Policy Replication

Damage Case Compendium Technical Support Document, Volume IIa: Potential Damage Cases - DCN SE04459

Docket document2015-11-03 · EPA · report · EPA-HQ-OW-2009-0819-5768
RIN 2040-AG41, RIN 2040-AF77, RIN 2040-AF14, RIN 2040-AG54, RIN 2040-AG48, RIN 2040-AG23, RIN 2040-AF76 · Docket EPA-HQ-OW-2009-0819

Other documents for the same rulemaking

2009-10-29 Docket documentSteam Electric Power Generating Point Source Category: Final Detailed Study Report [EPA 821-R-09-008] [DCN 00003]
2009-10-29 Docket documentSupporting Statement for the Draft Questionnaire for the Steam Electric Power Generating Effluent Guidelines Information Collection Request [DCN 00001]
2009-10-29 Docket documentDraft Questionnaire for the Steam Electric Power Generating Effluent Guidelines [DCN 00002]
2009-10-29 Docket documentAgency Information Collection Activities; Proposed Collection; Comment Request; Proposed Information Collection Request for the Steam Electric Power Generating Effluent Guidelines; EPA ICR No. 2368.01, OMB Control No. 2040-NEW
2009-12-30 Docket documentLetter to Peter Silva, USEPA from Elizabeth E. Aldridge, Hunton and Williams L.L.P on behalf of the Utility Water Act Group (UWAG) [DCN SE00112]
2009-12-31 Docket documentLetter to Elizabeth E. Aldridge, Hunton and Williams, LLP from Peter S. Silva, Assistant Administrator, USEPA [DCN SE00113]
2010-03-09 Docket documentLetter to Ron Jordan, USEPA/Engineering and Analysis Division regarding USEPA Draft Steam Effluent Guidelines Questionnaire (November 17, 2009) [DCN SE00195]
2010-03-09 Docket documentLetter to Ron Jordan, USEPA/Engineering and Analysis Division regarding Comments on USEPA (February 1, 2010) [DCN SE00197]
2010-03-09 Docket documentEmail to Ron Jordan, USEPA/Engineering and Analysis Division regarding Steam Electric Power Generating EG - Proposed ICR Follow up Materials (January 20, 2010) [DCN SE00198]
2010-03-09 Docket documentLetter to Ron Jordan, USEPA/Engineering and Analysis Division regarding Ash Handling Systems Cost List (February 18, 2010) [DCN SE00200]
2010-03-09 Docket documentSupporting Statement for the Draft Questionnaire for the Steam Electric Power Generating Effluent Guidelines Information Collection Request (Part A) [DCN SE00205]
2010-03-09 Docket documentEmail to Ron Jordan, USEPA (February 19, 2010) [DCN SE00191]
2010-03-09 Docket documentEmail to Defenders of Wildlife, Sierra Club, Environmental Integrity, Earth Justice, and Natural Resources Defense Council [DCN SE00192]
2010-03-09 Docket documentEmail to Utility Water Act Group, American Public Power Association, and Edison Electric Institute [DCN SE00193]
2010-03-09 Docket documentEmail to Ron Jordan, USEPA dated February 3, 2010 [DCN SE00199]
2010-03-09 Docket documentAgenda and Example Flue Gas Desulfurization (FGD) Diagram for Discussion Between USEPA and Utility Water Act Group (UWAG) [DCN SE00201]
2010-03-09 Docket documentMemorandum to Steam Electric Record [DCN SE00204]
2010-03-09 Docket documentRon Jordan and Jezebele Alicea (February 25, 2010) [DCN SE00203]
2010-03-09 Docket documentEmail to Ron Jordan, US EPA (January 22, 2010) [DCN SE00190]
2010-03-09 Docket documentMemorandum to Ron Jordan, USEPA [DCN SE00206]
2010-03-09 Docket documentAgency Information Collection Activities; Submission to OMB for Review and Approval; Comment Request; Questionnaire for Steam Electric Power Generating Effluent Guidelines (NEW); EPA ICR No. 2368.01, OMB Control No. 2040-NEW
2013-06-07 Regulatory impact analysisRegulatory Impact Analysis For EPA’s Proposed RCRA Regulation Of Coal Combustion Residues (CCR) Generated by the Electric Utility Industry [DCN SE02969]
2013-06-07 Regulatory impact analysisTechnical Support Document: Calculating Benefit Per-Ton Estimates. Final Ozone NAAQS regulatory impact analysis [DCN SE03161]
2013-06-07 Regulatory impact analysisRegulatory Impact Analysis of the Clean Air Mercury Rule (EPA-452/R-05-003) [DCN SE03159]
2013-06-07 Regulatory impact analysisRegulatory Impact Analysis for the Industrial Boilers and Process Heaters NESHAP: Final Report (EPA-452/R-04-0020) [DCN SE03156]
2013-06-07 Regulatory impact analysisRegulatory Impact Analysis for the Proposed Effluent Limitations Guidelines and Standards for the Steam Electric Power Generating Point Source Category [DCN SE03170]
2013-06-07 Regulatory impact analysisFinal Regulatory Analysis: Control of Emissions from Nonroad Diesel Engines (EPA420-R-04-007) [DCN SE03157]
2013-06-07 Regulatory impact analysisQuality Assurance Project Plan (QAPP) for Economic Impact and Benefits Analysis for Steam Electric Rulemaking [DCN SE03376]
2013-06-07 Regulatory impact analysisList of Rulemaking Cost and Economic Impact Files: Steam Electric Effluent Guidelines Rulemaking [DCN SE03351]
2013-06-07 Docket documentEconomic Assessment of Damage Related to the Eagle Mine Facility [DCN SE03117]
