Toxicological Profile for Iodine - DCN SE07363
Other documents for the same rulemaking
References: 1,930 extracted, 2 linked to papers
NCI 1997 Chernobyl power plant accident 3,200
UNSCEAR 2000 Hanford Nuclear Site nuclear fuel processingrelated releases
CDC 1999 Three Mile Island power plant accident 0.0004–0.0011
NRC 1995 I Released (PBq)a 1 PBq=27,000 Ci
ACUTE EXPOSURE Death Human (death) Finkelstein and Jacobi 1937 I2, Nal3 Systemic Human 14 d Endocr Chow et al. 1991 0.0086 0.0086 Human Endocr Delange 1996 Iodized oil Human 14 d Endocr Gardner et al. 1988 0.069 0.069 Human Endocr Georgitis et al. 1993 0.46 0.46 I2, I- Human 14 d Endocr Paul et al. 1988 0.024 0.024 (continued) Table 3-1 Levels of Significant Exposure to Iodine - Chemical Toxicity - Oral Key to Species figure (Strain) Human Exposure/ Duration/ Frequency (Specific Route) 14 d
LOAEL System Endocr NOAEL Less Serious (mg/kg/day) (mg/kg/day) Serious Reference (mg/kg/day) Chemical Form Robison et al. 1998 Human 14 d Endocr Robison et al. 1998 Immuno/ Lymphoret Human (fever) Horn and Kabins 1972 Human (ioderma) Soria et al. 1990
INTERMEDIATE EXPOSURE Death Human 9 mo (death from tracheal compression by goiter) Galina et al. 1962 Human 9 mo (death from tracheal compression by goiter) Galina et al. 1962 (continued) Table 3-1 Levels of Significant Exposure to Iodine - Chemical Toxicity - Oral Key to Species figure (Strain) Exposure/ Duration/ Frequency (Specific Route)
LOAEL System NOAEL Less Serious (mg/kg/day) (mg/kg/day) Serious Reference (mg/kg/day) Chemical Form Systemic Human 4 mo Endocr (clinical hyperthyroidism with thyrotoxicosis) Ahmed et al. 1974 Human 2 mo Endocr (goiter in neonate) Coakley et al. 1989 Human 9 mo Endocr (goiter and hypothyroidism in neonate) Hassan et al. 1968 Human 11 wk Endocr Jubiz et al. 1977 Human 90 d Endocr 0.0039 0.46 0.0039 (subclinical hypothyroidism with gland enlargement) LeMar et al. 1995 I2 ,I- 0.46 Human 9 mo Endocr Liesenkotter et al. 1996 0.0047 0.0047 Table 3-1 Levels of Significant Exposure to Iodine - Chemical Toxicity - Oral Key to Species figure (Strain) Human Exposure/ Duration/ Frequency (Specific Route) 9 mo (continued)
LOAEL System NOAEL Less Serious (mg/kg/day) (mg/kg/day) Serious Reference (mg/kg/day) Chemical Form Endocr (goiter, hypothyroidism in neonate) Martin and Rento 1992 Human 28 d Endocr 0.39 Namba et al. 1993 (subclinical hypothyroidism with gland enlargement) 0.39 Human 3 mo Endocr (goiter in neonate) Penfold et al. 1978 Human 4 mo Endocr (goiter in neonate) Penfold et al. 1978 Human 6 mo Endocr 0.05 (clinical hypothyroidism) 0.05 Shilo and Hirsch 1986 sea-kelp Human 7 wk Endocr (clinical hyperthyroidism with thyrotoxicosis) Vagenakis et al. 1972 Human 9 mo Endocr (goiter in fetus) Vicens-Colvet et al. 1998 (continued) Table 3-1 Levels of Significant Exposure to Iodine - Chemical Toxicity - Oral Key to Species figure (Strain) Exposure/ Duration/ Frequency (Specific Route)
LOAEL System NOAEL Less Serious (mg/kg/day) (mg/kg/day) Immuno/ Lymphoret Human Serious Reference (mg/kg/day) Chemical Form (fever) Horn and Kabins 1972 Human 6 mo (ioderma) Kincaid et al. 1981 Human 8 mo (ioderma) Soria et al. 1990
CHRONIC EXPOSURE Systemic Human 11 yr Endocr 0.029 0.01 0.01 Boyages et al. 1989 (subclinical hypothyroidism with gland enlargement) 0.029 Human 2 yr Endocr (clinical hypothyroidism with goiter in neonate) Iancu et al. 1974 Human Endocr (goiter with elevated serum
TSH) Khan et al. 1998 Table 3-1 Levels of Significant Exposure to Iodine - Chemical Toxicity - Oral Key to Species figure (Strain) Human Exposure/ Duration/ Frequency (Specific Route) 46 yr (continued)
