MCCEM, see Appendix A) Emission Factor (ug/m2/hr) Saturation Concentration in Air (mg/m3) 1.89E+05 Based on chemical properties and estimated within Stay at home3 Default (U.S. EPA, 2019a, b) Use Start Time 9 AM4 Frequency of Use 1 event per day Defaults (U.S. EPA, 2019a, b) Acute Exposure Duration 1 day Use Patterns and Receptor Activity Exposure Factors Pattern Page 37 of 93 Acute Averaging Time 1 day Chronic Exposure Duration 57 years Chronic Averaging 78 years Time Surface Area to
ATSDR. (2012). Toxicological profile for 1,4 dioxane [ATSDR Tox Profile]. Atlanta, GA: U.S. Department of Health and Human Services, Public Health Service. http://www.atsdr.cdc.gov/toxprofiles/tp.asp?id=955&tid=199
Canada, H. (2010). Screening assessment for the challenge: 1,4-Dioxane. Environment Canada, Health Canada. http://www.ec.gc.ca/ese-ees/789BC96E-F970-44A7-B306-3E32419255A6/batch7_12391-1_en.pdf
ECJRC. (2002). European Union risk assessment report: 1,4-dioxane. In 2nd Priority List. (EUR 19833
EPA, D. (2018a). Survey and risk assessment of chemical substances in chemical products used for "doit-yourself" projects in the home. (167).
EPA, D. (2019a). Danish surveys on chemicals in consumer products. Ministry of Environment and Food of Denmark. https://eng.mst.dk/chemicals/chemicals-in-products/consumers-consumerproducts/danish-surveys-on-consumer-products/
EPA, US. (2010). Multi-chamber concentration and exposure model (MCCEM) version 1.2 [Website]. https://www.epa.gov/tsca-screening-tools/multi-chamber-concentration-and-exposure-modelmccem-version-12
EPA, US. (2015). Evaluation of Swimmer Exposures Using the SWIMODEL Algorithms and Assumptions. https://www.epa.gov/sites/production/files/201611/documents/swimodel_final.pdf
EPA, US. (2017). Scope of the risk evaluation for 1,4-dioxane. CASRN: 123-91-1 [EPA Report]. (EPA740-R1-7003). https://www.epa.gov/sites/production/files/201706/documents/dioxane_scope_06-22-2017.pdf
EPA, US. (2018b). Problem formulation of the risk evaluation for 1,4-dioxane. (EPA-740-R1-7012).
EPA, US. (2018c). Problem formulation of the risk evaluation for perchloroethylene (ethene, 1,1,2,2tetrachloro). (EPA-740-R1-7017). Washington, DC: Office of Chemical Safety and Pollution
Prevention, United States Environmental Protection Agency. https://www.epa.gov/sites/production/files/2018-06/documents/perc_problem_formulation_5-312018v3.pdf
EPA, US. (2019b). Exposure factors Handbook 2019 Update. https://cfpub.epa.gov/ncea/risk/recordisplay.cfm?deid=340635
EPA, US. (2019c). Multi-Chamber Concentration and Exposure Model (MCCEM) User Guide. U.S.
FDA. (2007). 1,4-Dioxane- A manufacturing byproduct. Silver Spring, MD: Food and Drug Administration. http://www.fda.gov/cosmetics/productsingredients/potentialcontaminants/ucm101566.htm
Frasch, HF; Bunge, AL. (2015). The transient dermal exposure II: post-exposure absorption and evaporation of volatile compounds. J Pharm Sci 104: 1499-1507. http://dx.doi.org/10.1002/jps.24334
Isaacs, K. (2014). The consolidated human activity database - master version (CHAD-Master) technical memorandum. Washington, DC: U.S. Environmental Protection Agency, National Exposure Research Laboratory. https://www.epa.gov/sites/production/files/201502/documents/chadmaster_091814_1.pdf Page 79 of 93
Fukushima, S. (2009). Carcinogenicity studies of 1,4-dioxane administered in drinking-water to rats and mice for 2 years. Food Chem Toxicol 47: 2776-2784. https://heronet.epa.gov/heronet/index.cfm/reference/download/reference_id/594539
Karlovich, B; Thompson, C; Lambach, J. (2011). A Proposed Methodology for Development of Building Re-Occupancy Guidelines Following Installation of Spray Polyurethane Foam Insulation - Revision. Pittsburgh, PA: Bayer Material Science. https://www.pharosproject.net/uploads/files/sources/1221/5be64ae6180cb64590e6b7db69d2666c 1f5d702f.pdf
Fukushima, S. (2009). Two-year inhalation study of carcinogenicity and chronic toxicity of 1,4dioxane in male rats. Inhal Toxicol 21: 889-897. https://heronet.epa.gov/heronet/index.cfm/reference/download/reference_id/193803
Kociba, RJ; Mccollister, SB; Park, C; Torkelson, TR; Gehring, PJ. (1974). 1,4-dioxane. I. Results of a 2year ingestion study in rats. Toxicol Appl Pharmacol 30: 275-286. http://dx.doi.org/10.1016/0041-008X(74)90099-4
Mattie, DR; Bucher, TW; Carter, AL; Stoffregen, DE; Reboulet, JE. (2012). Acute Inhalation Toxicity Study of 1, 4-Dioxane in Rats (Rattus norvegicus). GRA and I: 29.
