Russel et al. (2021) A novel bio-physical approach for perchlorate contaminated well water treatment. Journal Article.
Other documents for the same rulemaking (all, by stage)
References: 60 extracted, 0 linked to papers
Zilles, 2018) (Xie et al., 2018) Adsorption using Granular Activated Carbon Membrane filtration Reverse Osmosis Ultrafiltration Nanofiltration Electrodialysis Metal-based Catalytic Reduction, Electrochemical Reduction In-situ bioremediation Ex-situ bioremediation Maintenance of low pH and high pressure, generation of highly reactive species, extreme reaction conditions Repeated addition of electron donors, growth of Non-PRB, the release of metabolic by-products, etc. Cannot be applied in drinking water systems as it contains residual microbial load, metabolic by-products, and unused organics, the problem of public acceptance immobilized on matrices were employed for removing ClO4 ¯ in drinking water (Hutchison and Zilles, 2015). A comparison of prominent methods for treating ClO4 ¯ is presented in Table 1. Perchlorate remediation infield practices may require a combination of one or more approaches (hybrid processes) to achieve the desired product water quality, or to regenerate the resin/membrane, or to treat the reject (Srinivasan and Sorial, 2009; Ye et al., 2012). Different combinations of adsorption, ultrafiltration (UF), nanofiltration (NF) and reverse osmosis (RO) have been reported in the past for removing ClO4 ¯ and similar oxyanions in aqueous systems (Han et al., 2012; Xie et al., 2011; Yoon et al., 2009, 2005). Most of the studies reported cover the treatment of groundwater contaminated with ClO4 ¯ at sub ppm level.
Moreover, microbial processes were adopted in some of these studies mainly for regenerating the resin, or for treating the reject (Giblin et al., 2002; Lin et al., 2007). Ion exchange combined with resin regeneration through chemical reduction or bio-regeneration is reported in few cases (Kim and Choi, 2014; Li et al., 2020; Ebrahimi et al., 2017; Yang et al., 2020). Similarly, combined adsorption and microbial reduction, and integrated ion exchange membrane bioreactor were also reported for removing ClO4 ¯ in groundwater (Brown et al., 2002; Fox et al., 2016; Song et al., 2015). Unlike the studies reported previously, a novel approach is practiced in this study where ClO4 ¯ was initially treated in a bioreactor, followed by a series of MF and RO systems for attaining safe limits of ClO4 ¯ in the treated water. Furthermore, the treatment of open well water highly contaminated with ClO4 ¯ is targeted in this study.
Therefore, this study investigated in pilot-scale, a novel approach for removing field relevant concentration of ClO4 ¯ in well water. Moreover, practical solutions for the fouling associated with the MF and RO membranes used in the process were also studied. The level of ClO4 ¯ selected in this study was similar to the average ClO4 ¯ concentration observed in well water at a contaminated site (Keezhmad, Kerala, India). (Xie et al., 2018; Huq et al., 2007) (Urbansky and
Schock, 1999) (Urbansky, 1998; Yang et al., 2016) (Hatzinger et al., 2006; Stroo et al., 2009) (Srinivasan and
Similarly, poor bio-regeneration capacity (84.9% in 5 days) of a surfacemodified bio-sorbent for removing ClO4 ¯ , and further the requirement of sterilization of resin before the next adsorption step was also reported (Ren et al., 2017). Increased fouling after bio-regeneration of the membrane due to the accumulation of soluble microbial products and extra polymeric substances during the bio-regeneration step was also reported in this study. The removal of ClO4 ¯ in groundwater through a combined electrodialysis (EDR) and the RO method was reported recently (Yang et al., 2020). Perchlorate at an initial 10.5 mg/L was removed to a non-detectable limit through this approach. However, at higher initial ClO4 ¯ concentration, a lower removal through EDR was observed in this study. Compared with the different approaches reported, particularly for water contaminated with higher levels of ClO4 ¯ , the method reported in this study would be a better option. Since most of the ClO4 ¯ is removed in the AFBR, a small capacity RO membrane would be sufficient for the final treatment. This will bring also down the operational cost of the entire treatment system. Fig. 4. Perchlorate removal by RO membrane for different inlet ClO4 ¯ concentration at a flow rate of 40 l/h and 50 psi. decline in ClO4 ¯ removal at higher concentrations could be due to the shock loading effect, or insufficient ClO4 ¯ reducing biomass level in the