LOAEL System NOAEL Less Serious (mg/kg/day) (mg/kg/day) Serious Reference (mg/kg/day) Chemical Form 0.22 Endocr Konno et al. 1994 (clinical hypothyroidism without Iautoimmunity) 0.22 Human 68 yr (F, W) Endocr Laurberg et al. 1998 0.0046 0.0046 Human 16 mo Endocr Pedersen et al. 1993 0.0039 0.0039 Human 81 yr (F, W) Endocr 0.012 0.0023 0.0023 Szablocs et al. 1997 (clinical hypothyroidism without Iautoimmunity; elderly adults) 0.012 Immuno/ Lymphoret 15 yr Human (fever) Kurtz and Aber 1982 Human 1 yr (ioderma) Rosenberg et al. 1972 Cancer Human 0.0035 (thyroid cancer; in endemic goiter area) 0.0035 Bacher-Stier et al. 1997 Table 3-1 Levels of Significant Exposure to Iodine - Chemical Toxicity - Oral Key to Species figure (Strain) Human Exposure/ Duration/ Frequency (Specific Route) (continued)
LOAEL System NOAEL Less Serious (mg/kg/day) (mg/kg/day) Serious Reference (mg/kg/day) Chemical Form 0.0035 (thyroid cancer; in endemic goiter area) Harach and Williams 1995 0.0035 a The number corresponds to entries in Figure 3-1. b Used to derive an acute oral MRL based on a no-observed-effect-level (NOEL) of 0.01mg/kg/day in healthy adult humans, for changes in serum thyroid hormone levels. The no-observed-adverse-effect-level (NOAEL) is 0.024 mg/kg/day. c Used to derive a chronic oral MRL of 0.005 mg/kg/day; dose divided by an uncertainty factor of 2 for human variability. (C) = capsule; d = day(s); Endocr = endocrine; (F) = feed; kg = kilogram(s); LOAEL = lowest-observed-adverse-effect level; mg = milligram(s); mo = month(s); NOAEL = no-observed-adverse-effect level; NA = not specified; TSH = thyroid-stimulating hormone; (W) = drinking water; wk = week(s); yr = year(s) Figure 3-1. Levels of Significant Exposure to Iodine - Chemical Toxicity - Oral Acute (≤14 days) Systemic mg/kg/day 0.01 0.001 c-Cat d-Dog r-Rat p-Pig q-Cow -Humans k-Monkey m-Mouse h-Rabbit a-Sheep f-Ferret n-Mink j-Pigeon o-Other e-Gerbil
ACUTE EXPOSURE Systemic Human Endocr (thyroid gland nodularity) Astakhova et al. 1996 131 I Human Endocr (thyroid gland nodularity) Conard 1984 131 I Human Endocr 2000 (thyroid gland nodularity) 2000 Hamilton et al. 1987 131 I Human Endocr (thyroid gland nodularity) Pacini et al. 1997 131 I Cancer Human (thyroid cancer) Astakhova et al. 1998 131 I Human (thyroid cancer) Drobyshevskaya et al. 1996 131 I Human (kidney and liver cancer) Holm et al. 1991 131 I (continued) Table 3-2 Levels of Significant Exposure to Iodine - Radiation Toxicity - Oral Key to Species figure (Strain) Human Exposure/ Duration/ Frequency (Specific Route)
LOAEL System NOAEL Less Serious (rad) (rad) Serious (rad) 6000 (thyroid cancer) 6000 Reference Chemical Form Ron et al. 1998 131 I Human (thyroid cancer) Tronko et al. 1996 131 I
CHRONIC EXPOSURE Systemic Human Endocr CDC 2002 131 I Cancer Human (thyroid neoplasm) Gilbert et al. 1998 131 I Human (thyroid neoplasm) Kerber et al. 1993 131 I Human (thyroid neoplasm) a the number corresponds to entries in Figure 3-2. Endocr = endocrine; (f) = feed; LOAEL = lowest-observed-adverse-effect level Rallison 1996 131 I Figure 3-2. Levels of Significant Exposure to Iodine - Radiation Toxicity - Oral Acute (≤14 days) Systemic mg/kg/day 10000 1000 *Doses represent the lowest dose tested per study that produced a tumorigenic response and do not imply the existence of a threshold for the cancer endpoint. c-Cat d-Dog r-Rat p-Pig q-Cow -Humans k-Monkey m-Mouse h-Rabbit a-Sheep f-Ferret n-Mink j-Pigeon o-Other e-Gerbil s-Hamster g-Guinea Pig Cancer Effect Level-Animals
INAA (γ-ray 0.01 µg/L spectrometry) Ohno 1971 As-Ce catalytic spectro photometry 96–97% Benotti and Benotti 1963; Benotti et al. 1965 No data Ballad et al. 1976, Boulos et al. 1973, Oliver et al. 1982b
EPA 1986 INAA (γ-ray 9.4–2,880 ng/g spectrometry) (range of measured values) No data Hou et al. 1997b Neutron activation plus mass spectrometry Between 0.01 and 0.06 µg per sample (0.02–0.50 mL sample volume) 0.11–2.17 mg/g (range of measured values)