2013-06-07 Docket documentRegulatory Impact Analysis for USEPA’s Proposed RCRA Regulation of Coal Combustion Residues (CCR) Generated by the Electric Utility Industry [DCN SE03168]
2013-06-07 Docket documentDocument submitted to initiate E.O. 12866 review - Steam Electric ELG NPRM FRN [DCN SE03884]
2013-06-07 Docket documentDocument submitted to conclude E.O. 12866 review - SteamElectricELG NPRM FRN - [DCN SE03958]
2013-06-07 Docket documentDocument of Changes Made During OMB Review Under E.O. 12866 - SteamElectric ELG NPRM FRN [DCN SE03972]
2013-06-07 Docket documentFishbase (version 07/2009) [DCN SE03047]
2013-06-07 Docket documentGuidance for Assessing Chemical Contaminant Data for Use in Fish Advisories, Volume 1 Fish Sampling Analysis, Third Edition [DCN SE01922]
2013-06-07 Docket documentDraft Human and Ecological Risk Assessment of Coal Combustion Wastes [DCN SE01834]
2013-06-07 Docket documentThe use of willingness-to-pay approaches in mammal conservation [DCN SE03191]
2013-06-07 Docket documentUsing the Basic Auto-validation Model to Assess the Effect of Environmental Quality on Texas Recreational Fishing Demand: Welfare Estimates [DCN SE03022]
2013-06-07 Docket documentNOAA National Marine Fisheries Service Southwest Regional Office, GIS Data [DCN SE03091]
2013-06-07 Docket documentSouthwest Fisheries Science Center Fisheries Biology Publications Database [DCN SE03134]
2013-06-07 Docket documentFinal report: Health Study to Assess the Human Health Effects of Mercury Exposure to Fish Consumed from the Everglades [DCN SE03152]
2013-06-07 Docket documentSTORET, EPA’s largest computerized environmental data system [DCN SE03160]
2013-06-07 Docket documentNational Recommended Water Quality Criteria [DCN SE03175]
2013-06-07 Docket documentNorth Florida Ecological Services Office Loggerhead Sea Turtle Caretta caretta [DCN SE03180]
2013-06-07 Docket documentNew Hampshire Clean Air Project Final Report Prepared for New Hampshire Public Utilities Commission [DCN SE02011]
2013-06-07 Docket documentFinal Site Visit Notes: Dominion Resources' Chesterfield Power Station [DCN SE00076]
2013-06-07 Docket documentMay 2011 National Industry-Specific Occupational Employment and Wages Estimates NAICS 221100 Electric Power Generation, Transmission and Distribution [DCN SE03221]
2013-06-07 Docket documentState Tax Rate Comparisons [DCN SE03229]
2013-06-07 Docket documentPopulation Estimates. National Population Datasets [DCN SE03241]
2013-06-07 Docket documentSustainable Financing Strategies [DCN SE03257]
2013-06-07 Docket documentAnnual Energy Outlook 2011 (AEO2011) [DCN SE03249]
2013-06-07 Docket documentEPA’s IPM Base Case v. 4.10 [DCN SE03265]
2013-06-07 Docket documentPlant Comments on Draft Kinder Morgan (Jackson Power Facility) Site Visit Notes [DCN SE00600]
2013-06-07 Docket documentFinal Engineering Site Visit Report for Georgia Power's Plant Yates [DCN SE02053]
2013-06-07 Docket documentNon CBI - Final Site Visit Notes: Appalachian Power Company's Mountaineer Plant [DCN SE02071]
2013-06-07 Docket documentNotes from Site Visit at the AES Cayuga Generation Plant on May 21, 2007 [DCN SE02061]
2013-06-07 Docket documentFinal Site Visit Notes: Tennessee Valley Authority’s Paradise Fossil Plant [DCN SE02101]
2013-06-07 Docket documentUWAG Draft Sampling Instructions for USEPA Collision Cell ICP-MS Methods Study [DCN SE00491]
2013-06-07 Docket documentPlant Comments to Belews Creek Sampling Episode Report, Revised SER [DCN SE01377]

References: 514 extracted, 0 linked to papers

Page 8Download these results: CSV · JSON
The W.J. Neal Plant was located on several tens of feet-thick Wisconsin-age glacial till area south of the Lake Souris glaciated plains. Part of the Coleharbor Group,450 it comprises till, sand, gravel, silt, and clay.451 These deposits overlie sandstone, siltstone, claystone, shale, and lignite of the Tertiary-age Fort Union Formation. The unconfined Voltaire aquifer occupies a narrow surficial glacial-diversion stream The first owner of the plant was Central Power Electric Cooperative, Inc. According to Bluemle (1982), the lignite-bearing, Tertiary-age Bullion Creek and Sentinel Butte Formations subcrop beneath the glacial sediment in southwestern McHenry County. According to Blumble (1982) and http://nepis.epa.gov/Adobe/PDF/91017AX3.PDF, Consolidation Coal Company mined about 319 and 335 thousand tons of coal in their Velva mine, Ward County, during 1977 and 1980, respectively, to supply the William J. Neal Power Plant. According to Bureau of Mines (1954), the plant was originally designed to burn lignite with 39 percent moisture, 6.6 percent ash, and 6,600 BTU/lb. The 50 MW power plant that operated to 1985 was dismantled in 1999-2000. According to http://ngmdb.usgs.gov/Geolex/NewRefsmry/sumry_7577.html, in North Dakota the Coleharbor ranges from 0-600 ft thick. It lies stratigraphically between pre- and postglacial sediments. Its age is indicated as "from several hundred thousand to about 9,000 years ago," or Pleistocene and Holocene.
