Policy Replication

AK DEC (2021) Oil and Other Hazardous Substances Pollution Control, 18 AAC 75. State Regulations

Docket document2026-01-06 · EPA · other · EPA-HQ-OW-2024-0592-0559
RIN 2040-AG36 · Docket EPA-HQ-OW-2024-0592

Other documents for the same rulemaking (all, by stage)

2026-01-06 Federal RegisterNational Primary Drinking Water Regulation for Perchlorate
2026-01-06 Regulatory impact analysisUSEPA (2008) Proposed lead NAAQs regulatory impact analysis. Government Report.
2026-01-06 Regulatory impact analysisUSEPA (2025) Economic Analysis of the Proposed Perchlorate National Primary Drinking Water Regulation. Support Document
2026-01-06 Regulatory impact analysisUSEPA (2019) Economic Analysis of the Final Rule to Revise the TSCA Dust-Lead Hazard Standards. Report
2026-01-06 Regulatory impact analysisUSEPA (2024) Economic Analysis for the Final Per- and Polyfluoroalkyl Substances National Primary Drinking Water Regulation. Report
2026-01-06 Docket documentBlute (2012) Technologies and Costs for the Removal Of Perchlorate from Drinking Water. Expert Comments.
2026-01-06 Docket documentOMB (2003) Circular A-4. Memo
2026-01-06 Docket documentEO 12866 (1993) Regulatory Planning and Review. Executive Order
2026-01-06 Docket documentUSEPA (2025) Documentation of OMB Review Under Executive Order 12866 for the Proposed Rule - National Primary Drinking Water Regulation for Perchlorate. Reportof OMB Review 12.10.25
2026-01-06 Docket documentAwata et al. (2017) Association of Dietary Intake and Biomarker Levels of Arsenic, Cadmium, Lead, and Mercury among Asian Populations in the United States: NHANES 2011–2012. Journal Article
2026-01-06 Docket documentSteinmaus et al (2007) Impact of smoking and thiocyanate on perchlorate and thyroid hormone associations in the 2001-2002 national health and nutrition examination survey. Journal Article
2026-01-06 Docket documentUSEPA (2024) Personal communication between Susan Euling and the Total Diet Study staff regarding perchlorate analysis. Memo
2026-01-06 Docket documentBurge and Halden (1999) Nitrate and Perchlorate Removal from Groundwater by Ion Exchange: Pilot Testing and Cost Analysis (No. UCRL-ID-135639). Report
2026-01-06 Docket documentCalEPA (2004) Perchlorate Contamination Treatment Alternatives. Draft Report.
2026-01-06 Docket documentLiang et al. (1998) Investigation of Treatment Options for Perchlorate Removal. Conference Paper
2026-01-06 Docket documentLutes et al. (2010) Final Report: Integrated Ion Exchange Regeneration Process for Drinking Water ESTCP Project ER-0545. Report
2026-01-06 Docket documentYoon, Y. et al ( 2005) Systematic bench‐scale assessment of perchlorate (ClO4−) rejection mechanisms by nanofiltration and ultrafiltration membranes. Journal Article
2026-01-06 Docket documentU.S. Census Bureau (2024) US Census Bureau - United States Population by Age and Sex. Website
2026-01-06 Docket documentSun et al. (2017) Relationship between Subclinical Thyroid Dysfunction and the Risk of Cardiovascular Outcomes: A Systematic Review and Meta-Analysis of Prospective Cohort Studies. Journal Article
2026-01-06 Docket documentBureau of Labor Statistics (2022) May 2022 National Occupational Employment and Wage Estimates. Spreadsheet
2026-01-06 Docket documentDevito el al (2024) Value of Information Case Study on the Human Health and Economic Trade-offs Associated with the Timeliness, Uncertainty, and Costs of the Draft EPA Transcriptomic Assessment Product (ETAP). Report
2026-01-06 Docket documentUS Census Bureau. (2023) Table AVG1. Average Number of People per Household, by Race and Hispanic Origin/1, Marital Status, Age, and Education of Householder: 2023. Spreadsheet
2026-01-06 Docket documentRaucher et al (2019) Developing a New Framework for Household Affordability and Financial Capability Assessment in the Water Sector. Report
