{"document":{"doc_id":162356,"source":"docket_item","org":"EPA","doc_type":"report","title":"PTAC Canadian Upstream Oil & Gas Eco-Efficiency Equipment and Operations Handbook. Accessible Online at: https://www.PTAC.org","date":"2026-10-29","url":"https://www.regulations.gov/document/EPA-HQ-OAR-2025-0163-0166","source_native_id":"EPA-HQ-OAR-2025-0163-0166","status":"fetched","abstract":null,"action":null},"dockets":["EPA-HQ-OAR-2025-0163"],"rins":["RIN 2060-AW73"],"related":[{"doc_id":22123,"source":"ria","org":"EPA","doc_type":"regulatory_impact_analysis","title":"Oil and Gas NSPS EG Climate Review Additional Reconsideration, Proposal","date":"2026-01-01"},{"doc_id":3207,"source":"fr_rule","org":"ENVIRONMENTAL PROTECTION AGENCY","doc_type":"Proposed Rule","title":"Additional Reconsideration Standards of Performance for New, Reconstructed, and Modified Sources and Emissions Guidelines for Existing Sources: Oil and Natural Gas Sector Climate Review","date":"2026-10-29"},{"doc_id":11292,"source":"ria","org":"EPA","doc_type":"regulatory_impact_analysis","title":"U.S. EPA. (2023). Regulatory Impact Analysis of the Standards of Performance for New, Reconstructed, and Modified Sources and Emissions Guidelines for Existing Sources: Oil and Natural Gas Sector Climate Review. December 2023. EPA-452/R-23-013","date":"2026-10-29"},{"doc_id":11296,"source":"ria","org":"EPA","doc_type":"regulatory_impact_analysis","title":"Industry Profile Scripts and Workbook: Section 2 of the Regulatory Impact Analysis for the Additional Reconsideration Standards of Performance for New, Reconstructed, and Modified Sources and Emissions Guidelines for Existing Sources: Oil and Natural Gas Sector Climate Review, Proposal Docket EPA-HQ-OAR-2025–0163","date":"2026-10-29"},{"doc_id":11298,"source":"ria","org":"EPA","doc_type":"regulatory_impact_analysis","title":"9.3-4.2026 OIRA Review. Passback Number 1 Email Correspondence from OMB to EPA Transmitting Comments on Draft Reconsideration 2 NPRM Preamble and RIA","date":"2026-10-29"},{"doc_id":11302,"source":"ria","org":"EPA","doc_type":"regulatory_impact_analysis","title":"Regulatory Impact Analysis for the Additional Reconsideration Standards of Performance for New, Reconstructed, and Modified Sources and Emissions Guidelines for Existing Sources: Oil and Natural Gas Sector Climate Review","date":"2026-10-29"},{"doc_id":11304,"source":"ria","org":"EPA","doc_type":"regulatory_impact_analysis","title":"Air Quality Modeling Technical Support Document for Regulatory Impact Analysis for the Additional Reconsideration Standards of Performance for New, Reconstructed, and Modified Sources and Emissions Guidelines for Existing Sources: Oil and Natural Gas Sector Climate Review","date":"2026-10-29"},{"doc_id":11315,"source":"ria","org":"EPA","doc_type":"economic_analysis","title":"Publication. Budiyanto, et. al. (2023). Techno‑economic analysis of natural gas distribution using a small‑scale liquefied natural gas carrier. Scientific Reports. (2023) 13:22900  \nhttps://doi.org/10.1038/s41598-023-50155-8.","date":"2026-10-29"},{"doc_id":11334,"source":"ria","org":"EPA","doc_type":"benefit_cost_analysis","title":"Report. Cost-Benefit Analysis. Colorado Department of Public Health & Environment, AQCC. (2019).  Regulation Number 7 Control of Ozone via Ozone Precursors and Control of Hydrocarbons via Oil and Gas Emissions. November 29, 2019","date":"2026-10-29"},{"doc_id":127254,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"E.O. 12866 Meeting Memorandum and Meeting Materials. Re: Additional Reconsideration Standards of Performance for New, Reconstructed, and Modified Sources and Emissions Guidelines for Existing Sources: Oil and Natural Gas Sector Climate Review/2060-AW73/EPA","date":"2026-10-29"},{"doc_id":127255,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"OIRA Review. 9.28-9.29.2026 EPA Email Correspondence with OMB Transmitting Passback No. 1 Response Files to OMB for Review. Batches 1 and 2.","date":"2026-10-29"},{"doc_id":127256,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"8.26-10.6.2026 OIRA Review Additional EPA and OMB Email Correspondence-No Files Transmitted Primary file: 8.26.2026 Email: Request for a call  2060-AW73","date":"2026-10-29"},{"doc_id":127257,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"10.6.2026 OIRA Review. Email Correspondence Between EPA and OMB. OMB Transmission of Additional NPRM Preamble Comments. Passback Number 2 Batch 2.","date":"2026-10-29"},{"doc_id":127258,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"10.5.2026 OIRA Review. Email Correspondence Between EPA and OMB. OMB Transmission of NPRM Preamble Comments. Passback Number 2 Batch 2.","date":"2026-10-29"},{"doc_id":127259,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"10.8.2026 OIRA Review. Email Correspondence between EPA and OMB. OMB Comments and EPA Responses to Comments on the Draft NPRM Reconsideration Two Preamble and Regulatory Impacts Analyses Documents","date":"2026-10-29"},{"doc_id":127260,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"10.9.2026 OIRA Review Conclusion of OIRA Review of the EPA NPRM, “Additional Reconsideration of Standards of Performance for New, Reconstructed, and Modified Sources and Emissions Guidelines for Existing Sources: Oil and Natural Gas Sector Climate Review”, RIN 2060 AW73. Clearance Files and OMB Email to EPA Concluding Review","date":"2026-10-29"},{"doc_id":127261,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"10.15.2026 EPA/OAR and OMB/OIRA Correspondence and EPA/OAR Transmission of Changes to the Reconsideration 2 NPRM Preamble and Regulatory Impacts Analysis","date":"2026-10-29"},{"doc_id":162339,"source":"docket_item","org":"EPA","doc_type":"report","title":"California Air Resources Board (CARB). 