research reportNot linked to a paper · refsec · cited link
Bluemle (1982) IIa. CCR Damage Case Reassessment
research reportNot linked to a paper · refsec
Ibid, Page 3-49. IIa. CCR Damage Case Reassessment December 2014 were detected. The 1995 investigation results indicated site constituents were not responsible for the water supply well contamination. Resolution: The facility was closed between 1989 and 1990, when the impoundment sediments were consolidated to a 22-acre area and capped with an 18-inch engineered clay cover and an 18-inch layer of topsoil, which was seeded and mulched. Under the Comprehensive Environmental Response,
research reportNot linked to a paper · refsec
Compensation, and Liability Act (CERCLA), the site underwent a preliminary assessment (PA) in 1990 and a site inspection (SI) in 1995. According to the Report to Congress (ibid), “Site closed and capped and pending NFRAP (“No Further Remedial Action Planned”).454 According to EPRI (2010), remediation is complete. The site received final closure in 2000 and North Dakota Department of Health authorized groundwater monitoring well abandonment. The groundwater monitoring wells were approved for abandonment in 2000. Basis for Consideration as a Proven Damage Case: “EPA has categorized this case as a proven damage case for the following reasons: (1) Scientific investigation - Several constituents have exceeded their (health-based) primary MCLs in down-gradient ground water, and the site inspection found documentation of releases to ground water and surface water from the site; and (2) Administrative - The State required closure of the facility.”455 Postscript: ICF (2010) downgraded this case from Proven to Potential, citing ”MCL exceedances for cadmium and lead and SMCL for zinc in an onsite public water supply well”. However, accessible references have not corroborated the onsite location of the impacted drinking water well. References
research reportNot linked to a paper · refsec
EPA (2007): Coal Combustion Waste Damage Case Assessments, Case #23, docket ID EPA-HQ-RCRA2006-0796-0015, U.S. EPA Office of Solid Waste, July 9, 2007; and reference therein (Memorandum from SAIC to Dennis Ruddy regarding Review of Causative Factors for Coal Combustion Waste Damage
journal articleNot linked to a paper · refsec
Cases, November 29, 2000). Accessed Online October 2012. http://www.regulations.gov/#!documentDetail;D=EPA-HQ-RCRA-2006-0796-0015
datasetNot linked to a paper · refsec · cited link
EPRI (2010): Evaluation of Coal Combustion Product Damage Cases, Volume 2: Site Information. EPRI 1020554, Final Report, September 2010. Accessed Online August 2012. http://www.epri.com/search/Pages/results.aspx?sq=1&k=Evaluation%20of%20Coal%20Combustion%20 Product%20Damage%20Cases Report to Congress (1999): Waste from the Combustion of Fossil Fuels, Volume 2 – Methods, Findings, and Recommendations. EPA 530-R-99-010, March 1999. Accessed Online August 2014. http://www.epa.gov/osw/nonhaz/industrial/special/fossil/regs.htm North Dakota State Water Commission: Geology and Groundwater Resources of McHenry County, North Dakota (including the two specific reports below and associated maps). http://www.swc.nd.gov/4dlink9/4dcgi/GetContentRecord/PB-267
government reportNot linked to a paper · refsec · cited link
EPA (2007). IIa. CCR Damage Case Reassessment December 2014 Bluemle (1982): Geology of McHenry County, North Dakota, John P. Bluemle, North Dakota Geological Survey Bulletin 74--Part I and County Groundwater Studies 33-Part I, North Dakota State Water
government reportNot linked to a paper · refsec
Commission, Grand Forks, North Dakota, 1982. Accessed Online January 2013. http://www.swc.nd.gov/4dlink9/4dcgi/GetSubContentPDF/PB-273/McHenry_Part_1.pdf Plate 1 (Geologic map): http://www.swc.nd.gov/4dlink9/4dcgi/GetSubContentPDF/PB274/McHenry_Part_1_Plates.pdf Randich (1981): Ground-Water Resources of McHenry County, North Dakota, P. G. Randich, U.S. Geological Survey. County Ground-Water Studies 33 - Part III, North Dakota State Water Commission Bulletin 74 - Part III, and North Dakota Geological Survey, 1981. Accessed Online January 2013. http://www.swc.nd.gov/4dlink9/4dcgi/GetSubContentPDF/PB-277/McHenry_Part_3.pdf Bureau of Mines (1954): Technology of Lignitic Coals, Part 2 – Combustion-Power Generation; Carbonization; Gasification; Hydrogenation; Other Chemical Processing, Bureau of Mines Staff, Grand
datasetNot linked to a paper · refsec · cited link
