Policy Replication

Damage Case Compendium Technical Support Document, Volume IIa: Potential Damage Cases - DCN SE04459

Docket document2015-11-03 · EPA · report · EPA-HQ-OW-2009-0819-5768
RIN 2040-AG41, RIN 2040-AF77, RIN 2040-AF14, RIN 2040-AG54, RIN 2040-AG48, RIN 2040-AG23, RIN 2040-AF76 · Docket EPA-HQ-OW-2009-0819

Other documents for the same rulemaking

2009-10-29 Docket documentSteam Electric Power Generating Point Source Category: Final Detailed Study Report [EPA 821-R-09-008] [DCN 00003]
2009-10-29 Docket documentSupporting Statement for the Draft Questionnaire for the Steam Electric Power Generating Effluent Guidelines Information Collection Request [DCN 00001]
2009-10-29 Docket documentDraft Questionnaire for the Steam Electric Power Generating Effluent Guidelines [DCN 00002]
2009-10-29 Docket documentAgency Information Collection Activities; Proposed Collection; Comment Request; Proposed Information Collection Request for the Steam Electric Power Generating Effluent Guidelines; EPA ICR No. 2368.01, OMB Control No. 2040-NEW
2009-12-30 Docket documentLetter to Peter Silva, USEPA from Elizabeth E. Aldridge, Hunton and Williams L.L.P on behalf of the Utility Water Act Group (UWAG) [DCN SE00112]
2009-12-31 Docket documentLetter to Elizabeth E. Aldridge, Hunton and Williams, LLP from Peter S. Silva, Assistant Administrator, USEPA [DCN SE00113]
2010-03-09 Docket documentLetter to Ron Jordan, USEPA/Engineering and Analysis Division regarding USEPA Draft Steam Effluent Guidelines Questionnaire (November 17, 2009) [DCN SE00195]
2010-03-09 Docket documentLetter to Ron Jordan, USEPA/Engineering and Analysis Division regarding Comments on USEPA (February 1, 2010) [DCN SE00197]
2010-03-09 Docket documentEmail to Ron Jordan, USEPA/Engineering and Analysis Division regarding Steam Electric Power Generating EG - Proposed ICR Follow up Materials (January 20, 2010) [DCN SE00198]
2010-03-09 Docket documentLetter to Ron Jordan, USEPA/Engineering and Analysis Division regarding Ash Handling Systems Cost List (February 18, 2010) [DCN SE00200]
2010-03-09 Docket documentSupporting Statement for the Draft Questionnaire for the Steam Electric Power Generating Effluent Guidelines Information Collection Request (Part A) [DCN SE00205]
2010-03-09 Docket documentEmail to Ron Jordan, USEPA (February 19, 2010) [DCN SE00191]
2010-03-09 Docket documentEmail to Defenders of Wildlife, Sierra Club, Environmental Integrity, Earth Justice, and Natural Resources Defense Council [DCN SE00192]
2010-03-09 Docket documentEmail to Utility Water Act Group, American Public Power Association, and Edison Electric Institute [DCN SE00193]
2010-03-09 Docket documentEmail to Ron Jordan, USEPA dated February 3, 2010 [DCN SE00199]
2010-03-09 Docket documentAgenda and Example Flue Gas Desulfurization (FGD) Diagram for Discussion Between USEPA and Utility Water Act Group (UWAG) [DCN SE00201]
2010-03-09 Docket documentMemorandum to Steam Electric Record [DCN SE00204]
2010-03-09 Docket documentRon Jordan and Jezebele Alicea (February 25, 2010) [DCN SE00203]
2010-03-09 Docket documentEmail to Ron Jordan, US EPA (January 22, 2010) [DCN SE00190]
2010-03-09 Docket documentMemorandum to Ron Jordan, USEPA [DCN SE00206]
2010-03-09 Docket documentAgency Information Collection Activities; Submission to OMB for Review and Approval; Comment Request; Questionnaire for Steam Electric Power Generating Effluent Guidelines (NEW); EPA ICR No. 2368.01, OMB Control No. 2040-NEW