2020 Final Report. Measurement of Produced Water Air Emissions from Crude Oil and Natural Gas Operations. May 2020.","date":"2026-10-29"},{"doc_id":162340,"source":"docket_item","org":"EPA","doc_type":"report","title":"Report. Bowers, et al. Quantification of Methane Emissions from Marginal - Low Production Rate. April 28, 2022. US DOE NETL Award Number DE‐FE0031702","date":"2026-10-29"},{"doc_id":162341,"source":"docket_item","org":"EPA","doc_type":"data","title":"Excel Sheet Attachment to Memorandum (Summary of Spreadsheets used for Tank Battery Impact Estimates) to Docket EPA-HQ-OAR-2021-0317-0039. Attachment 21 (Model Tank Battery with Emiss Distribution) November 1, 2021","date":"2026-10-29"},{"doc_id":162342,"source":"docket_item","org":"EPA","doc_type":"report","title":"Report. Kim, et. al. Challenges and Potential Solutions in GTL FPSO Process Design for Monetization of Offshore Stranded Gas.","date":"2026-10-29"},{"doc_id":162343,"source":"docket_item","org":"EPA","doc_type":"report","title":"Report U.S. EPA. (2006). Lessons Learned from Natural Gas STAR Partners Replacing Gas-Assisted Glycol Pumps with Electric Pumps. October 2006","date":"2026-10-29"},{"doc_id":162344,"source":"docket_item","org":"EPA","doc_type":"report","title":"U.S. EIA. Distribution of Wells by Production Rate Document - December 2025","date":"2026-10-29"},{"doc_id":162345,"source":"docket_item","org":"EPA","doc_type":"report","title":"2.20.2026. American Petroleum Institute. Pneumatics and Storage Vessels Potential Capital Cost Saving Analysis","date":"2026-10-29"},{"doc_id":162346,"source":"docket_item","org":"EPA","doc_type":"report","title":"U.S. EPA Website Capture. Oil and Natural Gas. Advanced Methane Technology Alternative Test Method (Accessed 6/11/2026)","date":"2026-10-29"},{"doc_id":162347,"source":"docket_item","org":"EPA","doc_type":"report","title":"7.22.2025 API-AXP C-North Dakota Petroleum Council Storage Tank Safety Issue Survey Summary Slides","date":"2026-10-29"},{"doc_id":162348,"source":"docket_item","org":"EPA","doc_type":"report","title":"Vyawahare, et. al. (2023). Hydrogen Production from Methane Pyrolysis. October 2023.","date":"2026-10-29"},{"doc_id":162350,"source":"docket_item","org":"EPA","doc_type":"report","title":"U.S. Energy Information Administration. The Distribution of U.S. Oil and Natural Gas Wells by Production Rate with Data Through 2024. December 2025. Full Report. U.S. Department of Energy","date":"2026-10-29"},{"doc_id":162351,"source":"docket_item","org":"EPA","doc_type":"report","title":"Report. Tractebel Engineering S.A. World Bank Group (2025). Mini / Micro LNG for commercialization of small volumes of associated gas Mini Micro LNG. October 2025","date":"2026-10-29"},{"doc_id":162352,"source":"docket_item","org":"EPA","doc_type":"report","title":"Report by Carbon Limits AS (Prepared for CATF). Zero emission technologies for pneumatic controllers in the USA.  Applicability and cost effectiveness. August 2016.","date":"2026-10-29"},{"doc_id":162353,"source":"docket_item","org":"EPA","doc_type":"data","title":"EPA Forms 5340-1D. Super-Emitter Program Third-Party Notification Forms Submitted Under Paperwork Reduction Act 44. U.S.C. section 3501. OMB Control No. 20260-0721. Seven Reports","date":"2026-10-29"},{"doc_id":162354,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Memorandum to EPA Docket No. EPA-HQ-OAR-2025-0163. Comparative Analysis of Quarterly AVO and Semiannual OGI. August 31, 2026","date":"2026-10-29"},{"doc_id":162355,"source":"docket_item","org":"EPA","doc_type":"report","title":"Section 5.3 - Air Quality Modeling - AQ SABAQS EPA-HQ-OAR-2025-0163 readme","date":"2026-10-29"},{"doc_id":162357,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Memorandum to Docket EPA-HQ-OAR-2025-0163. Revised Analysis for Process Controllers and Pumps for Reconsideration of New Source Performance Standards (40 CFR 60, Subpart OOOOb  and Emissions Guidelines 40 CFR  60, Subpart OOOOc. August 28, 2026","date":"2026-10-29"},{"doc_id":162358,"source":"docket_item","org":"EPA","doc_type":"report","title":"Section 3 - Equilibrium Modeling EPA-HQ-OAR-2025-0163 readme","date":"2026-10-29"},{"doc_id":162359,"source":"docket_item","org":"EPA","doc_type":"report","title":"Kathairos Solutions, Inc. (2026). What is the Best Indicator of Pneumatic Venting: Device Count or Production Levels?  June 29, 2026","date":"2026-10-29"},{"doc_id":162360,"source":"docket_item","org":"EPA","doc_type":"report","title":"Report. California Air Resources Board (CARB). (2020). Measurement of Produced Water Air Emissions from Crude Oil and Natural Gas Operations. Final Report. May 2020","date":"2026-10-29"},{"doc_id":162361,"source":"docket_item","org":"EPA","doc_type":"data","title":"Draft NSPS OOOOb and EG OOOOc, Sections 60.5422b and 60.5422c. Semiannual Report Spreadsheet Template. Version 1.03 (DRAFT). Date: 9-11-2026","date":"2026-10-29"},{"doc_id":162363,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"2.20.2026 Email Correspondence from API to EPA. Transmission of NSPS OOOOb and EG OOOOc Pneumatics and Tanks Cost Analysis.","date":"2026-10-29"},{"doc_id":162364,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Memorandum to Docket ID EPA-HQ-OAR-2025-0163. Analysis of Potential BSER Options for Associated Gas. August 28, 2026","date":"2026-10-29"},{"doc_id":162365,"source":"docket_item","org":"EPA","doc_type":"data","title":"Kathairos Solutions (2026) What’s the Best Indicator of Pneumatic Venting: Device Count or Production Levels? May 2026","date":"2026-10-29"},{"doc_id":182962,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Report. U.S. EPA. (2002). EPA Air Pollution Control Cost Manual. Sixth Edition. EPA/452/B-02-001. January 2002","date":"2026-10-29"},{"doc_id":182963,"source":"docket_item","org":"EPA","doc_type":"publication","title":"U.S. EPA Website Capture. Oil and Gas Alternative Test Methods. Alternative Test Method(s) for the New Source Performance Standards and Emission Guidelines for Oil and Natural Gas Operations (Accessed 6/11/2026)","date":"2026-10-29"},{"doc_id":182964,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Publication. Nafees, et. al. (2008). Fischer Tropsch Gas to Liquid Technology (GTL). Presented at the Second International Energy 2030 Conference. Chemical Engineering Program, The Petroleum Institute, Abu Dhabi, U.A.E","date":"2026-10-29"},{"doc_id":182966,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Reconsideration