EPRI (2010) concedes exceedances of selenium and sulfate. Duke Energy Ohio reported to the Ohio EPA on April 26, 1999 a significant drop in pond water elevation on Pond C during a two day period of operation. Underwater divers identified the problem as holes below the control point in the vertical section of the overflow pipe. Some ash escaped into Little Indian Creek exceeding TSS limits before corrective measures could be completed.463 Resolution: Ash sluicing ceased in 1985. An interceptor well was installed in 1993 to prohibit a sulfate plume from reaching off-site public water supply wells (Ohio EPA encouraged the facility to install this well, although there was no formal compliance action.) The one public water supply well that was located on site has been abandoned.464 Remediation has been performed. A groundwater monitoring program is in effect and sulfate concentrations are decreasing. In 1996 and 1997, Cinergy was issued a NOV by EPA for violating the Ohio SIP for particulate matter.465 Basis for Consideration as a Potential Damage Case: “While a public water supply well within the property boundary was shut down, the contaminant of concern (sulfate) in the water supply well does not
government reportNot linked to a paper · refsec
EPA (2007): Coal Combustion Waste Damage Case Assessments, Case #61 and a reference therein (Memorandum from SAIC to Dennis Ruddy regarding Final Revised Report on Resolution of 18 Previously Indeterminate Candidate Damage Cases, March 5, 2003.) http://www.regulations.gov/#!documentDetail;D=EPA-HQ-RCRA-2006-0796-0015 This observation is based on a Bedrock Geology Map of Ohio compiled by the Ohio Division of Geological Survey 2006. In April and August 2009 BBCM observed a sinkhole at east dike of the Ash Pond C. In August 2009 the sinkhole was approximately six feet in diameter at the existing ground surface and three to four feet deep. Following the submittal of a Sinkhole Investigation and Repair Plan letter, ODNR concurred and repair work was conducted in October and November 2009. Ibid. In its comment to the docket, EPA-HQ-RCRA-2009-0640-8226, OHEPA concedes that analysis data from samples taken from monitoring wells around the fly ash ponds at the power station indicate sulfate contamination. These impoundments are near a public well field. This situation was investigated several years ago and remedial actions were implemented. The site continues to monitor groundwater.
government reportNot linked to a paper · refsec · cited link
EPA imposed a $77,000 penalty, and established a 3-year compliance program. Another NOV was issued in December 1999 following additional violation (0.49 lb-PM/million BTU heat input – x4.9 the allowable standard): http://yosemite.epa.gov/r5/r5ard.nsf/16293012b80243a38625759a0047e794/bf1c070751566809862574c8006e2232/ $FILE/Cinergynov.PDF
government reportNot linked to a paper · refsec · cited link
EPRI’s (2010) tabulation of exceedances in groundwater before/after remediation is based on a database provided by the power company containing all analytical results from 1982 to 1998; results prior to 1997 used for preremediation, and 1997-1998 results used for post-remediation. Manganese source considered uncertain because the
datasetNot linked to a paper · refsec
SMCL exceedances all occurred in a monitoring well with low sulfate concentrations, and sulfate is the primary indicator for coal ash impacts at this facility. IIa. CCR Damage Case Reassessment December 2014 Resolution: In 1993, a Permit-to-Install was issued for leachate collection, pH neutralization, and sedimentation system for the landfill.475 According to EPRI (2010), the landfill was closed and capped with 2 feet of clay in 1996. The site is closed and remediation has been performed, and groundwater monitoring is no longer required. Today the property is utilized as a model airplane flying field.476 Basis for Consideration as a Potential Damage Case: “The sulfate exceedances found at this site are of non-health-based standards. Therefore, this case is a potential damage case.”477 References
research reportNot linked to a paper · refsec
EPA (2007): Coal Combustion Waste Damage Case Assessments, Case #58 and a reference therein (Memorandum from SAIC to Dennis Ruddy regarding Rationale and Conclusions Regarding CommenterIdentified Fossil Fuel Combustion Waste Damage Cases, April 20, 2000). http://www.regulations.gov/#!documentDetail;D=EPA-HQ-RCRA-2006-0796-0015
government reportNot linked to a paper · refsec · cited link
EPRI (2010): Evaluation of Coal Combustion Product Damage Cases, Volume 2: Site Information. EPRI 1020554, Final Report, September 2010. Accessed Online August 2012. http://www.epri.com/search/Pages/results.aspx?sq=1&k=Evaluation%20of%20Coal%20Combustion%20 Product%20Damage%20Cases Dames & Moore (1994): Report: Sulfate Investigation, Miamiview Landfill, Hamilton County, Ohio, Prepared for the Cincinnati Gas & Electric Company by Dames & Moore. December 13, 1994. Available in the docket titled Availability of Report to Congress on Fossil Fuel Combustion; Request for Comments and Announcement of Public Hearing, EPA-HQ-RCRA-1999-0022-0632.
