State Regulations - Florida [W-02-01-61901]
Other documents for the same rulemaking (all, by stage)
References: 97 extracted, 0 linked to papers
M. (1990). Sludge dewatering and mineralization in reed bed systems. In P. F. Cooper and B. C. Findlater (Eds.), Constructed wetlands in water pollution control (pp. 245-256). New York: Pergamon.
M. (1993). Biological sludge drying in constructed wetlands. In G. A. Moshiri (Ed.), Constructed wetlands for water quality improvements (pp. 549-558). Boca Raton, FL: Lewis.
C. (1981). An air-operated fish culture system with water-reuse and subsurface silos. In L. J. Allen and E. C. Kinney (Eds.), Bio-Engineering symposium for fish culture (FCS Publ. 1) (pp. 131-137). Bethesda, MD: American Fisheries Society.
M. (1991). Impact of aquaculture on water resources. In D. E. Brune and J. R. Tomasso (Eds.), Aquaculture and water quality (pp. 568-591). Baton Rouge, LA: World Aquaculture Society.
B. (1994). Reuse of sludge and minor wastewater residuals. Boca Raton, FL: Lewis.
J. (1995). Natural systems for waste management and treatment (2nd ed.). New York: McGraw-Hill, Inc.
Riggle, D. (1991). Reed bed system for sludge. Biocvcle. 32. 129-145.
Ronhovde, J. (2000). Personal communication. Sterner Aquatech AS, N-1405 Langhus.
T. (1996). Engineering design of a water reuse system. In R. C. Summerfelt (Ed.), Walleye culture manual (pp. 277-309). Ames, IA: North Central Regional Aquaculture Center Publication Office, Iowa State University.
T. (1999). Waste-handling systems. In CIGR (Series Ed.) and F. Wheaton (Volume Ed.), CIGR handbook of agricultural engineering: Volume II. Aquacultural engineering (pp. 309-350). St. Jospeh, MI: American Society of Agricultural Engineers.
Summerfelt, S. T., Davidson, J., Waldrop, T., and Tsukuda, S. (2000a). A partial-reuse system for coldwater aquaculture. In G. S. Libey and M. B. Timmons (Eds.), Proceedings of the third international conference on recirculating aquaculture (pp. 167-175). Blacksburg, VA: Virginia Polytechnic Institute and State University.
B. (2000b). Hydrodynamics in the 'Cornell-type' dual-drain tank. In G. S. Libey and M. B. Timmons (Eds.), Proceedings of the third international conference on recirculating aquaculture (pp. 160-166). Blacksburg, VA: Virginia Polytechnic Institute and State University.
L. (1991). Wastewater engineering: Treatment, disposal, and reuse (3 rd ed.). New York: McGraw-Hill, Inc.
Tchobanoglous, G., and Eliassen, R. (1970). Filtration of treated sewage effluent. Journal of Sanitation Engineering Division ASCE, 96, No. SA2.
B. (2000). Aquaculture engineering-experiences with recirculating aquaculture system technology, part 1. Aquaculture Magazine 26( 1). 52-56.
J. (1998). Review of circular tank technology and management. Aquacultural Engineering 18. 51-69.
Ulgenes, Y., and Eikebrokk, B. (1992). Undersokelse av utslippsmengder, renseutstyr og slambehandlingsmetoder ved settefiskanlegg. Hovedrapport. SINTEF NHL report no. STF60 A93051. SINTEF: Trondheim, Norway. (In Norwegian)
USDA Natural Resources Conservation Service [NRCS]. (1996). Agricultural waste management field handbook. Washington, DC: author.
Warrer-Hansen, I. (1982). Methods of treatment of wastewater from trout farming. In J. Alabaster (ed.). Report of the EIFAC workshop on fish-farm effluents (pp. 113-121). Rome:UNFAO.
J. (1972). Physicochemical processes for water quality control. New York: John Wiley and Sons.
Wedekind, H., Knosche, R., and Gothling, U. (1995). Treatment of trout farm effluents by drum filtration with different mesh sizes. In: C-S. Lee (Ed.), Aquaculture in Eastern European Countries. Stara Zagora, Bulgaria.
Westers, H. (1991). Operational waste management in aquaculture effluents. In C. B. Cowey and C. Y. Cho (Eds.), Nutritional strategies and aquaculture waste (pp. 231-238). Guelph, Ontario: Fish Nutrition Research
H. (2000). Settling velocity characterization of aquacultural solids. Aquacultural Engineering. 21. 233-246.
Wright, P., Grajko, W., Lake, D., Perschke, S., Schenne, J., Sullivan, D., Tillapaugh, B., Timothy, B., and Weaver, D. (1999). Earthen manure storage design considerations. Ithaca, NY: Natural Resource, Agriculture, and Engineering Service.
