Association of California Water Agencies (ACWA). 1996. Cost of Compliance with Potential Arsenic MCLs. Prepared by Kennedy/Jenks Consultants. November 1996 [W-99-16-III-C-1]
Other documents for the same rulemaking (all, by stage)
References: 11 extracted, 0 linked to papers
Geology, State of California, 1977. Otton, J.K., D.E. Owen, R.F. Dubiel, G.M. Reimer, and S.L. Szarzi, Geologic Radon Potential of
EPA Region 9," USGS Open File Report 93-292-I, 1993.
Raucher, R.S., ET. Castillo, A. Dixon, W. Breffle, D. Waldman, and J.A. Drago, Estimating the Cost of Compliance with Drinking Water Standards, A User's Guide for Developing or Auditing Estimates of Water Supply Regulatory Compliance Costs, AWWARF Final Report, 1995.
Zar, Jerrold H., Biostatistical Analysis, Prentice-Hall, Inc., 1974. A.17 P.100
APPENDIX B SYSTEM CONFIGURATION AND RESULTS FROM 1995 ACWA WATER QUALITY SURVEY
OBJECTIVE This appendix provides back-up for the System Characterization (Chapter 3) of public water systems (PWSs) in California that must comply with a revised federal arsenic MCL. The appendix also describes the methods used to characterize the existing drinking water system configurations from state compliance databases and the 1995 ACWA Water Quality Survey.
Appendix A. PICME also identified water sources and installed treatments for systems with greater than 200 service connections, but did not have groupings, capacity or annual production data for groundwater or surface water treatment plants. Information from the state databases was not sufficient to identify sources from systems with fewer than 200 connections or to characterize all sources with respect to capacity, annual production, or grouping. To accomplish these tasks, this study built upon information from previous cost of compliance studies, and administered the ACWA 1995 Water Quality Survey. Results from the survey were used to fill in data gaps for the remaining systems. The next few sections describe the integration of the various sources of information to characterize California public water systems..
SYSTEM AND SOURCE IDENTIFICATION Public Water Systems Through PICME and LPA, 4,454 California PWSs were identified as regulated systems. Each of these community or non-transient non-community systems is required to comply with USEPA arsenic MCLs, and has 15 or more service connections or populations of 25 or more. California also has approximately 4,416 water systems which serve transient populations, or serve fewer than 25 people with fewer than 15 service connections. These water systems are not required to comply with USEPA arsenic MCLs and are excluded from this analysis. Based on information in PICME, of the 4,454 potentially impacted water systems, 3,925 utilities use only groundwater, 109 use a combination of surface and groundwater sources, and 138 only treat surface water. Many of the remaining 282 utilities buy treated water from a wholesaler rather than operate their own surface water treatment plant. The overall total of utilities using some groundwater is 4,034. The median utility serves a population between 100 and 500. While the majority of public water systems use groundwater and serve populations less than 500, the majority of California residents are supplied by large surface water systems that serves populations of 10,000 or more. Large surface water systems account for much less than 10 percent of all systems yet provide water to almost 70 percent of the state population (DHS 1993b). Water Sources
SYSTEM CONFIGURATION This section explains how information from the PICME, LPA, the ACWA 1995 Water Quality
Survey, and other sources were used to characterize California PWSs with respect to source capacities and annual production, centralization, and installed treatment technologies. Estimating the Capacities and Annual Productions of the Affected Facilities Treatment plant and well design capacities are required to determine the capital cost of treatment facilities and operational costs. Annual productions are important for some components of annual operations and maintenance costs. Unfortunately, the PICME database does not contain information about design capacities or productions for wells or surface water treatment plants. Where possible, the ACWA 1995 Water Quality Survey, the
AWWA Water Industry Database (W1DB) and information from the Kennedy/Jenks files were used to determine design capacity. For other cases, however, facility capacity had to be estimated. Approximately 50 percent of the surface water and 80 percent of the well design capacities were estimated. The bases of these estimates are described below. Groundwater Source Capacities Data from the ACWA 1995 Water Quality Survey and earlier surveys provided capacity information for approximately 20 percent of the affected wells. The remaining wells were assigned capacities based on this distribution of wells capacities for systems within the same population categories. Groundwater sources were divided into 9 size capacity categories for cost estimation. Table B1 presents the capacity ranges, average capacities, and percentage of sources that fall within each capacity category. Table B-2 shows how the sources are distributed between population categories. Table B-1 Summary of Capacity Categories and Well Distribution for PWSs with Population > 500 from ACWA 1995 Water Quality Survey Range of Capacities (gpm) Capacity Used for Cost Estimation 1,000 1,500 2,000 2,500 4,000 Total 50-100 100-350 350 - 800 800-1,250 1,250-1750 1,750-2,250 2,250 - 3,000 >3000 N.A. Average Capacity (gpm) 1,022 1,505 2,005 2,639 3,791 N.A. Number of Wells Percentage of Wells 1,627