{"document":{"doc_id":152719,"source":"docket_item","org":"EPA","doc_type":"publication","title":"EPA Air Pollution Control Cost Manual, Sixth Edition, EPA/42/B-02-001, January 2002","date":"2019-08-16","url":"https://www.regulations.gov/document/EPA-HQ-OAR-2002-0083-0839","source_native_id":"EPA-HQ-OAR-2002-0083-0839","status":"fetched","abstract":null,"action":null},"dockets":["EPA-HQ-OAR-2002-0083"],"rins":["RIN 2060-AV82","RIN 2060-AE48","RIN 2060-AT03","FR 2025-21787","RIN 2060-AW69"],"related":[{"doc_id":156931,"source":"docket_item","org":"EPA","doc_type":"other","title":"Legacy Index for Docket A-2000-44","date":"2001-02-02"},{"doc_id":20902,"source":"fr_rule","org":"ENVIRONMENTAL PROTECTION AGENCY","doc_type":"Proposed Rule","title":"National Emission Standards for Hazardous Air Pollutants: Integrated Iron and Steel Manufacturing","date":"2001-07-13"},{"doc_id":135223,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"OMB 83I Form for ICR No. 2003.02 OMB No. 2060 - New Collection","date":"2003-02-28"},{"doc_id":156930,"source":"docket_item","org":"EPA","doc_type":"other","title":"Supporting Statement  for ICR No. 2003.02 OMB No. 2060 - New Collection","date":"2003-02-28"},{"doc_id":19646,"source":"fr_rule","org":"ENVIRONMENTAL PROTECTION AGENCY","doc_type":"Rule","title":"National Emission Standards for Hazardous Air Pollutants: Integrated Iron and Steel Manufacturing","date":"2003-05-20"},{"doc_id":156865,"source":"docket_item","org":"EPA","doc_type":"other","title":"Settlement in the United States Court of Appeals for the District of Columbia Circuit in the Matter of AK Steel Corporation vs. USEPA, Case # 03-1207","date":"2005-09-13"},{"doc_id":156866,"source":"docket_item","org":"EPA","doc_type":"other","title":"Discussion Paper on Performance Test-Based Opacity Limits in the Iron & Steel MACT (Maximum Achievable Control Technology) Rule","date":"2005-09-13"},{"doc_id":156867,"source":"docket_item","org":"EPA","doc_type":"other","title":"Petitioners' Preliminary and Non-Binding Statement of Issues to be Raised","date":"2005-09-13"},{"doc_id":156868,"source":"docket_item","org":"EPA","doc_type":"other","title":"Proposed Alternative to Iron & Steel MACT (Maximum Achieveable Control Technology) Performance Test-Based Opacity Limits","date":"2005-09-13"},{"doc_id":156869,"source":"docket_item","org":"EPA","doc_type":"other","title":"Settlement of Iron & Steel MACT (Maximum Achievable Control Technology) Issues","date":"2005-09-13"},{"doc_id":156870,"source":"docket_item","org":"EPA","doc_type":"other","title":"Iron and Seel MACT (Maximum Achievable Control Technology) Standard for BOF ESP Conceptual Draft - COMS Corrective Action Trigger","date":"2005-09-13"},{"doc_id":159892,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Letter to Steve Fruh, USEPA,/Office of Air Quality, Planning & Standards/Emission Standards Division from John L. Wittenborn and Russell S. Frye, Collier Shannon Scott PLLC re: MACT Standards","date":"2005-09-13"},{"doc_id":159893,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Notes from telephone conversation between Steve Fruh, USEPA, Metals Group; Phil Mulrine, USEPA. Metals Group; Steve Silverman, USEPA, Office of Genera Counsel; Andy Doyle, US Department Justice; Marvin Branscome, RTI; Bruce Steiner, Collier Shannon; Rich Zavoda, International Steel Group; Mike Long, International Steel Group; Tom Shepker, WCI Steel; Matthew Scherschel, Ispat Intland et al.","date":"2005-09-13"},{"doc_id":159894,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Email to Marvin Branscome, USEPA/RTI from Jim R. Carson re: VEE monthly summaries","date":"2005-09-13"},{"doc_id":159895,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Attendance List for October 22, 2003 Meeting of USEPA and Steel Industry Litigants.","date":"2005-09-13"},{"doc_id":159896,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Email to Marvin Branscome, RTI International from Jim Carson re: Sinter Plant","date":"2005-09-13"},{"doc_id":159897,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Letter to Steve Fruh, USEPA, Office of Air Quality Planning and Standards/Emission Standards Division from Bruce A. Steiner, Collier Shannon Scott PLLC re: Iron & Steel MACT (Maximum Achievable Control Technology) rule","date":"2005-09-13"},{"doc_id":159898,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Email to Steve Fruh, USEPA and Phil Mulrine, USEPA from Bruce Steiner, Collier, Shannon, Scott, PLLC re: proposed Iron and Steel MACT (Maximum Achievable Control Technology) Revisions","date":"2005-09-13"},{"doc_id":159899,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Memorandum to USEPA/Docket OAR from USEPA/OAQPS/ESD re: Estimate of Savings in Monitoring Costs","date":"2005-09-13"},{"doc_id":159901,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Letter to Steve Fruh, USEPA from Rich Zavoda, ISG Cleveland Inc., re: Iron and Steel MACT (Maximum Achievable Control Technology)/NESHAP (National Emissions Standards for Hazardous Air Pollutants) Discussions","date":"2005-09-13"},{"doc_id":159902,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Memorandum to USEPA/Docket OAR from USEPA/OAQPS/ESD re: Opacity Limit for Sinter Coolers","date":"2005-09-13"},{"doc_id":159879,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Mittal Steel Call Summary","date":"2006-07-12"},{"doc_id":17791,"source":"fr_rule","org":"ENVIRONMENTAL PROTECTION AGENCY","doc_type":"Rule","title":"National Emission Standards for Hazardous Air Pollutants for Integrated Iron and Steel Manufacturing Facilities","date":"2006-07-13"},{"doc_id":156833,"source":"docket_item","org":"EPA","doc_type":"other","title":"Docket Index Certification","date":"2009-09-21"},{"doc_id":159855,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Pew Response Letter","date":"2009-09-21"},{"doc_id":156832,"source":"docket_item","org":"EPA","doc_type":"other","title":"Supplemental Petition for Reconsideration","date":"2009-09-23"},{"doc_id":129395,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Document submitted to initiate E.O. 12866 and 13563 review - II&S NPRM","date":"2019-08-16"},{"doc_id":129396,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Part of E.O. 12866 and 13563 Review: Transmittal of II&S RTR briefing materials and industry schematics - II&S NPRM 2060-AT03 06/13/2019","date":"2019-08-16"},{"doc_id":129397,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Part of E.O. 12866 and 13563 Review: Memorandum of 06/18/2019 Conference call between EPA and OMB - II&S NPRM (2060-AT03)","date":"2019-08-16"},{"doc_id":129398,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Part of E.O. 12866 and 13563 Review: Interagency Comments on the II&S NPRM (2060-AT03) (07/08/2019)","date":"2019-08-16"},{"doc_id":129399,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Part of E.O. 12866 and 13563 Review: EPA Response to Interagency request for supporting technical documents and EPA questions on the II&S NPRM (2060-AT03) (07/09/2019)","date":"2019-08-16"},{"doc_id":129400,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Part of E.O. 12866 and 13563 Review Interagency responses to EPA questions on the II&S NPRM (2060-AT03) (07/09/2019)","date":"2019-08-16"},{"doc_id":129401,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Part of E.O. 12866 and 13563 Review: Memorandum of 07/10/2019 Conference call between EPA, OMB, and AISI - II&S NPRM (2060-AT03)","date":"2019-08-16"},{"doc_id":129402,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Part of E.O. 12866 and 13563 Review: Transmittal of attendee list for 07/10/2019 Conference call between EPA and OMB - II&S NPRM (2060-AT03) (07/11/2019)","date":"2019-08-16"},{"doc_id":129403,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Part of E.O. 12866 and 13563 Review: EPA Response to Interagency Comments on the II&S NPRM (2060-AT03) (07/15/2019)","date":"2019-08-16"},{"doc_id":129404,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Part of E.O. 12866 and 13563 Review Transmittal of redline and clean versions of the revised proposal package  II&S NPRM (2060-AT03) (07/19/2019 12:24PM)","date":"2019-08-16"},{"doc_id":129405,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Part of E.O. 12866 and 13563 Review: Transmittal of Text Revisions to the Revised Proposal Package - II&S NPRM (2060-AT03) (07/19/2019 12:38PM)","date":"2019-08-16"},{"doc_id":129406,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Part of E.O. 12866 and 13563 Review: Response to OMB Text Revisions to the Revised Proposal Package - II&S NPRM (2060-AT03) (07/19/2019 12:49PM)","date":"2019-08-16"},{"doc_id":129407,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Part of E.O. 12866 and 13563 Review: Transmittal of Redline and Clean Versions of the Revised Proposal Package - II&S NPRM (2060-AT03) (07/19/2019 1:16PM)","date":"2019-08-16"},{"doc_id":129408,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Part of E.O. 12866 and 13563 Review: Confirmation of Revisions to Proposal Package Under E.O. 12866 and 13563 Review - II&S NPRM (2060-AT03) (07/19/2019 2:21PM)","date":"2019-08-16"},{"doc_id":129409,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Part of E.O. 12866 and 13563 Review: Confirmation of OMB Conclusion to E.O. 12866 and 13563 Review - II&S NPRM (2060-AT03) (07/19/2019 5:55PM)","date":"2019-08-16"},{"doc_id":129410,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Documentation of Changes Made During OMB Review Under E.O. 12866 and 13563  through July 19, 2019 - II&S NPRM","date":"2019-08-16"},{"doc_id":129411,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Document Submitted to Conclude E.O. 12866 and 13563 Review - II&S NPRM","date":"2019-08-16"},{"doc_id":129412,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"40 CFR Part 63, Subpart FFFFF: Redline Comparison of Current Regulatory Text and Proposed Amendments","date":"2019-08-16"},{"doc_id":145517,"source":"docket_item","org":"EPA","doc_type":"data","title":"Section 114 II&S FAQ (12/02/2011)","date":"2019-08-16"},{"doc_id":145518,"source":"docket_item","org":"EPA","doc_type":"report","title":"AK Steel, Ashland, KY (AKS-Ashland-KY) Ladle Refiner Stack Test 10/13-18/2006","date":"2019-08-16"},{"doc_id":145520,"source":"docket_item","org":"EPA","doc_type":"report","title":"AK Steel, Ashland, KY (AKS-Ashland-KY) BOF Vessel No. 1 Scrubber Stack Test 06/13-14/2012","date":"2019-08-16"},{"doc_id":145521,"source":"docket_item","org":"EPA","doc_type":"report","title":"AK Steel, Middletown, OH (AKS-Middletown-OH) BOF Vessel 16 Scrubber Stack Test 12/8-9/2009","date":"2019-08-16"},{"doc_id":145522,"source":"docket_item","org":"EPA","doc_type":"report","title":"AK Steel, Middletown, OH (AKS-Middletown-OH) No. 3 Blast Furnace Stove Stack Test 02/6-7/2012","date":"2019-08-16"},{"doc_id":145523,"source":"docket_item","org":"EPA","doc_type":"report","title":"ArcelorMittal, Cleveland, OH (AM-Cleveland-OH) Summary of Previous Performance Test Results","date":"2019-08-16"},{"doc_id":145525,"source":"docket_item","org":"EPA","doc_type":"report","title":"ArcelorMittal, Cleveland, OH (AM-Cleveland-OH) No. 2 Vessel SC Venturi Scrubber SS&M Plan, October 16, 2006","date":"2019-08-16"},{"doc_id":145527,"source":"docket_item","org":"EPA","doc_type":"report","title":"ArcelorMittal, Burns Harbor, IN (AM-BurnsHarbor-IN) BF C Opacity Observations 03/17-04/02/2009","date":"2019-08-16"},{"doc_id":145528,"source":"docket_item","org":"EPA","doc_type":"report","title":"ArcelorMittal, Burns Harbor, IN (AM-BurnsHarbor-IN) BOF No. 1 & 2 Vessels Scrubbers No. 2 & 4 Stack Test 11/16/2007","date":"2019-08-16"},{"doc_id":145529,"source":"docket_item","org":"EPA","doc_type":"report","title":"ArcelorMittal, Cleveland, OH (AM-Cleveland-OH) Ladle Metallurgy Facility No. 1 Stack Test 03/21-22/2012","date":"2019-08-16"},{"doc_id":145530,"source":"docket_item","org":"EPA","doc_type":"report","title":"ArcelorMittal, Indiana Harbor East, IN (AM-IndianaHarbor-E) Summary of Previous Performance Tests for No. 5 & No. 6 