2013-06-07 Regulatory impact analysisRegulatory Impact Analysis For EPA’s Proposed RCRA Regulation Of Coal Combustion Residues (CCR) Generated by the Electric Utility Industry [DCN SE02969]
2013-06-07 Regulatory impact analysisTechnical Support Document: Calculating Benefit Per-Ton Estimates. Final Ozone NAAQS regulatory impact analysis [DCN SE03161]
2013-06-07 Regulatory impact analysisRegulatory Impact Analysis of the Clean Air Mercury Rule (EPA-452/R-05-003) [DCN SE03159]
2013-06-07 Regulatory impact analysisRegulatory Impact Analysis for the Industrial Boilers and Process Heaters NESHAP: Final Report (EPA-452/R-04-0020) [DCN SE03156]
2013-06-07 Regulatory impact analysisRegulatory Impact Analysis for the Proposed Effluent Limitations Guidelines and Standards for the Steam Electric Power Generating Point Source Category [DCN SE03170]
2013-06-07 Regulatory impact analysisFinal Regulatory Analysis: Control of Emissions from Nonroad Diesel Engines (EPA420-R-04-007) [DCN SE03157]
2013-06-07 Regulatory impact analysisQuality Assurance Project Plan (QAPP) for Economic Impact and Benefits Analysis for Steam Electric Rulemaking [DCN SE03376]
2013-06-07 Regulatory impact analysisList of Rulemaking Cost and Economic Impact Files: Steam Electric Effluent Guidelines Rulemaking [DCN SE03351]
2013-06-07 Docket documentEconomic Assessment of Damage Related to the Eagle Mine Facility [DCN SE03117]
2013-06-07 Docket documentRegulatory Impact Analysis for USEPA’s Proposed RCRA Regulation of Coal Combustion Residues (CCR) Generated by the Electric Utility Industry [DCN SE03168]
2013-06-07 Docket documentDocument submitted to initiate E.O. 12866 review - Steam Electric ELG NPRM FRN [DCN SE03884]
2013-06-07 Docket documentDocument submitted to conclude E.O. 12866 review - SteamElectricELG NPRM FRN - [DCN SE03958]
2013-06-07 Docket documentDocument of Changes Made During OMB Review Under E.O. 12866 - SteamElectric ELG NPRM FRN [DCN SE03972]
2013-06-07 Docket documentFishbase (version 07/2009) [DCN SE03047]
2013-06-07 Docket documentGuidance for Assessing Chemical Contaminant Data for Use in Fish Advisories, Volume 1 Fish Sampling Analysis, Third Edition [DCN SE01922]
2013-06-07 Docket documentDraft Human and Ecological Risk Assessment of Coal Combustion Wastes [DCN SE01834]
2013-06-07 Docket documentThe use of willingness-to-pay approaches in mammal conservation [DCN SE03191]
2013-06-07 Docket documentUsing the Basic Auto-validation Model to Assess the Effect of Environmental Quality on Texas Recreational Fishing Demand: Welfare Estimates [DCN SE03022]
2013-06-07 Docket documentNOAA National Marine Fisheries Service Southwest Regional Office, GIS Data [DCN SE03091]
2013-06-07 Docket documentSouthwest Fisheries Science Center Fisheries Biology Publications Database [DCN SE03134]
2013-06-07 Docket documentFinal report: Health Study to Assess the Human Health Effects of Mercury Exposure to Fish Consumed from the Everglades [DCN SE03152]
2013-06-07 Docket documentSTORET, EPA’s largest computerized environmental data system [DCN SE03160]
2013-06-07 Docket documentNational Recommended Water Quality Criteria [DCN SE03175]
2013-06-07 Docket documentNorth Florida Ecological Services Office Loggerhead Sea Turtle Caretta caretta [DCN SE03180]
2013-06-07 Docket documentNew Hampshire Clean Air Project Final Report Prepared for New Hampshire Public Utilities Commission [DCN SE02011]
2013-06-07 Docket documentFinal Site Visit Notes: Dominion Resources' Chesterfield Power Station [DCN SE00076]
2013-06-07 Docket documentMay 2011 National Industry-Specific Occupational Employment and Wages Estimates NAICS 221100 Electric Power Generation, Transmission and Distribution [DCN SE03221]