James M. Ebeling The Freshwater Institute P.O. Box 1889
DOC - dissolved organic carbon 4 INACTIVATION OF FISH PATHOGENS 4.1 UV irradiation Data on inactivation offish pathogenic bacteria and viruses by UV irradiation are summarized in Table 2. The figures show that UV doses of 2 - 6 mWs cm"2 reduce the viable count of the studied species by 99.9% or more in laboratory batch experiments. However, under more realistic continuous flow experiments with particles present, considerably higher doses are required to obtain a high degree of inactivation (Bullock and Stuckey 1977, Liltved and Cripps 1999). Therefore, inactivation doses obtained in the laboratory should be used with caution in predicting dose requirements in actual situations. Studies by Torgersen (1998) indicate that the ISA virus is susceptible to UV light. Loss of infectivity was demonstrated when infected tissue homogenate was subjected to doses of 4-10 mWs cm"2. In contrast, ttie'TPN virus, a non-occluded birnavirus responsible of infectious
AES Workshop: Intensive Fin-Fish Systems and Technologies P.66 pancreas necrosis in Atlantic salmon, is UV resistant. A dose of 122 mWs cm"2 was required to obtain 99.9% reduction in virus titer in brackish water (Liltved et al. 1995). Doses in the same order of magnitude have been experienced in studies conducted by Japanese investigators (Sako and Sorimachi 1985, Yoshimizu et al. 1986). In spite of the resistance of IPNV, UV irradiation has become the method of choice for disinfection of supply water in Norwegian smolt farms where the UV units are designed for bacterial inactivation. The IPNV will pass through these installations unaltered since the doses applied are far too low for inactivation. Due to the substantial losses from IPN outbreaks, preventive measures such as upgrading of existing UV units to IPNV inactivating capacity when using water from sources suspected to carry infective levels of IPNV should be considered. Such upgrading will require at least a 5-fold increase in
UV dose compared with the present 25 mWs cm"2 requirement. Even higher doses have been required to reduce the infectivity of the Asian shrimp baculoviruses to zero. The mid-gut glad necrosis virus (BMNV) and the WSBV were inactivated by doses of 410 and 900 mWs cm'2, respectively (Momayama 1989, Chang et al. 1998). Due to the extreme resistance of these viruses and the excessive waterflows required, UV irradiation is not a feasible method for baculovirus inactivation in Asian grow-out shrimp farms. However, high efficiency
UV units could be suitable for hatchery and nursery ponds with limited water use. Particle protection mechanism has been indicated for bacteria associated with Anemia fragments, due to lack of a dose dependent inactivation in the dose range of 10-22 mWs cm"2 (Fig.l) (Liltved and Cripps 1999). The results obtained suggest a possible transmission offish pathogenic bacteria to land-based aquacultural installations, even if the influent water is disinfected by UV irradiation. It was further demonstrated that prefiltration improved bacterial removal. Mesh sizes of 50 um resulted in more than 5 logio removal efficiency, indicating that influent water to aquacultural systems should be filtered to remove crustaceal fragments and other particles capable harbouring bacteria before disinfection.
AES Workshop: Intensive Fin-Fish Systems and Technologies P.67 Table 2. Inactivation c ffish pathogenic microorganisms in water by UV irradiation Percent removal UVdose (mWs cm 2 ) Temp. 99.99 99.9-100 21-24 99.9 2.9-5.5 99.999 Room temp. 99.9 99.9 99.9 Reactor type Comments References Continuos flow No info about water quality Kimura et al. 1976 Continuos flow Bullock and Stuckey 1977 Batch
UV trans.: 95% 1cm Turbidity: 4JTU No info about water quality Sako and Sorimachi 1985 Brackish Batch 15 %o salinity Liltved etal. 1995 Batch Fish farm effluent Batch
TSS 22 mg/l TOC 9.8 mg/l Liltved and Landfald 1995 Liltved and Landfald 1995 1.2-3.2 Batch 99.9 8.5-13.4 Batch <99.9 Seawater Continuos flow Liltved and Cripps 1999
IPNV 100-150 Batch IPNV 99,9 Sako and Sorimachi 1985 Yoshimizu el al. 1986 Sako and Sorimachi 1985 Yoshimizu et al. 1986 Liltved etal. 1995 Organism Water Bacteria A. salmonicida A. punctata A. hydrophila V. anguillarum P. fluorescens A. salmonicida A. hydrophila V. anguillarum P. fluorescens Y. ruckeri A. salmonicida V. anguillarum V. ordalii A. salmonicida V. anguillarum V. salmonicida Y. ruckeri A. salmonicida A. salmonicida A. salmonicida V. anguillarum Y. ruckeri A. salmonicida V. anguillarum Y. ruckeri 12.5 Spring water Liltved and Landfald 1996 With photoreactivation and liquid holding recovery Liltved and Landfald 1996 Viruses 4-10 Loss of infectivity
ISA-virus Room temp. Brackish Batch Tissue homogenate Virus stock solution Batch Batch 15 %o salinity Torgersen 1998 20 ppt seawater Chang etal. 1998 Absence of toxic residues and reaction products, low costs when treating high quality water, easy operation and maintenance, and minimal space requirements, are main advantages of UV irradiation. Fouling of the quartz sleeves must be dealt with on a regular basis, normally by mechanical or chemical cleaning. The major disadvantage of this method in aquacultural applications is the inefficiency against important fish pathogenic viruses. This might limit the use
UV-dose (mWs cm") Figure 1. The effect of pre-filtration on survival of aerobic bacteria in UV irradiated water containing Anemia fragments 4.1.1 Photoreactivation Photoreactivation and dark repair have not previously been studied in fish pathogenic bacteria. In the present study it was demonstrated that A. salmonicida, V anguillarum and Y. ruckeri are able to repair UV damage both in the presence and absence of visible light (Liltved and Landfald 1996, Liltved and Landfald 2000). Photoreactivation improved survival of these fish pathogens to about the same degree as has been found for common water quality indicator bacteria under similar experimental conditions (Harris et al. 1987). At a light intensity typical of indoor aquacultural facilities (1500 lx), 10- to 1000-fold recoveries were obtained within the first two hours in A. salmonicida, V. anguillarum and Y. ruckeri (Liltved and Landfald 1996). Photoreactivation was essentially completed within 4-6 hours. These trials were conducted in the laboratory with bacterial cells suspended in buffers.
