Global Non-CO2 Greenhouse Gas Emission Projections & Marginal Abatement Cost Analysis: Methodology Documentation
Other documents for the same rulemaking (all, by stage)
References: 399 extracted, 0 linked to papers
ICIS Europe. 2015. US INVISTA to close adipic acid plant in Texas. ICIS. Available online at https://www.icis.com/resources/news/2015/10/06/9930535/us-invista-to-close-adipic-acid-plant-in-texas/ Intergovernmental Panel on Climate Change. 2006. 2006 IPCC Guidelines for National Greenhouse Gas Inventories: Volume 3 Industrial Processes and Product Use. Available online at http://www.ipccnggip.iges.or.jp/public/2006gl/pdf/3_Volume3/V3_3_Ch3_Chemical_Industry.pdf
International Fertilizer Industry Association, 2016. IFADATA Statistical Database. International Fertilizer Industry Association. Available online at http://www.fertilizer.org/ifa/ifadata/search
Kollmuss, A., and M. Lazarus. 2010. Industrial N2O Projects Under the CDM: The Case of Nitric Acid Production. Working Paper No. WP-US-1007. Somerville, MA: Stockholm Environment Institute. Available online at http://www.sei-international.org/mediamanager/documents/ Publications/Climate/sei-nitricacid9nov2010.pdf
Mainhardt, H. and D. Kruger. 2000. N2O emissions from adipic acid and nitric acid production. Good Practice and Uncertainty Management in National Greenhouse Gas Inventories. Montreal: Intergovernmental Panel on Climate Change, National Greenhouse Gas Inventories Programme. Available online at http://www.ipccnggip.iges.or.jp/public/gp/bgp/3_2_Adipic_Acid_Nitric_Acid_ Production.pdf Organisation of Economic Cooperation and Development. 2004. SIDS Initial Assessment Report for SIAM 18 Adipic Acid. Paris, France: OECD. Pérez-Ramírez, J., F. Kapteijn, K. Schöffel, and J. A. Moulijn. 2003. Formation and control of N2O in nitric acid production: Where do we stand today? Applied Catalysis B: Environmental, 44(2), 117–151. doi:10.1016/S0926-3373(03)00026-2.
Schneider, L., M. Lazarus, and A. Kollmuss. 2010. Industrial N2O projects under the CDM: Adipic acid—A case of carbon leakage? Working Paper No. WP-US-1006. Somerville, MA: Stockholm Environment Institute. Available online at http://ec.europa.eu/clima/consultations/0004/ unregistered/cdm_watch_2_en.pdf
Shen, L., J. Haufe, and M.K. Patel. 2009. Product overview and market projection of emerging bio-based plastics
PRO-BIP 2009. Report for European polysaccharide network of excellence (EPNOE) and European bioplastics 243. Available online at https://www.researchgate.net/profile/Li_Shen15/publication/216092211_Product_overviw_and_market_proj ection_of_emerging_bio-based_plastics_PRO-BIP_2009/links/0c9605279efb4e96a8000000.pdf
SRI. January 2010. World Petrochemical Report: Adipic Acid. SRI Consulting. Access Intelligence LLC Inc. Abstract available online at http://www.sriconsulting.com/CEH/Public/Reports/608.5000/
Tenkorang, F. and J. Lowenberg-DeBoer. 2008. Forecasting Long-term Global Fertilizer Demand. Rome: Food and Agriculture Organization of the United Nations. U.S. Environmental Protection Agency. 1991. Alternative Control Techniques Document—Nitric and Adipic Acid Manufacturing Plants. EPA-450/3-91-026. Research Triangle Park, NC: EPA. Available online at http://www.epa.gov/ttn/catc/dir1/nitric.pdf 5-40 Global Non-CO2 Greenhouse Gas Emissions Projections & Marginal Abatement Cost Analysis
SECTION 5 — SECTOR-LEVEL METHODS U.S. Environmental Protection Agency. 2012. Inventory of U.S. Greenhouse Gas Emissions and Sinks: 1990–2010.