IODINE 7. ANALYTICAL METHODS Table 7-1. Analytical Methods for Determining Iodine in Biological Samples Sample matrix Bread Preparation method Bread is dried; ground; treated with 2N Na2CO3 plus 1% KClO3; dried; incinerated; dissolved; analyzed by the ceric arsenite reaction Analytical method Sample detection limit Percent recovery Reference As-Ce catalytic spectro photometry 0.05 µg/g No data Sachs et al. 1972 As-Ce catalytic spectrophotometry = arsenious-ceric ion catalytic spectrophotometry; HPLC = high performance liquid chromatography; ICP-AES = inductively coupled plasma-atomic emission spectrometry; INAA = instrument neutron activated analysis; UV = ultraviolet/visible
INAA and ICP-AES methods offer the greatest sensitivity for the detection of iodine in human samples (Table 7-1). An example of an application of INAA to the measurement of iodine in urine involves a prepurification of the urine sample to remove interfering ions, such as bromide, upon activation by neutrons (photopeaks are 0.45 MeV for 128I and 0.55 MeV for 82Br). The urine sample is first passed over Dowex 1X8 anion exchange resin, and then followed by the fusion of the washed and dried resin with NaOH/HNO3. The fusion residue is dissolved in water with a 0.5 mL aliquot transferred to a polyethylene sheet and dried. The sample is then irradiated with neutrons, dissolved in a solution containing an iodide carrier, extracted with trioctylamine/xylene, back extracted first with 1 M sodium nitrate to remove bromine, and then back extracted into 1 N ammonia. From here, the iodine is precipitated as silver iodide, filtered, and analyzed by gamma-ray spectrometry (Ohno 1971).
IODINE 7. ANALYTICAL METHODS Table 7-2. Analytical Methods for Determining Radioiodine in Biological Samples Sample matrix Urine Preparation method Analytical method Sample transferred to Marinelli beaker and counted I counted directly in thyroid tissue Sample detection Percent limit recovery Reference γ-Spectrometry 100 pCi/L ( I) Gautier 1983 with NaI detector X-Ray 0.04 pCi/g (129I) No data Thyroid spectrometry Middlesworth with HP Ge 1993 detector No data Boulos et al. Thyroid Powdered or fresh tissue Neutron 45 pg/g (129I) 1973; Oliver digested with H2SO4; iodide activation and et al. 1982b converted to Al2I6; neutron mass irradiated, and iodine spectrometry precipitated with Pd Handl et al. Thyroid Tissue sample were
INAA with 18–74 fCi/g (129I) and other lyophiized and ground; Ge(Li) (thyroid) 1990 50–60% tissues pyrolyzed in O2/N2 stream; γ-spectrometry iodine absorbed onto (other charcoal; iodine liberated tissues) from charcoal by heating; isolated by distillation on cooled glass and then neutron irradiated Saliva Saliva samples obtained Scintillation 1.26–36.5 nCi/mL No data Nishizawa and directly counted counter (range of et al. 1985 measured values) (125I) Feces Sample directly counted in γ-Spectrometry 0.14 nCi/L (131I) No data Lipsztein et al detector with NaI 1991 detector Cow’s milk Sample (50–100 mL) γ-Spectrometry 4–100 pCi/L (range No data Ekman et al. directly counted in iron with NaI of measured 1967 shielded gamma detector values) (131I) spectrometer 58% raw Gabay et al. Cow’s milk Conversion of iodine to Liquid 0.3 pCi/L (129I) iodide; concentrated on scintillation milk, 80% 1974 anion exchange resin; counter pasteurized milk; with extracted through CCl4, water, then toluene 30 mg iodine carrier No data Cunningham Food Food samples directly γ-Spectrometry 0.05 pCi/g (131I) counted in gamma-ray with NaI or et al. 1989, spectrometer Ge(Li) detector 1994