Notice of Proposed Rulemaking Red-Line Strike-Out Changes to NSPSs KKK, OOOO, OOOOa, OOOOb, and OOOOc.","date":"2026-10-29"},{"doc_id":182967,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Federal Register Notices Cited in the 2026 NSPS and EG Reconsideration Proposal Preamble. (6.3.2016 81 FR 35824).","date":"2026-10-29"},{"doc_id":182968,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Publication. Ozowe, et. al. (2023). Recent advances and challenges in gas injection techniques for enhanced oil recovery. Magna Scientia Advanced Research and Reviews, 2023, 09(02). Article DOI: https://doi.org/10.30574/msarr.2023.9.2.0180","date":"2026-10-29"},{"doc_id":182969,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Publication. Duration of super-emitting oil and gas methane sources. Nature communications. (2026) 17:2011. Published online January 24, 2026","date":"2026-10-29"},{"doc_id":182970,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Publication. Chen, et al. 2022. Quantifying Regional Methane Emissions in the New Mexico Permian Basin with a Comprehensive Aerial Survey. Environ. Sci. Technol. (2022) 56 (7): 4317–4323.(Copyrighted)","date":"2026-10-29"},{"doc_id":182971,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Musa, et. al. (2026). Methane Pyrolysis for Low-Carbon Syngas and Methanol. April 2026. https://doi.org/10.3390/gases6020018","date":"2026-10-29"},{"doc_id":182972,"source":"docket_item","org":"EPA","doc_type":"publication","title":"E. Brancaccio. GTL: Small Scale and Modular Technologies for Gas to Liquid Industry. Serintel Srl. Rome (Italy). https://www.oil-gasportal.com/gtl-small-scale-and-modular-technologies-for-gas-to-liquid-industry/?print=pdf.","date":"2026-10-29"},{"doc_id":182974,"source":"docket_item","org":"EPA","doc_type":"publication","title":"U.S. EPA-GRI Report (Prepared for DOE). (1996). Research and Development. Methane Emissions from the Natural Gas Industry. Volume 13: Chemical Injection Pumps. June 199","date":"2026-10-29"},{"doc_id":182978,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Publication. How Quickly Do Oil and Gas Wells ‘‘Water Out’’? Quantifying and Contrasting Water Production Trends. Natural Resources Research, Vol. 33, No. 2, April 2024 https://doi.org/10.1007/s11053-024-10308-6","date":"2026-10-29"},{"doc_id":182980,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Publication. Luck, et al. (2019).  Multiday Measurements of Pneumatic Controller Emissions Reveal the Frequency of Abnormal Emissions Behavior at Natural Gas Gathering Stations. Environ. Sci. Technol. Lett. (2019) 6 (6): 348–352","date":"2026-10-29"},{"doc_id":182982,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Publication. Methane Emissions from Conventional and Unconventional Natural Gas Production Sites in the Marcellus Shale Basin. Environmental Science and Technology. Published: January 29, 2016.","date":"2026-10-29"}],"references":[{"citation_id":1363274,"raw_reference":"Schlumberger. (2017). The Oilfield Glossary: Where the Oil Field Meets the Dictionary. Retrieved July 10, 2017, from http://www.glossary.oilfield.slb.com/","cited_authors":"Schlumberger","cited_year":"2017","cited_title":"The Oilfield Glossary: Where the Oil Field Meets the Dictionary","cited_venue":null,"cited_doi":null,"cited_url":"http://www.glossary.oilfield.slb.com/","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363275,"raw_reference":"ACCESSIBLE ONLINE AT: HTTPS://WWW.PTAC.ORG 1.2.2. Treater Burner Management System and Firetube Upgrade July 31, 2017 Description At oil battery sites, heater treaters are used to process primary oil for transport and storage. Some legacy heater treaters use older burners that run at only 20%-40% of full capacity per treater, resulting in energy inefficient operation. While replacing old burners with new re-sized units may be an option, upgrading the burners can be a more cost-effective way to increase energy efficiency. Upgrading the Burner Management System (BMS) and firetubes generally involves two elements: Installing turbulators4 and flue gas recycle lines. Replacing the existing stacks with those with optimal height and diameter to improve draw. These upgrades increase burner efficiency, improve combustion, and reduce emissions. Additional benefits include better oil and water separation, which may allow for an increase in produced oil. Upgraded firetube systems operate at higher combustion efficiency, and the BMS can be programmed for automated sequencing to further decrease fuel gas consumption. Upgraded treaters may consume as much as 14% less fuel gas, with a corresponding reduction in emissions and increase in cost savings. Technology Group","cited_authors":null,"cited_year":null,"cited_title":"ACCESSIBLE ONLINE AT: HTTPS://WWW.PTAC.ORG 1.2.2","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363276,"raw_reference":"ACCESSIBLE ONLINE AT: HTTPS://WWW.PTAC.ORG 1.2.3. Optimization of Natural Gas Fired Burners for Energy Efficiency July 31, 2017 Description Natural-gas fired heaters are used throughout the oil and gas industry for process heating, tank heating and line heating applications. Burner optimization helps ensure efficient use of fuel gas. Typically, the first step in burner optimization is a pre-inspection or pre-audit of the existing burner configuration. This inspection usually involves the completion of a combustion efficiency test and an emissions/exhaust analysis by a qualified service company. The condition of the equipment and the combustion efficiency test should be used to inform the extent of the modifications that can be made to improve energy efficiency, safety and regulatory compliance. One of the most common sources of reduced efficiency is excess air in the combustion process.","cited_authors":null,"cited_year":null,"cited_title":"ACCESSIBLE ONLINE AT: HTTPS://WWW.PTAC.ORG 1.2.3","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363277,"raw_reference":"Callendar, J. (2012, October 22). EnCana's Environmental Innovation Fund . 