Technical Development Document for the Final Effluent Limitations Guidelines and Standards for the Meat and Poultry Products Point Source Category [DCN MP01102]
Other documents for the same rulemaking (all, by stage)
References: 96 extracted, 0 linked to papers
Christensen, H. 1996, December. Looking at the basics of the “hidden industry.” <http://www.mtgplace.com/articles/p699.asp>. (DCN 00120)
Lehmann, L. 2001, February. Glancing back: Changes in technology over the last 30 years. Render: The National Magazine of Rendering. <http://www.rendermagazine.com/February 2001/GlancingBack.html>. (DCN 00121)
Mead, G.C., ed. 1989. Processing of Poultry. Elsevier Science Publishing Co., Inc., New York,
Prokop, W. 1985. Rendering Systems for Processing Animal By-product Materials. Papers From the Symposium on Animal Fats Presented at the 74th AOCS Annual Meeting held in
Chicago, Illinois, May 8–12, 1983. Journal of the American Oil Chemists’ Society 62(4):805–811. (DCN 00124)
Sams, A.R., ed. 2001. Poultry Meat Processing. CRC Press, Boca Raton, FL. (DCN 00108 and 00109)
Stadelman, W.J., et al. 1988. Egg and Poultry-Meat Processing. Ellis Horwood Ltd., New York,
NY. (DCN 00111) Thorne, J. 2001. Personal communication. (DCN 10028)
USDA (U.S. Department of Agriculture). 1997. Agricultural Transportation Handbook. <http://www.ams.usda.gov/tmd/export/index.htm>. (DCN 00239) 4-68 Section 4. Meat and Poultry Products Overview
USDA (U.S. Department of Agriculture). 2001. Livestock Slaughter 2000 Summary. Mt An 1-21 (01a). U.S. Department of Agricultural, National Agricultural Statistics Service,
Washington, DC. (DCN 00183) USDA FSIS (U.S. Department of Agriculture) Food Safety Inspection Service)1986, February 26. Guidelines for specified cuts of poultry. <http://www.fsis.usda.gov/oppde/rdad/fsisdirectives/7110%2D1.pdf>. (DCN 00247)
USDA (U.S. Department of Agriculture). 1974. Development Document for Proposed Effluent Limitations Guidelines and New Source Performance Standards for the Processor Segment of the Meat Products Point Source Category. EPA/440/1-74/031. U.S. Environmental Protection Agency, Washington, DC. (DCN 00186)
USDA (U.S. Department of Agriculture). 1975. Development Document for Proposed Effluent Limitations Guidelines and New Source Performance Standards for the Poultry Segment of the Meat Product and Rendering Process Point Source Category. EPA/440/1-75/031b. U.S. Environmental Protection Agency, Washington, DC. (DCN 00140)
USDA (U.S. Department of Agriculture). 1995. Emission Factor Documentation for AP-42 Section 9.5.3: Meat Rendering Plants Final Report. EPA Contract No. 68-D2-0159. U.S. Environmental Protection Agency, Washington, DC. (DCN 00125)
USDA (U.S. Department of Agriculture). 1997. Emission Factor Documentation for AP-42 Section 9.5.1: Meat Packing Plants. U.S. Environmental Protection Agency, Washington,
DC. (DCN 00112) Wilson, A. 1998. Wilson’s Practical Meat Inspection. 6th ed. Blackwell Science, Ltd, Malden,
MA. (DCN 00106 and 00107) Warriss, P.D. 2000. Meat Science: An Introductory Text. CABI Publishing, New York, NY. (DCN 00103, 00104, and 00105) 4-69
SECTION 5 SUBCATEGORIZATION This section presents the subcategorization for the final rule for the meat and poultry products (MPP) effluent limitations guidelines (ELGs). Section 5.1 introduces EPA’s subcategorization criteria. Section 5.2 describes each subcategory in detail and discusses the differences between the existing subcategorization and the subcategorization for the final rule. The final subcategorization is the same as that proposed in the February 25, 2002, revisions to 40