2013-06-07 Docket documentState Tax Rate Comparisons [DCN SE03229]
2013-06-07 Docket documentPopulation Estimates. National Population Datasets [DCN SE03241]
2013-06-07 Docket documentSustainable Financing Strategies [DCN SE03257]
2013-06-07 Docket documentAnnual Energy Outlook 2011 (AEO2011) [DCN SE03249]
2013-06-07 Docket documentEPA’s IPM Base Case v. 4.10 [DCN SE03265]
2013-06-07 Docket documentPlant Comments on Draft Kinder Morgan (Jackson Power Facility) Site Visit Notes [DCN SE00600]
2013-06-07 Docket documentFinal Engineering Site Visit Report for Georgia Power's Plant Yates [DCN SE02053]
2013-06-07 Docket documentNon CBI - Final Site Visit Notes: Appalachian Power Company's Mountaineer Plant [DCN SE02071]
2013-06-07 Docket documentNotes from Site Visit at the AES Cayuga Generation Plant on May 21, 2007 [DCN SE02061]
2013-06-07 Docket documentFinal Site Visit Notes: Tennessee Valley Authority’s Paradise Fossil Plant [DCN SE02101]
2013-06-07 Docket documentUWAG Draft Sampling Instructions for USEPA Collision Cell ICP-MS Methods Study [DCN SE00491]
2013-06-07 Docket documentPlant Comments to Belews Creek Sampling Episode Report, Revised SER [DCN SE01377]

References: 514 extracted, 0 linked to papers

Page 1Download these results: CSV · JSON
EPA (2007): 2007 Coal Combustion Waste Damage Case Assessments, Case #33 and reference therein (Memorandum from SAIC to Dennis Ruddy regarding Rationale and Conclusions regarding CommenterIdentified Fossil Fuel Combustion Waste Damage Cases, April 20, 2000. TVA Colbert ground water data, undated; and Memorandum from SAIC to Dennis Ruddy regarding Rationale and Conclusions Regarding Commenter-Identified Fossil Fuel Combustion Waste Damage Cases, April 20, 2000). http://www.regulations.gov/#!documentDetail;D=EPA-HQ-RCRA-2006-0796-0015
government reportNot linked to a paper · refsec · cited link
EPRI (2010): Evaluation of Coal Combustion Product Damage Cases, Volume 2: Site Information. EPRI 1020554, Final Report, September 2010. Accessed Online July 2012. http://www.epri.com/search/Pages/results.aspx?sq=1&k=Evaluation%20of%20Coal%20Combustion%20 Product%20Damage%20Cases Stantec (2009): TVA Disposal Facility Assessment Phase 1 Plant Summary, Colbert Fossil Plant (COF).
government reportNot linked to a paper · refsec · cited link
Stantec, January 2009. Accessed Online July 2012. http://www.tva.gov/power/stantec/al/rpt_004_appndx_b_cof_171468118.pdf According to TVA Inspector General (2011), the COF is subjected, under Risk-based Corrective Action, to semiannual monitoring of 18 parameters. The ground water quality database for Colbert is better than for most TVA sites, with data going back to 1982, with over twenty actively monitored wells (Fig. 4-1 there). Monitoring was originally required under both solid waste and NPDES permits. While Alabama exempted coal ash from landfill regulations between 1982 and 2011, ADEM continued to require monitoring pursuant to a 1993 Notice of Violation. Not all wells were sampled regularly. This compilation captures only these exceedances that were recorded at least in three sampling event per constituent. Overall, exceedances (including outliers) were noted in 21 of COF’s 25 monitoring wells.
datasetNot linked to a paper · refsec · cited link
TVA (No date, presumably 2009). IIa. CCR Damage Case Reassessment December 2014
government reportNot linked to a paper · refsec
EIP (2011): Risky Business: Coal Ash Threatens America’s Groundwater Resources at 19 More Sites.