IODINE 7. ANALYTICAL METHODS methods, providing limits of detection (50 and 0.3 ng/g, respectively) that are appropriate for performing trace analysis of iodine in a large number of environmental and biological samples (Gélinas et al. 1998). Accuracy of in vivo and in vitro measurements of iodine and its radioisotopes is determined through the use of standard, certified solutions or radioactive sources with known concentrations or activities of iodine. National Institute of Standards and Technology (NIST) traceable standards for 125I and 127I can be obtained through a number of commercial sources. The primary source of certified iodine radioisotope standards is the NIST. Standard reference materials (SRM) for 129I (SRM 4401LZ, 30MBq [0.8 mCi]) and 131I (SRM 4949C, 17 kBq [0.45 µCi]) are available from NIST. SRMs are also available for 127I measurements, including SRM 909 (serum), SRM 1486 (bone meal), SRM 1548 (mixed diet), SRM 1549 (nonfat milk powder), SRM 1846 (infant formula), and SRM 2383 (baby food). 7.2 ENVIRONMENTAL SAMPLES There are two common approaches for measuring iodine radioisotopes in the environment. Iodine radioisotopes can either be measured directly in the field (in situ) using portable survey instruments or samples can be procured from the field and returned to the laboratory for quantification of iodine.
However, quantification of the stable iodine isotope in environmental samples is generally conducted in the laboratory. 7.2.1 Field Measurements of Iodine In situ measurement techniques are extremely useful for the rapid characterization of radionuclide contamination in the environment, such as soils, sediments, and vegetation, or when monitoring personnel for exposure to radionuclides. The measurement of gamma-ray-emitting radionuclides in the environment is conducted with portable survey instruments such as Gieger-Mueller detectors, sodium iodide scintillation detectors, and gamma-ray spectrometers. However, the use of gamma-spectrometers in field survey equipment is preferred for measuring 131I in the field because of their selectivity and sensitivity (EML 1997). The energy and penetrance of the gamma-rays that are emitted during the decay of 131I provides an advantage for assessing the level of iodine both on and below the surface using portable field survey instruments such as the gamma-ray spectrometer (EML 1997). These gamma-ray spectrometers are equipped with a high purity germanium detector that is able to resolve the 364 keV gamma-ray emitted from 131I from the gamma-rays emitted from other radionuclides; for example, 40K
IODINE 7. ANALYTICAL METHODS (USNRC 1997). The concentration and distribution of 131I that have been detected in the field will need to be determined by laboratory-based analyses of soil samples procured from the survey area. 7.2.2 Laboratory Analysis of Environmental Samples Analytical methods for quantifying iodine and iodine radioisotopes in environmental samples (e.g., air, water, soil, biota, and food) are summarized in Tables 7-3 (127I) and 7-4 (125I, 129I, and 131I). The methods that are commonly used in the analysis of 127I are based on instrument-based analytical techniques, such as spectrophotometry, electrochemistry, INAA, mass spectrometry (MS), and some colorimetric techniques. The analysis of 125I, 129I, and 131I can be determined either as total mass or total activity, depending on the analytical technique that is used. Typically, radiochemical methods of analysis employing gamma-ray spectrometry and β-γ coincidence scintillation techniques are used to quantify 125I and 131I in environmental samples. However, more sensitive analytical techniques, such as INAA and
INAA (Sheridan and Zoller 1989; Tsukada et al. 1991), nondestructive neutron activation analysis (Dams
HPLC with UV 0.05 µg/L detection 110–111% Weinberg and (at 0.5– Yamada 1997 2.0 µg/L) Electrothermal 3.0 µg/L atomic absorption spectrometry 94.8– Bermejo 104.4% Barrera et al. 1994 5–20 µg/L) 0.1 µg/L As-Ce catalytic spectrophoto metry 0.1 µg/L Iodine-iodide is removed from As-Ce sample through extraction catalytic into chloroform as ion-pair spectrophoto with tetraphenylarsonium metry cation 0.20 µg/L One liter sample is acidified