USEPA (U.S. Environmental Protection Agency). 1974. Development Document for Effluent Limitations Guidelines and New Source Performance Standards—Red Meat Processing Segments of the Meat Products Point Source Category. EPA-440/1-74-012a. U.S. Environmental Protection Agency, Office of Air and Water Programs, Effluent Guidelines Division, Washington, DC. (DCN 00162)
USEPA (U.S. Environmental Protection Agency). 1975. Development Document for Proposed Effluent Limitation Guidelines and New Source Performance Standards for the Poultry Processing Point Source Category. EPA-440/1-75-031b. U.S. Environmental Protection
Joseph, Michigan. (DCN 00160) American Public Health Association. 1995. Standard Methods for the Examination of Water and
Wastewater, M.A.H. Franson, ed. Washington, DC (DCN 00196) Beefland International, Inc. 1971. Elimination of Water Pollution by Packinghouse Animal Paunch and Blood. Final Report Project 12060 FDS. U.S. Environmental Protection
Agency, Washington, Hansen, C.L., and G.T. West. 1992. Anaerobic digestion of rendering waste in an upflow anaerobic sludge blanket digestor. Bioresource Technology 41:181-185. (DCN 00126)
Johns, M.R. 1995. Developments in wastewater treatment in the meat processing industry: A review. Bioresource Technology 54:203-216. (DCN 00128) 6-20 Section 6. Wastewater Characterization
Metzner, G., and U. Temper. 1990. Operation and optimization of a full-scale fixed-bed reactor for anaerobic digestion of animal rendering wastewater. Water Science Technology 22 (½): 373-384. (DCN 00127)
National Rendering Association. 2000. Communication with Engineering and Analysis Division of USEPA, July 2000. (DCN 00122)
USEPA (U.S. Environmental Protection Agency). 1974. Development Document for Effluent Limitation Guidelines and New Source Performance Standards for the Red Meat Segment of the Meat Product and Rendering Processing Point Source Category. EPA-440/1-74012a. Effluent Guidelines Division, Office of Air and Water Programs, Washington, DC. (DCN 00162)
USEPA (U.S. Environmental Protection Agency). 1975. Development Document for Effluent Limitation Guidelines and New Source Performance Standards for the Poultry Segment of the Meat Product and Rendering Processing Point Source Category. EPA-440/1-75031b. Effluent Guidelines Division, Office of Water and Hazardous Materials,
APHA (American Public Health Association). 1995. Standard Methods for the Examination of Water and Wastewater, 19th, American Public Health Association, Washington, DC.
Aiello, S.E. ed. 1998. The Merck Veterinary Manual, 8th ed. Merck and Company, Inc., Whitehouse Station, New Jersey. 7-26
DAF is used extensively in the primary treatment of MPP wastewaters to remove suspended solids. The principal advantage of DAF over gravity settling is its ability to remove very small or light particles (including grease) more completely and in a shorter time. Once particles reach the surface, they are removed by skimming (Metcalf and Eddy, 1991).
DAF units that use chemical addition to promote solids separation are rendered; however, the chemical bond between the organic matter and the polymers requires that the sludges be processed (rendered) at higher temperatures (127oC or 260 oF) and for longer retention times. Because the efficacy of aluminum and iron salts and organic polymers is pH-dependent, pH Section 8. Wastewater Treatment Technologies and Pollution Prevention Practices adjustment normally precedes the addition of these compounds to minimize chemical use (Ross and Valentine, 1992; USEPA, 1974, 1975).