2012 Towards Clean Energy Production: Emissions Management, Energy Efficiency and CO2 Credits. Calgary. Retrieved from Ptac.org: http://www.ptac.org/events/46","cited_authors":"Callendar, J","cited_year":"2012","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":"http://www.ptac.org/events/46","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363278,"raw_reference":"CETAC-West. (May 2008). Fuel Gas Best Management Practices: Efficient Use of Fuel Gas in Fired Heaters Module 6 of 17. Calgary: Canadian Association of Petroleum Producers. Government of Alberta. (2017, July 14). Carbon levy and rebates. Retrieved from www.alberta.ca: https://www.alberta.ca/climate-carbon-pricing.aspx#p184s1 https://www.alberta.ca/climate-carbon-pricing.aspx#p184s1","cited_authors":"CETAC-West. (May","cited_year":"2008","cited_title":"Fuel Gas Best Management Practices: Efficient Use of Fuel Gas in Fired Heaters Module 6 of 17","cited_venue":null,"cited_doi":null,"cited_url":"www.alberta.ca:","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363279,"raw_reference":"ACCESSIBLE ONLINE AT: HTTPS://WWW.PTAC.ORG Government of Canada. (2017, June 19). Multi-Sector Air Pollutants Regulations (SOR/2016-151). Retrieved from Environment and Climate Change Canada: http://www.ec.gc.ca/lcpecepa/eng/regulations/detailReg.cfm?intReg=220","cited_authors":"ACCESSIBLE ONLINE AT: HTTPS://WWW.PTAC.ORG Government of Canada","cited_year":"2017","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":"http://www.ec.gc.ca/lcpecepa/eng/regulations/detailReg.cfm?intReg=220","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363280,"raw_reference":"Yu, A. (September 2013). Cenovus Energy: Upgrading to Higher Efficiency Burners. COSIA Workshop. Calgary.","cited_authors":"Yu, A. (September","cited_year":"2013","cited_title":"Cenovus Energy: Upgrading to Higher Efficiency Burners","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363281,"raw_reference":"ACCESSIBLE ONLINE AT: HTTPS://WWW.PTAC.ORG 2.1.1. Black Gold Rush Industries Ltd. - Enclosed Vapour Combustor April 26, 2019 Description Black Gold Rush Industries enclosed vapour combustors (EVCs) effectively combust all volatile organic compounds (VOCs), benzene, toluene, ethylbenzene, and xylenes (BTEXs) produced from oil and gas equipment, such as storage tanks, casing gas, dehys, pneumatic devices, pumps or any other low-pressure venting equipment. Black Gold Rush’s EVC is the most effective and economical option to reduce the methane emissions from oil and gas sites. The combustors can be placed within 10m of wells, tanks or existing process equipment and do not require expensive valve train or piping. The patented burner system achieves 99.99% total hydrocarbon destruction with as low as 2oz of pressure. No additional fuel gas, air assist, or power is required. The combustors can be solar-power-operated using a CSA B149.3 compliant burner management system. A small continuous pilot that uses less than 100 scf/d of fuel gas allows for stable combustion of intermittent flows as soon as the vapours enter the combustion chamber. All Black Gold Rush EVCs have been third-party tested and meet or exceed the U.S EPA, AER D-60, and Saskatchewan S-10 / S-20 regulations. Technology Group","cited_authors":null,"cited_year":null,"cited_title":"ACCESSIBLE ONLINE AT: HTTPS://WWW.PTAC.ORG 2.1.1","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363282,"raw_reference":"Alberta Government. (2017, January 25). Quantification Protocol for Greenhouse Gas Emission Reductions from Pneumatic Devices Version 2.0. Retrieved from Alberta Environment and Parks: http://aep.alberta.ca/climate-change/guidelines-legislation/specified-gas-emittersregulation/documents/PneumaticDevices-Jan25-2017.pdf","cited_authors":"Alberta Government","cited_year":"2017","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":"http://aep.alberta.ca/climate-change/guidelines-legislation/specified-gas-emittersregulation/documents/PneumaticDevices-Jan25-2017.pdf","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363283,"raw_reference":"CETAC - West. (May 2008). Fuel Gas Best Management Practices: Efficient Use of Fuel Gas in Chemical Injection Pumps Module 5 of 17. Calgary: Canadian Association of Petroleum Producers. https://www.alberta.ca/climate-leadership-plan.aspx#toc-5 http://news.gc.ca/web/article-en.do?nid=1039219","cited_authors":"CETAC - West. (May","cited_year":"2008","cited_title":"Fuel Gas Best Management Practices: Efficient Use of Fuel Gas in Chemical Injection Pumps Module 5 of 17","cited_venue":null,"cited_doi":null,"cited_url":"https://www.alberta.ca/climate-leadership-plan.aspx#toc-5","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363284,"raw_reference":"Greenpath Energy Ltd. (2016). Pneumatic Pump Alternatives For Cold Weather. British Columbia Oil and Gas Research Innovation Society. Retrieved from http://www.bcogris.ca/sites/default/files/ei2016-07-pneumatic-pump-alternatives-cold-weather-final-report.pdf","cited_authors":"Greenpath Energy Ltd","cited_year":"2016","cited_title":"Pneumatic Pump Alternatives For Cold Weather","cited_venue":null,"cited_doi":null,"cited_url":"http://www.bcogris.ca/sites/default/files/ei2016-07-pneumatic-pump-alternatives-cold-weather-final-report.pdf","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363285,"raw_reference":"Hiebert, S. (July 2016). ConocoPhillips Field GHG Reduction Projects Final Report. ConocoPhillips. Retrieved from http://cetacwest.com/downloads/ConocoPhillips-Final-Report-July-29-2016.pdf","cited_authors":"Hiebert, S. (July","cited_year":"2016","cited_title":"ConocoPhillips Field GHG Reduction Projects Final Report","cited_venue":null,"cited_doi":null,"cited_url":"http://cetacwest.com/downloads/ConocoPhillips-Final-Report-July-29-2016.pdf","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363286,"raw_reference":"Prasino Group. (2013). Final Report for Determining Bleed Rates for Pneumatic Devices in British Columbia. Retrieved from http://www.capopenergy.com/uploads/1/1/7/8/11781696/prasino_pneumatic_ghg_ef_final_re port.pdf Zero GHG Venting Controls for Separators. (2017, July 