government reportNot linked to a paper · refsec
EIP Report, December 13, 2011. EPA-HQ-RCRA-2011-0392-0259. Accessed Online July 2012. http://www.environmentalintegrity.org/documents/121311EIPThirdDamageReport.pdf Thomas et al., (1979): The Mississippian and Pennsylvanian (Carboniferous) System in the United States – Alabama and Mississippi. W. A. Thomas, W. E., Smith, and A. R. Bicker, Jr., United States Geological Survey Professional Paper 1111-I, 1979 (Issued also as Geological Survey of Alabama Reprint Series 49, University of Alabama, 1979). Accessed Online July 2012. http://www.gsa.state.al.us/documents/pubs/onlinepubs/Reprint_series/RS49.PDF
datasetNot linked to a paper · refsec · cited link
TVA Inspector General (2011): Final Report – Inspection 2009-12991 – TVA's Groundwater Monitoring at Coal Combustion Products Disposal Areas, TVA Office of the Inspector General Inspection Report, June 21, 2011. Accessed Online November 2012. http://oig.tva.gov/reports/PDF/11rpts/2009-12991.pdf Cherry et al., (2000): Review of the Global Adverse Environmental Impacts to Ground Water and Aquatic Ecosystems from Coal Combustion Wastes. Donald S. Cherry, Rebecca J. Currie, and
journal articleNot linked to a paper · refsec · cited link
David J. Soucek, Biology Department, Virginia Tech., Blacksburg, Virginia, prepared for Hoosier Environmental Council and Citizens Coal Council, Indianapolis, Indiana, March 28, 2000. Accessed Online August 2012. http://www.citizenscoalcouncil.org/wp-content/uploads/2012/07/A-REVIEW-OF-THE-ADVERSEENVIRONMENTAL-IMPACTS-OF-COAL-COMBUS.htm
datasetNot linked to a paper · refsec · cited link
TVA (2003): Colbert Fossil Plant Units 1 through 5 Reduction Systems for Control of Nitrogen Oxides, Colbert County, Alabama, Final Environmental Assessment, Project Number 2002-30, Tennessee Valley
government reportNot linked to a paper · refsec
Authority, February 2003. Accessed Online February 2013. http://www.tva.gov/environment/reports/colbert/index.htm
datasetNot linked to a paper · refsec · cited link
TVA (2004): Installation of Flue Gas Desulfurization System on Colbert Fossil Plant Unit 5, Colbert
government reportNot linked to a paper · refsec
County, Alabama, Draft Environmental Assessment, Project Number 2003-37, Tennessee Valley
research reportNot linked to a paper · refsec
Authority, February 2004. Accessed Online February 2013. http://www.tva.gov/environment/reports/colbert2/draft_ea.pdf
datasetNot linked to a paper · refsec · cited link
TVA (2008): Operational Improvements to Optimize Selective Catalytic Reduction Systems at Five Fossil Plants Tennessee, Alabama, and Kentucky, Supplemental Environmental Assessment, Project Number 2007-32, Tennessee Valley Authority, April 2008. Accessed Online February 2013. http://www.tva.gov/environment/reports/scro/2007-32_scr_opt_fea.pdf
government reportNot linked to a paper · refsec · cited link
TVA (No date, presumably 2009): TVA’s Conversion of Wet Ash and Gypsum to Dry Storage. TVA. Accessed Online August 2014. http://www.tva.gov/news/Kingston/dry_ash.pdf
government reportNot linked to a paper · refsec · cited link
Originally, TVA decided that WCF units 1 through 6, idled in 2010 and 2011, would be retired by July 31, 2015, whereas WCF units 7 and 8, with a combined summer net capacity of 974 MW, would remain active. On November 14, 2013, the TVA board of directors approved a resolution to retire Unit 8. This is in addition to previously announced commitments to retire WCF Units 1-6 by 2015. WCF Unit 7 will continue to operate (TVA, 2013). In the early 1980s, Units 7 and 8 were equipped with wet limestone scrubbers to remove particulates and sulfur dioxide emissions, as well as Selective Catalytic Reduction (SCR) systems to reduce nitrogen oxide emissions. Scrubber gypsum production at WCF ranges from about 700,000 to 750,000 cubic yards per year (including the fly ash contribution), depending on coal burn and sulfur content of the coal burned. According to the
research reportNot linked to a paper · refsec
TVA (http://www.tva.com/sites/widowscreek.htm), prior to idling of units 1 through 6, the plant used to consume about 10,000 tons of coal a day. For plans to optimize operation of an SCR system and predicted environmental implications, see TVA (2008). According to TVA (2008) and TVA (2009), the WCF fly ash is carried with the flue gas stream exiting the boiler. The Unit 7 ESP captures approximately 75 percent of the fly ash from the flue gas stream and collects it in hoppers. The fly ash from the ESP hoppers is wet sluiced to the ash pond, which discharges through Outfall DSN 001 to the Tennessee River. The partially cleaned flue gas from the Unit 7 ESP then flows through the scrubber system. A significant portion of the remaining fly ash is removed by the scrubber process. Unit 8 does not have an
government reportNot linked to a paper · refsec · cited link
ESP; therefore, the fly ash is removed solely by the scrubber system. The waste slurry from Units 7 and 8 scrubber systems is wet stacked in the FGD wet stacking area, which drains to the FGD settling pond. The FGD settling pond discharges through Outfall DSN 008 to the Tennessee River in accordance with National Pollutant Discharge Elimination System (NPDES) Permit No. AL0003875. Bottom ash is wet sluiced to the ash pond. Another source of flow to the ash pond is the Air Pre-Heater (APH) wash water through the iron pond (Outfall DSN 001b). On April 14, 2011, TVA and North Carolina settled a five-year-old lawsuit - North Carolina v. TVA - over
research reportNot linked to a paper · refsec
TVA (2009), Figures 1-2 and 2-1. In addition, there are smaller ponds on the site: copper and iron ponds, now closed, stilling ponds associated with both the Main Ash Pond and the Gypsum Stack, and a red water pond north of the Main Ash Pond (EIP, 2013, Fig. 12-1). For detailed design, operation, and waste unit disposition data, see Newberry & Davis (2012). In its assessment report on the potential groundwater impacts of the gypsum stack expansion in 1990, TVA indicates that “Widows Creek Fossil Plant is situated on karst terrain,” and that “[a]s in all karst terrains, solution activity along faults, bedding planes, joints and fractures produces enlarged openings and effective routes for groundwater movement.”(TVA, Widows Creek Fossil Plant – Assessment of Potential Effects on Groundwater of the Phase II FGD Pond (Dec. 1990), in EIP (2013, page 150).