Washington, DC: EPA. Available online at http://epa.gov/climatechange/emissions/usinventoryreport.html U.S. Environmental Protection Agency. 2013. Global Mitigation of Non-CO2 Greenhouse Gases: 2010–2030. EPA430-R-13-011. Washington DC: EPA. Available online at https://www.epa.gov/global-mitigation-non-co2greenhouse-gases/global-mitigation-non-co2-ghgs-report-download-report
Zhao, D. November 7, 2011. China adipic acid tumbles 36% on weak demand from PU sector. Market news article from ICIS.com. Available online at http://www.icis.com/Articles/2011/11/07/ 9505810/china-adipic-acidtumbles-36-on-weak-demand-from-pu-sector.html Global Non-CO2 Greenhouse Gas Emissions Projections & Marginal Abatement Cost Analysis 5-41
METHODOLOGY DOCUMENTATION 5.2.2 F-GHG Emissions from Semiconductor Manufacturing Semiconductor manufacturing consists of HFC, PFC, SF6, and NF3 emissions from two repeated activities: (1) cleaning tool chambers used to deposit thin films on substrate surfaces, a process referred to as chemical vapor deposition (CVD) chamber cleaning, and (2) etching intricate patterns into successive layers of films and metals, a process referred to as plasma etching. Film deposition and etching processes begin with the semiconductive crystalline silicon (Si) wafer (or another substrate) and are completed once successive films (layers) are deposited and etched to form a device. EPA GHGRP data indicate that approximately 27% to 46% of emissions result from chamber cleaning processes and 54% to 73% from etching processes (EPA, 2014, 2015, 2016). 5.2.2.1 Semiconductor Manufacturing Projections Methodology
UNFCCC-reported, country-specific estimates were used for historical emission estimates in this source category, when available. For those countries with country-reported emission estimates, emission projections were estimated from the most recent country-reported data through 2050 using growth rates calculated by the Tier 1 methodology. For countries that do not have country-reported historical data, Tier 1-calculated emission estimates were used for the full time series from 1990 through 2050 (see Section 3.3 Generating the Composite Emission Projections, for additional information). Activity data for semiconductor manufacturing included annual semiconductor manufacturing capacity by country from World Fab Watch (SEMI 1996, 2001, 2002, 2003, 2006 and 2007) and World Fab Forecast (SEMI 2008, 2009, 2010, 2011, 2012, and 2016), and growth of manufacturing capacities based on the growth in each country’s gross domestic product. Emission factors were based on EPA’s
GHGRP data and activity from the aforementioned sources (2016). Emission reductions were incorporated based on the EPA and U.S. semiconductor industry’s voluntary partnership and the global industry commitment through the World Semiconductor Council to reduce F-GHG emissions. The Tier 1 equation to estimate HFC, PFC, SF6, and NF3 emissions from semiconductor manufacturing is as follows: 𝐸𝑖 = 𝐸𝐹𝑖 ∗ 𝐶𝑈 ∗ 𝐶𝑑 ∗ [1 − (𝑎𝑖 ∗ 𝑑𝑖 )] (5.7) where: Emissions of gas i EFi =
METHODOLOGY DOCUMENTATION When comparing country emissions as calculated using the approach described above (Tier 1) with emissions reported to the UNFCCC, cases of over- or underestimations were identified. To address these instances, when feasible, country emission projections were estimated using the most recent country-reported data (2015) and the growth rates and country shares described above.