Naldzhiev, D; Mumovic, D; Strlic, M. (2019). An experimental study of spray foam insulation productsevidence of 1,2-dichloropropane and 1,4-dioxane emissions. IOP Conference Series: Materials Science and Engineering 609: 042053. http://dx.doi.org/10.1088/1757-899X/609/4/042053
Nekoomaram, J; Wieroniey, S. (2015). Comment submitted by Javaneh Nekoomaram, Counsel, Government Affairs and Stephen Wieroniey, Director, Occupational Health and Product Safety, American Coatings Association (ACA). https://www.regulations.gov/document?D=EPA-HQOPPT-2015-0078-0007
Poppendieck, D; Schlegel, M; Connor, A; Blickley, A. (2017). Flame retardant emissions from spray polyurethane foam insulation [Author's manuscript]. J Occup Environ Hyg 14: 681–693.
Poppendieck, DGoMEmS. (2017). Characterization of Emissions from Spray Polyurethane Foam: Final Report to U.S. Consumer Product Safety Commission. (NIST Technical Note 1921). National Institute of Standards and Technology. https://doi.org/10.6028/NIST.TN.1921 U.S.
Census Bureau. (2015). Statistics of U.S. Businesses (SUSB). https://www.census.gov/data/tables/2015/econ/susb/2015-susb-annual.html U.S.
EPA. (2002). A review of the reference dose and reference concentration processes (pp. 1-192). (EPA/630/P-02/002F). Washington, DC: U.S. Environmental Protection Agency, Risk Assessment Forum. http://www.epa.gov/osa/review-reference-dose-and-reference-concentrationprocesses U.S.
EPA. (2011). Exposure factors handbook: 2011 edition (final) [EPA Report]. (EPA/600/R090/052F). Washington, DC: U.S. Environmental Protection Agency, Office of Research and
EPA. (2015). TSCA work plan chemical problem formulation and initial assessment. 1,4-Dioxane. (740-R1-5003). Washington, DC: Environmental Protection Agency, Office of Chemical Safety and Pollution Prevention. http://nepis.epa.gov/Exe/ZyPURL.cgi?Dockey=P100MDC1.TXT U.S.
EPA. (2017a). 1,4‐dioxane (CASRN: 123‐91‐1) bibliography: Supplemental file for the TSCA Scope Document [EPA Report]. https://www.epa.gov/sites/production/files/201706/documents/14dioxane_comp_bib.pdf Page 80 of 93 U.S.
EPA. (2017b). Consumer Exposure Model (CEM) version 2.0: User guide. U.S. Environmental Protection Agency, Office of Pollution Prevention and Toxics. https://www.epa.gov/sites/production/files/2017-06/documents/cem_2.0_user_guide.pdf U.S.
EPA. (2018). Application of systematic review in TSCA risk evaluations. (740-P1-8001).
EPA. (2019a). Consumer Exposure Model (CEM) 2.1 User Guide. (EPA Contract # EP-W-12010). Washington, DC.
EPA. (2019b). Consumer Exposure Model (CEM) 2.1 User Guide - Appendices. (EPA Contract #
EP-W-12-010). Washington, DC. Won, DNoGYaWCoP. (2014). Material Emissions Testing: VOCs from Wood, Paint, and Insulation Materials. National Research Council of Canada. http://dx.doi.org/https://doi.org/10.4224/23002015 Page 81 of 93
However, the SPF scenario is better modeled by a single decay constant after application. 𝐸𝑅(𝑡) = 𝑀 × 𝑊𝐹 × 𝐶𝐹 × [(1 − 𝑒 −𝑘(𝑡−𝑡𝑠𝑡𝑎𝑟𝑡 ) ) − ((1 − 𝑒 −𝑘(𝑡−(𝑡𝑠𝑡𝑎𝑟𝑡 +𝑡𝑎)) ) × 𝐻(𝑡))] Where: 𝐸𝑅(𝑡) 𝑡𝑠𝑡𝑎𝑟𝑡 𝐻(𝑡) The incremental model can be populated using experimental data and proposed model of emission rates in Karlovich et al. (2011). In this study, the authors measured air concentrations of 1,4-dioxane after taking samples from an open-cell SPF product applied to a cardboard box and placed in a small-scale environmental chamber. These concentrations were used to develop a mathematical relationship between the emission factor and loading factor based on the volume and airflow of the chamber. Emission rate at time 𝑡 (mg/min) Mass of product used (g) Weight fraction of chemical in product (unitless) Conversion factor (1000 mg/g) Time of start of application (min) Application time (min) First-order rate constant for emissions decline (min-1) Time (min) 0/1 value used to indicate if product is actively in use 0 if 𝑡 − (𝑡𝑠𝑡𝑎𝑟𝑡 + 𝑡𝑎 ) < 0 1 if 𝑡 − (𝑡𝑠𝑡𝑎𝑟𝑡 + 𝑡𝑎 ) > 0 𝐸𝐹 = Where: 𝐶𝑐ℎ𝑎𝑚𝑏𝑒𝑟 𝐶𝑐ℎ𝑎𝑚𝑏𝑒𝑟 𝐿𝐹 × 𝐴𝐶𝐻 Emission Factor (µg/m2-hr) Chamber concentration (µg/m3) Loading factor (m2/m3) air changes per hour Based on the chamber air flow rate, foam sample surface area, and indoor air assumptions, the above equation can be reworked to find predicted air concentrations: 𝐶𝑎𝑖𝑟, 𝑝𝑟𝑒𝑑𝑖𝑐𝑡𝑒𝑑 = 𝐸𝐹 × 0.5