BF","date":"2019-08-16"},{"doc_id":145532,"source":"docket_item","org":"EPA","doc_type":"report","title":"ArcelorMittal, Indiana Harbor East, IN (AM-IndianaHarbor-E) IH7 East Cathouse BH Previous Test Tables","date":"2019-08-16"},{"doc_id":145533,"source":"docket_item","org":"EPA","doc_type":"report","title":"ArcelorMittal, Indiana Harbor East, IN (AM-IndianaHarbor-E) No. 2SP LMF BH Previous Test Tables","date":"2019-08-16"},{"doc_id":145534,"source":"docket_item","org":"EPA","doc_type":"report","title":"ArcelorMittal, Indiana Harbor East, IN (AM-IndianaHarbor-E) No. 3 Sinter Plant DE BH Stack Test 03/7-8/2011","date":"2019-08-16"},{"doc_id":145535,"source":"docket_item","org":"EPA","doc_type":"report","title":"ArcelorMittal, Indiana Harbor East, IN (AM-IndianaHarbor-E) No. 4 Steel Producing Stack Test & Opacity Observation 04/11-13/2006","date":"2019-08-16"},{"doc_id":145536,"source":"docket_item","org":"EPA","doc_type":"report","title":"ArcelorMittal, Indiana Harbor East, IN (AM-IndianaHarbor-E) IH7 West Cathouse BH Stack Test 02/28-3/5/2012","date":"2019-08-16"}],"references":[{"citation_id":1299744,"raw_reference":"OAQPS Control Cost Manual (Fourth Edition), EPA, Office of Air Quality Planning and Standards, Emissions Standards Division, January 1990 (EPA 450/3-90-006 [NTIS/PB90-169954]).","cited_authors":null,"cited_year":null,"cited_title":"OAQPS Control Cost Manual (Fourth Edition), EPA, Office of Air Quality Planning and Standards, Emissions Standards Division, January 1990 (EPA 450/3-90-006 [NTIS/PB90-169954])","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299745,"raw_reference":"DeWolf, Glenn, et al. (Radian, Inc.), The Cost Digest: Cost Summaries of Selected Environmental Control Technologies, EPA, ORD, Office of Environmental Engineering and Technology, October 1984 (EPA-600/884-010).","cited_authors":null,"cited_year":null,"cited_title":"DeWolf, Glenn, et al","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299746,"raw_reference":"Laboratory, June 1979 (EPA-600/8-79-018a). Handbook: Control Technologies for Hazardous Air Pollutants, EPA, Office of Research and Development, Air and Energy Engineering Research Laboratory, June 1991 (EPA-625/6-91-014).","cited_authors":null,"cited_year":null,"cited_title":"Laboratory, June 1979 (EPA-600/8-79-018a)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299747,"raw_reference":"Perry, Robert H., and Chilton, Cecil H., Perry’s Chemical Engineers’ Handbook (Fifth Edition), McGraw-Hill, New York, 1973, pp. 25-12 to 25-16.","cited_authors":"Perry, Robert H., and Chilton, Cecil H., Perry’s Chemical Engineers’ Handbook (Fifth Edition), McGraw-Hill, New York","cited_year":"1973","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299748,"raw_reference":"Humphries, K. K. and Katell, S., Basic Cost Engineering, Marcel Dekker, New York, 1981, pp. 17-33.","cited_authors":"Humphries, K. K. and Katell, S., Basic Cost Engineering, Marcel Dekker, New York","cited_year":"1981","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299749,"raw_reference":"Grant, E.L., Ireson, W.G., and Leavenworth, R.S., Principles of Engineering Economy, Sixth Edition, John Wiley & Sons, New York, 1976.","cited_authors":"Grant, E.L., Ireson, W.G., and Leavenworth, R.S., Principles of Engineering Economy, Sixth Edition, John Wiley & Sons, New York","cited_year":"1976","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299750,"raw_reference":"CEIS (OAQPS) Cost Guidance Memo #2: “Implementing OMB Circular A-94: Guidelines and Discount Rates for Benefit Cost Analysis of Federal Programs,” March 18, 1993.","cited_authors":"CEIS (OAQPS) Cost Guidance Memo #2: “Implementing OMB Circular A-94: Guidelines and Discount Rates for Benefit Cost Analysis of Federal Programs,” March 18","cited_year":"1993","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299751,"raw_reference":"Scheraga, Joel D., Draft of “Supplemental Guidelines on Discounting in the Preparation of Regulatory Impact Analyses”, Office of Policy, Planning and Evaluation, U.S. EPA, March 31, 1989.","cited_authors":"Scheraga, Joel D., Draft of “Supplemental Guidelines on Discounting in the Preparation of Regulatory Impact Analyses”, Office of Policy, Planning and Evaluation, U.S. EPA, March 31","cited_year":"1989","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299752,"raw_reference":"Vatavuk, W.M. and Neveril, R.B., “Estimating Costs of Air-Pollution Control Systems— Part I: Parameters for Sizing Systems,” Chemical Engineering, October 6, 1980, pp. 165168. Pollution Equipment News 1996 Buyer’s Guide, Rimbach Publishing, Pittsburgh, 1996. Internal Revenue Service, Form 1040, 1985.","cited_authors":"Vatavuk, W.M. and Neveril, R.B., “Estimating Costs of Air-Pollution Control Systems— Part I: Parameters for Sizing Systems,” Chemical Engineering, October 6","cited_year":"1980","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299753,"raw_reference":"Shattuck, D.M., et al., Retrofit FGD Cost-Estimating Guidelines. Electric Power Research Institute, Palo Alto, CA (CS-3696, Research Project 1610-1), October 1984.","cited_authors":"Shattuck, D.M., et al., Retrofit FGD Cost-Estimating Guidelines. Electric Power Research Institute, Palo Alto, CA (CS-3696, Research Project 1610-1), October","cited_year":"1984","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299754,"raw_reference":"[10] Kaplan, N., et al., “Retrofit Costs of SO2 and NOx Control at 200 U.S. Coal-Fired Power Plants,” Pittsburgh Coal Conference, 1990.","cited_authors":"[10] Kaplan, N., et al., “Retrofit Costs of SO2 and NOx Control at 200 U.S. Coal-Fired Power Plants,” Pittsburgh Coal Conference","cited_year":"1990","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299755,"raw_reference":"[11] Peters, M.S. and Timmerhaus, K.D., Plant Design and Economics for Chemical Engineers (Third Edition), McGraw-Hill, New York, 1980.","cited_authors":"[11] Peters, M.S. and Timmerhaus, K.D., Plant Design and Economics for Chemical Engineers (Third Edition), McGraw-Hill, New York","cited_year":"1980","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299756,"raw_reference":"[12] Vatavuk, W.M. and Neveril, R.B., “Estimating Costs of Air Pollution Control Systems— Part II: Factors for Estimating Capital and Operating Costs,” Chemical Engineering, November 3, 1980, pp. 157-162. 2-38","cited_authors":"[12] Vatavuk, W.M. and Neveril, R.B., “Estimating Costs of Air Pollution Control Systems— Part II: Factors for Estimating Capital and Operating Costs,” Chemical Engineering, November 3","cited_year":"1980","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299757,"raw_reference":"[13] Vatavuk, W.M. and Neveril, R.B., “Estimating Costs of Air-Pollution Control Systems— Part XVII: Particle Emissions Control,” Chemical Engineering, April 2, 1984, pp. 97-99.","cited_authors":"[13] Vatavuk, W.M. and Neveril, R.B., “Estimating Costs of Air-Pollution Control Systems— Part XVII: Particle Emissions Control,” Chemical Engineering, April 2","cited_year":"1984","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299758,"raw_reference":"[14] The RCRA Risk-Cost Analysis Model, U.S. Environmental Protection Agency, Office of Solid Waste, January 13, 1984. 2-39","cited_authors":"[14] The RCRA Risk-Cost Analysis Model, U.S. Environmental Protection Agency, Office of Solid Waste, January 13","cited_year":"1984","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299759,"raw_reference":"Management Association. 1992, pp. 155-205.","cited_authors":"Management Association","cited_year":"1992","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299760,"raw_reference":"Burton, D. Jeff. Industrial Ventilation Work Book. Salt Lake City: DJBA, Inc. 1989. The Measurement Solution: Using a Temporary Total Enclosure for Capture Efficiency Testing. Research Triangle Park, NC: U.S. Environmental Protection Agency. August 1991 (EPA-450/4-91-020), pp. 3,11. The Measurement Solution, pp. 11-29.","cited_authors":"Burton, D. Jeff. Industrial Ventilation Work Book. Salt Lake City: DJBA, Inc","cited_year":"1989","cited_title":"The Measurement Solution: Using a Temporary Total Enclosure for Capture Efficiency Testing","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299761,"raw_reference":"NY: John Wiley & Sons, Inc. 1991. Telephone conversation between William M. Vatavuk, U.S. Environmental Protection Agency (Research Triangle Park, NC) and Todd N. Stine, United McGill Company (Raleigh, NC), May 24, 1993. Thermoplastic Duct (PVC) Construction Manual, 2nd Edition 1994. Vienna, VA: Sheet Metal and Air Conditioning Contractors’ National Association, Inc. (SMACNA). May 1987, pp. 61-85. Thermoplastic Duct Construction Manual, p. 64.","cited_authors":"NY: John Wiley & Sons, Inc","cited_year":"1991","cited_title":"Telephone conversation between William M. Vatavuk, U.S. Environmental Protection Agency (Research Triangle Park, NC) and Todd N. Stine, United McGill Company (Raleigh, NC), May 24, 1993","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299762,"raw_reference":"[10] Dust Control System Accessories Price List. Huntington Park, CA: Murphy-Rodgers, Inc. July 1992.","cited_authors":"[10] Dust Control System Accessories Price List. Huntington Park, CA: Murphy-Rodgers, Inc. July","cited_year":"1992","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299763,"raw_reference":"[12] Letters from Samir Karandikar, EPCON Industrial Systems (Woodlands, TX) to William M. Vatavuk, U.S. Environmental Protection Agency (Research Triangle Park, NC). May 21 and June 9, 1993.","cited_authors":"[12] Letters from Samir Karandikar, EPCON Industrial Systems (Woodlands, TX) to William M. Vatavuk, U.S. Environmental Protection Agency (Research Triangle Park, NC). May 21 and June 9","cited_year":"1993","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299764,"raw_reference":"OH: United McGill Corporation. 1990. 1-54","cited_authors":"OH: United McGill Corporation","cited_year":"1990","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299765,"raw_reference":"Groveport, OH: United McGill Corporation. 1990. [15]","cited_authors":"Groveport, OH: United McGill Corporation","cited_year":"1990","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299766,"raw_reference":"HVAC Duct Construction Standards: Metal and Flexible. Vienna, VA: Sheet Metal and Air Conditioning Contractors’ National Association, Inc. (SMACNA). 1985, pp. 2-15 to 2-17. [16]","cited_authors":"HVAC Duct Construction Standards: Metal and Flexible. Vienna, VA: Sheet Metal and Air Conditioning Contractors’ National Association, Inc. (SMACNA)","cited_year":"1985","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299767,"raw_reference":"Handbook, Sixth Edition. New York, NY: McGraw-Hill, Inc. 1984.","cited_authors":"Handbook, Sixth Edition. New York, NY: McGraw-Hill, Inc","cited_year":"1984","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299768,"raw_reference":"[17] Product catalog. Rio, WI: Gaskets, Inc. 1994. [18]","cited_authors":"[17] Product catalog. Rio, WI: Gaskets, Inc","cited_year":"1994","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299769,"raw_reference":"[21] Guide for Steel Stack Design and Construction. Vienna, VA: Sheet Metal and Air Conditioning Contractors’ National Association, Inc. (SMACNA). 