Finally, shares of emissions by gas were calculated from the historical reported emissions to give percentages of HFC, PFC, SF6, and NF3 emissions of total semiconductor emissions. These shares were applied to country emissions for all years, holding 2015 shares constant for all future years, to determine country emissions by type of gas. The assumption to hold 2015 shares constant in the projections was made because it cannot be known at this time what new processes and technologies will be used in semiconductor manufacturing, which is a high-tech and rapidly evolving industry. As a result, if new technologies come online in future years, the shares of emissions could change. Emission Reductions in Baseline Scenario In the 1990s, the absence of emission control measures, rapid growth of the semiconductor industry (11 to 12% per year through the late 1990s), and increasing complexity of microchips could have potentially resulted in significantly increased future emissions from semiconductor manufacturing. In response, the EPA and the U.S. semiconductor industry launched a voluntary partnership to reduce F-GHG emissions in 1996. In 1999, the U.S. partnership catalyzed a global industry commitment through the World Semiconductor Council (WSC). Most WSC member countries—the United States, EU, Japan, South Korea, and Taiwan25—voluntarily committed to reduce
HFC, PFC, SF6, and NF3 emissions to 90% of 1995 levels by 2010.26 At the end of the 2010 WSC goal, the member countries reduced absolute emissions by 32% below the baseline to a level of 2.7 MMTCE, surpassing the 10% reduction target (WSC, 2016). WSC set a subsequent goal for 2020 to implement best practices for new semiconductor fabs to result in a normalized emission rate (NER) of 0.22 kgCO 2e/cm2, which is equivalent to a 30%
SECTION 5 — SECTOR-LEVEL METHODS production yield, and they are only adjusted to increase this yield; a company would not risk negatively affecting it (Beu, 2005; Fthenakis, 2001). Process gas optimizations for CVD clean processes can be implemented because adjustments to these processes are much less precise than etch processes. There is room to reduce emissions without affecting yield. Optimization of clean processes to reduce emissions usually results in small production gains but sometimes can result in large increases in efficiency. Facilities optimizing processes incur labor costs of an estimated $121,370; it was assumed that old fabs incur this cost, while new fabs do not implement this technology because of their assumed use of NF3 remote clean for most of clean processes. 5.2.2.3 Model Facilities The analysis considers two types of facilities, distinguished generally by the size of wafer manufactured: New Facilities: Facilities that manufacture wafers that are 300 mm or larger. These types of facilities tend to have more complex processes, particularly for plasma etching, which can lead to higher emissions. These facilities have a high likelihood of using remote chamber clean processes and are more likely to have abatement installed. Using data from Subpart I of EPA’s GHGRP and information from the World Fab
METHODOLOGY DOCUMENTATION Beu, L. December 2005. Reduction of Perfluorocarbon (PFC) Emissions: 2005 State-of-the-Technology Report.
Burton, S. 2003. Personal communication with Brown of Motorola (2002) supplemented by personal communication with Von Gompel of BOC Edwards (2003), research of DuPont’s Zyron Web site (2003), and personal communication with Air Liquide regarding thermal destruction, NF 3 remote clean, and capture membrane unit costs.
Fthenakis, V. December 2001. Options for Abating Greenhouse Gases from Exhaust Streams. Brookhaven National Laboratory. Available online at http://www.bnl.gov/isd/documents/23784.pdf Intergovernmental Panel on Climate Change. 2006. 2006 IPCC Guidelines for National Greenhouse Gas Inventories. The National Greenhouse Gas Inventories Programme (Volume 3, Chapter 6: Electronics Industry Emissions), The Intergovernmental Panel on Climate Change, H.S. Eggleston, L. Buendia, K. Miwa, T. Ngara, and K. Tanabe (eds.). Hayama, Kanagawa, Japan. Motorola. October 18, 1998. Long-Term Evaluation of Litmus “Blue” Inductively-Coupled Plasma Device for Pointof-Use PFC and HFC Abatement. Presented at Semicon Southwest 99: A Partnership for PFC Emissions