government reportNot linked to a paper · refsec · cited link
Miamiview Road Ash Landfill (2012): Miamiview Road Ash Landfill, Hamilton County Public Health Closed Landfill Summary, 12/7/2012. Accessed Online January 2013. http://www.hamiltoncountyhealth.org/files/files/Reports/Waste%20Management/Closed_Landfill_Summ aries/Miamiview_Road_Ash_Landfill.pdf PTa32. TVA Bull Run Fossil Plant, Clinton (Oak Ridge), Anderson County, Tennessee Type: Surface Impoundments (impacting surface water and groundwater). Background and Description: The Bull Run Fossil Plant (BRF)478 is located along the east shore of the Clinch River and along Worthington Branch, just north (upstream) of the confluence of the river and Miamiview Road Ash Landfill (2012). Ibid.
datasetNot linked to a paper · refsec · cited link
EPA (2007). According to Sutton et al., (2001) and http://www.tva.com/sites/bullrun.htm, the BRF is a one-unit, 900 MW (870 MW net) generation capacity. Elsewhere (TVA 2012), the nameplate generating capacity is cited as 950 MW. In operation since June 1967, it is the only single-generator coal-fired plant in the TVA system. The plant consumes about 7,300 tons of coal a day. Coal, with an average of two percent sulfur and 9.6 percent ash, is delivered from over ten mid-Appalachian mines. A wet FGD scrubber came on line in December 2008. http://www.tva.com/sites/bullrun.htm and http://www.powermag.com/issues/cover_stories/Top-Plants-Bull-RunFossil-Plant-Clinton-Tennessee_2176.html IIa. CCR Damage Case Reassessment December 2014 Bull Run Creek, on the east side of the Melton Hill Reservoir479 in Clinton, Tennessee.480 Originally, the
government reportNot linked to a paper · refsec · cited link
TVA (2005), Figure 3-5, and TVA (2012), Figure 1-2. According to TVA (2005), before the mid-1980s, disposal of fly ash and bottom ash at BRF included sluicing to the ash pond, located on the east side of the Clinch River at Clinch River Mile 47, with subsequent dredging and stacking of ash within Disposal Areas 1 and 2A. As these were filled, ash was dredged and stacked at a disposal site referred to as the Railroad Loop Ash Disposal Area. This site is now a closed landfill. Disposal Areas 1 and 2A are still currently used for disposal of bottom ash and dredged fly ash. Since the mid-1980s, fly ash has been mostly dry-handled: according to Stantec (ibid), approximately 240,000 tons of dry fly ash used to be collected in a silo each year and hauled to an onsite permitted dry stack disposal area (Dry Fly Ash Stack). Since the end of 2008, when a scrubber was installed, approximately 240,000 dry tons of scrubber gypsum are produced each year and wet sluiced to the permitted gypsum stacking area (Gypsum Disposal Area 2A). Approximately 25,000 tons per year of bottom ash is wet-sluiced to the main fly ash pond (Area 2). Finally, for approximately 50,000 tons of the scrubber gypsum the plan was to have it marketed offsite to the cement industry.
government reportNot linked to a paper · refsec
Lemiszki (1994), Stantec (ibid), and TVA (2012). Residuum produced from the Chickamauga is a silty-clay containing variable amounts of chert. In the main BRF area, the majority of this clayey soil has been removed, and the remaining residuum is expected to range in thickness
research reportNot linked to a paper · refsec
EPRI (2010) refers to the implicated pond as a 49- acre, unlined impoundment constructed in 1965, which contains fly ash, bottom ash, and pyritic mill rejects. According to Stantec (ibid), some ash siltation was observed in the drainage ditch of BAD-1 during Stantec’s early 2009 site visit inspections, and major ash deposit was noted at the confluence of drainage ditch and ash channel on southeast side of stack. Standing water was observed in the drainage ditch along the access road on the west and south side of the stack. Water was stagnant and varied in width between 4 feet and over 8 feet. This has been already noted in previous inspection reports starting in 1983. Coutant et al., (1978).
government reportNot linked to a paper · refsec
WQCB Petition (2012). TDEC gave public notice of its decision to issue the Permit on October 1, 2010. The petitioners, Tennessee Clean Water Network and Southern Alliance for Clean Energy, contend generally that the Permit will allow pollution in the waters of the state of Tennessee and is not adequately protective. They claim that TDEC violated the Clean Water Act and the Tennessee Water Quality Control Act by issuing a NPDES permit to TVA that does not include any numeric technology-based effluent limits for metals, TDS, and other parameters aside from pH, TSS, and oil and grease. The Petitioners contend that TDEC must reverse the isuance of this Permit and reissue it inclusive of numeric technology-based effluent limitations (TBELs) for all pollutants to be discharged from the BRF. Petitioners claim that this revised permit should be re-noticed and opened to the public review and comment.