1983. [22]","cited_authors":"[21] Guide for Steel Stack Design and Construction. Vienna, VA: Sheet Metal and Air Conditioning Contractors’ National Association, Inc. (SMACNA)","cited_year":"1983","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299770,"raw_reference":"Engineers, Third Edition. New York: McGraw-Hill, Inc., 1980, pp. 508-510. [25]","cited_authors":"Engineers, Third Edition. New York: McGraw-Hill, Inc","cited_year":"1980","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299771,"raw_reference":"Engineering, December 1, 1980, pp. 111 to 115.","cited_authors":"Engineering, December 1","cited_year":"1980","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299772,"raw_reference":"[34] Telephone conversation between William M. Vatavuk, U.S. Environmental Protection Agency (Research Triangle Park, NC) and Dennis Woll, Air Plastics, Inc. (OH), August 10, 1993.","cited_authors":"[34] Telephone conversation between William M. Vatavuk, U.S. Environmental Protection Agency (Research Triangle Park, NC) and Dennis Woll, Air Plastics, Inc. (OH), August 10","cited_year":"1993","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299773,"raw_reference":"[35] Telephone conversation between William M. Vatavuk, U.S. Environmental Protection Agency (Research Triangle Park, NC) and Pat Caputo, Intellect Systems & Marketing, Inc. (Bohemia, NY), October 22, 1993. [36]","cited_authors":"[35] Telephone conversation between William M. Vatavuk, U.S. Environmental Protection Agency (Research Triangle Park, NC) and Pat Caputo, Intellect Systems & Marketing, Inc. (Bohemia, NY), October 22","cited_year":"1993","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299774,"raw_reference":"Vatavuk, U.S. Environmental Protection Agency (Research Triangle Park, NC). June 10, 1993. [38]","cited_authors":"Vatavuk, U.S. Environmental Protection Agency (Research Triangle Park, NC). June 10","cited_year":"1993","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299775,"raw_reference":"Green, Don W. and Maloney, James O. Perry’s Chemical Engineers’ Handbook, Sixth Edition. New York, NY: McGraw-Hill, Inc. 1984. [39]","cited_authors":"Green, Don W. and Maloney, James O. Perry’s Chemical Engineers’ Handbook, Sixth Edition. New York, NY: McGraw-Hill, Inc","cited_year":"1984","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299776,"raw_reference":"Engineers, Fourth Edition. New York, NY: McGraw-Hill, Inc. 1991.","cited_authors":"Engineers, Fourth Edition. New York, NY: McGraw-Hill, Inc","cited_year":"1991","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299777,"raw_reference":"[40] Engineering Design Reference Manual for Supply Air Handling Systems. Groveport, OH: United McGill Corporation. 1992, pp. 34.","cited_authors":"[40] Engineering Design Reference Manual for Supply Air Handling Systems. Groveport, OH: United McGill Corporation","cited_year":"1992","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299778,"raw_reference":"[49] Carlton-Jones, Dennis and Schneider, H.B., “Tall Chimneys,” Chemical Engineering, October 14, 1968, p. 167.","cited_authors":"[49] Carlton-Jones, Dennis and Schneider, H.B., “Tall Chimneys,” Chemical Engineering, October 14","cited_year":"1968","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299779,"raw_reference":"[50] Guideline for Determination of Good Engineering Practice: Stack Height (Technical Support Document for Stack Height Regulations) (Revised). Research Triangle Park, NC: U.S. Environmental Protection Agency. June 1985 (NTIS PB-85-225241), p.1.","cited_authors":null,"cited_year":null,"cited_title":"[50] Guideline for Determination of Good Engineering Practice: Stack Height (Technical Support Document for Stack Height Regulations) (Revised)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299780,"raw_reference":"[55] Hood cost data request responses from four hood vendors to William M. Vatavuk, U.S. Environmental Protection Agency (Research Triangle Park, NC). June-July 1993.","cited_authors":"[55] Hood cost data request responses from four hood vendors to William M. Vatavuk, U.S. Environmental Protection Agency (Research Triangle Park, NC). June-July","cited_year":"1993","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299781,"raw_reference":"[56] Ductwork cost data request responses from six vendors to William M. Vatavuk, U.S. Environmental Protection Agency (Research Triangle Park, NC). May-July 1993.","cited_authors":"[56] Ductwork cost data request responses from six vendors to William M. Vatavuk, U.S. Environmental Protection Agency (Research Triangle Park, NC). May-July","cited_year":"1993","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299782,"raw_reference":"[57] Stack cost data request responses from four vendors to William M. Vatavuk, U.S. Environmental Protection Agency (Research Triangle Park, NC). May-July 1993.","cited_authors":"[57] Stack cost data request responses from four vendors to William M. Vatavuk, U.S. Environmental Protection Agency (Research Triangle Park, NC). May-July","cited_year":"1993","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299783,"raw_reference":"[58] Op. cit., Stine-Vatavuk letter, June 10, 1993.","cited_authors":"[58] Op. cit., Stine-Vatavuk letter, June 10","cited_year":"1993","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299784,"raw_reference":"[61] Telephone conversation between William M. Vatavuk, U.S. Environmental Protection Agency (Research Triangle Park, NC) and Todd N. Stine, United McGill Company (Raleigh, NC), December 10, 1993. [62]","cited_authors":"[61] Telephone conversation between William M. Vatavuk, U.S. Environmental Protection Agency (Research Triangle Park, NC) and Todd N. Stine, United McGill Company (Raleigh, NC), December 10","cited_year":"1993","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299785,"raw_reference":"Darman, Richard. Guidelines and Discount Rates for Benefit-Cost Analysis of Federal Programs (OMB Circular No. A-94 Revised). Washington, DC: Office of Management and Budget. October 29, 1992. 1-57","cited_authors":"Darman, Richard. Guidelines and Discount Rates for Benefit-Cost Analysis of Federal Programs (OMB Circular No. A-94 Revised). Washington, DC: Office of Management and Budget. October 29","cited_year":"1992","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299786,"raw_reference":"Lukey, Michael E. “Total Permanent Enclosures for the Surface Coating Industry,” Air and Waste Management Association Specialty Meeting, Paper No. 92-51-07, May 1, 1992.","cited_authors":"Lukey, Michael E. “Total Permanent Enclosures for the Surface Coating Industry,” Air and Waste Management Association Specialty Meeting, Paper No. 92-51-07, May 1","cited_year":"1992","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299787,"raw_reference":"Lukey, Michael E. “Designing Effective and Safe Total Permanent Enclosures,” Air and Waste Management Association Specialty Meeting, Paper No. A1098, February 15, 1993. 3-34 29 CFR Part 1910 Subpart Z [10]","cited_authors":"Lukey, Michael E. “Designing Effective and Safe Total Permanent Enclosures,” Air and Waste Management Association Specialty Meeting, Paper No. A1098, February 15","cited_year":"1993","cited_title":"3-34 29 CFR Part 1910 Subpart Z [10]","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299788,"raw_reference":"Control, February 26-28, 1997, San Diego, CA. [11]","cited_authors":"Control, February 26-28","cited_year":"1997","cited_title":"San Diego, CA. [11]","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299789,"raw_reference":"ASHRAE. 1992. 1992 ASHRAE Handbook HVAC Systems and Equipment. Atlanta,","cited_authors":"ASHRAE","cited_year":"1992","cited_title":"1992 ASHRAE Handbook HVAC Systems and Equipment","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299790,"raw_reference":"Douglas A. Toothman, Pacific Environmental Services, Inc. (Herndon, VA). November 18, 1997 and December 24, 1997. [13]","cited_authors":"Douglas A. Toothman, Pacific Environmental Services, Inc. (Herndon, VA). November 18, 1997 and December 24","cited_year":"1997","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299791,"raw_reference":"Means, R.S. Facilities Construction Cost Data (Kingston, MA), 1997.","cited_authors":"Means, R.S. Facilities Construction Cost Data (Kingston, MA)","cited_year":"1997","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299792,"raw_reference":"[14] Price and Data Catalog: Room Pressure Monitor. Modus Instruments, Inc. 1994 and telephone conversation between Modus Instruments, Inc. (Northboro, MA) and Chandrika Prasad, Pacific Environmental Services, Inc. (Herndon, VA). December 29, 1997.","cited_authors":"[14] Price and Data Catalog: Room Pressure Monitor. Modus Instruments, Inc. 1994 and telephone conversation between Modus Instruments, Inc. (Northboro, MA) and Chandrika Prasad, Pacific Environmental Services, Inc. (Herndon, VA). December 29","cited_year":"1997","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299793,"raw_reference":"[16] Letters and data from Stephen R. Ferree, Sierra Monitor Corporation (Milpitas, CA) to Chandrika Prasad, Pacific Environmental Services, Inc. (Herndon, VA). September 23, 1997 and December 30, 1997.","cited_authors":"[16] Letters and data from Stephen R. Ferree, Sierra Monitor Corporation (Milpitas, CA) to Chandrika Prasad, Pacific Environmental Services, Inc. (Herndon, VA). September 23, 1997 and December 30","cited_year":"1997","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299794,"raw_reference":"MD) and Chandrika Prasad, Pacific Environmental Services, Inc. (Herndon, VA). June 12, 1998.","cited_authors":"MD) and Chandrika Prasad, Pacific Environmental Services, Inc. (Herndon, VA). June 12","cited_year":"1998","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299795,"raw_reference":"[18] Read Plastics, Rockville, MD, September 8, 1998.","cited_authors":"[18] Read Plastics, Rockville, MD, September 8","cited_year":"1998","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299796,"raw_reference":"[19] Telecommunication between Austin Chadwick of E. and K. Controls (Leesburg, VA) and Chandrika Prasad, Pacific Environmental Services, Inc. (Herndon, VA). June 12, 1998. 3-35","cited_authors":"[19] Telecommunication between Austin Chadwick of E. and K. Controls (Leesburg, VA) and Chandrika Prasad, Pacific Environmental Services, Inc. (Herndon, VA). June 12","cited_year":"1998","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299797,"raw_reference":"Champaign, IL 61821 Walter Koucky and Paula M. Hemmer E. H. Pechan & Associates, Inc. 3622 Lyckan Parkway, Suite 2002","cited_authors":null,"cited_year":null,"cited_title":"Champaign, IL 61821 Walter Koucky and Paula M. Hemmer E. H. Pechan & Associates, Inc","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299798,"raw_reference":"[11] Periodic Monitoring Technical Reference Document, April 1999, p 5-26.","cited_authors":"[11] Periodic Monitoring Technical Reference Document, April","cited_year":"1999","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299799,"raw_reference":"[12] Periodic Monitoring Technical Reference Document, April 1999, p 5-23.","cited_authors":"[12] Periodic Monitoring Technical Reference Document, April","cited_year":"1999","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299800,"raw_reference":"[13] Periodic Monitoring Technical Reference Document, April 1999, p 5-11.","cited_authors":"[13] Periodic Monitoring Technical Reference Document, April","cited_year":"1999","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299801,"raw_reference":"[16] Technical Support Document for the Regulatory Impact Analysis of the Enhanced Monitoring Rule. Mathtech, Inc. September 30,1993, p 2-21, 2-22.","cited_authors":"[16] Technical Support Document for the Regulatory Impact Analysis of the Enhanced Monitoring Rule. Mathtech, Inc. September 30","cited_year":"1993","cited_title":"p 2-21, 2-22","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299802,"raw_reference":"Technology, John Wiley & Sons, New York, 1984, pp. 135-192. Handbook of Chemistry and Physics, 54th Edition, The Chemical Rubber Company,","cited_authors":"Technology, John Wiley & Sons, New York","cited_year":"1984","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299803,"raw_reference":"Cleveland, 1973-74, pp. D85-D92. Correspondence: Wayne G. Schulinger and Georgiana Riley (TIGG Corporation,","cited_authors":"Cleveland","cited_year":"1973-74","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299804,"raw_reference":"Pittsburgh, 1986. Adsorption Handbook, Calgon Corporation, Pittsburgh, 1980.","cited_authors":"Pittsburgh","cited_year":"1986","cited_title":"Adsorption Handbook, Calgon Corporation, Pittsburgh, 1980","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299805,"raw_reference":"Rogers, Tony, “Comparison of BED SIZE and Calgon Adsorption Isotherms”, Research Triangle Institute (Research Triangle Park, NC), January 20, 1988. Correspondence: Richard Selznick (Baron Blakeslee, Inc., Westfield. NJ) to William M. Vatavuk (U.S. EPA, OAQPS, Research Triangle Park, NC), April 23, 1986.","cited_authors":"Rogers, Tony, “Comparison of BED SIZE and Calgon Adsorption Isotherms”, Research Triangle Institute (Research Triangle Park, NC), January 20","cited_year":"1988","cited_title":"Correspondence: Richard Selznick (Baron Blakeslee, Inc., Westfield","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299806,"raw_reference":"[10] Correspondence: Denny Clodfelter(M&W Industries, Inc., Rural Hall, NC) to William M. Vatavuk (U.S. EPA, OAQPS, Research Triangle Park, NC), September 25, 1989. [11]","cited_authors":"[10] Correspondence: Denny Clodfelter(M&W Industries, Inc., Rural Hall, NC) to William M. Vatavuk (U.S. EPA, OAQPS, Research Triangle Park, NC), September 25","cited_year":"1989","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299807,"raw_reference":"Park, NC) with William M. Vatavuk (U.S. EPA, OAQPS, Research Triangle Park, NC), September 11, 1986.","cited_authors":"Park, NC) with William M. Vatavuk (U.S. EPA, OAQPS, Research Triangle Park, NC), September 11","cited_year":"1986","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299808,"raw_reference":"EPA, OAQPS, Research Triangle Park, NC), July 25, 1986.","cited_authors":"EPA, OAQPS, Research Triangle Park, NC), July 25","cited_year":"1986","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299809,"raw_reference":"[16] Chemical Marketing Reporter, December 2, 1989. 