INAA using with nitric acid; 5 mL sample Ge(Li) is irradiated, filtered, and γ-spectrometry counted K2CO3 added to sample; Spectrophoto 0.2 µg/L centrifuged to remove metry precipitated alkaline earth metals; iodine measured by addition of nitric acid, NaCl, NH4Fe(SO4)2 and KSCN 100% Jones et al. 1982b -100% (at 2 µg/L iodate) Jones et al. 1982b No data Salbu et al. 1975 90–108% Moxon 1984
Soil, sediments, Sample dried and pulverized; rock mixed with V2O5 and pyrohydrolyzed; evolved iodine dissolved in NaOH solution digested with acid Coal and fly <250 mg samples dried; irradiated with neutrons and then counted Vegetation Sample prepared by microwave digestion using HNO3/H2O2; treated with Na2S2O3 or ascorbic acid solution to convert iodate to iodide Analytical method Sample detection limit Percent recovery As-Ce 0.05 µg/g (0.5 g catalytic sample size) spectrophoto metry 75–90% Rae and Malik 1996
ICP-MS 100 pg/g No data Germani et al. 1980 96–104% Kerl et al. 1996 Reference As-Ce catalytic spectrophotometry = arsenious-ceric ion catalytic spectrophotometry; GC-ECD = gas chromatographyelectron capture detection; HPLC = high performance liquid chromatography; ICP-AES = inductively coupled plasmaatomic emission spectrometry; ICP-MS = inductively coupled plasma-mass spectrometry; IDMS = isotope dilution mass spectrometry; INAA = instrumental neutron activation analysis; UV detection = ultraviolet/visible detection
INAA with Ge γ-ray detector 0.24–0.26 aCi/m3 No data (range of measured values) (129I) Tsukada et al. 1991 γ-Spectrometry with Ge detector <1 pCi/L (131I) No data
ASTM 1995 β-γ Coincidence 0.1 pCi/L (131I) scintillation system No data
EPA 1976, 1980 IODINE 7. ANALYTICAL METHODS Table 7-4. Analytical Methods for Determining Radioiodine in Environmental Samples Sample matrix Preparation method Analytical method Sample detection limit Iodate carrier and tartaric Β-γ Coincidence 0.1 pCi/L ( I) acid are added to scintillation system sample, HNO3 added and sample distilled into NaOH solution; distillate acidified with H2SO4 and oxidized with NaNO2; extracted into CCl4; back extracted into NaHSO3; and iodide reprecipitated as PdI2 Liquid scintillation 0.3 pCi/L (129I) Fresh water Conversion of iodine to iodide; concentrated on counter anion exchange resin; extracted with CCl4, water, then toluene γ-Spectrometry 30 pCi/L (125I) Fresh water Iodide carrier added to sample; treated with HCl with Ge(Li) detector and and sodium x-ray fluorescence metabisulfite; iodide concentrated on a strong for yield correction anion exchange resin with iodine carrier; 125I directly detected on resin River water Sample directly analyzed ICP-MS 0.5 pCi/L (129I) or concentrated on an
EPA 1976 74% with 30 mg iodine carrier Gabay et al. 1974 No data Howe and Bowlt 1991 No data Beals and Hayes 1995; Beals et al. 1992 Anderson 1978
DOE 1994; Elmore and Phillips 1987; Elmore et al. 1980 92–100% at ASTM 2–94 pCi/L 1998 No data Sodd et al. 1975 No data Prichard et al. 1981 No data Lindstrom et al. 1991; Lutz et al. 1984 Cox et al. 1992
INAA with Ge(Li) γ-spectrometry 18–74 fCi/g (129I) 50–60% Reference Handl et al. 1990
IODINE 7. ANALYTICAL METHODS the intrinsic detection capability of a measurement procedure (sampling through data reduction and reporting) to aid in determining which method is best suited for the required sample quantification (EML 1997; USNRC 1984). Several factors influence the LLD, including background counting-rates, size or concentration of sample, detector sensitivity, recovery of desired analyte during sample isolation and purification, level of interfering contaminants, and, particularly, counting time. Because of these variables, the LLDs between laboratories, utilizing the same or similar measurement procedures, will vary. The accuracy of a measurement technique in determining the quantity of a particular analyte in environmental samples is greatly dependent on the reliability of the calibrating technique. Thus, the availability of standard, certified radiation sources with known concentrations of iodine and its radioisotopes are required in order to insure the reliability of the calibration methods and accuracy of iodine measurements in environmental samples. NIST traceable standards for 127I can be obtained through a number of commercial sources. The primary source of certified iodine radioisotope standards is the NIST. Standard reference materials for 129I (SRM 4401LZ, 30 MBq [0.8 mCi]) and 131I (SRM 4949C, 17 kBq [0.45 µCi]) are available from NIST. SRMs are also available for 127I measurements, including