14). Retrieved from Calscan Solutions website: http://www.calscan.net/solutions_ZeroGHGVenting.html","cited_authors":"Prasino Group","cited_year":"2013","cited_title":"Final Report for Determining Bleed Rates for Pneumatic Devices in British Columbia","cited_venue":null,"cited_doi":null,"cited_url":"http://www.capopenergy.com/uploads/1/1/7/8/11781696/prasino_pneumatic_ghg_ef_final_re","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363287,"raw_reference":"Alberta Government. (2017, January 25). Quantification Protocol for Greenhouse Gas Emission Reductions from Pneumatic Devices Version 2.0. Retrieved from Alberta Environment and Parks: http://aep.alberta.ca/climate-change/guidelines-legislation/specified-gas-emittersregulation/documents/PneumaticDevices-Jan25-2017.pdf https://www.alberta.ca/climate-leadership-plan.aspx#toc-5 http://news.gc.ca/web/article-en.do?nid=1039219","cited_authors":"Alberta Government","cited_year":"2017","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":"http://aep.alberta.ca/climate-change/guidelines-legislation/specified-gas-emittersregulation/documents/PneumaticDevices-Jan25-2017.pdf","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363288,"raw_reference":"CETAC - West. (2008). Fuel Gas Best Management Practices: Efficient Use of Fuel Gas in Pneumatic Instruments Module 3 of 17. Calgary: Canadian Association of Petroleum Producers CAPP. Retrieved from http://www.capp.ca/publications-and-statistics/publications/137304","cited_authors":"CETAC - West","cited_year":"2008","cited_title":"Fuel Gas Best Management Practices: Efficient Use of Fuel Gas in Pneumatic Instruments Module 3 of 17","cited_venue":null,"cited_doi":null,"cited_url":"http://www.capp.ca/publications-and-statistics/publications/137304","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363289,"raw_reference":"Hiebert, S. (July 2016). ConocoPhillips Field GHG Reduction Projects Final Report. ConocoPhillips. Retrieved from http://cetacwest.com/downloads/ConocoPhillips-Final-Report-July-29-2016.pdf (2006). Lessons Learned from Natural Gas Star Partners: Options for Reducing Methane Emissions From Pneumatic Devices In The Natural Gas Industry. Washington, DC: United States Environmental Protection Agency.","cited_authors":"Hiebert, S. (July","cited_year":"2016","cited_title":"ConocoPhillips Field GHG Reduction Projects Final Report","cited_venue":null,"cited_doi":null,"cited_url":"http://cetacwest.com/downloads/ConocoPhillips-Final-Report-July-29-2016.pdf","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363290,"raw_reference":"Prasino Group. (2013). Final Report for Determining Bleed Rates for Pneumatic Devices in British Columbia. Retrieved from http://www.capopenergy.com/uploads/1/1/7/8/11781696/prasino_pneumatic_ghg_ef_final_re port.pdf","cited_authors":"Prasino Group","cited_year":"2013","cited_title":"Final Report for Determining Bleed Rates for Pneumatic Devices in British Columbia","cited_venue":null,"cited_doi":null,"cited_url":"http://www.capopenergy.com/uploads/1/1/7/8/11781696/prasino_pneumatic_ghg_ef_final_re","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363291,"raw_reference":"IGIA sites require that sufficient electricity is available onsite to power the added electrical loads from the instrument air compressor, desiccant dryers, metering/communications equipment, and any added building lighting or electric heaters. Three-phase power is usually necessary to run an air compressor, so smaller sites with single-phase power will likely require electrical upgrades to accommodate the new instrument air package. On January 23, 2014 Alberta Environment updated the GWP of methane to be 25 (from 21). For further details refer to this bulletin: http://esrd.alberta.ca/focus/alberta-and-climate-change/regulating-greenhouse-gasemissions/alberta-based-offset-credit-system/offset-credit-systemprotocols/documents/MemoOnGlobalWarmingPotentials-Feb2014.pdf http://www.eagle-pc.com/industrial/indus_doc_comp.htm","cited_authors":null,"cited_year":null,"cited_title":"IGIA sites require that sufficient electricity is available onsite to power the added electrical loads from the instrument air compressor, desiccant dryers, metering/communications equipment, and any added building lighting or electric heaters","cited_venue":null,"cited_doi":null,"cited_url":"http://esrd.alberta.ca/focus/alberta-and-climate-change/regulating-greenhouse-gasemissions/alberta-based-offset-credit-system/offset-credit-systemprotocols/documents/MemoOnGlobalWarmingPotentials-Feb2014.pdf","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363292,"raw_reference":"Aggregation Project. (2017, July 14). Retrieved from Alberta Carbon Registries Website: https://www.csaregistries.ca/albertacarbonregistries/eor_project.cfm?id=%23-%234M%0A Alberta Emissions Offset Registry Project Details: Encana Corporation's Instrument Air Conversion Aggregation Project Phase 2. (2017, July 14). Retrieved from Alberta Carbon Registries Website: https://www.csaregistries.ca/albertacarbonregistries/eor_project.cfm?id=%23-S4M%0A Alberta Emissions Offset Registry Project Details: Encana Instrument Air Conversion at Strathmore Phase 1. (2017, July 14). Retrieved from Alberta Carbon Registries Website: https://www.csaregistries.ca/albertacarbonregistries/eor_project.cfm?id=%233%20J%0A&sort=id","cited_authors":"Aggregation Project","cited_year":"2017","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":"https://www.csaregistries.ca/albertacarbonregistries/eor_project.cfm?id=%23-%234M%0A","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363293,"raw_reference":"Callendar, J. (November 2014). Challenges and Opportunities in the Upstream Oil and Gas Sector. 