1-39","cited_authors":"[16] Chemical Marketing Reporter, December 2","cited_year":"1989","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299810,"raw_reference":"Erikson, D.G., Organic Chemical Manufacturing Volume 5: Adsorption, Condensat ion, and Absorption Devices, U.S. Environmental Protection Agency. Research Triangle Park, North Carolina, Publication No. EPA 450/380-027, December 1980.","cited_authors":"Erikson, D.G., Organic Chemical Manufacturing Volume 5: Adsorption, Condensat ion, and Absorption Devices, U.S. Environmental Protection Agency. Research Triangle Park, North Carolina, Publication No. EPA 450/380-027, December","cited_year":"1980","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299811,"raw_reference":"Vatavuk, W.M., and R.B. Neveril, “Estimating Costs of Air Pollution Control Sys tems: Part XV1. Costs of Refrigeration Systems”, Chemical Engineering, May 16, 1983, pp. 95-98.","cited_authors":"Vatavuk, W.M., and R.B. Neveril, “Estimating Costs of Air Pollution Control Sys tems: Part XV1. Costs of Refrigeration Systems”, Chemical Engineering, May 16","cited_year":"1983","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299812,"raw_reference":"McCabe, W.L., and J.C. Smith, Unit Operations of Chemical Engineering (Third Edition), McGraw-Hill Book Company, New York, 1976.","cited_authors":"McCabe, W.L., and J.C. Smith, Unit Operations of Chemical Engineering (Third Edition), McGraw-Hill Book Company, New York","cited_year":"1976","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299813,"raw_reference":"Perry, R.H. and C.H. Chilton, Eds. Chemical Engineers’ Handbook (Sixth Edition), McGraw-Hill Book Company, New York, 1989.","cited_authors":"Perry, R.H. and C.H. Chilton, Eds. Chemical Engineers’ Handbook (Sixth Edition), McGraw-Hill Book Company, New York","cited_year":"1989","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299814,"raw_reference":"Kern, D.Q., Process Heat Transfer, McGraw-Hill Book Company, New York, 1950","cited_authors":null,"cited_year":null,"cited_title":"Kern, D.Q., Process Heat Transfer, McGraw-Hill Book Company, New York, 1950","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299815,"raw_reference":"Smith, J.M., and M.C. VanNess, Introduction to Chemical Engineering Thermody namics (Third Edition), McGraw-Hill Book Company, New York, 1975.","cited_authors":"Smith, J.M., and M.C. VanNess, Introduction to Chemical Engineering Thermody namics (Third Edition), McGraw-Hill Book Company, New York","cited_year":"1975","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299816,"raw_reference":"Reid, Robert C., John M. Prausnitz, and Bruce E. Poling, Properties of Gases & Liquids (Fourth Edition), McGraw-Hill Book Company, New York, 1987. Letter and attachment from Robert V. Sisk. Jr. of Piedmont Engineering, Pineville, North Carolina, to Wiley Barbour of Radian Corporation, Research Triangle Park, North Carolina, January 28, 1991. Letter and attachment from Waldrop, R., and V. Sardo of Edwards Engineering 2-36 Corp., Research Pompton Plains, New Jersey, to Wiley Barbour of Radian Corporation, Triangle Park, North Carolina, October 1, 1990. [10]","cited_authors":"Reid, Robert C., John M. Prausnitz, and Bruce E. Poling, Properties of Gases & Liquids (Fourth Edition), McGraw-Hill Book Company, New York","cited_year":"1987","cited_title":"Letter and attachment from Robert V. Sisk","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299817,"raw_reference":"[11] Letter and attachment from Bob Hansek of ITT Corporation, Atlanta, Georgia to Wiley Barbour of Radian Corporation, Research Triangle Park, North Carolina, October 10, 1990.","cited_authors":"[11] Letter and attachment from Bob Hansek of ITT Corporation, Atlanta, Georgia to Wiley Barbour of Radian Corporation, Research Triangle Park, North Carolina, October 10","cited_year":"1990","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299818,"raw_reference":"[12] Letter and attachment from Avery Cooke of Liquid Handling Equipment, Inc., Char lotte, North Carolina to Rich Pelt of Radian Corporation, Research Triangle Park, North Carolina, September 20, 1990.","cited_authors":"[12] Letter and attachment from Avery Cooke of Liquid Handling Equipment, Inc., Char lotte, North Carolina to Rich Pelt of Radian Corporation, Research Triangle Park, North Carolina, September 20","cited_year":"1990","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299819,"raw_reference":"[13] Letter from Richard Waldrop of Edwards Engineering Corp., Pompton Plains, New Jersey to William Vatavuk, P.E., Durham, North Carolina, August 29, 1988. 2-37 Appendix A Properties of Selected Compounds 2-38 Table 2.8: Properties of Selected Compounds Heat Molecular Heat of Capacityc Weight Condensationb (lb/lb-mole) (Btu/lb-mole) (Btu/lbmole °F) Critical Temp.a (ER) Boiling Point (EF) Acetone 58.08 12,510 Acetylene Acrylonitrile Aniline 1259 -119 26.02 53.06 93.13 7,290 14,040 19,160 Benzene Benzonitrile Butane Chloroethane Chloroform Chloromethan Cyclobutane Cyclohexane 1012 1259","cited_authors":"[13] Letter from Richard Waldrop of Edwards Engineering Corp., Pompton Plains, New Jersey to William Vatavuk, P.E., Durham, North Carolina, August 29","cited_year":"1988","cited_title":"2-37 Appendix A Properties of Selected Compounds 2-38 Table 2.8: Properties of Selected Compounds Heat Molecular Heat of Capacityc Weight Condensationb (lb/lb-mole) (Btu/lb-mole) (Btu/lbmole °F) Critical Temp.a (ER) Boiling Point (EF) Acetone 58.08 12,510 Acetylene Acrylonitrile Aniline 1259 -119 26.02 53.06 93.13 7,290 14,040 19,160 Benzene Benzonitrile Butane Chloroethane Chloroform Chloromethan Cyclobutane Cyclohexane 1012 1259","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299820,"raw_reference":"API Recommended Practice 521, Second Edition, September 1982.","cited_authors":"API Recommended Practice 521, Second Edition, September","cited_year":"1982","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299821,"raw_reference":"Kalcevic, V. (IT Enviroscience), “Control Device Evaluation Flares and the Use of Emissions as Fuels”, Organic Chemical Manufacturing Volume 4; Combustion Control Devices, U.S. Environmental Protection Agency, Research Triangle Park, NC, Publication no. EPA-450/3-80-026, December 1980, Report 4. Reactor Processes in Synthetic Organic Chemical Manufacturing Industry-Background Information for Proposed Standards, U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards, Research Triangle Park, NC, Preliminary","cited_authors":"Kalcevic, V. (IT Enviroscience), “Control Device Evaluation Flares and the Use of Emissions as Fuels”, Organic Chemical Manufacturing Volume 4; Combustion Control Devices, U.S. Environmental Protection Agency, Research Triangle Park, NC, Publication no. EPA-450/3-80-026, December","cited_year":"1980","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299822,"raw_reference":"Draft, EPA 450/3-90-016a, June 1990. Letter from J. Keith McCartney (John Zink Co., Tulsa, OK) to William M. Vatavuk (U.S. Environmental Protection Agency, Research Triangle Park, NC), November 19, 1990. Letter from David Shore (Flaregas Corp., Spring Valley, NY) to William M. Vatavuk (U.S. Environmental Protection Agency, Research Triangle Park, NC), October 3, 1990. Letter from Pete Tkatschenko (NAO, Inc., Philadelphia, PA) to Diana Stone (Radian, Research Triangle Park, NC), May 2, 1990. 1-42 Letter to Gary Tyler (Kaldair, Inc., Houston, TX) to Diana Stone (Radian, Research Triangle Park, NC), April 10, 1990. Letter from Zahir Bozai (Peabody Engineering Corp., Stamford, CT) to Diana Stone (Radian, Research Triangle Park, NC), May 7, 1990. Letter from James Parker (John Zink Co., Tulsa, OK) to Diana Stone (Radian, Research Triangle Park, NC), April 17, 1990.","cited_authors":"Draft, EPA 450/3-90-016a, June","cited_year":"1990","cited_title":"Letter from J. Keith McCartney (John Zink Co., Tulsa, OK) to William M. Vatavuk (U.S. Environmental Protection Agency, Research Triangle Park, NC), November 19, 1990","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299823,"raw_reference":"[10] Letter from Nick Sanderson (Flaregas Corp., Spring Valley, NY) to Diana Stone (Radian, Research Triangle Park, NC), May 2, 1990. [11]","cited_authors":"[10] Letter from Nick Sanderson (Flaregas Corp., Spring Valley, NY) to Diana Stone (Radian, Research Triangle Park, NC), May 2","cited_year":"1990","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299824,"raw_reference":"Wu, F.H., “Drum Separator Design, A New Approach,” Chemical Engineering, April 2, 1984, pp. 74-81. [12]","cited_authors":"Wu, F.H., “Drum Separator Design, A New Approach,” Chemical Engineering, April 2","cited_year":"1984","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299825,"raw_reference":"Mulet, A., “Estimate Costs of Pressure Vessels Via Correlations,” Chemical Engineering, October 5, 1981, pp. 145-150.","cited_authors":"Mulet, A., “Estimate Costs of Pressure Vessels Via Correlations,” Chemical Engineering, October 5","cited_year":"1981","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299826,"raw_reference":"[13] Process Plant Construction Estimating Standards, Richardson Engineering Services, Inc., Volume 4, 1988 Edition. [14]","cited_authors":null,"cited_year":null,"cited_title":"[13] Process Plant Construction Estimating Standards, Richardson Engineering Services, Inc., Volume 4, 1988 Edition","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299827,"raw_reference":"Engineers, Third Edition, McGraw-Hill, 1980.","cited_authors":"Engineers, Third Edition, McGraw-Hill","cited_year":"1980","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299828,"raw_reference":"[15] Cost Information from Piedmont HUB, Incorporated, Raleigh, NC. August 1990. [16]","cited_authors":"[15] Cost Information from Piedmont HUB, Incorporated, Raleigh, NC. August","cited_year":"1990","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299829,"raw_reference":"Vatavuk, W.M., and R. Neveril,”Estimating Costs of Air Pollution Control Systems, Part II: Factors for Estimating Capital and Operating Costs,: Chemical Engineering, November 3, 1980, pp. 157-162.","cited_authors":"Vatavuk, W.M., and R. Neveril,”Estimating Costs of Air Pollution Control Systems, Part II: Factors for Estimating Capital and Operating Costs,: Chemical Engineering, November 3","cited_year":"1980","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299830,"raw_reference":"[17] Handbook of Chemistry and Physics, 55th Edition, CRC Press, 1974-1975. [18]","cited_authors":"[17] Handbook of Chemistry and Physics, 55th Edition, CRC Press","cited_year":"1974-1975","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299831,"raw_reference":"Green, G.P. and Epstein, R.K., Employment and Earnings, Department of Labor, Bureau of Labor Statistics, Volume 37, No.4, April 1990.","cited_authors":"Green, G.P. and Epstein, R.K., Employment and Earnings, Department of Labor, Bureau of Labor Statistics, Volume 37, No.4, April","cited_year":"1990","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299832,"raw_reference":"[19] Monthly Energy Review, Energy Information Administration, Office of Energy Markets and End Use, U.S. Department of Energy, DOE-EIA-0035(90/12), February 1990. 