2026-01-06 Docket documentRowe et al (2010) Design of cycle 3 of the National Water-Quality Assessment Program, 2013-2023: Part 1: Framework of water-quality issues and potential approaches. Report
2026-01-06 Docket documentIA DNR (2019) Statewide Standards for Contaminants in Soil and Groundwater. Guidance
2026-01-06 Docket documentNDEP (2012) Defining a Perchlorate Drinking Water Standard. Guidance
2026-01-06 Docket documentNDEP (2013) Overview of Las Vegas Valley Perchlorate Remediation Efforts. Presentation
2026-01-06 Docket documentScience Applications International Corporation (2006) WBS Peer Review Response-to-Comment Document: Anion Exchange. Final Draft. Report
2026-01-06 Docket documentDuranceau and Taylor (2011) Chapter 11: Membranes. In: Water Quality & Treatment: A Handbook on Drinking Water. Book Chapter
2026-01-06 Docket documentJung et al. (2022) Serum cholesterol levels and risk of cardiovascular death: A systematic review and a dose-response meta-analysis of prospective cohort studies. Journal Article
2026-01-06 Docket documentSegal et al (2015) AA Conceptual Framework for Evaluating the Interaction of a Chemical and Nonchemical Stressor in Human Health Risk Assessments: A Case Study for Lead and Psychosocial Stress. Journal Article
2026-01-06 Docket documentUSEPA (2005) Guidelines for carcinogen risk assessment. Government Report.
2026-01-06 Docket documentUSEPA (2021) Amitraz. Revised draft human health risk assessment for registration review. Government Report
2026-01-06 Docket documentUSEPA (2022) Review of EPAs analysis to support EPA’s national primary drinking water rulemaking for PFAS. Government Report
2026-01-06 Docket documentCharleston Water (2022) Charleston Water System: Water Rates. Data.
2026-01-06 Docket documentHarding ESE (2001) Final: Phase 2 Treatability Study Report, Aerojet GET E/F Treatment Facility Sacramento, California Report
2026-01-06 Docket documentWastewater Digest (2010) Envirogen Technologies Brings New Treatment System Online for California Hospital Facility. Magazine Article.
2026-01-06 Docket documentWebster and Togna (2009) Final Report: Demonstration of a Full-Scale Fluidized Bed Bioreactor for the Treatment of Perchlorate at Low Concentrations in Groundwater ESTCP Project ER-0543. Report
2026-01-06 Docket documentNSF International (2005) Feasibility of Economically Sustainable Point-of-Use/Point-of-Entry Decentralized Public Water System. Report
2026-01-06 Docket documentPleil and Sobus (2016) Estimating central tendency from a single spot measure: A closed-form solution for lognormally distributed biomarker data for risk assessment at the individual level. Journal Article
2026-01-06 Docket documentRowe et al. (2013) Design of Cycle 3 of the National Water-Quality Assessment Program, 2013-23: Part 2: Science plan for improved water-quality information and management. Report
2026-01-06 Docket documentFlorida Department of the State (2005) Chapter 62-777. Contaminant Cleanup Target Levels. Florida Administrative Code and Florida Administrative Register. State Regulations
2026-01-06 Docket documentMassDEP (2004) Summary Report of the First Low-Level Perchlorate Proficiency Test Study Conducted by the Massachusetts Department of Environmental Protection, August 10, 2004. Report
2026-01-06 Docket documentNCBI (2025) PubChem Compound Summary for CID 516900, Potassium Perchlorate. Webpage
2026-01-06 Docket documentThe Cadmus Group (2025) Perchlorate Laboratory Cost Estimates 2025. Spreadsheet
2026-01-06 Docket documentUSEPA (2020) Reductions of Perchlorate in Drinking Water. Report
2026-01-06 Docket documentATSDR (2008) Toxicological Profile for Perchlorates. Technical Report
2026-01-06 Docket documentUSEPA (1998) Assessment of thyroid follicular cell tumors. Government Report.