2014","cited_authors":"Callendar, J. (November","cited_year":"2014","cited_title":"Challenges and Opportunities in the Upstream Oil and Gas Sector","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363294,"raw_reference":"PTAC Forum Energy Efficiency and Emissions Reduction Technologies. Calgary: PTAC. Retrieved from http://www.ptac.org/events/162 Government of Alberta. (2009). Quantification Protocol for Instrument Gas to Instrument Air Conversion in Process Control Systems Version 1.0. Government of Alberta. Retrieved from http://aep.alberta.ca/climate-change/guidelines-legislation/specified-gas-emittersregulation/documents/ProtocolInstrumentGasAirControl-Oct2009.pdf (2006). Lessons Learned from Natural Gas STAR Partners: Convert Gas Pneumatic Controls to Instrument Air. Washington, DC: United States Environmental Protection Agency.","cited_authors":"PTAC Forum Energy Efficiency and Emissions Reduction Technologies. Calgary: PTAC. Retrieved from http://www.ptac.org/events/162 Government of Alberta","cited_year":"2009","cited_title":"Quantification Protocol for Instrument Gas to Instrument Air Conversion in Process Control Systems Version 1.0","cited_venue":null,"cited_doi":null,"cited_url":"http://www.ptac.org/events/162","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363295,"raw_reference":"CETAC - West. (May 2008). Fuel Gas Best Management Practices: Efficient Use of Fuel Gas in Chemical Injection Pumps Module 5 of 17. Calgary: Canadian Association of Petroleum Producers.","cited_authors":"CETAC - West. (May","cited_year":"2008","cited_title":"Fuel Gas Best Management Practices: Efficient Use of Fuel Gas in Chemical Injection Pumps Module 5 of 17","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363296,"raw_reference":"Hiebert, S. (July 2016). ConocoPhillips Field GHG Reduction Projects Final Report. ConocoPhillips. Retrieved from http://cetacwest.com/downloads/ConocoPhillips-Final-Report-July-29-2016.pdf https://www.alberta.ca/climate-leadership-plan.aspx#toc-5 http://news.gc.ca/web/article-en.do?nid=1039219","cited_authors":"Hiebert, S. (July","cited_year":"2016","cited_title":"ConocoPhillips Field GHG Reduction Projects Final Report","cited_venue":null,"cited_doi":null,"cited_url":"http://cetacwest.com/downloads/ConocoPhillips-Final-Report-July-29-2016.pdf","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363297,"raw_reference":"Prasino Group. (2013). Final Report for Determining Bleed Rates for Pneumatic Devices in British Columbia. Retrieved from http://www.capopenergy.com/uploads/1/1/7/8/11781696/prasino_pneumatic_ghg_ef_final_re port.pdf (2011). PRO Fact Sheet No. 202: Convert Natural Gas-Driven Chemical Pumps. Washington, DC: Environmental Protection Agency. Retrieved from https://www.epa.gov/sites/production/files/201606/documents/convertgasdrivenchemicalpumpstoinstrumentair.pdf","cited_authors":"Prasino Group","cited_year":"2013","cited_title":"Final Report for Determining Bleed Rates for Pneumatic Devices in British Columbia","cited_venue":null,"cited_doi":null,"cited_url":"http://www.capopenergy.com/uploads/1/1/7/8/11781696/prasino_pneumatic_ghg_ef_final_re","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363298,"raw_reference":"ACCESSIBLE ONLINE AT: HTTPS://WWW.PTAC.ORG 4.2.2. Cold Weather Pump Alternatives July 31, 2017 Description Emissions from natural gas driven pneumatic pumps have been identified as a significant source of methane emissions. However, the cold Canadian climate poses challenges with respect to availability of sunlight, high-pressure, and reliability of alternative pump technologies. A study of several pump technologies, including operator surveys, determined that alternatives to gas-driven pumps are both available and effective. However, the installation of properly-sized systems is critical to the success of alternative pumps, and the preferred pump technology differs by production type and site-specifics. The study determined the preferred alternative pump type for six common site scenarios. Production Type","cited_authors":null,"cited_year":null,"cited_title":"ACCESSIBLE ONLINE AT: HTTPS://WWW.PTAC.ORG 4.2.2","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363299,"raw_reference":"Alberta Government. (2009). Quantification Protocol for Engine Fuel Management and Vent Gas Capture Projects. Government of Alberta. Retrieved from http://aep.alberta.ca/climatechange/guidelines-legislation/specified-gas-emittersregulation/documents/ProtocolEngineFuelVentGasProjects-Oct2009.pdf","cited_authors":"Alberta Government","cited_year":"2009","cited_title":"Quantification Protocol for Engine Fuel Management and Vent Gas Capture Projects","cited_venue":null,"cited_doi":null,"cited_url":"http://aep.alberta.ca/climatechange/guidelines-legislation/specified-gas-emittersregulation/documents/ProtocolEngineFuelVentGasProjects-Oct2009.pdf","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363300,"raw_reference":"Cenovus Energy Inc. (2015). Installation of Air/Fuel Ratio Controllers and Vent Gas Capture on Engines Final Report. Climate Change and Emissions Management Corporation. Retrieved from http://eralberta.ca/wp-content/uploads/2017/05/E100338-Cenovus-Final-Report.pdf https://www.alberta.ca/climate-carbon-pricing.aspx#p184s1","cited_authors":"Cenovus Energy Inc","cited_year":"2015","cited_title":"Installation of Air/Fuel Ratio Controllers and Vent Gas Capture on Engines Final Report","cited_venue":null,"cited_doi":null,"cited_url":"http://eralberta.ca/wp-content/uploads/2017/05/E100338-Cenovus-Final-Report.pdf","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363301,"raw_reference":"CETAC-West. (2008). Fuel Gas Best Management Practices: Efficient Use of Fuel Gas in Engines Module 7 of 17. Calgary: Canadian Association of Petroleum Producers CAPP. Retrieved from http://www.capp.ca/publications-and-statistics/publications/137314 Government of Canada. (2017, June 19). Multi-Sector Air Pollutants Regulations (SOR/2016-151). Retrieved from Environment and Climate Change Canada: http://www.ec.gc.ca/lcpecepa/eng/regulations/detailReg.cfm?intReg=220","cited_authors":"CETAC-West","cited_year":"2008","cited_title":"Fuel Gas Best Management Practices: Efficient Use of Fuel Gas in Engines Module 7 of 17","cited_venue":null,"cited_doi":null,"cited_url":"http://www.capp.ca/publications-and-statistics/publications/137314","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363302,"raw_reference":"ACCESSIBLE ONLINE AT: HTTPS://WWW.PTAC.ORG 5.2.6. Vent