government reportNot linked to a paper · refsec
EPRI (2010) claims that the inclusion of this site in the damage case roster is questionable because the noted (lead) contamination was in an up-gradient monitoring well. According to Cherry et al., (2000), Sulfate, boron and manganese exceed federal limits. Iron, at 71 mg/L, exceeded the MCL by 236 times. Aluminum reached 66,000µg/L in down-gradient ground water, surpassing the
government reportNot linked to a paper · refsec
EPA (2007): 2007 CCW Damage Case Assessments, Case #32 and reference therein (Memorandum from
government reportNot linked to a paper · refsec
SAIC to Dennis Ruddy regarding Rationale and Conclusions Regarding Commenter-Identified Fossil Fuel Combustion Waste Damage Cases, April 20, 2000). http://www.regulations.gov/#!documentDetail;D=EPA-HQ-RCRA-2006-0796-0015
research reportNot linked to a paper · refsec · cited link
EPRI (2010). This site also experienced a failure (January 9, 2009) of a discharge pipe, resulting in a 6.1 million gallon of FGD material containing water, gypsum and some fly ash released from an FGD pond, leading to $9.2 million in cleanup costs. TVA issued (July 7, 2009) a FONSI. EPA did not classify this as a damage case, because samples at relevant points of potential exposure complied with applicable standards (EPA 2010). For documentation of the incident and subsequent remediation, see TVA (2009) and http://www.nrt.org/production%5Cnrt%5Crrthome.nsf/resources/RRT4Aug2009Meeting_4/$File/Gypsum_Presenta tion.pdf
government reportNot linked to a paper · refsec · cited link
TVA (2009). Ibid. TVA (No date, presumably 2009). IIa. CCR Damage Case Reassessment December 2014
government reportNot linked to a paper · refsec
EPA (2010): 40 CFR Parts 257, 261, 264 et al., Page 35128-: Hazardous and Solid Waste Management System; Identification and Listing of Special Wastes; Disposal of Coal Combustion Residuals from Electric Utilities; Proposed Rule. June 21, 2010.