UV irradiation followed by high-intensity light repair was also studied under more realistic conditions. UV exposed A. salmonicida and V. anguillarum suspended in their natural water qualities, respectively, demonstrated a less pronounced, but more rapid photoreactivation at sunlight intensities than in lamplight. Only 20 minutes and 1 hour respectively was required for complete reactivation (Liltved and Landfald 2000). These trials show that even in indoor facilities with elevated light fluxes, water retention times and/or temperatures, recovery processes may elevate the number of viable bacteria after irradiation. More rapid reactivation may occur in UV disinfected supply water and wastewater if exposed to sunlight in outdoor tanks or water recipients.
TSS 22 mg/l TOC 9.8 mg/l Batch Natural waters Wedemeyer and Nelson 1977 Liltved and Landfald 1995 Liltved and Landfald 1995 Liltved et al. 1995 Sugita ei al. 1992 Ozone demand free Wedemeyer and Nelson 1977 Colberg and Lingg 1978 Ozone demand free Ozone demand free Natural waters Wedemeyer et al. 1978 Wedemeyer et al. 1978 Liltved etal. 1995 Viruses
WSBV Arimoto et al. 1996 Chang et al. 1998 •Concentrations recorded as total residual oxidants (TRO)
WSBV (Liltved et al. 1995, Chang et al. 1998). As viral diseases have become a major threat in worldwide aquaculture, the virucidal properties of ozone will certainly be more valued in the future, both in intake and effluent water disinfection. Ozone-treated water has also proven useful for washing fertilized eggs (Arimoto et al. 1996) and for reducing or eliminating potential pathogens associated with live prey such as rotifers in marine larval production systems (Davis and Arnold 1997, Theisen et al. 1998).
Beveridge, M C M B 1996 Cage Aquaculture. 2™' Edition. 346pp. Fishing News Books, Oxford. ISBN 0-85238-235-9.
Technion, Faculty of Mechanical Engineering, Haifa,, 13-16 October 1998.
Gunnarsson, J , 1988 Bridgestone Hi-seas fish cage design and use. in "Aquaculture Engineering: Technologies for the Future" I Chem E Symposium series no 111, EFCE Publication Series No 66, ISBN 0 85295 226 0; Institution of Chemical Engineers, UK.
Muir, J F and Basurco, B (eds), 2000 Mediterranean offshore mariculture. Options mediterranes, Serie B Etudes et recherches. No 30, 215pp, CIHEAM, Zaragoza.
Polke, M 1996 (ed) Open Ocean Aquaculture. Proceedings of an International Conference, May 8-10 1996, Portland, Maine. New Hampshire/Maine Sea Grant College Program Rpt #
UNHMP-CP-SG-96-9. 640 pp Willlnsky, M D and Huguenin, J E 1996 Conceptual, engineering and operational frameworks for submersible cage systems, pp 41-92 Polke, M 1 9 % (ed) Open Ocean Aquaculture. Proceedings of an International Conference, May 8-10 1996,
AES Workshop: Intensive Fin-Fish Systems and Technologies P.98 Intensification of Pond Aquaculture Pond Production (Catfish) D. E. Brune1, G. Schwartz1, J. A. Collier1, T. E. Schwedler2, A. G. Eversole 2 'Dept. Of Agricultural & Biological Engineering Dept. Of Aquaculture, Fisheries & Wildlife Clemson University, Clemson, SC Year Yield Reference 1958 1300 lbs/acre Auburn University 1969 1100 lbs/acre ave 1500 lbs/acre max Stickney 1997 3200 lbs/acre ave 4000-5000 lbs/acre typical
Tucker, et. al. Aquaculture practices have evolved over the last 30 years. Pond catfish production has been increased from around 1000-1500 lb/acre in the 1960's to typical production of 4000-5000 lb/acres today. Typical Pond