SECTION 5 — SECTOR-LEVEL METHODS Other Sources Reviewed for this Analysis: Semiconductor Equipment and Materials Industry. 2011 World Fab Forecast, May 2011 Edition. Semiconductor Equipment and Materials Industry. 2012 World Fab Forecast, August 2012 Edition. Semiconductor Equipment and Materials Industry. 2018 World Fab Forecast, May 2018 Edition. Clean Development Mechanism Proposed Methodologies Reviewed: NM0289: PFC gas emission reduction by gas replacement for CVD cleaning at 200 mm (8 inches) process by Hynix Semiconductor Inc. (submitted September 2008) NM0303: PFC gas emissions reduction by gas replacement for CVD cleaning processes in semiconductor processing operations (submitted April 2009) NM0317: Substitution of fluorinated compound (FC) gases for cleaning CVD reactors in the semiconductor industry (submitted June 2009) NM0330: Substitution of fluorinated compound (FC) gases for cleaning CVD reactors in the semiconductor industry (submitted December 2009) NM0332: PFCs emission reduction from installation of an abatement device in a semiconductor manufacturing facility (submitted January 2010) NM0335: PFC emission reduction by gas replacement in the process of CVD cleaning in semiconductor production (submitted February 2010) Global Non-CO2 Greenhouse Gas Emissions Projections & Marginal Abatement Cost Analysis 5-51
UNFCCC-reported, country-specific estimates were not available for any historical years for this emission source. Therefore, the 2006 IPCC Tier 1 methodology (IPCC, 2006) was used to estimate emissions. Activity data for Photovoltaic Manufacturing include maximum design capacities from DisplaySearch database (2009) as well as global installed photovoltaic capacities from EIA (2017). Manufacturing processes of PV cells with c-Si PV cells and a-Si and tandem a-Si/nanocrystalline silicon PV cells use F-GHGs, while other thin film technologies do not.
SECTION 5 — SECTOR-LEVEL METHODS a-Si/nanocrystalline (nc) silicon PV cells use F-GHGs, while other thin film technologies do not. Therefore, this analysis was limited to the c-Si and a-Si PV cell markets. Activity Data Historical The activity data for emission estimates from PV manufacturing were area (m2) of PV panels produced, which was derived from maximum design capacities expressed in total peak power production, in megawatts (MW), for each country and the world. Historical maximum design capacities,31 in units of MW, were determined by the following various methods: 1990 and 1995: Maximum design capacities in these years were assumed to be 0 MW because the sector was so small in this time period that any associated manufacturing emissions were assumed to be negligible. 2000, 2005, and 2010: Maximum design capacities by country and for the world in 2000, 2005, and 2010 were extracted directly from the DisplaySearch database (DisplaySearch, 2009). 2015: Maximum design capacities by country and the world in 2015 were estimated from the International Energy Outlook (EIA, 2017). It was assumed that the number of total PV panels installed in 2015, calculated based on the difference between the total PV capacity in 2015 and 2014, was the total
Beu, L. December 2005. Reduction of Perfluorocarbon (PFC) Emissions: 2005 State-of-the-Technology Report.
TT#0510469A-ENG. Albany, NY: International SEMATECH Manufacturing Initiative. Available online at http://www.epa.gov/highgwp/semiconductor-pfc/documents/final_tt_report.pdf Brown et al., 2012. Catalytic technology for PFC emissions control. Solid State Technology. Available online at http://www.electroiq.com/content/eiq-2/en/articles/sst/print/volume-44/issue-7/features/emissionscontrol/catalytic-technology-for-pfc-emissions-control.html
Burton, S. 2003. Personal communication with Brown, Motorola (2002) supplemented by personal communication with Von Gompel, BOC Edwards (2003), research on DuPont’s Zyron Web site (2003), and personal communication with Air Liquide regarding thermal destruction, NF3 remote clean, and capture membrane unit costs. 5-58 Global Non-CO2 Greenhouse Gas Emissions Projections & Marginal Abatement Cost Analysis
SECTION 5 — SECTOR-LEVEL METHODS DisplaySearch. 2009. DisplaySearch Q4'09 Quarterly PV Cell Capacity Database & Trends Report. DisplaySearch,
LLC. Fthenakis, V. December 2001. Options for Abating Greenhouse Gases from Exhaust Streams. Upton, NY. Brookhaven National Laboratory. Available online at http://www.bnl.gov/isd/documents/23784.pdf
Fthenakis, V., D. Clark, M. Moalem, P. Chandler, R. Ridgeway, F. Hulbert, D. Cooper, P. Maroulis. 2010. “Life-Cycle Nitrogen Trifluoride Emissions from Photovoltaics”. Environ. Sci. Technology. 2010 44 22 8750-8757. doi:10.1021/es100401y.