RO membrane used was 2 mg/L, whereas ClO4 ¯ concentration in the well water was 15 mg/L. To overcome this difficulty, the AFBR unit was introduced prior to the RO unit. The AFBR removed ~97% of the initial ClO4 ¯ concentration, the residual ClO4 ¯ (0.4 ± 0.35 mg/L) was removed by the RO unit. However, a decreased flux and low ClO4 ¯ rejection were observed at this stage due to membrane fouling. The high bacterial cell count (~107 CFU/mL) in the AFBR treated water can easily clog the membrane. To decrease fouling, the ceramic MF unit as a pretreatment to RO membrane was introduced. The MF passed water had only 200 ± 60 CFU/mL. Bacterial cells were not completely removed in the MF unit used, probably due to the large pore size (1.5 𝜇m) of the ceramic J.G. Russel, V. Thulasiraman, R.R. Nair et al. Environmental Advances 4 (2021) 100058 Table 2. Concentration of perchlorate and other water quality parameters in feed water and at different stages of the combined treatment system at optimized working conditions. Contaminant Feed water
Akhtar, A., Senthilmurugan, S., Mohanty, K., Sundar, R., Unnikrishnan, R., Hareesh, U.S., 2020. Sugarcane juice clarification by lanthanum phosphate nanofibril coated ceramic ultrafiltration membrane: PPO removal in absence of lime pre-treatment, fouling and cleaning studies. Sep. Purif. Technol. 249, 117157.
Anupama, V.N., Kannan, K., Prajeesh, P.V.G., Rugmini, S., Krishnakumar, B., 2012. Perchlorate, chlorate and bromate in water samples from the South-West coast of India. Water Sci. Technol. Water Supply 12, 595–603.
Bagheri, M., Mirbagheri, S.A., 2018. Critical review of fouling mitigation strategies in membrane bioreactors treating water and wastewater. Bioresour. Technol. 258, 318–334.
Batista, J.R., Gingras, T.M., Vieira, A.R., 2002. Combining Ion-exchange (IX) technology and biological reduction for perchlorate removal. Remediat. J. 13, 21–38.
Brown, J.C., Snoeyink, V.L., Kirisits, M.J., 2002. Abiotic and biotic perchlorate removal in an activated carbon filter. J. Am. Water Work. Assoc. 94, 70–79. Calderón, R., Palma, P., Arancibia-Miranda, N., Kim, U.J., Silva-Moreno, E., Kannan, K., 2020. Occurrence, distribution and dynamics of perchlorate in soil, water, fertilizers, vegetables and fruits and associated human exposure in Chile. Environ. Geochem. Health 1–9.
Cecconet, D., Callegari, A., Capodaglio, A.G., 2018. Bioelectrochemical systems for removal of selected metals and perchlorate from groundwater: a review. Energies 11, 2643.
Chang, H., Liang, H., Qu, F., Liu, B., Yu, H., Du, X., Li, G., Snyder, S.A., 2017. Hydraulic backwashing for low-pressure membranes in drinking water treatment: a review. J. Memb. Sci. 540, 362–380.
Ebrahimi, S., Xiao, Y., Roberts, D.J., Ion Exchange: Theory and Applications (2017), Pages 231-250., Bio-regeneration of resin: A novel method for increased sustainability of the ion exchange process (Book Chapter).
Farhan, Y.H., Hatzinger, P.B., 2009. Modeling the biodegradation kinetics of perchlorate in the presence of oxygen and nitrate as competing electron acceptors. Bioremediat. J. 13, 65–78.
Fox, S., Bruner, T., Oren, Y., Gilron, J., Ronen, Z., 2016. Concurrent microbial reduction of high concentrations of nitrate and perchlorate in an ion exchange membrane bioreactor. Biotechnology and bioengineering 113 (9), 1881–1891.
Giblin, T., Losi, M.E., Hosangadi, V., Frankenberger, W.T., 2002. Bacterial perchlorate reduction in simulated reverse osmosis rejectate. Bioremediat. J. 6, 105–111.
Han, J., Kong, C., Heo, J., Yoon, Y., Lee, H., Her, N., 2012. Removal of perchlorate using reverse osmosis and nanofiltration membranes. Environ. Eng. Res. 17, 185–190.