1-43","cited_authors":"[19] Monthly Energy Review, Energy Information Administration, Office of Energy Markets and End Use, U.S. Department of Energy, DOE-EIA-0035(90/12), February","cited_year":"1990","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299833,"raw_reference":"Weldon, J. and S. M. Senkan, Combustion Sci. Technol., 1986, 47.","cited_authors":"Weldon, J. and S. M. Senkan, Combustion Sci. Technol","cited_year":"1986","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299834,"raw_reference":"Manning, P., Hazard Waste, 1984, 1(1). Pope, D., Walker, D. S., Moss, R. L., Atmos. Environ., 1976, 10.","cited_authors":"Manning, P., Hazard Waste","cited_year":"1984","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299835,"raw_reference":"Musick, J. K., and F. W. Williams, Ind. Eng. Chem. Prod. Res. Dev., 1974, 13(3). Letter from Robert M. Yarrington (Englehard Corporation, Edison, NJ) to William M. Vatavuk (EPA, OAQPS, Research Triangle Park, NC), August 14, 1989.","cited_authors":"Musick, J. K., and F. W. Williams, Ind. Eng. Chem. Prod. Res. Dev","cited_year":"1974","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299836,"raw_reference":"[10] Personal Communication from Bill Sheffer (ARI, Inc., Palatine, IL) to Donald R. van der Vaart (RTI, Research Triangle Park, NC), March 30, 1988.","cited_authors":"[10] Personal Communication from Bill Sheffer (ARI, Inc., Palatine, IL) to Donald R. van der Vaart (RTI, Research Triangle Park, NC), March 30","cited_year":"1988","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299837,"raw_reference":"[11] Personal Communication from Ralph Stettenbenz (Combustion Engineering, Air Preheater, Inc., Wellsville, NY) to Donald R. van der Vaart (RTI, Research Triangle Park, NC), March 23, 1988. [12]","cited_authors":"[11] Personal Communication from Ralph Stettenbenz (Combustion Engineering, Air Preheater, Inc., Wellsville, NY) to Donald R. van der Vaart (RTI, Research Triangle Park, NC), March 23","cited_year":"1988","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299838,"raw_reference":"[14] Perry, R. H. and C. H. Chilton(eds.), Chemical Engineers Handbook, 5th ed., McGrawHill, New York, NY 1973.","cited_authors":"[14] Perry, R. H. and C. H. Chilton(eds.), Chemical Engineers Handbook, 5th ed., McGrawHill, New York, NY","cited_year":"1973","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299839,"raw_reference":"[15] Personal Communication from Robert Yarrington (Englehard Corp., Edison, NJ) to William M. Vatavuk (EPA, OAQPS, Research Triangle Park, NC), June 6, 1989.","cited_authors":"[15] Personal Communication from Robert Yarrington (Englehard Corp., Edison, NJ) to William M. Vatavuk (EPA, OAQPS, Research Triangle Park, NC), June 6","cited_year":"1989","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299840,"raw_reference":"Janet D. Groeber (SAIC. Cincinnati, OH), September 29,1999.","cited_authors":"Janet D. Groeber (SAIC. Cincinnati, OH), September 29","cited_year":"1999","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299841,"raw_reference":"[17] Personal communication from Gary Raemheld (Goenergy, Kent, WA) to Janet D. Groeber (SAIC. Cincinnati, OH), September 28,1999.","cited_authors":"[17] Personal communication from Gary Raemheld (Goenergy, Kent, WA) to Janet D. Groeber (SAIC. Cincinnati, OH), September 28","cited_year":"1999","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299842,"raw_reference":"[18] Personal communication from John Wilke (CVM Corp., Wilmington, DE) to Janet D. Groeber (SAIC. Cincinnati, OH), September 29,1999.","cited_authors":"[18] Personal communication from John Wilke (CVM Corp., Wilmington, DE) to Janet D. Groeber (SAIC. Cincinnati, OH), September 29","cited_year":"1999","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299843,"raw_reference":"[19] Personal Communication from Thomas Schmidt (ARI International, Palatine, IL) to William M. Vatavuk (EPA, OAQPS, Research Triangle Park, NC), June 7, 1989. [20]","cited_authors":"[19] Personal Communication from Thomas Schmidt (ARI International, Palatine, IL) to William M. Vatavuk (EPA, OAQPS, Research Triangle Park, NC), June 7","cited_year":"1989","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299844,"raw_reference":"IL) to Donald R. van der Vaart (RTI, Research Triangle Park, NC), March 4, 1988.","cited_authors":"IL) to Donald R. van der Vaart (RTI, Research Triangle Park, NC), March 4","cited_year":"1988","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299845,"raw_reference":"Donald R. van der Vaart (RTI, Research Triangle Park, NC), March 28, 1988.","cited_authors":"Donald R. van der Vaart (RTI, Research Triangle Park, NC), March 28","cited_year":"1988","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299846,"raw_reference":"[23] Personal Communication from C. M. Martinson (TEC Systems, DePere, WI) to Donald R. van der Vaart (RTI, Research Triangle Park, NC), March 28, 1988.","cited_authors":"[23] Personal Communication from C. M. Martinson (TEC Systems, DePere, WI) to Donald R. van der Vaart (RTI, Research Triangle Park, NC), March 28","cited_year":"1988","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299847,"raw_reference":"NJ) to Donald R. van der Vaart (RTI, Research Triangle Park, NC), March 16, 1988.","cited_authors":"NJ) to Donald R. van der Vaart (RTI, Research Triangle Park, NC), March 16","cited_year":"1988","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299848,"raw_reference":"Donald R. van der Vaart (RTI, Research Triangle Park, NC), March 20, 1988. [27]","cited_authors":"Donald R. van der Vaart (RTI, Research Triangle Park, NC), March 20","cited_year":"1988","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299849,"raw_reference":"[28] Letter from William M. Vatavuk (EPA, OAQPS, Research Triangle Park, NC) to Gerald Schrubba (Salem Engelhard, South Lyon, MI), September 22, 1992.","cited_authors":"[28] Letter from William M. Vatavuk (EPA, OAQPS, Research Triangle Park, NC) to Gerald Schrubba (Salem Engelhard, South Lyon, MI), September 22","cited_year":"1992","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299850,"raw_reference":"[29] Letter from William M. Vatavuk (EPA, OAQPS, Research Triangle Park, NC) to Rod Pennington (REECO/Research Cottrell, Somerville, NJ), September 22, 1992. 2-51 Appendix A Properties of Selected Compounds 2-52 Table 2.12: Limits of Flammability of Combustible Organic Compounds in Air at Atmospheric Pressure, Room Temperature","cited_authors":"[29] Letter from William M. Vatavuk (EPA, OAQPS, Research Triangle Park, NC) to Rod Pennington (REECO/Research Cottrell, Somerville, NJ), September 22","cited_year":"1992","cited_title":"2-51 Appendix A Properties of Selected Compounds 2-52 Table 2.12: Limits of Flammability of Combustible Organic Compounds in Air at Atmospheric Pressure, Room Temperature","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299851,"raw_reference":"PA. October 1995. Electric Power Research Institute (EPRI). Technical Assessment Guide, Vol. 1. Revision 7, 1993. Northeast States for Coordinated Air Use Management (NESCAUM). Status Report on NOx Control Technologies and Cost Effectiveness for Utility Boilers. June 1998. United States Patent, Method for the Reduction of the Concentration of NO In Combustion Effluents Using Ammonia. Inventor: Richard K. Lyon, Patent Number 3,900,554. August 19, 1975. [10]","cited_authors":"PA. October","cited_year":"1995","cited_title":"Electric Power Research Institute (EPRI)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299852,"raw_reference":"Rini, M.J., J.A. Nicholson, and M.B. Cohen. Evaluating the SNCR Process for Tangentially-Fired Boilers. Presented at the 1993 Joint Symposium on Stationary Combustion NOx Control, Bal Harbor, Florida. May 24 - 27, 1993.","cited_authors":"Rini, M.J., J.A. Nicholson, and M.B. Cohen. Evaluating the SNCR Process for Tangentially-Fired Boilers. Presented at the 1993 Joint Symposium on Stationary Combustion NOx Control, Bal Harbor, Florida. May 24 - 27","cited_year":"1993","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299853,"raw_reference":"[11] Institute of Clean Air Companies, (ICAC). Proceedings from ICAC Forum: Cutting NOx Emissions. March, 2000.","cited_authors":"[11] Institute of Clean Air Companies, (ICAC). Proceedings from ICAC Forum: Cutting NOx Emissions. March","cited_year":"2000","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299854,"raw_reference":"[12] State and Territorial Air Pollution Program Administrators (STAPPA) and Association 1-45 of Local Air Pollution Conrol Officials (ALAPCO). Controlling Nitrous Oxides. July 1994.","cited_authors":"[12] State and Territorial Air Pollution Program Administrators (STAPPA) and Association 1-45 of Local Air Pollution Conrol Officials (ALAPCO). Controlling Nitrous Oxides. July","cited_year":"1994","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299855,"raw_reference":"[13] Personal communication with Mike Knenlein of Fuel Tech to Paula Hemmer (PechanAvanti) on April 2, 2000. [14]","cited_authors":"[13] Personal communication with Mike Knenlein of Fuel Tech to Paula Hemmer (PechanAvanti) on April 2","cited_year":"2000","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299856,"raw_reference":"Group, Inc., Bechtel Power Corporation, and Science Applications International Corporation. May 1998. Investigation of Performance and Cost of NOx Controls as Applied to Group 2 Boilers. Revised Draft Report, prepared for the U.S. Environmental Protection Agency by The Cadmus Group, Inc., Bechtel Power Corporation, and Science Applications International Corporation. August 1996. Cost Estimates for Selected Applications of NOx Control Technologies on Stationary Combustion Boilers, Draft Report and Responses to Comments on the Draft Report. prepared for the U.S. Environmental Protection Agency by The Cadmus","cited_authors":"Group, Inc., Bechtel Power Corporation, and Science Applications International Corporation. May","cited_year":"1998","cited_title":"Investigation of Performance and Cost of NOx Controls as Applied to Group 2 Boilers","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299857,"raw_reference":"Group, Inc., and Bechtel Power Corporation. June 1997. Institute of Clean Air Companies (ICAC). Selective Catalytic Reduction (SCR) Control of NOx Emissions, Prepared by the ICAC SCR Committee, November 1997. U.S. EPA. Analyzing Electric Power Generation Under the CAAA. EPA Office of Air and Radiation, March 1998.","cited_authors":"Group, Inc., and Bechtel Power Corporation. June","cited_year":"1997","cited_title":"Institute of Clean Air Companies (ICAC)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299858,"raw_reference":"Rummenhohl, V., H. Weiler, and W. Ellison. Experience Sheds Light on SCR O&M Issues. Power Magazine, September 1992.","cited_authors":"Rummenhohl, V., H. Weiler, and W. Ellison. Experience Sheds Light on SCR O&M Issues. Power Magazine, September","cited_year":"1992","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299859,"raw_reference":"Pritchard, S., C. DiFrancesco, and T.R. von Alten. SCR Catalyst Performance Under Severe Operating Conditions. Presented at Power-Gen International ‘96 Conference and Exhibition, ASME, Orlando, FL. December 1996.","cited_authors":"Pritchard, S., C. DiFrancesco, and T.R. von Alten. SCR Catalyst Performance Under Severe Operating Conditions. Presented at Power-Gen International ‘96 Conference and Exhibition, ASME, Orlando, FL. December","cited_year":"1996","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299860,"raw_reference":"Harmgart, S., M. Meierer, and J. Fahlke. In-Service Assessment of DeNOx Catalysts. Presented at the International Joint Power Generation Conference and Exposition ‘98, ASME, Baltimore, MD, 1998.","cited_authors":"Harmgart, S., M. Meierer, and J. Fahlke. In-Service Assessment of DeNOx Catalysts. Presented at the International Joint Power Generation Conference and Exposition ‘98, ASME, Baltimore, MD","cited_year":"1998","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299861,"raw_reference":"Cochran, J.R., M.G. Gregory, and V. Rummenhohl. The Effect of Various Parameters on SCR System Cost. Presented at Power-Gen ’93, the Fourth International Power Generation Exhibition & Conference, ASME, Dallas, Texas, November 1993.","cited_authors":"Cochran, J.R., M.G. Gregory, and V. Rummenhohl. The Effect of Various Parameters on SCR System Cost. Presented at Power-Gen ’93, the Fourth International Power Generation Exhibition & Conference, ASME, Dallas, Texas, November","cited_year":"1993","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299862,"raw_reference":"[10] Electric Power research Institute. Technical Feasibility and Cost of Selective Catalytic Reduction (SCR) NOx Control. EPRI GS-7266, Final Report, May 1991. 