Gas Capture (VGC) Systems July 31, 2017 Description Significant natural gas is vented to the atmosphere during the course of normal oil and gas operations. The capture and combustion of vented natural gas (a “VGC Project”), consisting of primarily methane, reduces greenhouse gas emissions by combusting methane and converting it to carbon dioxide, water vapour, and other combustion by-products. A portion of the vent gas may still be emitted to the atmosphere if the collection system is not 100% effective (e.g. downtime, not all sources tied in, partial collection down to low pressures etc.) or if the combustion device is not 100% effective at destructing the methane. A typical vent gas capture project includes piping, controls, regulators and a combustion device.","cited_authors":null,"cited_year":null,"cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363303,"raw_reference":"Project. (2017, July 14). Retrieved from Alberta Carbon Registries Website: https://www.csaregistries.ca/albertacarbonregistries/eor_project.cfm?id=%23%2D%234B%0A Alberta Emissions Offset Registry Project Details: Encana Corporation's Vent Gas Capture Aggregation Project Phase 2. (2017, July 14). Retrieved from Alberta Carbon Registries Website: https://www.csaregistries.ca/albertacarbonregistries/eor_project.cfm?id=%23%2DS4L%0A Alberta Emissions Offset Registry Project Details: Encana Corporation's Vent Gas Capture Aggregation Project Phase 3. (2017, July 14). Retrieved from Alberta Carbon Registries Website: https://www.csaregistries.ca/albertacarbonregistries/eor_project.cfm?id=%23%2DSDO%0A","cited_authors":"Project","cited_year":"2017","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":"https://www.csaregistries.ca/albertacarbonregistries/eor_project.cfm?id=%23%2D%234B%0A","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363304,"raw_reference":"Callendar, J. (2012, October 22). EnCana's Environmental Innovation Fund . 2012 Towards Clean Energy Production: Emissions Management, Energy Efficiency and CO2 Credits. Calgary. Retrieved from ptac.org: http://www.ptac.org/events/46","cited_authors":"Callendar, J","cited_year":"2012","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":"http://www.ptac.org/events/46","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363305,"raw_reference":"Cenovus Energy Inc. (2015). Installation of Air/Fuel Ratio Controllers and Vent Gas Capture on Engines Final Report. Climate Change and Emissions Management Corporation. Retrieved from http://eralberta.ca/wp-content/uploads/2017/05/E100338-Cenovus-Final-Report.pdf https://www.alberta.ca/climate-leadership-plan.aspx#toc-5 http://news.gc.ca/web/article-en.do?nid=1039219 Alberta only.","cited_authors":"Cenovus Energy Inc","cited_year":"2015","cited_title":"Installation of Air/Fuel Ratio Controllers and Vent Gas Capture on Engines Final Report","cited_venue":null,"cited_doi":null,"cited_url":"http://eralberta.ca/wp-content/uploads/2017/05/E100338-Cenovus-Final-Report.pdf","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363306,"raw_reference":"ACCESSIBLE ONLINE AT: HTTPS://WWW.PTAC.ORG 6.1.1. Spartan Controls Ltd. – SlipStream® GTS – DeHy April 26, 2019 Description The SlipStream® GTS-DeHy is a vent capture system designed specifically to capture vented hydrocarbons from condensate tanks, glycol dehydrators, and oil storage tanks. These captured hydrocarbons are instead redirected for use as supplementary fuel, significantly reducing greenhouse gas (GHG) emissions and destroying volatile organic compounds (VOCs) like benzene, toluene, ethylbenzene, and xylene (BTEX). The GTS-DeHy easily integrates into new or existing installations, eliminating the need for stand-alone combustors or costly vent gas compressors. On a typical glycol dehydrator application, the GTS-DeHy routes the captured vent gases to either the main burner or auxiliary burner depending on heat demand, and has a BTEX destruction efficiency of 99.5% approved by the AER. Technology Group Dehydration Units and Gas Treatment – Facilities Design and Equipment Site Applicability Oil and gas facilities; sweet service Emissions Reduction and Energy Efficiency","cited_authors":null,"cited_year":null,"cited_title":"ACCESSIBLE ONLINE AT: HTTPS://WWW.PTAC.ORG 6.1.1","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363307,"raw_reference":"Alberta Energy Regulator. (2013, January 22). Directive 039. Retrieved from Alberta Energy Regulator Rules and Directives: https://www.aer.ca/rules-and-regulations/directives/directive-039","cited_authors":"Alberta Energy Regulator","cited_year":"2013","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":"https://www.aer.ca/rules-and-regulations/directives/directive-039","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363308,"raw_reference":"Alberta Upstream Petroleum Research. (2017). Development of a Model to Predict Benzene Emissions from Glycol Dehydrators with Condensation Tanks: Project Continuation. Retrieved from Alberta Upstream Petroleum Reasearch - Air: http://auprf.ptac.org/air/development-of-a-model-topredict-benzene-emissions-from-glycol-dehydrators-with-condensation-tanks-projectcontinuation-potential-release-into-the-atmosphere-of-additives-used-in-the-hydraulic-fract/ Process Ecology Inc. (February 17, 2016). Development of a model to predict benzene emissions from glycol dehydrators with condensation tanks Revision 4. Calgary: Alberta Upstream Petroleum Research. Retrieved from http://auprf.ptac.org/wp-content/uploads/2015/11/15-ARPC-01Development-of-a-Model-to-Predict-Benzene-Emissions-from-Glyc...