Policy Replication

Total Inward Leakage Requirements for Respirators

Federal Register2009-10-30 · DEPARTMENT OF HEALTH AND HUMAN SERVICES · Proposed Rule · E9-26008
Notice of proposed rulemaking.

The Centers for Disease Control and Prevention ("CDC") proposes to establish total inward leakage (TIL) requirements for half- mask air-purifying particulate respirators approved by the National Institute for Occupational Safety and Health ("NIOSH") of CDC. The proposed new requirements specify TIL minimum performance requirements and testing to be conducted by NIOSH and respirator manufacturers to demonstrate that these respirators, when selected and used correctly, provide effective respiratory protection to intended users against toxic dusts, mists, fumes, fibers, and biological and infectious aerosols (e.g. influenza A(H5N1), severe acute respiratory syndrome (SARS) coronavirus, and Mycobacterium tuberculosis).

RIN 0920-AA33

Other documents for the same rulemaking (all, by stage)

2009-11-18 Federal RegisterTotal Inward Leakage Requirements for Respirators
2009-12-17 Federal RegisterTotal Inward Leakage Requirements for Respirators
2010-04-20 Federal RegisterTotal Inward Leakage Requirements for Respirators
2010-05-27 Federal RegisterTotal Inward Leakage Requirements for Respirators
2010-10-08 Docket documentHIT Standards Committee Schedule for the Assessment of HIT Policy Committee Recommendation
2017-11-17 Federal RegisterTotal Inward Leakage Requirements for Respirators

References: 11 extracted, 9 linked to papers

Page 1Download these results: CSV · JSON
Coffey C, Lawrence R, Campbell D, Zhuang Z, Calvert C, Jensen P. Fitting Characteristics of Eighteen N95 Filtering Facepiece Respirators. JOEH. 2004;1: 262-271.
Lawrence R, Duling M, Calvert C, and Coffey C. Comparison of Performance of Three Different Types of Respiratory Protection Devices. JOEH. 2006;3:465-474.
NIOSH/BLS [2003]. Respirator usage in private sector firms, 2001. Cincinnati, OH: U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health.
datasetNot linked to a paper · fn 6
Zhuang Z, Bradtmiller B, and Shaffer R.E. New Respirator Fit Test Panels Representing the Current U.S. Civilian Workforce. Journal of Occupational and Environmental Hygiene 2007;4: 647-659.
Zhuang Z, Groce D, Ahlers H, Iskander W, Landsittle D, Guffey S, Benson S, Viscusi D, Shaffer R. Correlation between Respirator Fit and Respirator Fit Test Panel Cells by Respirator Size. Journal of Occupational and Environmental Hygiene. 2008;5: 617-628.
Institute of Medicine. Assessment of the NIOSH Head-and-Face Anthropometric Survey of U.S. Respirator Users. The National Academies Press, Washington, DC (2007).
Eninger R, Honda T, Adhikari A, Heinonen-Tanski H, Reponen T, and Grinshpun S. Filter Performance of N99 and N95 Facepiece Respirators Against Viruses and Ultrafine Particles. Ann. Occup. Hyg. 2008;52(5):385-396.
Willeke K, Qian Y, Donnelly J, Grinshpun S, Ulevicius V. Penetration of Airborne Microorganisms Through a Surgical Mask and a Dust/Mist Respirator. American Industrial Hygiene Association Journal. 1996;57(4):348-355.
Qian Y, Willeke K, Grinshpun S, Donnelly J and Coffey C. Performance of N95 Respirators: Filtration Efficiency for Airborne Microbial and Inert Particles. American Industrial Hygiene Association Journal. 1998;59(2):128-132.
Leigh JP, Romano P, Schenker MB, and Kreiss K. Costs of Occupational COPD and Asthma. Chest. 2002;121:264-272.
These include the use of a condensation nuclei counter, the ability to measure sodium chloride challenge aerosol in the specified size range of 0.02 to 0.06 micrometers, and during measurement, responding linearly to changes in the aerosol concentration, within plus or minus five percent, over the ambient concentration range of 70 to 3,000 particles/cm\3\ and TIL 17 18 Work-related COPD and asthma alone are estimated to cost $6.6 billion annually.\19\ The costs of this rulemaking would be covered by the prevention of a small fraction of a percent of the occupational disease burden associated with workplace respiratory hazards. --------------------------------------------------------------------------- ---------------------------------------------------------------------------
Frost and Sullivan Research Service; http://www.frost.com/prod/servlet/report-brochure published 30 March 2005.
research reportNot linked to a paper · fn 20 · cited link