R-513A Attachment 3
Other documents for the same rulemaking (all, by stage)
References: 9 extracted, 0 linked to papers
GWP; Phys. Chem. Chem. Phys., 2007, 9, R-1234yr Opteon 6 YF 1-13 ibid Reference: AR4 1PCC Report Reference: CF3CMCH2 and (Z)-CF3CFQC1IF ; temperature dependent OH rate coefficients and GWP; Phys. Chem. Chem. Pkrs., 2007, 9, 1-13 Reference: AR5 1PCC Table 8a Part b) Confidential Mark (X) this box if this page contains CBI Part II - ALTERNATIVE-SPECIFIC INFORMATION (continued) Section C - OTHER STATUTES AND STANDARDS Form 1265-07 (Revised 09/2011)
OMB Control No: 2060-0226 Previous editions are obsolete . Describe whether and how the manufacture, use, and disposal of the ahernative is regubted under other environmental regulatory statutes such as those listed below. List any concentration-based or other numerical standards to which the aRemative is subject under the standards and regulations. Titles of the Clean Air'Act (CAA) other than Title VI YOli applicable to this product the Clean Water Act (CWA) Not applicable iothisproduct the Safe Drinking Water Act (SDWA) Not applicable to this product ihe Resource Conservation and Recovery Act (RCRA) Not applicable to this product the Federal Insecticide, Fungicide, and Rodenticidc Act (FIERA) Not applicable to this product the .1loxic Substances Control Act (TSCA) All components of the refrigerant blend are on the TSCA list the Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) None of the components listed are regulated under CERCLA the Emergency Planning and Community Right to Know Act (EPCRA or SARA Title III) Not applicable to this product State and local taws This product is not flammable, therefore. it is not expected to have any special regulations beyond those already governing safe use of refrigerants f local building code& etc.) Other applicable environmental federal, state, and local laws not mentioned above Mark (X) this box if this page contains CBI Form 1265-07 (Revised 09/2011)
OMB Control No.: 2060-0226 Previous editions are obsolete 2. Describe whether and how occupational, consumer, or general population exposure to the alternative is regulated under health and safety related statutory authorities. such as those implemented by the Food and Drug Administration (FDA), the Occupational Safety and Health Administration (OSHA). the Department of Transportation (DOT). and state and local laws. List any concentration-based or other numerical standards to which the altemative is subject under the above statutes and rezulations. Also list any other standard-setting organizations such as the National Fire Prevention Association (NFPA) the American Society of l [eating, Refrigerating, and Air Conditioning Engineers (AS IRAE). or Underwriters Laboratories (UL) that will evaluate the substitute from a health and safety perspective. Part a) Confidential Part b) The refrigerant components and refrigerant blend will be transponed and handled per the appropriate DOT regulations for flammable and non-flammable liquefied gas. l'art c) The refrigerant blend. Opteon® X1310, has been submitted to ASHRAE for safety classification per standard 34. Optcon® XPIO was granted refrigerant classification Al (non-flammable and low toxicity) and refrigerant nomenclature of R-513A per ASHRAE standard 34. Mark (X) this box if this page contains CBI Form 1265-O7 (Revised 09/2011)
OMB Control No.: 2060-0226 Previous editions are obsolete Part II - ALTERNATIVE-SPECIFIC INFORMATION (continued) Section D - COST AND AVAILABILITV OF THE ALTERNATIVE l. Estimate the cost per pound for the substitute chemical. For alternative processes and technologies, describe installation costs associated with the alternative, Please describe thc information used as the basis for this cost estimate. Cost: Confidential. New Equipment: DuPonfrm Opteoe XPIO can be used with existing equipment designed for R-I 3,1a. with minimal to no equipment costs associated to DuPonITM Opteon2 XPIO. However, in older systems. it may be beneficial to replace elastomeric seals to minimize thc risk of leaks and potentially adjust thc thermal expansion valves (TXVs). Existing Equipment: Conversion costs are determined by servicing costs involving recovery of existing refrigerant. recharge with DuPont-1-m Opteonr XPIO and subsequent system optimization. 2 l'rovide information on production of the substitute. include estimates on: (a) Year substitute will be available if not currently produced. (b) Total pounds production per year (current figure). (c) Years to maxirnum market penetration. (d) Maximum total production per year at market saturation (e) Estimated percentage of market at market saturation. Part a) Confidential Part b) Confidential l'art c) Confidential l'art d) Confidential l'art c) Confidential Mark (X) this box if this page contains CBI Form 1265-07 (Revised 09/2011)
OMB Control No.: 2060-0226 Previous editions are obsolete For each manufacturing site (for manufacturing of substitutes and/or products containing substitutes): (a) Identify all site locations (i.e., name and address) for each chemical manufacturing process. (b) Identify all site locations for manufacturing of products using substitutes (c.g.. refrigerators containing tbe substitutes). (c) Identify the points of release and/or exposure during the manufacture of: (i) the substitute and/or (ii) products containing the substitutcs. (d) Provide information on the magnitude of release if available. along with the media to which the substitute is released (e.g., indoor air, outdoor air, urater, land). Part a) Confidential Part b) Confidential Part c) Confidential Part d) Confidential Mark (X) this box if this page contains CBI Part III - RELEASE AND EXPOSURE DATA Section C- OCCUPATIONAL EXPOSURE AT MANUFACTURE Form 1265-07 (Revised 09/2011)