research reportNot linked to a paper · refsec
TVA (2002). Based on monthly measurements from 1957 to 1986: TVA (2002). Summarized in the Bull Run Fossil Plant Groundwater Assessment (Julian and Danzig, 1996), in TVA (2002). IIa. CCR Damage Case Reassessment December 2014 quality sampling show that concentrations of hardness, calcium, sodium, sulfate, TDS, and arsenic increase downstream. The upstream and downstream stations for Worthington Branch seem to indicate some leachate impacts. Groundwater: The GDA-2A and DS1, managed under Permits IDL 01-0208 and IDL 103-808, respectively, have been recently implicated in groundwater impacts.503 Recent groundwater monitoring data around the landfill and surface impoundments indicate an exceedance of the MCL for arsenic and exceedances of health- based guidelines for boron, manganese, molybdenum, and sulfate. 504 There are currently 12 wells monitoring groundwater at BRF. Four wells surround the Dry Fly Ash
government reportNot linked to a paper · refsec
TVA Inspector General (2011): exceedances of cadmium, cobalt, nickel, and fluoride were noted mostly in the May 2009 sample data.
research reportNot linked to a paper · refsec
EIP (2011), Page B.5 identifies arsenic at 27 ppb (x 2.7 the MCL), boron at 17ppm (x 5.7 the SMCL), manganese at 24.7ppm (x 82 the SMCL), molybdenum at 700 ppb (x 17.5 the SMCL), and sulfate at 2,100ppm (x 4.2 the
government reportNot linked to a paper · refsec
SMCL). It is not clear how these particular exceedances relate to the ones pointed out by the TVA Inspector General (2011) either temporally or spatially. IIa. CCR Damage Case Reassessment December 2014 Resolution: According to EPRI (2010), in the mid-1970s, repairs were made in the impacted surface water ditch adjacent to the impoundment and wastewater was routed through the impoundment’s NPDES permitted outfall.505 On August 20, 2009, TVA’s Board of Directors decided to convert Bull Run’s waste management by switching to gypsum dewatering and from wet bottom ash handling to dry storage.506
research reportNot linked to a paper · refsec
TVA received official notification on July 17, 2009, that BRF was being placed into Phase III Groundwater Monitoring assessment due to a groundwater protection standard exceedance for cobalt at the Gypsum/Coal Ash Landfill Area. However, TVA provided TDEC with a Cobalt Investigation Report that satisfied TDEC that the cobalt exceedance was related to a legacy condition that was ongoing prior to the establishment and operation of the Gypsum/Coal Ash Landfill Area. TVA was taken out of Phase III and placed into Phase II based on statistical exceedances for cadmium and nickel. Additionally, on January 7, 2010, BRF received notification that the Dry Ash Disposal Area was being placed in Phase II assessment due to an arsenic exceedance.507 BRF is currently seeking an additional disposal space508 and is also considering other by-product handling changes. 509 Basis for Consideration as a Potential Damage Case: According to EPA (2007), This case was categorized as a potential damage case for the following reasons: (1) exceedances of the secondary MCLs for aluminum, calcium, iron, and sulfate were detected in on-site surface water; (2) a toxicity study indicates the potential for ecological impacts; and (3) these impacts appear to be directly attributable to
research reportNot linked to a paper · refsec
EPA (2007): 2007 CCW Damage Case Assessments, Case #31 and reference therein (Compendium of nineteen alleged coal combustion wastes damage cases, May 3, 2007). http://www.regulations.gov/#!documentDetail;D=EPA-HQ-RCRA-2006-0796-0015
government reportNot linked to a paper · refsec · cited link
EPRI (2010): Evaluation of Coal Combustion Product Damage Cases, Volume 2: Site Information. EPRI 1020554, Final Report, September 2010. Accessed Online July 2012.