Hattori, K., K. Sakurai, N. Watanabe, H. Mangyou, S. Hasaka, and K. Shibuya. September 25–27, 2006. Application of atmospheric plasma abatement system for exhausted gas from MEMS etching process. Presented at the Institute of Electrical and Electronics Engineers International Symposium on Semiconductor Manufacturing,
Tokyo, Japan. Intergovernmental Panel on Climate Change. 2006. 2006 IPCC Guidelines for National Greenhouse Gas Inventories. The National Greenhouse Gas Inventories Programme (Volume 3, Chapter 6: Electronics Industry Emissions), H.S. Eggleston, L. Buendia, K. Miwa, T. Ngara, and K. Tanabe (eds.). Hayama, Kanagawa, Japan. Global Non-CO2 Greenhouse Gas Emissions Projections & Marginal Abatement Cost Analysis 5-59
METHODOLOGY DOCUMENTATION 5.2.4 PFC Emissions from Flat Panel Display Manufacturing Flat panel display (FPD), namely liquid crystal display (LCD) panels, are components of screens used in consumer electronics, computers, and mobile devices. FPD manufacturing is a relatively new industry that continues to grow as demand for these screens increases. The FPD manufacturing process uses SF 6, PFCs, including CF4, and NF3 in the etching and chamber cleaning processes. These F-GHGs are used for CVD cleaning processes and plasma dry etching during manufacture of arrays of thin-film transistors on glass substrates, which switch pixels of LCDs and organic light-emitting diode displays. Various F-GHGs play different roles in each of these processes (e.g., CF4 is mainly used for etching, while SF6 and NF3 are used for both etching and cleaning) and are selected by manufacturers based on their chemical and physical properties and ability to efficiently perform in the process (EPA, 2017). In general, almost all manufacturers used SF6, NF3, and CF4, with a smaller mix of other HFCs and PFCs in some instances. 5.2.4.1 Flat Panel Display Manufacturing Projections Methodology
EPA assumed that CU is equivalent to 88% for 1990 through 2010. 5-60 Global Non-CO2 Greenhouse Gas Emissions Projections & Marginal Abatement Cost Analysis
Burton, 2003), which covers the purchase and installation of plasma systems. Plasma abatement systems require an annual operation cost of $1,304 per chamber, which includes general maintenance and use of the systems. The total annual facility cost is $114,114 based on an assumed number of tools per facility and chambers per tool. The use of plasma abatement systems will not result in annual cost savings. NF3 Remote Chamber Clean NF3 remote chamber clean is an alternative cleaning technology that has the benefit of having a particularly high utilization rate of NF3 (~98%; IPCC, 2006), resulting in relatively low emissions compared with traditional chamber cleans. (Note: The stated utilization is based on uses in semiconductor manufacturing; as a result of large gas flows in FPD manufacturing, the actual utilization may be lower.) NF3 remote clean systems dissociate NF3 using Global Non-CO2 Greenhouse Gas Emissions Projections & Marginal Abatement Cost Analysis 5-63
CDM project #3333 Thermal abatement Etch and clean Fthenakis (2001), Beu (2005), and EPA (2009) Catalytic abatement Etch and clean Fthenakis (2001), Brown et al. (2012) Plasma abatement Etch Fthenakis (2001), Hattori et al. (2006) NF3 remote chamber clean Clean Beu (2005) Gas replacement Clean
Brown S., et al. 2012. Catalytic technology for PFC emissions control. Solid State Technology. Available online at http://www.electroiq.com/content/eiq-2/en/articles/sst/print/volume-44/issue-7/features/emissionscontrol/catalytic-technology-for-pfc-emissions-control.html
Burton, S., 2003. Personal communication with Brown, Motorola (2002) supplemented by personal communication with Von Gompel, BOC Edwards (2003), research of DuPont’s Zyron Web site (2003), and personal communication with Air Liquide regarding thermal destruction, NF3 Remote Clean, and Capture Membrane unit costs. DisplaySearch. 2009. DisplaySearch Q4'09 Quarterly FPD Supply/Demand and Capital Spending Report Database.
