future. Proc. ASHRAE/NIST Conf. ‘Refrigerants for the 21st Century’, American Society of Heating Refrigerating, and Air-Conditioning Engineers (ASHRAE), Atlanta,
GA, USA republished 1998. International Journal of Refrigeration, 21(4)308-321.
Calm, J. M., Didion, D. A. 1997. Trade-Offs in Refrigerant Selections — Past, Present, and Future. Refrigerants for the 21st Century. Proceedings of the ASHRAE/NIST Conference. American Society of Heating Refrigerating, and Air-Conditioning Engineers (ASHRAE), Atlanta, GA, USA, 19 June 1997; republished 1998. International Journal of Refrigeration, 21(4):308-321.
CEN. 2022. CEN TR 17608:2022. State of the art on the use of flammable refrigerant alternatives, in particular from class A3, in refrigeration, air conditioning and heat pump equipment. 2022 TOC Refrigeration, AC and Heat Pumps Assessment Report
Clodic, D., Barrault, S. 2011. 1990-2010 Refrigerant Inventories for Europe, Previsions on banks and Emissions from 2006 to 2030 for the European Union, Final Report Armines
CEP Paris and ERIE EEAP, 2022. Environmental Effects and Interactions of Stratospheric Ozone Depletion, UV
UNEP Nairobi, 2023 (see S. Madronich et al., Section 6.3, Trifluoroacetic acid in the global environment with relevance to the Montreal Protocol)
EPA. 2022. https://www.epa.gov/sites/default/files/2016-10/documents/hydrogenfluoride.pdf, last accessed January 2022
Federal Register. 1995. Federal Register / Vol. 60, No. 113 / Tuesday, June 13, 1995 / page 31099, https://www.govinfo.gov/content/pkg/FR-1995-06-13/pdf/95-14337.pdf
Federal Register. 1999. Federal Register / Vol. 64, No. 233 / Monday, December 6, 1999 / page 68040, https://www.govinfo.gov/content/pkg/FR-1999-12-06/pdf/99-31544.pdf
Simcik, M. F. 1994. Partitioning and Accumulation of Perfluoroalkyl Substances in Model Lipid Bilayers and Bacteria. Environ. Sci. Technol. 2018, 52 (18), 10433−10440.
George, C., Saison, J.Y., Ponche, J.L., Mirabel, P. 1994. Kinetics of Mass Transfer of Carbonyl Fluoride, Trifluoroacetyl Fluoride, and Trifluoroacetyl Chloride at the Air/Water Interface. J. Phys. Chem. pp 10857-10862, Vol. 98. 1994
HFC Outlook. 2021. https://www.ozonactionmeetings.org/system/files/flyer_epeeunep_hfc_outlook.pdf
Holland R., Khan M. A. H., Driscoll I., Chhantyal-Pun R., Derwent R. G., Taatjes C. A., OrrEwing A. J., Percival C. J., Shallcross D. E. 2021. Investigation of the Production of Trifluoroacetic Acid from Two Halocarbons, HFC-134a and HFO-1234yf and Its Fates Using a Global Three-Dimensional Chemical Transport Model. ACS Earth Space
Hunter, G, 2021. A2L Refrigerants and Firefighter Tactical Considerations. March, 2021, https://www.ahrinet.org/App_Content/ahri/files/RESEARCH/Technical%20Results/A
HRI-8028_Final_Report.pdf IPCC/TEAP, 2005. Metz, B., Kuijpers, L., Solomon, S., Andersen, S.O., Davidson, O., Pons, J., De Jager, D., Kestin, T., Manning, M., Meyer, L. (eds). Published by (IPCC) Cambridge University Press, UK. pp 478. Available from Cambridge University Press, The Edinburgh Building Shaftesbury Road, Cambridge CB2 2RU ENGLAND. ISBN: 978-0-521-86336-0
IPCC-TEAP. 2005a. Supplementary information to the IPCC/TEAP material (containing tables on demand, banks and emissions)
IPCC. 2007. Fourth Assessment Report WGI. AR4 Climate Change 2007: The Physical Science Basis. https://www.ipcc.ch/report/ar4/wg1/
IPCC. 2013. Fifth Assessment Report WGI. Climate Change 2013: The Physical Science Basis. https://www.ipcc.ch/report/ar5/wg1/
IPCC. 2021. Sixth Assessment Report WGI. AR6 Climate Change 2022: The Physical Science Basis. https://www.ipcc.ch/report/ar6/wg1/
ISO 5149:2014. Refrigerating systems and heat pumps — Safety and environmental requirements. International Organization for Standardization (ISO) 2022 TOC Refrigeration, AC and Heat Pumps Assessment Report
ISO 817:2014 with Amendment 1 and Amendment 2. Refrigerants — Designation and safety classification. International Organization for Standardization (ISO)