Hatzinger, P.B., Diebold, J., Yates, C.A., Cramer, R.J., 2006. Field demonstration of in situ perchlorate bioremediation in groundwater. In: Perchlorate. Springer, pp. 311–341.
Huq, H.P., Yang, J.S., Yang, J.W., 2007. Removal of perchlorate from groundwater by the polyelectolyte-enhanced ultrafiltration process. Desalination 204, 335–343. Conclusions In the present study, initial microbiological followed by a combination of MF and RO membranes in series was effective for treating well water contaminated with higher levels of ClO4 ¯ (15 mg/L). The anaerobic biotreatment reduced ~97% of the ClO4 ¯ in well water into non-toxic chloride and oxygen. The subsequent MF and RO membrane removed the residual ClO4 ¯ level to <10 μg/L. This study also demonstrates the effectiveness of cost-effective, and environment-friendly approaches like backwashing and forward flushing with pure water to manage fouling associated with the MF and RO membranes. The ClO4 ¯ present in the rejects and wash water from the membranes were also treated so that there is no need for secondary treatment. This kind of treatment system will be useful for addressing localized, higher ClO4 ¯ contamination of J.G. Russel, V. Thulasiraman, R.R. Nair et al. Environmental Advances 4 (2021) 100058
Hutchison, J.M., Zilles, J.L., 2018. Biocatalytic removal of perchlorate and nitrate in ion-exchange waste brine. Environ. Sci. Water Res. Technol. 4, 1181–1189.
Hutchison, J.M., Zilles, J.L., 2015. Biocatalytic perchlorate reduction: kinetics and effects of groundwater characteristics. Environ. Sci. Water Res. Technol. 1, 913–921.
Isobe, T., Ogawa, S.P., Sugimoto, R., Ramu, K., Sudaryanto, A., Malarvannan, G., Devanathan, G., Ramaswamy, B.R., Munuswamy, N., Ganesh, D.S., 2013. Perchlorate contamination of groundwater from fireworks manufacturing area in South India. Environ. Monit. Assess. 185, 5627–5637.
Kannan, K., Praamsma, M.L., Oldi, J.F., Kunisue, T., Sinha, R.K., 2009. Occurrence of perchlorate in drinking water, groundwater, surface water and human saliva from India. Chemosphere 76, 22–26. doi:10.1016/j.chemosphere.2009.02.054.
Keezhmad Project Report, (2015), Assessment report on perchlorate pollution by technical expert committee as per order no. ML/22723/2014 dt 19.06.2014.
Kengen, S.W.M., Rikken, G.B., Hagen, W.R., Van Ginkel, C.G., Stams, A.J.M., 1999. Purification and characterization of (per) chlorate reductase from the chlorate-respiring strain GR-1. J. Bacteriol. 181, 6706–6711.
Kim, K., Logan, B.E., 2001. Microbial reduction of perchlorate in pure and mixed culture packed-bed bioreactors. Water Res. 35, 3071–3076.
Kim, Y.N., Choi, M., 2014. Synergistic integration of ion-exchange and catalytic reduction for complete decomposition of perchlorate in waste water. Environ. Sci. Technol. 48, 7503–7510.
Lehman, S.G., Badruzzaman, M., Adham, S., Roberts, D.J., Clifford, D.A., 2008. Perchlorate and nitrate treatment by ion exchange integrated with biological brine treatment. Water Res. 42, 969–976.
Li, T., Ren, Y., Zhai, S., Zhang, Weiming, Zhang, Wenbin, Hua, M., Lv, L., Pan, B., 2020. Integrating cationic metal-organic frameworks with ultrafiltration membrane for selective removal of perchlorate from Water. J. Hazard. Mater. 381, 120961.
Liao, Z., Cao, D., Gao, Z., Zhang, S., 2020. Occurrence of perchlorate in processed foods manufactured in China. Food Control 107, 106813.
Lin, X., Roberts, D.J., Hiremath, T., Clifford, D.A., Gillogly, T., Lehman, S.G., 2007. Divalent cation addition (Ca2+ or Mg2+ ) stabilizes biological treatment of perchlorate and nitrate in ion-exchange spent brine. Environ. Eng. Sci. 24, 725–735.