government reportNot linked to a paper · refsec
EPRI (2010): Evaluation of Coal Combustion Product Damage Cases, Volume 2: Site Information. EPRI 1020554, Final Report, September 2010. Accessed Online July 2012. http://www.epri.com/search/Pages/results.aspx?sq=1&k=Evaluation%20of%20Coal%20Combustion%20 Product%20Damage%20Cases
government reportNot linked to a paper · refsec · cited link
TVA issued FONSI (7/7/2009). Accessed Online July 2012. http://www.tva.gov/environment/reports/widows_creek/wcf_gypsum_removal_fonsi.pdf Cherry et al., (2000): Review of the Global Adverse Environmental Impacts to Ground Water and Aquatic Ecosystems from Coal Combustion Wastes. Donald S. Cherry, Rebecca J. Currie, and
journal articleNot linked to a paper · refsec · cited link
TVA (2009): Widows Creek Fossil Plant Gypsum Removal Project, Jackson County, Alabama, Final Environmental Assessment, Project Number 2009-38, Tennessee Valley Authority, July 2009. Accessed Online June 2012. http://www.tva.gov/environment/reports/widows_creek/widows_creek_fea_.pdf
government reportNot linked to a paper · refsec · cited link
TVA (No date, presumably 2009): TVA’s Conversion of Wet Ash and Gypsum to Dry Storage. TVA. Accessed Online August 2014. http://www.tva.gov/news/Kingston/dry_ash.pdf Lemly (2010): A White Paper on Environmental Damage from Coal Combustion Waste: The Cost of Poisoned Fish and Wildlife, A. Dennis Lemly, EPA Docket Comment No. EPA–HQ–RCRA–2009–06406313, Appendix I, December 15, 2010. Accessed Online June 2012. http://prairierivers.org/wp-content/uploads/2012/03/Lemly-2010-Environmental-Damage-from-CCW.pdf
government reportNot linked to a paper · refsec · cited link
TVA (2013): Fact Sheet: Widows Creek-Coal Retirements, November 14, 2013. Accessed Online November 2013. http://www.tva.com/news/releases/octdec13/board_files/Fact_Sheet_Widows_CreekFossil_11_14_13_Fi nal.pdf Dewberry & Davis (2012): Widows Creek Fossil Plant, Tennessee Valley Authority, Stevenson,
government reportNot linked to a paper · refsec · cited link
Alabama, Round 11 - Dam Assessment Report. Dewberry & Davis, LLC, December 2012. Accessed Online June 2014. http://www.epa.gov/epawaste/nonhaz/industrial/special/fossil/surveys2/index.htm#T IIa. CCR Damage Case Reassessment December 2014 PTa03. Arizona Public Service Co. Cholla Steam Electric Generating Station,42 Navajo
datasetNot linked to a paper · refsec · cited link
TDS, boron, sodium, and chloride). However, the concentrations presented are actually those of the leachate, rather than of impacted groundwater. Cherry et al., (2000) report is based on a Hoosier Environmental Council (HEC) comment to EPA’s Docket Number F-1999-FF2P-FFFFF, as captured in a September 24, 1999 memorandum from
research reportNot linked to a paper · refsec
HEC to Dennis Ruddy, USEPA. In the September 1999 memorandum, HEC claims that the contamination at the site actually led to the formation of Arizona’s Aquifer Protection Program. IIa. CCR Damage Case Reassessment December 2014 In a response to the 2007 NODA docket,52 APS states that the (i) baseline groundwater quality was worse than presented in EPA (2007),53 and (ii) the 2007 Assessment fails to address the fact that the ponds are permitted under Arizona’s Aquifer Protection Program and that they are subject to clean closure requirements under that program. Specifically, APS claims that the record should reflect that the 1973 water quality data, generated by APS prior to construction of the fly ash pond (from approximately the same location), indicate that TDS levels in the shallow alluvium were three times the levels cited by Earthjustice in their comment to the 2007 NODA’s Damage Case Assessment report; and that in addition, the 1973 levels of sulfate, chloride, and fluoride were all higher than the data cited by Earthjustice in their cited comment. The Assessment also states that Earthjustice alleges that the fly ash pond has “caused naturally poor water quality water from upper aquifers to contaminate the pristine lower aquifer … “ APS claims, however, that lower aquifer groundwater data from 1973 show TDS levels very similar to that found at the site in 2006.
research reportNot linked to a paper · refsec
EPA (2007): Coal Combustion Waste Damage Case Assessments, Case #67, docket ID EPA-HQ-RCRA2006-0796-0015, U.S. EPA Office of Solid Waste, July 9, 2007; and a reference therein (Memorandum from SAIC to Dennis Ruddy regarding Rationale and Conclusions Regarding Commenter-Identified Fossil Fuel Combustion Waste Damage Cases, April 20, 2000). Accessed Online October 2012.
government reportNot linked to a paper · refsec
EPA-HQ-RCRA-2006-0796-0070. This reference is the 2007 NODA’s Damage Case Assessment document. I.e., A.R.S. 49-241 et. Seq, administered by the ADEQ. Bluefish (N=12) in Cholla Lake had a dry-weight selenium tissue contents of 6.629 ± 0.679 µg/L vs. 3.91 ± 2.77 µg/L in Clear Creek Lake; and Channel Catfish (n=3) in Cholla Lake had a dry-weight selenium tissue contents of 5.164 ± 0.694 µg/L vs. 1.42 ± 0.070 µg/L in Clear Creek Lake (Shomo, 1991, Tables 10 and 12). Comment to the docket: EPA-HQ-RCRA-2009-0640-9337. As inferred from APS’ response in the NODA docket: EPA-HQ-RCRA-2006-0796-0070.