government reportNot linked to a paper · refsec
EPRI (2010). TVA (No date, presumably 2009)
government reportNot linked to a paper · refsec
TVA Inspector General (2011). As of mid-2011, TVA has been purchasing properties for its Claxton storage expansion project: TVA needs about 175 acres for the expanded storage facility (for the storage of dried fly ash, bottom ash and gypsum), including surrounding land to serve as a buffer zone. At that time, TVA has presumably about 18 months of life left in its existing dry-storage area at Bull Run. TVA could get another five years of storage on a 5-acre tract on TVA land next to the steam plant. http://www.knoxnews.com/news/2011/jul/15/tva-footprint-looms-over-community/?print=1. This expansion is subject to a NEPA process (January 2013 – summer 2015) http://www.tva.gov/power/construction/BRF_boundary_expansion.html. Following the December 2008 Kingston incident, TVA reviewed its practices for handling and storing CCRs at its generating facilities, including the BRF, which resulted in a recommendation (Stantec, ibid) to convert the wet bottom ash and gypsum handling and storage facilities at BRF to a dry system. To enable the wet-to-dry conversion,
research reportNot linked to a paper · refsec · cited link
NEPA. Accordingly, TVA has prepared an Environmental Assessment (TVA 2012) to evaluate alternatives for converting wet ponding operations to dry operations for handling and disposing of bottom ash and gypsum at BRF. IIa. CCR Damage Case Reassessment December 2014 http://my.epri.com/portal/server.pt?space=CommunityPage&cached=true&parentname=ObjMgr&parenti d=2&control=SetCommunity&CommunityID=405
research reportNot linked to a paper · refsec · cited link
EIP Report, Dec. 13, 2011. EPA-HQ-RCRA-2011-0392-0259. Accessed Online July 2012. http://www.environmentalintegrity.org/documents/121311EIPThirdDamageReport.pdf Coutant et al., (1978): Chemistry and Biological Hazard of Coal ash Seepage Stream/C.C. Coutant et al., Journal Water Pollution Control Federation, Vo. 50, No. 4, April 1978. Accessed Online July 2012. http://www.jstor.org/pss/25039619 Sutton et al., (2001): Radon Emissions from High Volume Coal Fly Ash Structural Fill Site, M.E. Sutton, T. Schmaltz, E.C. Miller, and K.J. Harper, 2001 International Ash Utilization Symposium, University of Kentucky. Accessed Online July 2012. http://www.flyash.info/2001/envben2/91sutton.pdf
journal articleNot linked to a paper · refsec · cited link
TVA Inspector General (2011): Final Report – Inspection 2009-12991 – TVA's Groundwater Monitoring at Coal Combustion Products Disposal Areas, TVA Office of the Inspector General Inspection Report, June 21, 2011. Accessed Online November 2012. http://oig.tva.gov/reports/PDF/11rpts/2009-12991.pdf
datasetNot linked to a paper · refsec · cited link
WQCB Petition (2012): Petition for Statutory Appeal to the Tennessee Water Quality Control Board In the Matter of Tennessee Department of Environment and Conservation, Division of Water Pollution
research reportNot linked to a paper · refsec
Control, NPDES Permit Number TN0005410, May 2012. Accessed Online November 2012. http://www.southeastcoalash.org/wp-content/uploads/2012/05/FINAL-Bull-Run-permit-Appealpetition_4.pdf Lemiszki (1994): Geological Mapping of the Oak Ridge K-25 Site, Oak Ridge, Tennessee, P.J. Lemiszki, Environmental Restoration Program Division, K-25 Environmental Restoration Program, Report K/ER111. Prepared by Environmental Sciences Division, Oak Ridge National Laboratory, Oak Ridge,
datasetNot linked to a paper · refsec · cited link
Tennessee, and Department of Geological Sciences, University of Tennessee, Knoxville, Tennessee, prepared for U.S. Department of Energy Office of Environmental Restoration and Waste Management, January 1994. Accessed Online February 2013. http://www.osti.gov/energycitations/servlets/purl/585045-7Ugsq3/webviewable/585045.pdf Stantec (2009): TVA Disposal Facility Assessment Phase 1 Plant Summary, Bull Run Fossil Plant (BRF), Stantec. Accessed Online February 2013. http://www.tn.gov/environment/kingston/pdf/tva/StantecBullRunAnalysisC.pdf
datasetNot linked to a paper · refsec · cited link
TVA (2012): Bottom Ash and Gypsum Mechanical Dewatering Facility, Bull Run Fossil Plant Final Environmental Assessment, Anderson County, Tennessee, Tennessee Valley Authority, Knoxville,
government reportNot linked to a paper · refsec
Tennessee, September 2012. Accessed Online February 2013. http://www.tva.gov/environment/reports/BRFdewater/EA.pdf
datasetNot linked to a paper · refsec · cited link
TVA (2005): Installation of Flue Gas Desulfurization System at Bull Run Fossil Plant, Anderson County,
government reportNot linked to a paper · refsec
Tennessee, Draft Environmental Assessment, Project Number 2004-103, TVA, January 2005. Accessed Online February 2013. http://www.tva.gov/environment/reports/bullrun2/dea.pdf
datasetNot linked to a paper · refsec · cited link
TVA (2002): Selective Catalytic Reduction System for Nitrogen Oxide Control, Bull Run Fossil Plant Unit 1, Draft Environmental Assessment, TVA, January 2002. Accessed Online February 2013. IIa. CCR Damage Case Reassessment December 2014 http://www.tva.gov/environment/reports/bullrun/index.htm
government reportNot linked to a paper · refsec · cited link
TVA (No date, presumably 2009): TVA’s Conversion of Wet Ash and Gypsum to Dry Storage. TVA. Accessed Online August 2014. http://www.tva.gov/news/Kingston/dry_ash.pdf Dewberry & Davis (2012): Coal Combustion Residue Impoundment Round 11 - Dam Assessment Report: Bull Run Fossil Plant (#002), CCR Impoundment Areas 1, 2, 2A, Tennessee Valley Authority,
government reportNot linked to a paper · refsec · cited link
CDM (2011) identified ten constituents in shallow groundwater onsite that are elevated as compared to the baseline data set: aluminum, ammonia, iron, magnesium, manganese, nickel, nitrate, nitrite, sulfate, and zinc. With the exception of nitrite, all of these constituents were detected by leaching tests performed on the fly ash. Analyses for nitrite have not been performed on the fly ash. It is likely that these constituents are elevated because of the site. However, none of these constituents presents current groundwater plumes that can be reasonably mapped by concentration and they have apparently irregular spatial distribution patterns. This is likely because sufficient time has not elapsed following fill emplacement for the water quality effects to become fully recognizable.521 Stokes Environmental Associates (ibid, page 8), cites significantly higher levels of iron and manganese: According to a U.S. Geological Survey, National Research Program study: Quality of Ground Water, Water Quality
government reportNot linked to a paper · refsec
Appendix A, Case #27. ICF, 10/2010. Comment to the docket EPA-HQ-RCRA-2009-0640-9284.