2026-01-06 Docket documentSpringborn Laboratories (1998) A 90-day drinking water toxicity study in rats with ammonium perchlorate - amended final report. Technical Report
2026-01-06 Docket documentBull et al. (2004) Perchlorate in Drinking Water: A Science and Policy Review. Report
2026-01-06 Docket documentBrown (2019) Final Report: Full-Scale Fixed-Bed Biological Perchlorate Destruction Demonstration, Construction of a Fixed Bed Bioreactor Wellhead Treatment System. Report
2026-01-06 Docket documentUSDOD (2008a) Final Report: Direct Fixed-Bed Biological Perchlorate Destruction Demonstration ESTCP Project ER-0544. Report.
2026-01-06 Docket documentWHO (2025) The global health observatory: Women of reproductive age (15-49 years) population (thousands). Website
2026-01-06 Docket documentUSEPA (2000) Geometries and Characteristics of Public Water Systems. Report
2026-01-06 Docket documentBureau of Labor Statistics (2023) National Occupational Employment and Wage Estimates, United States, BLS SOC Code 19-2041, "State Government, excluding schools and hospitals - Environmental Scientists and Specialists, Including Health Occupational Employment Statistics, Webpage
2026-01-06 Docket documentUSEPA (2004) The Standardized Monitoring Framework: A Quick Reference Guide. Factsheet
2026-01-06 Docket documentLieberman et al (2010) Evaluation of potential for monitored natural attenuation of perchlorate in groundwater. Report
2026-01-06 Docket documentASTSWMO (2011) Perchlorate Policy Update: Final. Report
2026-01-06 Docket documentDasgupta et al. (2006) Perchlorate in the United States. Analysis of Relative Source Contributions to the Food Chain. Journal Article
2026-01-06 Docket documentHatzinger et al (2016) Passive Biobarrier for Treating Co-mingled Perchlorate and RDX in Groundwater at an Active Range. Report

References: 14 extracted, 0 linked to papers

Page 1Download these results: CSV · JSON
ENVIRONMENTAL CONSERVATION (c) No later than December 30, 2007, the owner or operator shall ensure that measures for controlling corrosion in flow lines are undertaken, including, at a minimum, (1) a corrosion monitoring and control program consistent with Chapter VIII of Pipeline Transportation Systems for Liquid Hydrocarbons and Other Liquids (ASME B31.42002) adopted by reference in (b)(1) of this section; (2) unless a more stringent requirement is set out in this section, external corrosion control of buried or submerged flow lines consistent with NACE International’s Standard Recommended Practice-Control of External Corrosion on Underground or Submerged
research reportNot linked to a paper · refsec
Metallic Piping Systems, 2002 Edition (NACE, RP0169-2002), adopted by reference; (3) external corrosion control of aboveground flow lines by the application of a protective coating, by the use of corrosion-resistant alloys or by another method approved by the department, unless the operator demonstrates by test, investigation, or experience appropriate to the environment of the flow line segment, that the anticipated extent of corrosion will not affect the flow line’s fitness for service; and (4) a program designed to minimize internal corrosion, including, as appropriate, one or more of the following: (A) removal of foreign material by scraping or pigging; (B) treatment of residual water or dehydration; (C) injection of inhibitors, biocides, or other chemical agents; (D) removal of dissolved gases by chemical or mechanical means; (E) gas blanketing; (F) continuous internal coating or lining; or (G) another method approved by the department; and (d) No later than December 30, 2007, the operator shall (1) completely contain the entire circumference of the flow line and provide the interstitial space with a leak detection system approved by the department; or (2) have in place a preventative maintenance program that ensures the continued operational reliability of any flow line system component affecting quality, safety, and pollution prevention; the owner or operator shall ensure that the program, Register 240, January 2022
research reportNot linked to a paper · refsec
Code, Inspection, Repair, Alteration, and Rerating of In-service Piping Systems, Second Edition (API 570), adopted by reference in (d)(2) of this section; (3) “removed from service” means not in regular use for the service intended and not included in a regular maintenance and inspection program in accordance with (c) and (d) of this section. (4) “submerged” means located below the surface of waters of the state. (Eff.12/30/2006, Register 180; am 3/23/2017, Register 221) Authority:
research reportNot linked to a paper · refsec