government reportNot linked to a paper · refsec
EPA (2007). IIa. CCR Damage Case Reassessment December 2014 http://www.regulations.gov/#!documentDetail;D=EPA-HQ-RCRA-2006-0796-0015 Cherry et al., (2000): Review of the Global Adverse Environmental Impacts to Ground Water and Aquatic Ecosystems from Coal Combustion Wastes. Donald S. Cherry, Rebecca J. Currie, and
journal articleNot linked to a paper · refsec · cited link
David J. Soucek, Biology Department, Virginia Tech., Blacksburg, Virginia. Prepared for Hoosier Environmental Council and Citizens Coal Council, Indianapolis, Indiana, March 28, 2000. Accessed Online October 2012. http://www.citizenscoalcouncil.org/wp-content/uploads/2012/07/A-REVIEW-OF-THE-ADVERSEENVIRONMENTAL-IMPACTS-OF-COAL-COMBUS.htm
datasetNot linked to a paper · refsec · cited link
APS (2009): Arizona Public Service Company - Cholla Generating Station: Response to Request for Information Under l04(e) of the Comprehensive Environmental Response, Compensation, and Liability
government reportNot linked to a paper · refsec
GEI (2009): Coal Ash Impoundment Specific Site Assessment Report, Arizona Public Service, Cholla Power Plant Final report, GEI Consultants, December 2009. Accessed Online October 2012. http://www.epa.gov/waste/nonhaz/industrial/special/fossil/surveys2/apsc-cholla-final.pdf
government reportNot linked to a paper · refsec · cited link
USGS Professional Paper 1625-B (no Date): Geology and Coal Resources of the Upper Cretaceous Fruitland Formation, San Juan Basin, New Mexico and Colorado, James E. Fassett, Chapter Q of Geologic Assessment of Coal in the Colorado Plateau: Arizona, Colorado, New Mexico, and Utah. Edited by M.A. Kirschbaum, L.N.R. Roberts, and L.R.H. Biewick, U.S. Geological Survey Professional Paper 1625–B. Accessed Online January 2013. http://pubs.usgs.gov/pp/p1625b/Reports/Chapters/Chapter_Q.pdf McGavock (2012): Evolution of Groundwater Quality in the Southern Part of the Coconino Aquifer,
datasetNot linked to a paper · refsec · cited link
Arizona, an extended abstract, E.H. McGavock, Montgomery & Associates, Tucson, Arizona. Accessed Online January 2014. http://azhydrosoc.org/2012Symposium/docs/abstracts/2f_McGavock.pdf Bureau of Reclamation (2006): North Central Arizona Water Supply Study—Report of Findings. U.S. Department of the Interior, Bureau of Reclamation, Denver, Colorado, October 2006. Accessed Online January 2014. http://www.usbr.gov/lc/phoenix/reports/ncawss/NCAWSSP1NOAPP.pdf Shomo (1991): Biotic and Physico-Chemical Conditions in a Cooling Reservoir of a Coal-Fired Power
datasetNot linked to a paper · refsec · cited link
Plant, Shomo, Laurie Suzanne, Master Thesis, The University of Arizona, 1991. Accessed Online January 2014. http://arizona.openrepository.com/arizona/bitstream/10150/277958/1/azu_td_1345438_sip1_m.pdf Shomo and Maughan (1991): Cooling Reservoir of a Coal-Fired Power Plant as a Warmwater Fishery,
datasetNot linked to a paper · refsec · cited link
Laurie S. Shomo and O. Eugene Maughan, pp. 229-237 in Warmwater Fisheries, Symposium I (June 4-8, 1991), edited by James L. Cooper, R. H. Hamre, Scottsdale, Arizona, USDA Forest Service, Fort Collins,
journal articleNot linked to a paper · refsec
Colorado, General Technical Report RM-207, 1991. Accessed Online January 2014. http://books.google.com/books?id=oAPy_2xYf_YC&pg=PA229&lpg=PA229&dq=Arizona+Public+Serv ice+Co.+Cholla+lake&source=bl&ots=Qybb9yqwlO&sig=ePdyLxIH7Sl5y2wsU9ICi39GD8&hl=en&sa=X&ei=IwzYUuSQOrXMsQSFpYHgDg&ved=0CC4Q6AEwAQ #v=onepage&q=Arizona%20Public%20Service%20Co.%20Cholla%20lake&f=false December 14, 2011 email from K. Morrison, EPA R8, to A. Livnat, EPA/OSWER. IIa. CCR Damage Case Reassessment December 2014 PTa04. Florida Power & Light Lansing Smith Plant, Bay County, Florida Type: Surface Impoundment. Background and Description: An unlined, 172-acre surface impoundment,59 constructed in 1965 at the Florida Power and Light Lansing Smith power plant in a coastal area60 about 15 miles north of Panama City, was first identified in the Arthur D. Little, Inc. (1985) study as cited in the 1988 Report to
datasetNot linked to a paper · refsec · cited link