Pereira, B., Bhaskaran, K., 2017. Spatio-temporal distribution of perchlorate and its toxicity in Hydrilla verticillata. Ecotoxicol. Environ. Saf. 144, 490–497.
Nguyen, T., Roddick, F.A., Fan, L., 2012. Biofouling of water treatment membranes: A review of the underlying causes, monitoring techniques and control measures. Membranes 2, 804–840. doi:10.3390/membranes2040804, (Basel).
Pan, J., Gao, B., Song, W., Xu, X., Jin, B., Yue, Q., 2019. Column adsorption and regeneration study of magnetic biopolymer resin for perchlorate removal in presence of nitrate and phosphate. J. Clean. Prod. 213, 762–775.
Qi, Y., Xu, X., Qi, C., Fei, X., 2017. Bio-regeneration of spent Fe3 O4 laden quaternary-ammonium shaddock peel after perchlorate capture: considering the oxygen, coexisting anions, bio-fouling and indirect bio-regeneration. Chem. Eng. J. 316, 204–213.
Ren, Z., Xu, X., Gao, B., Li, Y., Kong, J., Shang, Y., Song, W., Zhang, Q., 2017. Capture of perchlorate by a surface-modified bio-sorbent and its bio-regeneration properties: adsorption, computations and biofouling. Chemosphere 185, 152–161.
Rikken, G.B., Kroon, A.G.M., Van Ginkel, C.G., 1996. Transformation of (per) chlorate into chloride by a newly isolated bacterium: reduction and dismutation. Appl. Microbiol. Biotechnol. 45, 420–426.
Sanyal, O., Sommerfeld, A.N., Lee, I., 2015. Design of ultrathin nanostructured polyelectrolyte-based membranes with high perchlorate rejection and high permeability. Sep. Purif. Technol. 145, 113–119.
Shao, S., Wang, Y., Shi, D., Zhang, X., Tang, C.Y., Liu, Z., Li, J., 2018. Biofouling in ultrafiltration process for drinking water treatment and its control by chlorinated-water and pure water backwashing. Sci. Total Environ. 644, 306–314.
Sharbatmaleki, M., Batista, J.R., 2012. Multi-cycle bioregeneration of spent perchlorate– containing macroporous selective anion-exchange resin. Water Res. 46, 21–32.
Sharbatmaleki, M., Unz, R.F., Batista, J.R., 2015. Potential mechanisms for bioregeneration of perchlorate-containing ion-exchange resin. Water Res. 75, 1–10.
Song, W., Gao, B., Xu, X., Zhang, T., Liu, C., Tan, X., Sun, S., Yue, Q., 2015. Treatment of dissolved perchlorate by adsorption–microbial reduction. Chem. Eng. J. 279, 522–529.
Srinivasan, R., Sorial, G.A., 2009. Treatment of perchlorate in drinking water: a critical review. Sep. Purif. Technol. 69, 7–21.
Stetson, S.J., Wanty, R.B., Helsel, D.R., Kalkhoff, S.J., Macalady, D.L., 2006. Stability of low levels of perchlorate in drinking water and natural water samples. Anal. Chim. Acta 567, 108–113.
Stroo, H.F., Loehr, R.C., Ward, C.H., 2009. situ bioremediation of perchlorate in groundwater: an overview. In: In Situ Bioremediation of Perchlorate in Groundwater. Springer, pp. 1–13.
Urbansky, E.T., 2002. Perchlorate as an environmental contaminant. Environ. Sci. Pollut. Res. 9, 187–192. doi:10.1007/BF02987487.
Urbansky, E.T., 1998. Perchlorate chemistry: implications for analysis and remediation. Bioremediat. J. 2, 81–95.
Urbansky, E.T., Schock, M.R., 1999. Issues in managing the risks associated with perchlorate in drinking water. J. Environ. Manag. 56, 79–95. Vijaya Nadaraja, A., Gangadharan Puthiya Veetil, P., Bhaskaran, K., 2013. Perchlorate reduction by an isolated S erratia marcescens strain under high salt and extreme p H.
FEMS Microbiol. Lett. 339, 117–121. Wolff, J., 1998. Perchlorate and the thyroid gland. Pharmacol. Rev. 50, 89–106.