2- 59 [11]","cited_authors":"[10] Electric Power research Institute. Technical Feasibility and Cost of Selective Catalytic Reduction (SCR) NOx Control. EPRI GS-7266, Final Report, May","cited_year":"1991","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299863,"raw_reference":"Emissions, Baltimore, MD, February 24-26, 1993. [12]","cited_authors":"Emissions, Baltimore, MD, February 24-26","cited_year":"1993","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299864,"raw_reference":"Engineering, Inc., Windsor, CT, 1981. Sigling, R. and R. Johnson. Current Practices for Monitoring Ammonia Slip from","cited_authors":"Engineering, Inc., Windsor, CT","cited_year":"1981","cited_title":"Sigling, R. and R. Johnson","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299865,"raw_reference":"SCR Processes. Presented at the 1998 Conference on Selective Catalytic and Non-catalytic Reduction for NOx Control, U.S. Department of Energy, Federal Energy Technology Center, Pittsburgh, PA, May 21-22, 1998.","cited_authors":"SCR Processes. Presented at the 1998 Conference on Selective Catalytic and Non-catalytic Reduction for NOx Control, U.S. Department of Energy, Federal Energy Technology Center, Pittsburgh, PA, May 21-22","cited_year":"1998","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299866,"raw_reference":"Cho, S.M. and S. Z. Dubow. Design of a Selective Catalytic Reduction System for NOx Abatement in a Coal-Fired Cogeneration Plant. Proceedings of the American Power Conference, Chicago, IL, pp. 717-722, April 1992. [15]","cited_authors":"Cho, S.M. and S. Z. Dubow. Design of a Selective Catalytic Reduction System for NOx Abatement in a Coal-Fired Cogeneration Plant. Proceedings of the American Power Conference, Chicago, IL, pp. 717-722, April","cited_year":"1992","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299867,"raw_reference":"ANSI K-61.1-1989. Safety Requirements for the Storage and Handling of Anhydrous Ammonia. Compressed Gas Association, Arlington, VA, March 1989.","cited_authors":"ANSI K-61.1-1989. Safety Requirements for the Storage and Handling of Anhydrous Ammonia. Compressed Gas Association, Arlington, VA, March","cited_year":"1989","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299868,"raw_reference":"Broske, D., G. Offen, and E. Cichanowicz. An Assessment of European Experience with Selective Catalytic Reduction for NOx Control. Presented at the “NOx Controls for Utility Boilers Workshop,” Baltimore, MD, August 1998, (“Proceedings: 1998 NOx Control Workshop,” EPRI report number TR-1113561998.). [19]","cited_authors":"Broske, D., G. Offen, and E. Cichanowicz. An Assessment of European Experience with Selective Catalytic Reduction for NOx Control. Presented at the “NOx Controls for Utility Boilers Workshop,” Baltimore, MD, August","cited_year":"1998","cited_title":"Proceedings: 1998 NOx Control Workshop","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299869,"raw_reference":"Staudt, J.E. Status Report on NOx Control Technologies and Cost Effectiveness for Utility Boilers. Published by Northeast States for Coordinated Air Use Management (NESCAUM) and Mid-Atlantic Regional Air Management Association (MARAMA), June 1998.","cited_authors":"Staudt, J.E. Status Report on NOx Control Technologies and Cost Effectiveness for Utility Boilers. Published by Northeast States for Coordinated Air Use Management (NESCAUM) and Mid-Atlantic Regional Air Management Association (MARAMA), June","cited_year":"1998","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299870,"raw_reference":"[20] S.C. Stultz and J. B. Kitto, eds. Steam, Its Generation and Use. 40th edition, Babcock& Wilcox, Inc., Barberton, Ohio, 1992. [21]","cited_authors":"[20] S.C. Stultz and J. B. Kitto, eds. Steam, Its Generation and Use. 40th edition, Babcock& Wilcox, Inc., Barberton, Ohio","cited_year":"1992","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299871,"raw_reference":"Green, D.W. and R.H. Perry, eds. Perry’s Chemical Engineers’ Handbook. 6th edition, McGraw Hill, Inc., 1984. [22]","cited_authors":"Green, D.W. and R.H. Perry, eds. Perry’s Chemical Engineers’ Handbook. 6th edition, McGraw Hill, Inc","cited_year":"1984","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299872,"raw_reference":"Durham, North Carolina, March 18-20, 1998.","cited_authors":"Durham, North Carolina, March 18-20","cited_year":"1998","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299873,"raw_reference":"[23] Electric Power Research Institute. Technical Assessment Guide. Vol. 1, Revision 7, 1993. [24]","cited_authors":"[23] Electric Power Research Institute. Technical Assessment Guide. Vol. 1, Revision 7","cited_year":"1993","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299874,"raw_reference":"TVA Paradise Unit 2, Presented at the Institute of Clean Air Companies ICAC Forum 2000, Washington D.C., March 23-24, 2000. [25]","cited_authors":"TVA Paradise Unit 2, Presented at the Institute of Clean Air Companies ICAC Forum","cited_year":"2000","cited_title":"Washington D.C., March 23-24, 2000","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299875,"raw_reference":"Stenger, H. G., et al, Low Temperature Selective Catalytic Reduction of NO, Presented at the Institute of Clean Air Companies ICAC Forum 2000, Washington D.C., March 23-24, 2000. 2- 61","cited_authors":"Stenger, H. G., et al, Low Temperature Selective Catalytic Reduction of NO, Presented at the Institute of Clean Air Companies ICAC Forum","cited_year":"2000","cited_title":"Washington D.C., March 23-24, 2000","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299876,"raw_reference":"Engineering, September 1990, pp. 116-121. Letter from Jose L. Bravo of Jaeger Products, Inc., to William M. Vatavuk, U. S. Environmental Protection Agency, June 8, 1992.","cited_authors":"Engineering, September","cited_year":"1990","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299877,"raw_reference":"Company, New York, 1980. Letter from Jack D. Brady of Anderson 2000, Inc., to William M. Vatavuk, U.S. Environmental Protection Agency, June 9, 1992. Letter from S. Raymond Woll of Air Products, Inc., to William M. Vatavuk, U.S. Environmental Protection Agency, June 25, 1992.","cited_authors":"Company, New York","cited_year":"1980","cited_title":"Letter from Jack D. Brady of Anderson 2000, Inc., to William M. Vatavuk, U.S. Environmental Protection Agency, June 9, 1992","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299878,"raw_reference":"Perry, R.H. and C.H. Chilton, Eds., Chemical Engineers’ Handbook (Sixth edition), McGraw-Hill Book Company, New York, 1984.","cited_authors":"Perry, R.H. and C.H. Chilton, Eds., Chemical Engineers’ Handbook (Sixth edition), McGraw-Hill Book Company, New York","cited_year":"1984","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299879,"raw_reference":"Crowe, Charles R., and D. Cooper, “Brick/Membrane Linings Pass the Acid Test”, Chemical Engineering, July 1988, pp. 83-86.","cited_authors":"Crowe, Charles R., and D. Cooper, “Brick/Membrane Linings Pass the Acid Test”, Chemical Engineering, July","cited_year":"1988","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299880,"raw_reference":"Harrison, Mark E., and John J. France, “Distillation Column Troubleshooting, Part 2: Packed Columns”, Chemical Engineering, April 1989, pp. 121-128. [10]","cited_authors":"Harrison, Mark E., and John J. France, “Distillation Column Troubleshooting, Part 2: Packed Columns”, Chemical Engineering, April","cited_year":"1989","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299881,"raw_reference":"Coker, A.K., “Understanding the Basics of Packed-Column Design”, Chemical Engineering Progress, November 1991, pp. 93-99.","cited_authors":"Coker, A.K., “Understanding the Basics of Packed-Column Design”, Chemical Engineering Progress, November","cited_year":"1991","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299882,"raw_reference":"Nealon, Norton Process Equipment, April 4, 1992.","cited_authors":"Nealon, Norton Process Equipment, April 4","cited_year":"1992","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299883,"raw_reference":"[12] Gas absorber questionnaire responses from nine gas absorber vendors to Radian Corporation August-December, 1991. [13]","cited_authors":"[12] Gas absorber questionnaire responses from nine gas absorber vendors to Radian Corporation August-December","cited_year":"1991","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299884,"raw_reference":"Pollutants, Volume I, CRC Press, Inc., Cleveland, Ohio, 1975. 1-44 [14]","cited_authors":"Pollutants, Volume I, CRC Press, Inc., Cleveland, Ohio","cited_year":"1975","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299885,"raw_reference":"Strigle, Ralph F., Random Packings and Packed Towers, Design Applications, Gulf Publishing Company, Houston, Texas, 1987.","cited_authors":"Strigle, Ralph F., Random Packings and Packed Towers, Design Applications, Gulf Publishing Company, Houston, Texas","cited_year":"1987","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299886,"raw_reference":"[15] Questionnaire response from K.C. Lang of Lantec Products, Inc. To R.V. Oommen, Radian Corporation, August 23, 1991.","cited_authors":"[15] Questionnaire response from K.C. Lang of Lantec Products, Inc. To R.V. Oommen, Radian Corporation, August 23","cited_year":"1991","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299887,"raw_reference":"[16] Memorandum from Vatavuk, W.M. of U.S. Environmental Protection Agency to Martha Smith, U.S. EPA, March 27, 1992.","cited_authors":"[16] Memorandum from Vatavuk, W.M. of U.S. Environmental Protection Agency to Martha Smith, U.S. EPA, March 27","cited_year":"1992","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299888,"raw_reference":"Corporation, August 1991 - January 1992. [18]","cited_authors":"Corporation, August 1991 - January","cited_year":"1992","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299889,"raw_reference":"[19] Vatavuk, W.M., and R.B. Neveril, “Estimating Costs of Pollution Control Systems, Part II: Factors for Estimating Capital and Operating Costs”, Chemical Engineering, November 3, 1980, pp. 157-162.","cited_authors":"[19] Vatavuk, W.M., and R.B. Neveril, “Estimating Costs of Pollution Control Systems, Part II: Factors for Estimating Capital and Operating Costs”, Chemical Engineering, November 3","cited_year":"1980","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299890,"raw_reference":"Agency, and Cindy Kling, City of Raleigh, N.C., July 16, 1992.","cited_authors":"Agency, and Cindy Kling, City of Raleigh, N.C., July 16","cited_year":"1992","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299891,"raw_reference":"[21] “Air Pollution Engineering Manual” (AP-40), (Second Edition), Danielson, John A., Los Angeles County Air Pollution Control District, CA, May 1973. For information on escalating these prices to more current dollars, refer to the EPA report Escalation Indexes for Air Pollution Control Costs and updates thereto, all of which are installed on the OAQPS Technology Transfer Network (CTC Bulletin Board). 