SMCL, sodium at nearly 10 times the SMCL, and TDS at nine times the SMCL. According to Gulf Power (2009), the impoundment is divided into three cells: East Cell 79.2 – acres, Middle Cell - 35.4 acres, and Southwest Cell - 57.6 acres. The impoundment’s approximate Total Storage Capacity is 4,212,716 cubic yards. While subjected to the Dam Assessment survey, Southern Company and its subsidiary Gulf Power are claiming that the results of the survey contain “Confidential Business Information”. As of July 2014, while EPA is working to resolve these claims with the company, the reports are not posted (http://www.epa.gov/osw/nonhaz/industrial/special/fossil/surveys2/gulf_pclsp_southernco-cbi-comments.pdf). Today owned by Gulf Power. Gulf Power Company is an investor-owned electric utility with all of its common stock owned by Atlanta-based Southern Company. Four generation units have a total nameplate generating capacity of 890 MW. Bituminous coal is supplied from the Hobet Mine, a mountaintop removal coal mining operation in Boone County, West Virginia. The Lansing Smith Plant is located on Alligator Bayou off of North Bay in Bay County. http://www.gulfpower.com/about/plants.asp
research reportNot linked to a paper · refsec · cited link
EPRI (2010). Cited in EPA (2007). This decision was in accord with the scope of the 1993 Regulatory Determination, which addressed comanaged CCRs. Comment to the 2007 NODA docket: EPA-HQ-RCRA-2006-0796-0446.
government reportNot linked to a paper · refsec
FDEP, Solid Waste Section. Preliminary Evaluation of Analytical Data on Coal Combustion Products, (draft) March 18, 2008. IIa. CCR Damage Case Reassessment December 2014 Florida Power’s rebuttal 66 states that the alleged exceedances of radium 226 and 228 are the result of natural background conditions;67 and that the remaining alleged exceedances do not involve federal MCLs and were either the result of natural background conditions or were detected within the Zone of Discharge (ZOD), within which numerical primary and secondary drinking water standards do not apply.68 Florida’s Power & Light’s groundwater discharge permits were renewed by the FLDEP in 2004 after finding that the power plant was in compliance with all state regulations.
research reportNot linked to a paper · refsec
EPRI (2010),69 in its tabulation of exceedances in groundwater that is based on results presented in the 1988 Report to Congress claims that chromium, reported as a constituent of concern in the EPA (2007), had an MCL exceedance only in one out of 14 samples. Each of the other constituents associated with onsite impact: chloride, fluoride, iron, manganese, and sulfate, also had high concentrations in the seawater that was used for ash sluice make-up water. While representing a release from the ash pond, these constituents do not necessarily represent leaching of coal ash. Based on a few occurrences in upgradient wells,70 EPRI claims that cadmium concentrations were due to saltwater-induced mobilization of the cadmium present in sediments and geologic materials.
government reportNot linked to a paper · refsec
EPRI (2010). IIa. CCR Damage Case Reassessment December 2014 Basis for Consideration as a Potential Damage Case: This site has been reclassified as a potential damage case based on documented exceedances of primary drinking water standards for cadmium, chromium, and fluoride, and secondary drinking water standards for sulfate, chloride, manganese and iron in on-site ground water attributable to CCW. References
government reportNot linked to a paper · refsec
EPA (2007): 2007 Coal Combustion Waste Damage Case Assessments, Case #36 and reference therein (Compendium of nineteen alleged CCW damage cases, US EPA, May 3, 2007; Status of Alleged Damage Cases Submitted by the Hoosier Environmental Council, et. al., to Dennis Ruddy, February, 2002; Memorandum from SAIC to Dennis Ruddy regarding Rationale and Conclusions Regarding CommenterIdentified Fossil Fuel Combustion Waste Damage Cases, April 20, 2000). http://www.regulations.gov/#!documentDetail;D=EPA-HQ-RCRA-2006-0796-0015
government reportNot linked to a paper · refsec · cited link
Next →