NPDES permit at a minimum apply both primary and secondary treatment to generated wastewaters (see Table 8-1). The objective of secondary treatment is to reduce of BOD through the removal of the organic matter, primarily in the form of soluble organic compounds, that remains after primary treatment. Although secondary treatment of wastewater can be performed using a combination of physical and chemical unit processes, using biological processes has remained the preferred approach (Peavy, et al. 1986). Wastewater pollutant removal efficiencies of greater than 90 percent can be achieved with biological treatment (Kiepper, 2001). According to responses to the MPP detailed survey, common systems used for biological treatment of MPP wastewater include lagoons, activated sludge systems, extended aeration, oxidation ditches, and sequencing batch reactors. A sequence of anaerobic biological processes followed by aerobic biological processes is commonly employed by MPP facilities that use biological treatment.
Kiepper (2001) suggests that approximately 25 percent of U.S. poultry facilities use biological treatment systems consisting of an anaerobic lagoon followed by an activated sludge system. 8.2.1 Anaerobic Treatment Anaerobic wastewater treatment processes use the microbially mediated reduction of complex organic compounds to methane and carbon dioxide as the mechanism for reducing organic matter and BOD. Because methane and carbon dioxide are essentially insoluble in water, both desorb rapidly. This combination of gases, predominantly methane, is commonly referred to
Nielsen, 1996; Peavy et al., 1986). In the second step, the alcohols and short-chained volatile acids are reduced further to methane and carbon dioxide by a group of obligate anaerobic microorganisms referred to collectively as methanogens. The methanogens include a number of species of methane-forming bacteria with growth rates significantly lower than those of the facultative and anaerobic microorganisms responsible for the initial reduction of complex compounds into the substrates that are reduced to methane. The biogas produced by the microbial activity typically contains 30 to 40 percent carbon dioxide and 60 to 70 percent methane plus trace amounts of hydrogen sulfide and other gases (Metcalf and Eddy, 1991; Nielsen, 1996; Peavy, 1986; Clanton, 1997). Because of the negligible energy requirements of anaerobic wastewater treatment processes, these processes are particularly attractive for the treatment of high-strength wastewaters such as MPP wastewaters. Even though anaerobic processes are not capable of producing dischargeable effluents, they can significantly reduce the amount of energy required for subsequent aerobic treatment to produce dischargeable effluents (Metcalf and Eddy, 1991;
However, competing reactions and the effects of alkalinity, pH, trace elements, and ligands found in wastewater make bench-scale or full-scale tests necessary to determine dosage rates. Because of coagulation and flocculation, suspended solids are also removed with the precipitated phosphorus species. With the addition of aluminum and iron salts, the addition of a base to maintain a pH in the range of 5 to 7 to optimize the efficacy of phosphorus precipitation might be necessary, depending on the wastewater’s buffer capacity (Metcalf and Eddy, 1991; Reddy, 1998;
USEPA, 1987). When lime is used, it is usually calcium hydroxide (Ca(OH)2). Because a reaction with natural bicarbonate alkalinity forms CaCO3 as a precipitate, an increase to a pH of 10 or higher is necessary for the formation of Ca5(PO4)3(OH). After lime is used to precipitate phosphorus, recarbonation with carbon dioxide is necessary to lower pH (Metcalf and Eddy, 1991; Reddy, 1998; USEPA, 1987). When chemical addition is used for phosphorus removal, additional benefits are realized. Because of coagulation and flocculation, effluent BOD and suspended solids concentrations are also reduced, especially when chemical addition occurs after secondary clarification (Metcalf and
Eddy, 1991; Reddy, 1998; USEPA, 1987). 8.3.2 Residual Suspended Solids Removal Simple clarification after secondary wastewater treatment might not reduce the concentration of suspended solids to the level necessary to comply with concentration or mass discharge permit limits or both. Granular-medium filtration usually is used to achieve further 8-32 Section 8. Wastewater Treatment Technologies and Pollution Prevention Practices reductions in suspended solids concentrations. This practice also provides further reductions in
UV irradiation, whether at low or medium pressure, performs similarly in achieving a 4-log inactivation of Cryptosporidium (Stone and Brooks, 2001). UV irradiation in combination with ozonation can also be applied for the reuse of chiller water in poultry operations (Diaz and Law, 1997).
