National Institute for Occupational Safety and Health (NIOSH). 2022b. Direct-on-filter analysis for respirable crystalline silica using a portable FTIR instrument. By Chubb LG, Cauda EG. Pittsburgh PA: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, DHHS (NIOSH) Publication No. 2022–108, IC 9533.
Other documents for the same rulemaking (all, by stage)
References
Ashley E, Cauda E, Chubb LG, Tuchman DP, Rubinstein EN [2020]. Performance comparison of four portable FTIR instruments for direct-on-filter measurement of respirable crystalline silica. Ann Work Expo Health, https://doi.org/10.1093/annweh/wxaa031.
Bartley DL, Chen C-C, Song R, Fischbach TJ [2010]. Respirable aerosol sampler performance testing. AIHAJ 55(11):1036–1046, https://doi.org/10.1080/15428119491018303.
Cauda E, Chubb L, Reed R, Stepp R [2018]. Evaluating the use of a field-based silica monitoring approach with dust from copper mines. J Occup Environ Hyg 15(10):732–742, https://doi.org/10.1080/15459624.2018.1495333.
Cauda E, Miller A, Drake P [2016]. Promoting early exposure monitoring for respirable crystalline silica: Taking the laboratory to the mine site. J Occup Environ Hyg 13(3):D39–45, https://www.ncbi.nlm.nih.gov/pubmed/26558490.
Foster RD, Walker RF [1984]. Quantitative determination of crystalline silica in respirable-size dust samples by infrared spectrophotometry. Analyst 109:1117–1127, https://doi.org/10.1039/AN9840901117.
Harris G, Maguire B [1968]. A gravimetric dust sampling instrument (SIMPEDS): Preliminary results. Ann Occup Hyg 11:195–201, https://doi.org/10.1093/annhyg/11.3.195.
Hart JF, Autenrieth DA, Cauda E, Chubb L, Spear TM, Wock S, Rosenthal S [2018]. A comparison of respirable crystalline silica concentration measurements using a direct-on-filter Fourier transform infrared (FT-IR) transmission method versus a traditional laboratory X-ray diffraction method. J Occup Environ Hyg 15(10):743–754, https://doi.org/10.1080/15459624.2018.1495334.
Lee T, Lee L, Cauda E, Hummer J, Harper M [2017]. Respirable size-selective sampler for endof-shift quartz measurement: Development and performance. J Occup Environ Hyg 14(5):335– 342, https://doi.org/10.1080/15459624.2016.1252845. Lidén G, Kenny LC [1993]. Optimization of the performance of existing respirable dust samplers. Appl Occup Environ Hyg 8(4):386–391, https://doi.org/10.1080/1047322x.1993.10389224. Maynard AD [1993]. Respirable dust sampler characterisation: Efficiency curve reproducibility. J Aerosol Sci 24:S457–S458, https://doi.org/10.1016/0021-8502(93)90321-Y.
Miller AL, Drake PL, Murphy NC, Cauda E, LeBouf R, Markevicius G [2013]. Deposition uniformity of coal dust on filters and its effect on the accuracy of FTIR analyses for silica. Aerosol Sci Technol, https://doi.org/10.1080/02786826.2013.787157.
Miller AL, Drake PL, Murphy NC, Noll JD, Volkwein JC [2012]. Evaluating portable infrared spectrometers for measuring the silica content of coal dust. J Environ Monit 14(1):48–55, http://dx.doi.org/10.1039/C1EM10678C.
MSHA [2013a]. Method P2 X-ray diffraction determination of quartz and cristobalite in respirable mine dust. https://arlweb.msha.gov/Techsupp/pshtcweb/MSHA%20P2.pdf.
MSHA [2013b]. Method P7 Infrared determination of quartz in respirable coal mine dust. https://arlweb.msha.gov/Techsupp/pshtcweb/MSHA%20P7.pdf.
NIOSH [1998]. Method 0600 Particulates not otherwise regulated, respirable. NIOSH Manual of Analytical Methods, Fourth Edition, https://www.cdc.gov/niosh/docs/2003-154/pdfs/0600.pdf.