DisplaySearch, LLC. DisplaySearch. 2016. DisplaySearch Q4'16 Large Area Display Production Strategy Tracker. DisplaySearch, LLC.
Fthenakis, V. December 2001. Options for Abating Greenhouse Gases from Exhaust Streams. Upton, NY: Brookhaven National Laboratory. Available online at http://www.bnl.gov/isd/documents/23784.pdf
Hattori, K., K. Sakurai, N. Watanabe, H. Mangyou, S. Hasaka, and K. Shibuya. September 25–27, 2006. Application of atmospheric plasma abatement system for exhausted gas from MEMS etching process. Presented at the Institute of Electrical and Electronics Engineers International Symposium on Semiconductor Manufacturing 2006, Tokyo, Japan. Intergovernmental Panel on Climate Change. 2006. 2006 IPCC Guidelines for National Greenhouse Gas Inventories. The National Greenhouse Gas Inventories Programme (Volume 3, Chapter 6: Electronics Industry Emissions), The Intergovernmental Panel on Climate Change, H.S. Eggleston, L. Buendia, K. Miwa, T. Ngara, and K. Tanabe (eds.). Hayama, Kanagawa, Japan. Motorola. October 18, 1998. Long-term evaluation of litmus “blue” inductively-coupled plasma device for point-ofuse PFC and HFC abatement. Presented at Semicon Southwest 99: A Partnership for PFC Emissions Reductions,
Austin, TX. Taiwan TFT LCD Association. 2012. PFCs Reduction Experiences in TTLA. U.S. Environmental Protection Agency. 2017. Center for Corporate Climate Leadership Sector Spotlight: Electronics. Available online at https://www.epa.gov/climateleadership/center-corporate-climate-leadership-sectorspotlight-electronics. 5-66 Global Non-CO2 Greenhouse Gas Emissions Projections & Marginal Abatement Cost Analysis
SECTION 5 — SECTOR-LEVEL METHODS 5.2.5 SF6 Emissions from Electric Power Systems SF6 is used as both an arc-quenching and insulating medium in electrical transmission and distribution equipment. SF6 emissions from electrical equipment used in transmission and distribution systems occur through leakage and handling losses. Leakage losses can occur at gasket seals, flanges, and threaded fittings and are generally larger in older equipment. Handling emissions occur when equipment is opened for servicing, SF 6 gas analysis, or disposal. The manufacture of equipment for electrical transmission and distribution can also result in SF6 emissions, but this source is not included in this report.41 Several factors affect SF6 emissions from electrical equipment, including the type and age of SF 6-containing equipment, and the handling and maintenance protocols used by electric utilities. Historically, approximately 20% of total global SF6 sales have been attributed to electric power systems, where the SF6 is believed to have been used primarily to replace emitted SF6. Approximately 60% of global sales have gone to manufacturers of electrical equipment, where the SF6 is believed to have been mostly banked in new equipment (Smythe, 2004). 5.2.5.1 Electric Power Systems Projections Methodology
UNFCCC-reported, country-specific estimates were used for historical emission estimates in this category, when available. The 2006 IPCC Tier 1 methodology (IPCC, 2006) was not well suited to estimate emissions from electric power systems given the type of data available on global SF6 use. Instead, if country-reported emission estimates were not available for any historical years, estimates were calculated based on a methodology derived from an equation in the IPCC Good Practice Guidance (IPCC, 2000). Activity data included a RAND survey of global SF6 sales to electric utilities and equipment manufacturers from Knopman and Smythe (2007), estimates of net electricity generation and consumption from EIA’s International Energy Outlook (2017), and a report of emissions from equipment use and decommissioning in the European Union from Ecofys (2005). The successful attainment of developed country SF6 reduction goals are accounted in the emission projections. Methods contained in the 2006