research reportNot linked to a paper · refsec
EPA-HQ-RCRA-2011-0392-0254. The other four pending lawsuits and countersuits involve the various companies that helped develop the golf course as they seek to protect themselves from liability and enforce old contracts. In one, Wallace’s company, CPM
government reportNot linked to a paper · refsec
Virginia, claims the golf course owners missed a payment deadline and owe $700,000 plus interest. He said his company wants to reclaim the property so it can work to remove the fly ash. The golf course owners counter that Wallace’s company failed to properly cover the fly ash with 18 inches of topsoil before selling them the property. The club said it paid outside contractors $2 million to “fully satisfy” construction-permit requirements, so Wallace’s company actually owes them $1.3 million. The Virginian Pilot (ibid). Federal Register (June 21, 2010). IIa. CCR Damage Case Reassessment December 2014
research reportNot linked to a paper · refsec
EPA (2010). Final Site Inspection Report for the Battlefield Golf Club Site, Tetra Tech., EPA Contract No. EP-S3-05-02, April 2010. Accessed Online October 2012. http://www.epa.gov/reg3hwmd/CurrentIssues/finalr-battlefield_golf_club_site/index.html Stokes Environmental Associates (2002): Baseline Drinking Water Quality Survey, Etheridge Greens Site Golf Course Development, Chesapeake, Virginia. Prepared by Stokes Environmental Associates, Ltd. for Combustion Products Management, Easley, South Carolina, 27 February 2002. Accessed Online August 2014. Ref 15 (PDF) - Environmental Protection Agency The Virginian-Pilot (2010): Former worker: Agency's OK to use fly ash 'unconscionable'. PilotOnline.com, October 3, 2010. Accessed Online August 2014. http://hamptonroads.com/2010/10/former-worker-agencys-ok-use-fly-ash-unconscionable O’Brien & Gere (2010): Dam Safety Assessment of CCW Impoundments, Chesapeake Energy Center, O’Brien & Gere Engineers, Inc., September 30, 2010. Accessed Online August 2014. http://www.epa.gov/osw/nonhaz/industrial/special/fossil/surveys2/index.htm#V City of Chesapeake, Virginia: Information Related to Battlefield Gold Club. Accessed Online October 2012. http://www.cityofchesapeake.net/page2077.aspx
government reportNot linked to a paper · refsec · cited link
CDM (2011): City of Chesapeake Battlefield Golf Club Hydrogeologic Investigation and Groundwater Modeling Report, CDM, March 15, 2011. Accessed Online October 2012. http://www.cityofchesapeake.net/Assets/documents/departments/city_attorney/battlefield_golf_club/Hydr ogeologic_Investigation_and_Groundwater_Modeling_Report/6000-60057.pdf.pdf Fehrenbach et al., (2011): Recent Developments in Coal Ash Disposal/Reuse Litigation. The American Bar Association's Annual Review 2011, Volume 2: Section 15.3. John Fehrenbach, Eric P. Gotting, Scott P. DeVries, Yelitza V. Dunham, Averil M. Edwards, and Michael T. Champion, Winston & Strawn LLP, and Andreas H. Leskovsek, Dynegy Inc. Accessed Online July 2012. http://www.winston.com/siteFiles/Publications/Ann.Rev.11ch15%20Environmental%20Law.pdf The Virginian Pilot (2013): Chesapeake fly ash fight yields little resolution, The Virginian Pilot, May 5, 2013. Accessed Online January 2013. http://hamptonroads.com/2013/05/chesapeake-fly-ash-fight-yields-little-resolution Blue Virginia (2014): Burned Once, Chesapeake Shouldn't Trust Dominion Virginia Power. Blue
journal articleNot linked to a paper · refsec · cited link
Virginia, July 14, 2014. Accessed Online August 2014. http://www.bluevirginia.us/diary/11884/burned-once-chesapeake-shouldnt-trust-dominion-virginia-power PTa34. Dairyland Power Cooperative Alma Off-site Fly Ash Landfill, Alma, Belvidere Township,537 Buffalo County, Wisconsin Type: CCR Landfill (Originally, a Surface Impoundment). According to WDNR’s comment to the proposed CCR Rule: EPA-HQ-RCRA-2009-0640-6416, Appendix