Street NW, Washington, DC 20005-4070; phone (202) 682-8000; fax (303) 397-2740; website: http://www.api-ec.api.org. 18 AAC 75.055. Leak detection, monitoring, and operating requirements for crude oil transmission pipelines. (a) A crude oil transmission pipeline must be equipped with a leak detection system capable of promptly detecting a leak, including (1) if technically feasible, the continuous capability to detect a daily discharge equal to not more than one percent of daily throughput; (2) flow verification through an accounting method, at least once every 24 hours; (3) for a remote pipeline not otherwise directly accessible, weekly aerial surveillance, unless precluded by safety or weather conditions. (b) The owner or operator of a crude oil transmission pipeline shall ensure that the incoming flow of oil can be completely stopped within one hour after detection of a discharge. (c) If aboveground oil storage tanks are present at the crude oil transmission pipeline facility, the owner or operator shall meet the applicable requirements of 18 AAC 75.065, 18 AAC 75.066 and 18 AAC 75.075. (d) For facility oil piping connected to or associated with the main crude oil transmission pipeline, the owner or operator shall meet the requirements of 18 AAC 75.080. (Eff. 5/14/92, Register 122; am 12/30/2006, Register 180) Register 240, January 2022 Authority:
research reportNot linked to a paper · refsec · cited link
AS 46.04.070 18 AAC 75.065. Field-constructed aboveground oil storage tank requirements. (a) Unless the owner or operator must comply with a more stringent requirement set out in this section, the owner or operator of an oil terminal, crude oil pipeline, exploration, or production facility shall maintain and inspect each field-constructed aboveground oil storage tank consistent with the requirements, as appropriate of American Petroleum Institute’s (API) (1) Tank Inspection, Repair, Alteration, and Reconstruction, Fifth Edition, November 2014, Addendum 1, April 2018, and Addendum 2, May 2020 (API 653), adopted by reference; or (2) Installation, Operation, Maintenance, Inspection, and Repair of Tanks in Production Service, Sixth Edition, March 2020 (API STD 12R1) adopted by reference. (b) Inspection intervals for a field-constructed aboveground oil storage tank (1) may be reduced by the department 30 years; bolted; (A) for a field-constructed aboveground oil storage tanks older than (B) for a field-constructed aboveground oil storage tank that is riveted or (C) for a field-constructed aboveground oil storage tanks with a demonstrated structural, corrosion, or foundation problems; or (D) after a significant seismic event; (2) may be extended if a request to extend an initial internal tank inspection interval beyond 10 years is submitted to the department for review and is approved; the request must document that it is based on Table 6.1 of Tank Inspection, Repair,
datasetNot linked to a paper · refsec
Alteration, and Reconstruction (API 653), adopted by reference in (a) of this section; and (3) may be based upon risk-based inspection, as specified in Section 6.4.2.2.2 of Tank Inspection, Repair, Alteration, and Reconstruction, (API 653), adopted by reference in (a) of this section; the assessment must be signed by a registered engineer, and the inspection interval may not exceed 30 years. (c) An onshore elevated field-constructed aboveground oil storage tank whose configuration allows external inspection of more than 50 percent of the tank bottom is not required to undergo an internal inspection if Register 240, January 2022
research reportNot linked to a paper · refsec
Alteration, and Reconstruction, (API 653), adopted by reference in (a) of this section. (f) A field-constructed aboveground oil storage tanks served by an internal steam heating systems must be designed to control leakage through defective heating coils. Condensate lines must be monitored, passed through an oil separating device, or passed through a retention system. (g) An internal lining system installed and used to control corrosion or to meet the requirements of (h) of this section, must be installed in accordance with American Petroleum Institute’s (API). (1) Lining of Aboveground Petroleum Tank Bottoms, First Edition, 1991, (API
research reportNot linked to a paper · refsec
RP 652) adopted by reference, for internal lining systems installed before December 30, 2008;
research reportNot linked to a paper · refsec
Tanks, Fourth Edition, September 2014 (API RP 651), adopted by reference, with the exception that these requirements do not apply to elevated tanks, a cathodic protection system must be Register 240, January 2022
research reportNot linked to a paper · refsec