EPA 2001b 40CFR415.432 Drug products containing certain active ingredients offered over-the counter for certain uses Drugs; recommended warning and caution statements—iodine and iodides (oral) Food additives permitted for direct addition to food for human consumption (as potassium iodide) Total amount for foods labeled without reference to age or physiological state Food additives permitted for direct addition to food for human consumption (as potassium iodide) Infants Children under 4 years of age Adults and children 4 or more years of age Pregnant or lactating women Food labelingCRDI Digestive aid and weight control drug product If a skin rash appears, discontinue use and consult physician
FDA 2000d 21CFR178.1010 (b)(40) NutrientsCminimum amount per 100 kilocalories Nutrition labeling of dietary supplements Nutritional quality guidelines RDIa Amount per 100 caloriesb Trace minerals added to animal feedsCcalcium iodate, calcium iodobehenate, cuprous iodide, 3,5-diiodosalicylic acid, ethylenediamine dihydroiodide, potassium iodate, potassium iodide, sodium iodate, sodium iodide, and thymol iodide d. Other
BNA 2001h HSDB 2001 BNA 2001h No data Hazardous substance list Toxic substance in the workplace Oil and hazardous material list Worker and Community Right-to Know ActChazardous substance list
BNA 2001h BNA 2001h BNA 2001h BNA 2001h RDI for adults and children 4 or more years of age 100 calories, based on 2,000 calorie intake as a daily standard
USNRC 2001a 10CFR20, Appendix B FDA 1998 Not more than 2.2 million electron volts
FDA 2000h 21CFR179.21 Diagnosis of thyroid functions; thyroid scans; treatment of hyper-thyroidism and/or cardiac dysfunction; treatment of thyroid carcinoma
DOE 2001b 10CFR835, Appendix A IODINE 8. REGULATIONS AND ADVISORIES Table 8-2. Regulations and Guidelines Applicable to Radioactive Iodine Agency
USNRC 2001c 10CFR71, Appendix A Standards for protection against radiation; quantities of licensed material requiring labeling (µCi) 120m
BNA 2001h BNA 2001h BNA 2001h IODINE 8. REGULATIONS AND ADVISORIES Table 8-2. Regulations and Guidelines Applicable to Radioactive Iodine
BNA 2001h 0.01 0.01 1,000 0.001 0.01 The limits apply to the sum of the relevant doses from external exposure in the specified period and the 50-year committed dose (to age 70 years for children) from intakes in the same period. With the further provision that the effective dose should not exceed 50 mSv in any single year. Additional restrictions apply to the occupational exposure of pregnant women. The limitation on the effective dose provides sufficient protection for the skin against stochastic effects. An additional limit is needed for localized exposures in order to prevent deterministic effects. In special circumstances, a higher value of effective dose could be allowed in a single year, provided that the average over 5 years does not exceed 1.0 mSv per year.
Abbott A, Barker S. 1996. Chernobyl damage 'underestimated'. Nature 380:658.
Abdel-Nabi H, Ortman JA. 1983. Radiobiological effects of 131I and 125I on the DNA of the rat thyroid: I. Comparative study with emphasis on the post radiation hypothyroidism occurrence. Radiat Res 93:525-533. *Abdullah ME, Said SA. 1981. Release and organ distribution of 125I from povidone-iodine under the influence of certain additives. Arzneim Forsch 31(1):59-61.