NIOSH [2002]. NIOSH hazard review: health effects of occupational exposure to respirable crystalline silica. Publication No. 2002-129. Cincinnati, OH: National Institute for Occupational Safety and Health, https://www.cdc.gov/niosh/docs/2002129/pdfs/2002129.pdf?id=10.26616/NIOSHPUB2002129.
NIOSH [2003a]. Chapter R: Determination of Airborne Crystalline Silica. NIOSH Manual of Analytical Methods, Fourth Edition, https://www.cdc.gov/niosh/docs/2003154/pdfs/chapterr.pdf.
NIOSH [2003b]. Method 7500 Silica, crystalline, by XRD (filter redeposition) NIOSH Manual of Analytical Methods, Fourth Edition, https://www.cdc.gov/niosh/docs/2003-154/pdfs/7500.pdf.
NIOSH [2016a]. Chapter AE: Factors affecting aerosol sampling. NIOSH Manual of Analytical
Methods, Fifth Edition, https://www.cdc.gov/niosh/docs/2014-151/pdfs/chapters/chapter-ae.pdf.
NIOSH [2016b]. Chapter SA: General considerations for sampling airborne contaminants.
NIOSH [2017a]. Method 7602 Silica, crystalline by IR (KBr pellet). NIOSH Manual of Analytical Methods, Fifth Edition, https://www.cdc.gov/niosh/nmam/pdf/7602.pdf.
NIOSH [2017b]. Method 7603 Quartz in coal mine dust, by IR (redeposition). NIOSH Manual of Analytical Methods, Fifth Edition, https://www.cdc.gov/niosh/nmam/pdf/7603.pdf. Ojima J [2003]. Determining of crystalline silica in respirable dust samples by infrared spectrophotometry in the presence of interferences. J Occup Health 45:94–103, https://doi.org/10.1539/joh.45.94.
OSHA [2015]. Method ID-142 Crystalline silica, quartz and cristobalite. https://www.osha.gov/dts/sltc/methods/inorganic/id142/id142.pdf.
Pampena J, Cauda E, Chubb L, Meadows J [2019]. Use of the field-based silica monitoring technique in a coal mine: a case study. Min Metall Explor, https://doi.org/10.1007/s4246101900161-0.
Pickard KJ, Walker RF, West NG [1985]. A comparison of X-ray diffraction and infrared spectrophotometric methods for the analysis of alpha-quartz in airborne dusts. Ann Occup Hyg 29(2):149–167, https://doi.org/10.1093/annhyg/29.2.149.
Stacey P, Lee T, Thorpe A, Roberts P, Frost G, Harper M [2014]. Collection efficiencies of high flow rate personal respirable samplers when measuring Arizona road dust and analysis of quartz by x-ray diffraction. Ann Occup Hyg 58(4):512–523, https://doi.org/10.1093/annhyg/met075.
Stacey P, Mecchia M, Verpaele S, Pretorius C, Key-Schwartz R, Mattenklott M, Eypert-Blaison C, Thorpe A, Roberts P, Frost G [2013]. Differences between samplers for respirable dust and the analysis of quartz—an international study, In: Silica and Associated Respirable Mineral
Taylor DG, Nenadic CM, Crable JV [1970]. Infrared spectra for mineral identification. AIHAJ 31(1):100–108, https://doi.org/10.1080/0002889708506215. Appendix A: Additional Resources for Field-based Monitoring Listed below are tools that can support and facilitate field-based monitoring. Some tools are used in conjunction with the instrument software; several versions are available to accommodate different software packages. Other tools are independent of the instrument software and the same version can be utilized by any user. All of the following resources are freely available online. Software-specific Resources (https://github.com/niosh-mining/fast/) Experiment setup files (see Table 2) Macros for spectral processing Report templates General resources (https://github.com/niosh-mining/fast/)
https://doi.org/10.26616/NIOSHPUB2022108
https://doi.org/10.1080/1047322x.1993.10389224.
J Aerosol Sci 24:S457–S458, https://doi.org/10.1016/0021-8502(93)90321-Y.