1-45 Appendix A Properties of Pollutants 1-46 Table 1.7: List of Design Variables Variable Surface to volume ratio of packing Cross-sectional area of absorber Abscissa value from plot of generalized press drop correlation Absorption factor Diameter of absorber Diffusivity of pollutant in gas Diffusivity of pollutant in liquid Flooding factor Packing factor Waste gas flow rate entering absorber Waste gas flow rate exiting absorber Waste gas molar flow rate entering absorber Molar flow rate of pollutant free gas Waste gas superficial flow rate entering absorber Height of gas transfer unit Height of liquid transfer unit Height of overall transfer unit Height of packing Height of absorber Pressure drop constants Liquid rate entering absorber Liquid rate exiting absorber Liquid molar flow rate entering absorber Molar flow rate of pollutant free solvent Liquid superficial flow rate entering absorber Slope of equilibrium line Molecular weight of gas stream Molecular weight of the liquid stream Minimum wetting rate Number of overall transfer units","cited_authors":"[21] “Air Pollution Engineering Manual” (AP-40), (Second Edition), Danielson, John A., Los Angeles County Air Pollution Control District, CA, May","cited_year":"1973","cited_title":"For information on escalating these prices to more current dollars, refer to the EPA report Escalation Indexes for Air Pollution Control Costs and updates thereto, all of which are installed on the OAQPS Technology Transfer Network (CTC Bulletin Board)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299892,"raw_reference":"Viner, A. S., G. P. Greiner, D. F. Furlong, and R. G. Hurst, Pilot-Scale Evaluation of Top-Inlet and Advanced Electrostatic Filtration, October 1986 (EPA-600/7-86-042).","cited_authors":null,"cited_year":null,"cited_title":"Viner, A. S., G. P. Greiner, D. F. Furlong, and R. G. Hurst, Pilot-Scale Evaluation of Top-Inlet and Advanced Electrostatic Filtration, October 1986 (EPA-600/7-86-042)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299893,"raw_reference":"York, 1985. 1-56 Turner, J. H., “Bag Filtration,” in Handbook of Multiphase Systems, ed. by G. Hetsroni,","cited_authors":"York","cited_year":"1985","cited_title":"Bag Filtration","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299894,"raw_reference":"Hemisphere, New York, 1982. Turner, J. H., and J. D. McKenna, “Control of Particles by Filters,” in Handbook of Air Pollution Technology, ed. by S. Calvert and E. Englund, John Wiley & Sons, New York, 1984.","cited_authors":"Hemisphere, New York","cited_year":"1982","cited_title":"Control of Particles by Filters","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299895,"raw_reference":"Toronto, September 12 - 14, 1994, Air and Waste Management Association, Pittsburgh.","cited_authors":"Toronto, September 12 - 14","cited_year":"1994","cited_title":"Air and Waste Management Association, Pittsburgh","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299896,"raw_reference":"Broadway, R. M. and R. W. Cass, Fractional Efficiency of a Utility Boiler Baghouse: Nucla Generating Plant, August 1975 (EPA-600/2-75-013-a [NITS PB 246 641]).","cited_authors":null,"cited_year":null,"cited_title":"Broadway, R. M. and R. W. Cass, Fractional Efficiency of a Utility Boiler Baghouse: Nucla Generating Plant, August 1975 (EPA-600/2-75-013-a [NITS PB 246 641])","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299897,"raw_reference":"Cass, R. W. and R. M. Bradway, Fractional Efficiency of a Utility Boiler Baghouse: Sunbury Steam Electric Station, March 1976 (EPA-600/2-76-077a [NTIS PB253 943]). [10]","cited_authors":null,"cited_year":null,"cited_title":"Cass, R. W. and R. M. Bradway, Fractional Efficiency of a Utility Boiler Baghouse: Sunbury Steam Electric Station, March 1976 (EPA-600/2-76-077a [NTIS PB253 943])","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299898,"raw_reference":"Penny, C. W., Electrostatic Effects in Fabric Filtration: Volume 1. Fields, Fabrics, and Particles (Annotated Data), September 1978 (EPA-600/7-78-142A [NTIS PB 288576]). [11]","cited_authors":null,"cited_year":null,"cited_title":"Penny, C. W., Electrostatic Effects in Fabric Filtration: Volume 1","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299899,"raw_reference":"Frederick, E. R., Electrostatic Effects in Fabric Filtration: Volume 11. Triboelectric Measurements and Bag Performance, July 1978 (EPA600/7-78.lA2B [NTIS PB 287207]). [12]","cited_authors":null,"cited_year":null,"cited_title":"Frederick, E. R., Electrostatic Effects in Fabric Filtration: Volume 11","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299900,"raw_reference":"Specification, Pittsburgh, 1987.","cited_authors":"Specification, Pittsburgh","cited_year":"1987","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299901,"raw_reference":"[13] Dennis, R., et al.., Filtration Model for Coal Fly Ash with Glass Fabrics, August 1977 (EPA-600/7-77-084 [NITS PB 276489]). [14]","cited_authors":null,"cited_year":null,"cited_title":"[13] Dennis, R., et al.., Filtration Model for Coal Fly Ash with Glass Fabrics, August 1977 (EPA-600/7-77-084 [NITS PB 276489])","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299902,"raw_reference":"Dennis, R., and H. A. Klemm, “Modeling Concepts for Pulse Jet Filtration.” JAPCA, 30(l), January 1980. [15]","cited_authors":"Dennis, R., and H. A. Klemm, “Modeling Concepts for Pulse Jet Filtration.” JAPCA, 30(l), January","cited_year":"1980","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299903,"raw_reference":"Leith, D. and M. J. Ellenbecker, “Theory for Pressure Drop in a Pulse-Jet Cleaned Fabric Filter.” Atm. Environment, 14, 1980, pp. 845-852. [16]","cited_authors":"Leith, D. and M. J. Ellenbecker, “Theory for Pressure Drop in a Pulse-Jet Cleaned Fabric Filter.” Atm. Environment, 14","cited_year":"1980","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299904,"raw_reference":"Koehler, J. L. and D. Leith, “Model Calibration for Pressure Drop in a Pulse-Jet Cleaned Fabric Filter,” Atm. Environment, 17(10), 1983, pp. 1909-1913. 1-57 [17]","cited_authors":"Koehler, J. L. and D. Leith, “Model Calibration for Pressure Drop in a Pulse-Jet Cleaned Fabric Filter,” Atm. Environment, 17(10)","cited_year":"1983","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299905,"raw_reference":"Viner, A. S., and B. R. Locke, Cost and Performance Models for Electrostatically Stimulated Fabric Filters, April 1984 (EPA 600/8-84-016).","cited_authors":null,"cited_year":null,"cited_title":"Viner, A. S., and B. R. Locke, Cost and Performance Models for Electrostatically Stimulated Fabric Filters, April 1984 (EPA 600/8-84-016)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299906,"raw_reference":"[18] Northrop Services, Inc. Fabric Filter Workshop Reference Materials, 1977 Workshop, Air Pollution Training Institute. [19]","cited_authors":null,"cited_year":null,"cited_title":"[18] Northrop Services, Inc","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299907,"raw_reference":"Systems, Part XI: Estimate the Size and Cost of Baghouses,” Chemical Engineering, March 22, 1982, pp. 153-158. [20]","cited_authors":"Systems, Part XI: Estimate the Size and Cost of Baghouses,” Chemical Engineering, March 22","cited_year":"1982","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299908,"raw_reference":"Frey, R. F., and T. V. Reinauer, “New Filter Rate Guide,” Air Engineering, 30 April 1964. [21]","cited_authors":"Frey, R. F., and T. V. Reinauer, “New Filter Rate Guide,” Air Engineering, 30 April","cited_year":"1964","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299909,"raw_reference":"Owen, M. K. and A. S. Viner, Microcomputer Programs for Particulate Control, June 1985 (EPA-600/8-85-025a). [22]","cited_authors":null,"cited_year":null,"cited_title":"Owen, M. K. and A. S. Viner, Microcomputer Programs for Particulate Control, June 1985 (EPA-600/8-85-025a)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299910,"raw_reference":"Viner, A. S., et al., “Comparison of Baghouse Test Results with the GCA/EPA Design Model,” JAPCA, 34(8), August 1984. [24]","cited_authors":"Viner, A. S., et al., “Comparison of Baghouse Test Results with the GCA/EPA Design Model,” JAPCA, 34(8), August","cited_year":"1984","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299911,"raw_reference":"[25] R. S. Means Company, Inc., Means Construction Cost Data, 1998, Kingston, MA. [26]","cited_authors":"[25] R. S. Means Company, Inc., Means Construction Cost Data","cited_year":"1998","cited_title":"Kingston, MA. [26]","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299912,"raw_reference":"McGraw-Hill, New York, 1963, p. 6-20.","cited_authors":"McGraw-Hill, New York","cited_year":"1963","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299913,"raw_reference":"[28] Personal communication from Gary Greiner, ETS, Inc., to Jim Turner, Research Triangle Institute, October 24, 1986. [29]","cited_authors":"[28] Personal communication from Gary Greiner, ETS, Inc., to Jim Turner, Research Triangle Institute, October 24","cited_year":"1986","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299914,"raw_reference":"[30] Hosokawa Mikropul Environmental System, Cartridge Dust Collectors, product bulletin, undated (about 1997). 1-58","cited_authors":"[30] Hosokawa Mikropul Environmental System, Cartridge Dust Collectors, product bulletin, undated (about","cited_year":"1997","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299915,"raw_reference":"EPA/452/B-02-001 Chapter 2 Wet Scrubbers for Particulate Matter Daniel Mussatti Innovative Strategies and Economics Group Air Quality Strategies and Standards Division Office of Air Quality Planning and Standards U.S. Environmental Protection Agency Research Triangle Park, NC 27711 Paula Hemmer E.H. Pechan & Associates, Inc. 3622 Lyckan Parkway, Suite 2002","cited_authors":null,"cited_year":null,"cited_title":"EPA/452/B-02-001 Chapter 2 Wet Scrubbers for Particulate Matter Daniel Mussatti Innovative Strategies and Economics Group Air Quality Strategies and Standards Division Office of Air Quality Planning and Standards U.S. Environmental Protection Agency Research Triangle Park, NC 27711 Paula Hemmer E.H. Pechan & Associates, Inc","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299916,"raw_reference":"Publishing, Lancaster, PA, 1996. Davis, W.T. Ed., Air Pollution Engineering Manual (2nd Edition), Air and Waste","cited_authors":"Publishing, Lancaster, PA","cited_year":"1996","cited_title":"Davis, W.T. Ed., Air Pollution Engineering Manual (2nd Edition), Air and Waste","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299917,"raw_reference":"Management, John Wiley & Sons, Inc., New York, 2000. Environmental Protection Agency, U.S. (EPA), \"Stationary Source Control Techniques Document for Fine Particulate\", EPA Document No. EPA-452/R-97-001, Office of Air Quality Planning and Standards, Research Triangle Park, NC, September 30, 1997.","cited_authors":"Management, John Wiley & Sons, Inc., New York","cited_year":"2000","cited_title":"Stationary Source Control Techniques Document for Fine Particulate","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299918,"raw_reference":"Wark, K., C.F. Warner, and W.T. Davis, Air Pollution: Its Origin and Control (3rd Edition), Addison-Wesley, Reading, MA, 1998.","cited_authors":"Wark, K., C.F. Warner, and W.T. Davis, Air Pollution: Its Origin and Control (3rd Edition), Addison-Wesley, Reading, MA","cited_year":"1998","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299919,"raw_reference":"Press, Inc., Prospect Heights, IL, 1994. Environmental Protection Agency, U.S. (EPA), Air Pollution Technology Fact Sheet, Office of Air Quality Planning and