-1.pdf","cited_authors":"Alberta Upstream Petroleum Research","cited_year":"2017","cited_title":"Development of a Model to Predict Benzene Emissions from Glycol Dehydrators with Condensation Tanks: Project Continuation","cited_venue":null,"cited_doi":null,"cited_url":"http://auprf.ptac.org/air/development-of-a-model-topredict-benzene-emissions-from-glycol-dehydrators-with-condensation-tanks-projectcontinuation-potential-release-into-the-atmosphere-of-additives-used-in-the-hydraulic-fract/","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363309,"raw_reference":"Peachey, B. (April 30, 2015). Heavy Oil Vent Mitigation Options - 2015 Second Edition. Calgary: Environment Canada Environmental Stewardship Branch. Retrieved from https://www.ptac.org/wp-content/uploads/2017/07/Heavy-Oil-Venting-2nd-Ed-2015.pdf Saskatchewan Ministry of the Economy. (November, 2015). Saskatchewan Upstream Petroleum Industry Associated Gas Conservation Directive S-10. Government of Saskatchewan. (July, 2016). ST 60 Crude Oil and Crude Bitumen Batteries Monthly Flaring, Venting, and Production Data. Alberta Energy Regulator.","cited_authors":"Peachey, B. (April 30","cited_year":"2015","cited_title":"Heavy Oil Vent Mitigation Options - 2015 Second Edition","cited_venue":null,"cited_doi":null,"cited_url":"https://www.ptac.org/wp-content/uploads/2017/07/Heavy-Oil-Venting-2nd-Ed-2015.pdf","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363310,"raw_reference":"Peachey, B. (April 30, 2015). Heavy Oil Vent Mitigation Options - 2015 Second Edition. Calgary: Environment Canada Environmental Stewardship Branch. Retrieved from https://www.ptac.org/wp-content/uploads/2017/07/Heavy-Oil-Venting-2nd-Ed-2015.pdf","cited_authors":"Peachey, B. (April 30","cited_year":"2015","cited_title":"Heavy Oil Vent Mitigation Options - 2015 Second Edition","cited_venue":null,"cited_doi":null,"cited_url":"https://www.ptac.org/wp-content/uploads/2017/07/Heavy-Oil-Venting-2nd-Ed-2015.pdf","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363311,"raw_reference":"Alberta Energy Regulator. (2016, March 31). Directive 017. Retrieved from Alberta Energy Regulator Website: https://www.aer.ca/documents/directives/Directive017.pdf Directive 060. (2016, March 22). Retrieved from Alberta Energy Regulator Website: https://www.aer.ca/rules-and-regulations/directives/directive-060","cited_authors":"Alberta Energy Regulator","cited_year":"2016","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":"https://www.aer.ca/documents/directives/Directive017.pdf","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363312,"raw_reference":"New Paradigm Engineering Ltd. (2017). Information on Venting Emissions Quantification and Control Options at Upstream Crude Oil Facilities - Appendix A. Calgary: Environment Canada. Retrieved from https://www.ptac.org/wp-content/uploads/2017/07/Appendix-A-Env-Can-Review-ofCHOPS-Vent-Standard-20170331-Final.pdf","cited_authors":"New Paradigm Engineering Ltd","cited_year":"2017","cited_title":"Information on Venting Emissions Quantification and Control Options at Upstream Crude Oil Facilities - Appendix A. Calgary: Environment Canada","cited_venue":null,"cited_doi":null,"cited_url":"https://www.ptac.org/wp-content/uploads/2017/07/Appendix-A-Env-Can-Review-ofCHOPS-Vent-Standard-20170331-Final.pdf","ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363313,"raw_reference":"New Paradigm Engineering Ltd. (2017). Information on Venting Emissions Quantification and Control Options at Upstream Crude Oil Facilities - Appendix B. Calgary: Environment Canada. Retrieved from https://www.ptac.org/wp-content/uploads/2017/07/Appendix-B-Env-Can-Review-ofDirective-60-and-017-20170331.pdf New Paradigm Engineering Ltd. (November 2004). Conventional Heavy Oil Vent Quantification Standards. Calgary: Petroleum Technology Alliance Canada. Retrieved from https://www.ptac.org/npe-2004-cho-vent-quantification-standards/","cited_authors":"New Paradigm Engineering Ltd","cited_year":"2017","cited_title":"Information on Venting Emissions Quantification and Control Options at Upstream Crude Oil Facilities - Appendix B. Calgary: Environment Canada","cited_venue":null,"cited_doi":null,"cited_url":"https://www.ptac.org/wp-content/uploads/2017/07/Appendix-B-Env-Can-Review-ofDirective-60-and-017-20170331.pdf","ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363314,"raw_reference":"Peachey, B. (April 30, 2015). Heavy Oil Vent Mitigation Options - 2015 Second Edition. Calgary: Environment Canada Environmental Stewardship Branch. Retrieved from https://www.ptac.org/wp-content/uploads/2017/07/Heavy-Oil-Venting-2nd-Ed-2015.pdf Saskatchewan Ministry of the Economy. (2015, November). Saskatchewan Upstream Petroleum Industry Associated Gas Conservation Directive S-10. Retrieved from Government of Saskatchewan Publications Saskatchewan: http://publications.gov.sk.ca/documents/310/85153-Directive%20S10%20Saskatchewan%20Upstream%20Petroleum%20Industry%20Associated%20Gas%20Conser vation%20Directive.pdf","cited_authors":"Peachey, B. (April 30","cited_year":"2015","cited_title":"Heavy Oil Vent Mitigation Options - 2015 Second Edition","cited_venue":null,"cited_doi":null,"cited_url":"https://www.ptac.org/wp-content/uploads/2017/07/Heavy-Oil-Venting-2nd-Ed-2015.pdf","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363315,"raw_reference":"Peachey, Bruce. Heavy Oil Vent Mitigation Options - 2015 Second Edition. Calgary: Environment Canada Environmental Stewardship Branch, April 30, 2015. <https://www.ptac.org/wpcontent/uploads/2017/07/Heavy-Oil-Venting-2nd-Ed-2015.pdf>.","cited_authors":"Peachey, Bruce. Heavy Oil Vent Mitigation Options - 2015 Second Edition. Calgary: Environment Canada Environmental Stewardship Branch, April 30","cited_year":"2015","cited_title":"<https://www.ptac.org/wpcontent/uploads/2017/07/Heavy-Oil-Venting-2nd-Ed-2015.pdf>","cited_venue":null,"cited_doi":null,"cited_url":"https://www.ptac.org/wpcontent/uploads/2017/07/Heavy-Oil-Venting-2nd-Ed-2015.pdf>","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1363316,"raw_reference":"Clearstone Engineering Ltd. (2017, February 26). Cost Benefit Analysis of Heavy Oil Casing Gas Conservation and Conversion Technologies. Retrieved from AUPRF PTAC Website: http://auprf.ptac.org/wp-content/uploads/2017/06/Report-Flaring-Cost-BenefitAnalysis.v2.0.pdf","cited_authors":"Clearstone Engineering Ltd","cited_year":"2017","cited_title":"February 26)","cited_venue":null,"cited_doi":null,"cited_url":"http://auprf.ptac.org/wp-content/uploads/2017/06/Report-Flaring-Cost-BenefitAnalysis.v2.0.pdf","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null}]}