Fourth National Report on Human Exposure to Environmental Chemicals [DCN SE03028]
Other documents for the same rulemaking
References: 1,319 extracted, 0 linked to papers
BC. Analysis of perchlorate in human urine using ion chromatography and electrospray tandem mass spectrometry. Anal Chem 2005;77(8):2475-2481. Perfluorochemicals
Kuklenyik Z, Needham LL, Calafat AM. Measurement of 18 perfluorinated organic acids and amides in human serum using on-line solid-phase extraction. Anal Chem 2005;77:6085-6091. Phthalates
Needham LL, et al. Quantitative detection of eight phthalate metabolites in human urine using HPLC-APCI-MS/MS. Anal Chem 2000;72:4127-4134.
Barr DB, et al. Improved quantitative detection of 11 urinary phthalate metabolites in humans using liquid chromatography-atmospheric pressure chemical ionization tandem mass spectrometry. J Chromatog B 2003;789:393404.
Samandar E, et al. Analysis of human urine for 15 phthalate metabolites using automated solid-phase extraction. J Chromatog B 2004;805:161-167. Phytoestrogens
HPLC-MS/MS method for the measurement of seven phytoestrogens in human serum and urine. J Expo Anal Environ Epidemiol 2000;10:799-807.
Kuklenyik Z, Ye X, Reich JA, Needham LL, Calafat AM. Automated on-line and off-line solid phase extraction methods for measuring isoflavones and lignans in urine. J Chromatogr Sci 2004; 42:495-500.
EE III, Patterson DG. Semiautomated high-throughput extraction and cleanup method for the measurement of polybrominated diphenyl ethers, polybrominated biphenyls, and polychlorinated biphenyls in human serum. Anal Chem 2004;76:1921-1927. Polychlorinated Biphenyls, Polychlorinated Dibenzo-pdioxins, Dibenzofurans
Sandau CD, et al. New high-resolution mass spectrometric approach for the measurement of polychlorinated biphenyls and organochlorine pesticides in human serum. J Chromatog B 2003;794:137-148. Patterson DG Jr., Alexander LR, Turner WE, Isaacs SG,
Needham LL. The development and application of a high resolution mass spectrometry method for measuring polychlorinated dibenzo-p-dioxins and dibenzofurans in serum. In: Clement RE, Sui KM, Hill HH Jr., eds. Instrumentation for trace organic monitoring. Chelsea, MI: Lewis Publishers; 1990. pp. 119-53. Patterson DG Jr., Hampton L, Lapeza CR Jr., Belser
WT, Green V, Alexander L, et al. High resolution gas chromatographic/high resolution mass spectrometric analysis of human serum on a whole weight and lipid basis for 2,3,7,8 TCDD. Anal Chem 1987;59:2000-2005.
DiPietro ES, McClure PC, et al. Levels in the U.S. population of those persistent organic pollutants (2003-2004) included in the Stockholm Convention or in other Long-Range Tran boundary Air Pollution Agreements. Environ Sci Technol 2009;43(4):1211-1218.
PCDFs, and coplanar PCBs. Organohalogen Compounds 1994;19:31-35.
PCB congeners, and persistent pesticides from the same serum sample. Organohalogen Compounds 1997;31:26-31. Polybrominated Diphenyl Ethers and 2,2’,4,4’,5,5’-Hexabromobiphenyl Polycyclic Aromatic Hydrocarbons Sjödin A, Jones RS, Lapeza CR, Focant J-F, McGahee
Appendix C. References for Biomonitoring Analytical Methods polycyclic aromatic hydrocarbons (PAH) and diesel exhaust by measurement of urinary biomarkers. Epidemiology 2004;15(4):S75.
DG, Sandau CD. Automated solid-phase extraction method for measuring urinary polycyclic aromatic hydrocarbon metabolites in human biomonitoring using isotope-dilution gas chromatography high-resolution mass spectrometry. J Chromatog B 2006;835:47-54.
Smith CJ, Huang WL, Walcott CJ, Turner WE, Grainger J, Patterson DG Jr. Quantification of monohydroxy-PAH metabolites in urine by solid-phase extraction with isotope dilution GC-HRMS. Anal Bioanal Chem 2002;372:216220. Volatile Organic Compounds
Morrow J.C, Chambers D.M, et al. Quantification of 31 volatile organic compounds in whole blood using solidphase microextraction and gas chromatography-mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2006;832: 292-301. Fourth National Report on Human Exposure to Environmental Chemicals Fourth National Report on Human Exposure to Environmental Chemicals Chemical Cotinine N,N-Diethyl-meta -toluamide (DEET) Disinfection By-Products (Trihalomethanes) Bromodichloromethane Dibromochloromethane (Chlorodibromomethane) Tribromomethane (Bromoform) Trichloromethane (Chloroform) Glycidamide Acrylamide Adducts Acrylamide pg/mL pg/mL pg/mL pg/mL blood blood blood blood blood serum urine Units pmol/g hemoglobin pmol/g hemoglobin ng/mL µg/L blood Matrix 0.05 0.449 0.233 0.271 0.596 2.37 0.05 0.62 0.62 2.11 0.015 1999-2000 2001-2002 2003-2004 Reference: Taylor JK. Quality Assurance of Chemical Measurements. Chelsea (MI): Lewis Publishing. 1987. As analytical methods improve, LODs will often change. For this reason, LOD results are reported by survey periods (e.g., 1999-2000, 20012002, 2003-2004). For chemicals with sample-specific LODs, we report in the table the maximum LOD among the samples analyzed. In general, the average
LOD for these samples is about 40-50% of the maximum LOD. If a geometric mean or percentile estimate is less than the maximum LOD, it is noted in the results tables, and we do not report a number for that estimate. This conservative approach is to assure high confidence in all number reported in the results tables. The analytical limit of detection (LOD) for each of the different chemical measurements is presented in the table below. The LOD is the level at which the measurement has a 95% probability of being greater than zero (Taylor, 1987). For most chemicals, the LOD is constant for each sample analyzed. However, for dioxins, furans, PCBs, organochlorine insecticides, and some other pesticides, each individual sample has its own LOD. These analyses have an individual LOD for each sample, mostly because the sample volume available for analysis differed for each sample. A higher sample volume results in a lower LOD and a better ability to detect low levels.