OMB Control No.: 2060-0226 Previous editions are obsolete For each manufacturing site (manufacturing of substitutes and/or products containing substitutes); (a) Describe thc activities in which workers may be exposed to chemicals at the manufacturing facility. Answer items (b) through (g) for each activity. (b) Describe any protective equipment and engineering controls used to protect workers (e.g., goggles, gloves, chemical hoods). (c) indicate the physical form of chemicals at the time of handling/exposure (e.g., solid, liquid, gas), (d) Estimate average and maximum numbers of workers involved in each activity. (e) Estimate average and maximum duration of activity for any worker, in terms of( ) hours/day and (2) days/year. (f) Enter the contact pathway (e.g., ingestion, inhalation, dermal). (g) Estimate the average and high-end exposure concentrations (separated by a /), being sure to provide units of measure. Part a) Confidential Part b) Confidential Part c) Confidential Part d) Conlidential Part e) Confidential Part 0 Confidential Part g) Confidential Section D - ENVIRONMENTAL RELEASE AND DISPOSAL IN END-USE Form 1265-07 (Revised 09/2011)
OMB Control No.: 2060-0226 Previous editions are obsolete For all end-use scenarios of the substitute (end-uses utilizing the substitute in products and/or processes): (a) Describe the activities in which workers may be exposed to chemicals at the end-use (i.e., during installation. maintenance. inspection, servicing,,or use). Answer items (b) through (g) for each activity. (b) Describe any protective equipment or engineering controls used to protect workers (e.g., goggles, gloves, chemical hoods). (c) Indicate the physical form of chemicals at the time of handling/exposure (e.g., solid, liquid. gas). (d) Estimate average and maximum numbers of workers involved in each activity. (e) Estimate average and maximum duration of activity for any worker. in terms of (1 ) hours/day and (2) days/year. (I) Enter the contact pathway (e.g,. ingestion, inhalation, dermal). (g) Estimate the average and high-end exposure concentrations (separated by a /). being sure to provide units. Personal monitoring data may bc required for some end uses (see pgs. 17-18 of Instructions). Part a) Confidential Part b) Confidential Part c) Confidential Part d) Confidential Part c) Confidential Part I) Confidential Part g) Confidential Reference: Gjoistad et al., J Enriron Menu!. 2003 Apr:5(2):236-40 Section - CONSUMER EXPOSURE Form 1265-07 (Revised 09/2011)
OMB Control No.: 2060-0226 Previous editions are obsolete For each end-use of a substitute (end-uses where a consumer might bc exposed): (a) Identify the potentially exposed consumer population (e.g.. indoor residents). (b) Identify the exposure medium (e.g.. air). (c) Entcr the contact pathway (c.g,. ingestion. inhalation. dermal). (d) Describe the exposure point of concentration. Provide ( I ) average and (2) high-end concentration estimates, including units of measure Part a) DuPont"i Optenne XP1 0 blend is used in air conditioning and refrigeration equipment from which any emission would only occur as a result of equipment failure since the systems are sealed units. It is expected that exposure levels to which the general consumers would be exposed, under these conditions would be minimal and additionally would be expected to occur only once in a consumers lifetime. Additionally, any leakage would normally be expected in the parts of the system which tend to be remote and/or away from the public. Part b) System failures could potentially release the product. As the product is a liquefied gas, even if the product is leaked in the liquid form. it will quickly vaporize and partition into the air. Therefore. potential exposures to the general public are via thc air. Part c) Normally. the potential exposure pathway woukl be inhalation. Part d) Confidential Mark (X) this box if this page contains CB! Form 1265-07 (Revised 09/2011)
OMB Control No.: 2060-0226 Previous editions are obsolete Part III - RELEASE AND EXPOSURE DATA (continued) Section G - GENERAL POPULATION EXPOSURE (optional) For manufacturing of substitutes and products containing substitutes: (a) Identify and number potential general population exposure points. (b) For each exposure point described in (a), identify the potentially exposed population (e.g., residents at the fencehne to the manufacturing facility). (c) Identify the contact pathway (e.g., ingestion, inhalation, dermal). (d) Identify the exposure medium (e.g., air, water). (e) Enter the exposure point concentration (mg/m' or ppb). Provide ( I ) average and (2) high-end estimates. Parts a) and b) It is not expected that the general population would come into contact with the application equipment and any emission due to equipment failure or leakage would be initially confined to a small arca in close proximity to the equipment. then readily dispersed. This would put the exposure of the general population close to zero. Parts c) and d) inhalation through the air Part c) Confidential Mark (X) this box if this page contains CBI Form 1265-07 (Revised 09/2011)