FSIS requirements. Measuring and regulating water pressure for carcass washing to ensure that the FSIS requirements are not being exceeded is another example of how water use can be reduced in MPP operations. Measuring and regulating small flows such as those from handwashing operations can also significantly reduce water use and wastewater volume. The daily cleanup and sanitation of processing facilities and equipment contributes substantially to water use and wastewater pollutant load and probably presents the greatest opportunity for reductions. Typically, both water use and wastewater pollutant load can be reduced substantially by initially “dry cleaning” processing areas and equipment to collect meat 8-48 Section 8. Wastewater Treatment Technologies and Pollution Prevention Practices scraps and other materials for disposal by rendering instead of the common practice of using water as a “broom.” Although subsequent screening before wastewater treatment provides for recovery of larger particles, fine particulate matter and soluble proteins, fats, and carbohydrates are not recovered and are manifested as an increased pollutant load to the wastewater treatment plant. Gelman et al. (1989) have shown that BOD in cleanup wastewater in poultry processing can be reduced from 20 to 50 percent by initially dry cleaning processing areas and equipment.
USDA FSIS guidelines do not preclude the multiple use and reuse of water in MPP facilities as practices to reduce potable water consumption and the discharge of treated wastewater. Although it is obvious that acceptable multiple use and reuse strategies must avoid contact with products intended for human consumption, a significant fraction of the water used in meat and poultry processing does not involve such contact. The multiple use of water most commonly occurs in poultry processing. Witherow et al. (1978) report that water conservation through multiple use in poultry processing is rewarded by savings in processing cost and reduced requirements for wastewater treatment. Examples include 8-49 Section 8. Wastewater Treatment Technologies and Pollution Prevention Practices using scalder overflow to flume feathers from mechanical de-feathering equipment and using chiller overflow to flume inedible viscera to screens for recovery before rendering. Combination
Banks, C.J. 1994. Anaerobic Digestion of Solid and High Nitrogen Content Fractions of Slaughterhouse Wastes, In Environmentally Responsible Food Processing, AIChE Symposium Series no. 90, 103–109. (DCN 100005)
Banks, C.J., and O.O. Adebowale. 1991. Review of Abattoir By-product Disposal options. In Proceedings of MLC Conference: Meat Strategies, Options for By-product Disposal, 26–27th March 1991, Birmingham, U.K., pp. 21–42. (DCN 00042)
Banks, C.J., and Z. Wang. 1999. Development of a two phase anaerobic digester for the treatment of mixed abattoir wastes. Water Science and Technology 40 (1). (DCN 10065) 8-54 Section 8. Wastewater Treatment Technologies and Pollution Prevention Practices
Berthouex, P.M., D.L. Grothman, D.O. Dencker, and Lawrence J.P. Scully. 1977, May. Characterization and In-Plant Reductions of Wastewater from Hog Slaughtering Operations. EPA-600/2-77-097. (DCN 10058)
Brooks, D.R., and G. Van Stone. 2001. UV experience in inactivating Cryptosporidium in surface water plants. WaterWorld, May 2001. PennWell Publishers. (DCN 10068)
Carawan, R.E. 1994. Overview of Water Recycling in Processing. In Proceedings 1994 National Poultry Waste Management Symposium, ed. P.H. Patterson and J.P. Blake, pp. 211–215. National Poultry Waste Management Symposium Committee, Auburn University, Alabama. (DCN 00198)
Carawan, R.E., and J.S. Clemens. 1994. Using Renovated Process Water at Hatfield Packing. In Proceedings 1994 National Poultry Waste Management Symposium, ed. P.H. Patterson and J.P. Blake, pp. 220–230. National Poultry Waste Management Symposium
Clanton, C.J. 1997. Alternative Waste Management Systems. Department of Agricultural
Cowan, J.A.C., F. Mactavish, C.J. Brouckaert, and E.P. Jacobs. 1992. Membrane treatment strategies for red meat abattoir effluents. Water Science and Technology 25 (10). (DCN 10066)