U.S. Environmental Protection Agency (EPA). 1996. Ambient levels and noncancer health effects of inhaled crystalline and amorphous silica: health issue assessment
Other documents for the same rulemaking (all, by stage)
References
Environmental Protection Agency. (1994b) National air quality and emissions trends report, 1993. Research Triangle Park, NC: Office of Air Quality Planning and Standards; EPA report no. EPA 454/R-94-026.
Environmental Protection Agency. (1996) Air quality criteria for particulate matter. Research Triangle Park, NC: National Center for Environmental Assessment-RTP Office; report nos. EPA/600/P-95/001aF-cF. 3v. Available from: NTIS, Springfield, VA; PB96-168224.
A. (1982) Immunotoxicology of silica. Crit. Rev. Toxicol. 10: 303-319. University of California at Davis. (1992) Measurement of particulate exposures during rice farming operations [draft research final report]. Sacramento, CA: California Air Resources Board; interagency agreement no. A032-177; October 28.
D. (1989) Does silicosis still occur? JAMA J. Am. Med. Assoc. 262: 3003-3007. 9-15
Vallyathan, V. (1994) Generation of oxygen radicals by minerals and its correlation to cytotoxicity. Environ. Health Perspect. 102(suppl. 10): 111-115.
Vallyathan, V.; Shi, X.; Dalal, N. S.; Irr, W.; Castranova, V. (1988) Generation of free radicals from freshly fractured silica dust: potential role in acute silica-induced lung injury. Am. Rev. Respir. Dis. 138: 1213-1219.
Shoemaker, D. A.; Pretty, J. R.; Khan, A.; Stettler, L. E.; Teass, A. (1993) Acute silicosis: etiology? In: Second international symposium on silica, silicosis, & cancer: program syllabus, Thursday, October 28, 1993; San Francisco, CA. Berkeley, CA: Western Consortium for Public Health; p. 263.
Pretty, J. R.; McLaurin, J. L.; Khan, A.; Teass, A. (1995) Freshly fractured quartz inhalation leads to enhanced lung injury and inflammation. Am. J. Respir. Crit. Care Med. 152: 1003-1009.
S. (1989) Silica exposure and silicosis among Ontario hardrock miners: II. exposure estimates. Am. J. Ind. Med. 16: 13-28.
Verma, D. K.; Sebestyen, A.; Julian, J. A.; Muir, D. C. F.; Shaw, D. S.; MacDougall, R. (1994) Particle size distribution of an aerosol and its sub-fractions. Ann. Occup. Hyg. 38: 45-58.
A. (1991) Regulatory implications of airborne respirable free silica variability in underground coal mines. Am. Ind. Hyg. Assoc. J. 52: 107-112.
Vincent, J. H.; Donaldson, K. (1990) A dosimetric approach for relating the biological response of the lung to the accumulation of inhaled mineral dust. Br. J. Ind. Med. 47: 302-307.
Vincent, J. H.; Jones, A. D.; Johnston, A. M.; McMillan, C.; Bolton, R. E.; Cowie, H. (1987) Accumulation of inhaled mineral dust in the lung and associated lymph nodes: implications for exposure and dose in occupational lung disease. Ann. Occup. Hyg. 31: 375-393.
C. (1989) Characterization of excessive collagen production during development of pulmonary fibrosis induced by chronic silica inhalation in rats. Br. J. Exp. Pathol. 70: 305-315.
Wagner, J. C.; Burns, J.; Munday, D. E.; McGee, JO'D. (1982) Presence of fibronectin in pneumoconiotic lesions. Thorax 37: 54-56.
E. (1968) Experimental evaluation of the threshold limit of cristobalite—calcined diatomaceous earth. Am. Ind. Hyg. Assoc. J. 29: 211-221.
A. (1991a) Four-week inhalation toxicity study with Ludox colloidal silica in rats: pulmonary cellular responses. Fundam. Appl. Toxicol. 16: 590-601.
F. (1991b) Development of a short-term inhalation bioassay to assess pulmonary toxicity of inhaled particles: comparisons of pulmonary responses to carbonyl iron and silica. Toxicol. Appl. Pharmacol. 107: 350-368.