IPCC Guidelines for National Greenhouse Gas Inventories (IPCC, 2006) were not well suited to estimate emissions from electric power systems given the type of data available on global SF6 use. Instead, estimates were calculated using the following equation, which was derived from the equation for emissions in the IPCC Good Practice Guidance (IPCC, 2000): Emissions = SF6 purchased to refill existing equipment + nameplate capacity of retiring equipment (5.13) This equation holds true regardless of whether the gas is released or recovered from retiring equipment. Recovered gas is used to refill existing equipment, lowering the amount of SF 6 purchased by utilities for this purpose. The primary driving factors for determining historical emissions in the electric power systems methodology are the source data from UNFCCC, RAND, and EIA. For determining projected emissions, the primary factor in determining these estimates is the methodology for the projection calculation, described in-depth below. Activity Data Historical
RAND, EIA, and Ecofys data were used to estimate historical emissions in the absence of country-level estimates from UNFCCC. First, total world SF6 emissions were estimated using data from the 2007 RAND survey (Knopman and Smythe, 2007). The data included total gas purchases by utilities and equipment manufacturers Although these emissions were not explicitly estimated in this study, some A1 countries report emissions from the manufacture of equipment for electrical transmission and distribution equipment manufacture within this source category. In these cases, this source category includes these emissions. Global Non-CO2 Greenhouse Gas Emissions Projections & Marginal Abatement Cost Analysis 5-67
METHODOLOGY DOCUMENTATION from 1961 through 2006 (believed to include all SF6-consuming countries except Russia and China). From these data, the two components of the above emission equation were calculated using the following assumptions: SF6 emitted by utilities in a given year is approximately equal to SF6 purchased to refill existing equipment in a given year.42,43 The nameplate capacity of retiring equipment in a given year was assumed to be equal to 77.5% of the amount of gas purchased by electrical equipment manufacturers 30 years previous (e.g., in 1990, the nameplate capacity of retiring equipment is equal to 77.5% of the gas purchased by original equipment manufacturers in 1960).44 The remaining 22.5%45 was assumed to have been emitted at the time of manufacture. The RAND survey data were adjusted to include sales for China and Russia, which were not included in the survey. To make this adjustment, it was assumed Russian and Chinese SF6 sales were proportional to the net electricity consumption of these countries available from EIA (2017). The total sales for the countries represented in the RAND survey were multiplied by the proportion of China’s and Russia’s net electricity consumption relative to the world net electricity consumption. A 3-year smoothing was applied to the sum of the results to reduce the potential impact of inventory fluctuations on the estimates.
Next, emission estimates were developed for all countries from 1990 through 2006 using the RAND world SF6 emission totals. Known emission values for the United States, the EU,46 and Japan47 were subtracted from the world emission total. The remaining emissions were allocated to countries according to each country’s share of net electricity consumption to the world net electricity consumption minus consumption from the United States, the
EU emissions were based on those provided for equipment use and decommissioning in Reductions of SF6 Emissions from High and Medium Voltage Electrical Equipment: Final Report to CAPIEL (Ecofys, 2005). The Ecofys study relied on bottom-up estimates of emission rates and of the SF6 bank in equipment, both of which varied by region and over time. A newer report was published by Ecofys (2010); however, specific country-level estimates were not presented in a table format. Historical emissions data for Japan used in this analysis were available through the UNFCCC flexible query system (UNFCCC, 2016). 5-68 Global Non-CO2 Greenhouse Gas Emissions Projections & Marginal Abatement Cost Analysis