ENVIRONMENTAL CONSERVATION (i) designed by a corrosion expert; (ii) installed under the supervision of a corrosion expert; (iii) installed, operated, and maintained in accordance with Application of Cathodic Protection to Control External Corrosion of Carbon Steel On-Grade Storage Tank Bottoms (NACE SP0193-2016), adopted by reference in (h) of this section; a corrosion expert or qualified cathodic protection tester shall perform a cathodic protection survey specified under that standard; or (B) a corrosion control system approved by the department as an alternate to the cathodic protection system described in (A) of this paragraph, unless determined not necessary by an evaluation conducted by a corrosion expert consistent with Chapter 5 of the American Petroleum Institute’s (API) Cathodic Protection of Aboveground Petroleum Storage Tanks, Fourth Edition, September 2014 (API RP 651), adopted by reference in (A) of this paragraph. (Eff. 5/14/92, Register 122; am 5/26/2004, Register 170; am 12/30/2006, Register 180; am 3/23/2017, Register 221; am 11/18/2021, Register 240) Authority:
research reportNot linked to a paper · refsec
Washington, DC 20005-4070; phone (202) 682-8000; fax (303) 397-2740; website: http://www.api.org ; NACE International Headquarters, 15835 Park Ten Place, Houston, Texas 77084; phone (281) 228-6200; fax (281) 228-6300; website: http://www.nace.org. As of Register 209 (April 2014), and acting under AS 44.62.125(b)(6), the regulations attorney made technical revisions to 18 AAC 75.065(d) and (i). 18 AAC 75.066. Shop-fabricated aboveground oil storage tanks. (a) The owner or operator of a shop-fabricated aboveground oil storage tank placed in service: this section; (1) on or before December 30, 2008 shall meet the requirements of (f) - (h) of (2) after December 30, 2008 and before May 17, 2022 shall meet the requirements of (b) – (h) of this section; or section. (3) on or after May 17, 2022 shall meet the requirements of (c) – (i) of this Register 240, January 2022
research reportNot linked to a paper · refsec · cited link
Distribution Piping Systems, 2003 Edition (ASME B31.8-2003), adopted by reference; (4) another equivalent standard approved by the department. (d) The owner or operator shall ensure that buried metallic facility oil piping placed in service between May 14, 1992 and December 30, 2008, is protected from corrosion by installing protective coating and cathodic protection appropriate for local soil conditions and is of all welded construction with no clamped, threaded, or similar connections for lines larger than a one inch nominal pipe size. (e) The owner or operator shall ensure that buried facility oil piping placed in service after December 30, 2008 (1) is of all welded construction with no clamped, threaded, or similar connections for lines larger than one inch nominal pipe size; and department, is (2) unless constructed of a corrosion-resistant material approved by the Register 240, January 2022
research reportNot linked to a paper · refsec
ENVIRONMENTAL CONSERVATION (A) protected from corrosion by installing protective coating; and (B) cathodically protected in accordance with (f) of this section. (f) The owner or operator shall ensure that, after December 30, 2008, cathodic protection systems installed on facility oil piping are (1) consistent with NACE International’s, Standard Recommended PracticeControl of External Corrosion on Underground or Submerged Metallic Piping Systems, 2002 Edition (NACE RP0169-2002), adopted by reference; (2) designed by a corrosion expert; and (3) installed under the supervision of a corrosion expert; (g) The owner or operator shall ensure that, if a piping segment of a buried facility oil piping installation is exposed for any reason, the segment is carefully examined, for damaged coating or corroded piping in accordance with Section 9.2.6 of Piping Inspection Code,
research reportNot linked to a paper · refsec
Inspection, Repair, Alteration, and Rerating of In-service Piping Systems (API 570), adopted by reference in (j) of this section, if active corrosion is found during that examination, of this section. (1) the owner or operator shall implement actions for control of future corrosion; (2) significant repairs or replacements must meet the requirements of (c) and (e) (h) An owner or operator or a buried facility oil piping installation of metallic construction without cathodic protection shall ensure that the piping (1) is electrically inspected by a corrosion expert for active corrosion at least once every three years, but with intervals between inspections not exceeding 39 months; and (2) in areas in which active corrosion is found, cathodically protected in accordance with (d) or (f) of this section, as appropriate; (i) The owner or operator shall ensure that aboveground facility oil piping is supported consistent with the requirements of Paragraph 321 of Process Piping, (ASME B31.3-2004), adopted by reference in (c) of this section. (j) After December 30, 2007, unless the owner or operator must comply with a more stringent requirement set out in this section, the owner or operator shall ensure that all facility oil piping is maintained and inspected under Register 240, January 2022
research reportNot linked to a paper · refsec