A. (1995) Differential pulmonary responses in rats inhaling crystalline, colloidal or amorphous silica dusts. In: Goldsmith, D. F.; Wagner, G. R.; Saffiotti, U.; Rabovsky, J.; Leigh, J., eds. Second international symposium on silica, silicosis and cancer; October 1993; San Francisco, CA. Scand J. Work Environ. Health 21(suppl. 2): 19-21.
G. (1995) Deriving silica concentrations from silicon air pollution measures [personal communication]. Las
Watson, J. G.; Chow, J. C.; Richards, L. W.; Neff, W. D.; Andersen, S. R.; Dietrich, D. L.; Houck, J. E.; Olnez, I. (1988) The 1987-88 metro Denver brown cloud study: v. I, II, III. Reno, NV: Desert Research Institute; final report no. 8810.1F(1-3).
L. (1993) Epidemic of accelerated silicosis in West Texas sandblasters. In: Second international symposium on silica, silicosis, & cancer: program syllabus, Thursday, October 28, 1993; San
H. (1977) Chronic obstructive lung disease in gold miners. In: Walton, W. H., ed. Inhaled particles
D. (1982) Amorphous silica. In: Kirk-Othmer encyclopedia of chemical technology: v. 20, refractories to silk. 3rd ed. New York, NY: John Wiley & Sons; pp. 766-781.
C. (1981) Respiratory effects of inhaled amorphous silica. In: Dunnom, D. D., ed. Health effects of synthetic silica particulates: a symposium sponsored by ASTM Committee E-34 on Occupational Safety and Health and the Industrial Health Foundation; November 1979; Benalmadena-Costa (Torremolinos), Spain. Philadelphia, PA: American Society for Testing and Materials; pp. 185-198; ASTM special technical publication 732.
W. (1978) The pulmonary effects of inhaled inorganic dust. In: Clayton, G. D.; Clayton, F. E., eds. Patty's industrial hygiene and toxicology: v. I, general principles. 3rd rev. ed. New York, NY: John Wiley & Sons; pp. 165-202.
Wright, J. L.; Harrison, N.; Wiggs, B.; Churg, A. (1988) Quartz but not iron oxide causes air-flow obstruction, emphysema, and small airways lesions in the rat. Am. Rev. Respir. Dis. 138: 129-135.
Wright, J. L.; Cagle, P.; Churg, A.; Colby, T. V.; Myers, J. (1992) Diseases of the small airways. Am. Rev. Respir. Dis. 146: 240-262.
Wu, Z.; Hearl, F.; Peng, K.; McCawley, M.; Chen, A.; Dosemeci, M.; Chen, J.; McLaughlin, J.; Rexing, S.; Blot, W. (1991) Current occupational exposures in Chinese iron and copper mines. Appl. Occup. Environ. Hyg. 7: 735-743.
Xu, X.-Z.; Cai, X.-G.; Men, X.-S.; Yang, P.-Y.; Yang, J.-F.; Jing, S.-L.; He, J.-H.; Si, W.-Y. (1993) A study of siliceous pneumoconiosis in a desert area of Sunan County, Gansu Province, China. Biomed. Environ. Sci. 6: 217-222.
Yang, D.; Yuan, Y.; Chen, J.; Blot, W. J.; Reger, R. B.; Hodous, T. (1991) Pilot results: Sion-American chest x-ray interpretations. In: Study of silicosis and lung cancer for dust exposed workers (silica, silicosis and lung cancer).