Standards, Research Triangle Park, NC, 1990.","cited_authors":"Press, Inc., Prospect Heights, IL","cited_year":"1994","cited_title":"Environmental Protection Agency, U.S. (EPA), Air Pollution Technology Fact Sheet, Office of Air Quality Planning and Standards, Research Triangle Park, NC, 1990","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299920,"raw_reference":"Avallone, E. and T. Baumeister, Mark's Standard Handbook for Mechanical Engineers, McGraw Hill, New York, 1996. The Scrubber Manual (Revised), The McIlvaine Company, Northbrook, IL, 1995. Advanced Air Technologies, Inc., technical information on scrubbers, www.aatinc.com/ scrubbing_zone.htm, 2002. [10]","cited_authors":"Avallone, E. and T. Baumeister, Mark's Standard Handbook for Mechanical Engineers, McGraw Hill, New York","cited_year":"1996","cited_title":"The Scrubber Manual (Revised), The McIlvaine Company, Northbrook, IL, 1995","cited_venue":null,"cited_doi":null,"cited_url":"www.aatinc.com/","ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299921,"raw_reference":"William L. Heuman, Industrial Air Pollution Control Systems, McGraw-Hill, Washington D.C., 1997.","cited_authors":"William L. Heuman, Industrial Air Pollution Control Systems, McGraw-Hill, Washington D.C","cited_year":"1997","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299922,"raw_reference":"[16] Hesketh, H.E., “Fine Particulate Collection Efficiency Related to Pressure Drop, Scrubbant and Particle Properties, and Contact Mechanisims,” Journal of Air Pollution Control Association, vol. 24, no. 10, 1974. [17]","cited_authors":"[16] Hesketh, H.E., “Fine Particulate Collection Efficiency Related to Pressure Drop, Scrubbant and Particle Properties, and Contact Mechanisims,” Journal of Air Pollution Control Association, vol. 24, no. 10","cited_year":"1974","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299923,"raw_reference":"Lapple, C.E. and H.J. Kamack, “Performance of Wet Dust Scrubbers”, Chemical Engineering Progress, vol. 51, March 1955. [18]","cited_authors":"Lapple, C.E. and H.J. Kamack, “Performance of Wet Dust Scrubbers”, Chemical Engineering Progress, vol. 51, March","cited_year":"1955","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299924,"raw_reference":"Semrau, K.T., “Dust Scrubber Design - A Critique on the State of the Art,” ,” Journal of Air Pollution Control Association, vol.13, December 1963. [19]","cited_authors":"Semrau, K.T., “Dust Scrubber Design - A Critique on the State of the Art,” ,” Journal of Air Pollution Control Association, vol.13, December","cited_year":"1963","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299925,"raw_reference":"Semrau, K.T., “Practical Process Design of Particulate Scrubbers”, in Industrial Air Pollution Engineering, V. Casaseno, ed., McGraw Hill, New York, 1980.","cited_authors":"Semrau, K.T., “Practical Process Design of Particulate Scrubbers”, in Industrial Air Pollution Engineering, V. Casaseno, ed., McGraw Hill, New York","cited_year":"1980","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299926,"raw_reference":"[20] “Scrubber Selection Guide”, Calvert Environmental Equipment, San Diego, 1988. [21]","cited_authors":"[20] “Scrubber Selection Guide”, Calvert Environmental Equipment, San Diego","cited_year":"1988","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299927,"raw_reference":"Handbook, CRC Press, Washington D.C., 2002. [22]","cited_authors":"Handbook, CRC Press, Washington D.C","cited_year":"2002","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299928,"raw_reference":"Publishers, Washington D.C., 2002.","cited_authors":"Publishers, Washington D.C","cited_year":"2002","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299929,"raw_reference":"[23] Calvert, S., How to choose a particulate scrubber, Chem. Eng., 54-68, August 29, 1977.","cited_authors":"[23] Calvert, S., How to choose a particulate scrubber, Chem. Eng., 54-68, August 29","cited_year":"1977","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299930,"raw_reference":"Hemmer, E.H. Pechan and Associates, Inc., June, 2002. 2-60","cited_authors":"Hemmer, E.H. Pechan and Associates, Inc., June","cited_year":"2002","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299931,"raw_reference":"[1] White, H. J., Industrial Electrostatic Precipitation, Addison-Wesley, Reading, MA, 1963.","cited_authors":"[1] White, H. J., Industrial Electrostatic Precipitation, Addison-Wesley, Reading, MA","cited_year":"1963","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299932,"raw_reference":"Precipitation, S. Masuda, ed., Kyoto, 1984, pp. 513-522.","cited_authors":"Precipitation, S. Masuda, ed., Kyoto","cited_year":"1984","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299933,"raw_reference":"[5] Correspondence: James Jessup (M&W Industries, Inc., Rural Hall, NC) to William M. Vatavuk, May 16, 1986.","cited_authors":"[5] Correspondence: James Jessup (M&W Industries, Inc., Rural Hall, NC) to William M. Vatavuk, May 16","cited_year":"1986","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299934,"raw_reference":"[6] Matley, Jay (ed.), Modern Cost Engineering, McGraw-Hill, New York, 1984, p. 142.","cited_authors":"[6] Matley, Jay (ed.), Modern Cost Engineering, McGraw-Hill, New York","cited_year":"1984","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299935,"raw_reference":"[7] Correspondence: Joseph Bruno (AirPol, Inc.) to SAIC, August 26, 1999.","cited_authors":"[7] Correspondence: Joseph Bruno (AirPol, Inc.) to SAIC, August 26","cited_year":"1999","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299936,"raw_reference":"[8] Correspondence: Sam Dunkle (Fisher-Klosterman, Inc.) to SAIC, August 26, 1999.","cited_authors":"[8] Correspondence: Sam Dunkle (Fisher-Klosterman, Inc.) to SAIC, August 26","cited_year":"1999","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299937,"raw_reference":"[9] Correspondence: James Reynolds (Croll-Reynolds Clean Air Tecnologies) to SAIC, September 1, 1999.","cited_authors":"[9] Correspondence: James Reynolds (Croll-Reynolds Clean Air Tecnologies) to SAIC, September 1","cited_year":"1999","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299938,"raw_reference":"[10] Personal communication: Robert Shipe, Jr. (American Air Filter Co., Louisville, KY), and S. A. Sauerland (United Air Specialists, Inc., Cincinnati, OH), to Roger Ellefson (JACA Corp., Fort Washington, PA), June 1987.","cited_authors":"[10] Personal communication: Robert Shipe, Jr. (American Air Filter Co., Louisville, KY), and S. A. Sauerland (United Air Specialists, Inc., Cincinnati, OH), to Roger Ellefson (JACA Corp., Fort Washington, PA), June","cited_year":"1987","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299939,"raw_reference":"[11] R.S. Means Company, Inc., Means Square Foot Costs 1987, Kingston, MA.","cited_authors":"[11] R.S. Means Company, Inc., Means Square Foot Costs","cited_year":"1987","cited_title":"Kingston, MA","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299940,"raw_reference":"[12] Telecon: Gary Greiner (ETS, Inc., Roanoke, VA) to James H. Turner, October 1986.","cited_authors":"[12] Telecon: Gary Greiner (ETS, Inc., Roanoke, VA) to James H. Turner, October","cited_year":"1986","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299941,"raw_reference":"[13] PEDCo Environmental, Inc., Operating and Maintenance Manual for ESPs, Publication No. EPA/625/1-85/017, Office of Research and Development, Air and Energy Engineering Research Lab, Research Triangle Park, NC, September 1985.","cited_authors":"[13] PEDCo Environmental, Inc., Operating and Maintenance Manual for ESPs, Publication No. EPA/625/1-85/017, Office of Research and Development, Air and Energy Engineering Research Lab, Research Triangle Park, NC, September","cited_year":"1985","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299942,"raw_reference":"[14] Perry,, R. H., et al., Perry’s Chemical Engineers Handbook (Sixth Edition), McGrawHill, New York, 1984. 3-60 [15]","cited_authors":"[14] Perry,, R. H., et al., Perry’s Chemical Engineers Handbook (Sixth Edition), McGrawHill, New York","cited_year":"1984","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299943,"raw_reference":"Particles, Pensacola, FL, September 30 to October 2, 1974, Publication No. EPA 650/ 2-75-016, 1975.","cited_authors":"Particles, Pensacola, FL, September 30 to October 2","cited_year":"1974","cited_title":"Publication No","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299944,"raw_reference":"[16] Beltran Associates, Inc., “Poly-Stage Precipitator for Stack and Duct Emissions,” November 1978. [17]","cited_authors":"[16] Beltran Associates, Inc., “Poly-Stage Precipitator for Stack and Duct Emissions,” November","cited_year":"1978","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299945,"raw_reference":"Vatavuk, W.M., and R.B. Neveril, “Estimating Costs of Air-Pollution Control Systems, Part XVII: Particle Emissions Control,” Chemical Engineering (adapted), April 2, 1984, pp. 97-99. [18]","cited_authors":"Vatavuk, W.M., and R.B. Neveril, “Estimating Costs of Air-Pollution Control Systems, Part XVII: Particle Emissions Control,” Chemical Engineering (adapted), April 2","cited_year":"1984","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299946,"raw_reference":"Gumerman, R.C., B.E. Burris, and S.P. Hansen, Estimation of Small System Water Treatment Costs, Publication No. EPA/600/2-84/184a, NTIS No. PB85-161644, 1984. [19]","cited_authors":"Gumerman, R.C., B.E. Burris, and S.P. Hansen, Estimation of Small System Water Treatment Costs, Publication No. EPA/600/2-84/184a, NTIS No. PB85-161644","cited_year":"1984","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1299947,"raw_reference":"Enhancement, Electric Power Research Institute Report No. CS-4145, 1985. 3-61 Appendix A Effects of Material Thickness and Type on ESP Costs 3-62 The impact of material thickness and composition of collecting plates and the ESP casing can be estimated using the following equations and Figure 6.17: Plates:  W t   2 × F S  − 0 .90  M + SP (3.54)  W t   10 × F S  − 0 .58  M + SP (3.55) Casing: where incremental increase of flange-to-flange selling price ($/ft2) weight of steel (lb/ft2) fabricated steel selling price ($/lb) (normally assume approximately 2 times material cost) manufacturer’s markup factor of fabricated cost (direct labor, wages, and material cost before general and administrative expense and profit) to selling price (normally 2 to 3) flange-to-flange selling price from Figure 6.17 ($/ft2) Most vendors can produce ESPs with collecting plate material thicknesses from 16 to 20 gauge and casing material thicknesses from 1/8 through 1/4 in. without affecting the 2 times material cost = fabricated cost relationship. Thus, the impact of increasing the collecting plates from 18 to 16 gauge and the casing from 3/16 to 1/4 in. plate on a 72,000 ft2 collector having a selling price of $10/ft2 and assuming a markup factor of 2 is as follows: Plates: 3-63   2 .5   2 × 0 .90  − 0 .90  2 + 10","cited_authors":"Enhancement, Electric Power Research Institute Report No. CS-4145","cited_year":"1985","cited_title":"3-61 Appendix A Effects of Material Thickness and Type on ESP Costs 3-62 The impact of material thickness and composition of collecting plates and the ESP casing can be estimated using the following equations and Figure 6.17: Plates:  W t   2 × F S  − 0 .90  M + SP (3.54)  W t   10 × F S  − 0 .58  M + SP (3.55) Casing: where incremental increase of flange-to-flange selling price ($/ft2) weight of steel (lb/ft2) fabricated steel selling price ($/lb) (normally assume approximately 2 times material cost) manufacturer’s markup factor of fabricated cost (direct labor, wages, and material cost before general and administrative expense and profit) to selling price (normally 2 to 3) flange-to-flange selling price from Figure 6.17 ($/ft2) Most vendors can produce ESPs with collecting plate material thicknesses from 16 to 20 gauge and casing material thicknesses from 1/8 through 1/4 in","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null}]}