Ziskind, M.; Jones, R. N.; Weill, H. (1976) Silicosis. Am. Rev. Respir. Dis. 113: 643-665. 9-17
OCCUPATIONAL SAMPLING METHODS Personal sampling commonly is performed using a variable-rate flow pump and a respirable dust cyclone. Samples are collected onto a cellulose diffuser membrane behind the filter. Sampling pumps are commonly worn on belts, and filters are placed in the breathing zone. Filters are connected to pumps by flexible plastic tubing and checked periodically during the day. For a person working on hazardous machinery, stationary sampling pumps may be placed away from the worker's activities, but at the same level as the worker's breathing zone. The amount of particulate matter is determined by weighing the filter paper after sampling and subtracting the before-use filter weight. Determination of silica percentage in dusts requires use of X-ray diffraction or infrared methods discussed later in this appendix. In general, multiple samples are taken in order to reflect differences in dust during different shifts and production times and using different industrial materials. When completed, mean values for dust mass concentrations in milligrams per cubic meter over 8-h shifts are reported (Lorberau and Abell, 1995). Although these methods have been used to estimate ambient crystalline silica levels, it may not be appropriate for this purpose because of the question of sensitivity in using occupational methods to estimate potential ambient exposures at lower concentration levels (Howard et al., 1991;
McCormick, 1992). AMBIENT SAMPLING METHODS Ambient air sampling is often performed with dichotomous samplers. These samplers permit air samples to be divided into groups according to particle sizes. Common size selections include TSP and PM10; fine and coarse PM10 (<2.5 Fm and 2.5 to 10 Fm, respectively); and respirable and nonrespirable PM10 (<5 Fm and >5 Fm, respectively). Sizes are adjusted by using different port diameters and filter membrane porosities (Reynolds et al., 1991). Area monitoring pump flow rates can be set with rotameters built into the pump case. Polyvinyl chloride (PVC) filters are better than quartz filters for collection of dust to measure crystalline silica levels because they provide greater accuracy for X-ray assay methods (University of California at Davis, 1992). Sampling times and flow rates are variable and must be considered when total concentrations are calculated. After the samplers have collected suspended particulate materials, the filters are weighed to calculate the mass concentrations and analyzed using energy dispersive X-ray analysis (EDXA) to determine the concentration of various chemical elements (Moore, 1992). Many factors, including air flows, particle sizes, and mathematics of sample placement, will affect particle measures. Furthermore, placement of pumps and samplers is critical to the interpretation of results but is rarely described. Studies by Gillette and co-workers (Gillette and
Passi, 1988; Gillette and Hanson, 1989; Johnson et al., 1992) demonstrate that placement can alter greatly the quantities measured. External and physical factors of the monitoring devices themselves can add to measurement discrepancies. Placement and location of monitoring devices, their total number, and differences in technology can result in data discrepancies (U.S.
Environmental Protection Agency, 1991b). Monitor placement and location greatly affect the measured emissions. Factors that are important are distance from the emissions source, elevation of the monitor, and location of the monitor in relation to wind-flow patterns. If monitoring devices are placed upwind from a source, they may underestimate mean emission concentrations; if downwind, they may overestimate mean emission concentrations. Monitor height above ground surface influences estimates of total particles and the relative distribution of particle sizes.
Hanson, 1989). Distance from an emission source will affect similarly the measured emissions because increasing distance gives larger and heavier particles more chance to settle (Johnson et al., 1992; Gillette and Hanson, 1989). It has been observed that there is a nonuniform distribution of the components of particulate emissions with respect to size (Davis et al., 1984;
Gillette, 1992b). For crystalline silica, the particle size distribution is such that particles >10 Fm contain more crystalline silica than do particles <10 Fm (Buckman and Brady, 1969; Davis et al., 1984; Gillette, 1992a).
SILICA ASSAY PROCEDURES Silica can be measured within collected air samples, but there is not universal agreement regarding the best silica assay procedure. Many techniques are valid but are often cost prohibitive when it is necessary to perform repeated assays on a large number of samples. Some ambient sampling techniques of the early 1980s used samplers with quartz filters that were unable to discriminate between crystalline silica from the filter and that from the source being measured. More recent sampling techniques applied in the workplace use PVC or cellulose-based materials without quartz filters and permit testing without interaction. However, an economically valid analytic polycarbonate methodology for ambient silica dust sampling awaits development (McCormick, 1992). At present, there is controversy regarding silica assay methods, and it is likely that the existing methods will need verification as expertise is refined. California's "Hot Spots" silica monitoring requirements may result in improved measurement methods for both PM10 and crystalline silica.
Stephen E. Brooks ICF Kaiser, International K.S. Crump Division Research Triangle Park, NC, and Ruston, LA Prepared for: Jeff Gift, Health Scientist National Center for Environmental Assessment U.S. Environmental Protection Agency Research Triangle Park, NC June 26, 1995
INTRODUCTION This report documents the methods for and results of applying BMD approaches to an epidemiological study of silicosis observed among South African gold miners who were exposed to silica (Hnizdo and Sluis-Cremer, 1993). The goal was to estimate the doses corresponding to possible benchmark levels of response and the lower bounds on those doses, which define the
BMDs, using a model proposed by Hnizdo and Sluis-Cremer (1993). Their model relates cumulative dust or silica exposure to the risk of developing silicosis.