Damage Case Compendium Technical Support Document, Volume IIa: Potential Damage Cases - DCN SE04459
Other documents for the same rulemaking
References: 514 extracted, 0 linked to papers
EPA (2007): 2007 Coal Combustion Waste Damage Case Assessments, Case #33 and reference therein (Memorandum from SAIC to Dennis Ruddy regarding Rationale and Conclusions regarding CommenterIdentified Fossil Fuel Combustion Waste Damage Cases, April 20, 2000. TVA Colbert ground water data, undated; and Memorandum from SAIC to Dennis Ruddy regarding Rationale and Conclusions Regarding Commenter-Identified Fossil Fuel Combustion Waste Damage Cases, April 20, 2000). http://www.regulations.gov/#!documentDetail;D=EPA-HQ-RCRA-2006-0796-0015
EPRI (2010): Evaluation of Coal Combustion Product Damage Cases, Volume 2: Site Information. EPRI 1020554, Final Report, September 2010. Accessed Online July 2012. http://www.epri.com/search/Pages/results.aspx?sq=1&k=Evaluation%20of%20Coal%20Combustion%20 Product%20Damage%20Cases Stantec (2009): TVA Disposal Facility Assessment Phase 1 Plant Summary, Colbert Fossil Plant (COF).
Stantec, January 2009. Accessed Online July 2012. http://www.tva.gov/power/stantec/al/rpt_004_appndx_b_cof_171468118.pdf According to TVA Inspector General (2011), the COF is subjected, under Risk-based Corrective Action, to semiannual monitoring of 18 parameters. The ground water quality database for Colbert is better than for most TVA sites, with data going back to 1982, with over twenty actively monitored wells (Fig. 4-1 there). Monitoring was originally required under both solid waste and NPDES permits. While Alabama exempted coal ash from landfill regulations between 1982 and 2011, ADEM continued to require monitoring pursuant to a 1993 Notice of Violation. Not all wells were sampled regularly. This compilation captures only these exceedances that were recorded at least in three sampling event per constituent. Overall, exceedances (including outliers) were noted in 21 of COF’s 25 monitoring wells.
TVA (No date, presumably 2009). IIa. CCR Damage Case Reassessment December 2014
EIP (2011): Risky Business: Coal Ash Threatens America’s Groundwater Resources at 19 More Sites.
EIP Report, December 13, 2011. EPA-HQ-RCRA-2011-0392-0259. Accessed Online July 2012. http://www.environmentalintegrity.org/documents/121311EIPThirdDamageReport.pdf Thomas et al., (1979): The Mississippian and Pennsylvanian (Carboniferous) System in the United States – Alabama and Mississippi. W. A. Thomas, W. E., Smith, and A. R. Bicker, Jr., United States Geological Survey Professional Paper 1111-I, 1979 (Issued also as Geological Survey of Alabama Reprint Series 49, University of Alabama, 1979). Accessed Online July 2012. http://www.gsa.state.al.us/documents/pubs/onlinepubs/Reprint_series/RS49.PDF
TVA Inspector General (2011): Final Report – Inspection 2009-12991 – TVA's Groundwater Monitoring at Coal Combustion Products Disposal Areas, TVA Office of the Inspector General Inspection Report, June 21, 2011. Accessed Online November 2012. http://oig.tva.gov/reports/PDF/11rpts/2009-12991.pdf Cherry et al., (2000): Review of the Global Adverse Environmental Impacts to Ground Water and Aquatic Ecosystems from Coal Combustion Wastes. Donald S. Cherry, Rebecca J. Currie, and
David J. Soucek, Biology Department, Virginia Tech., Blacksburg, Virginia, prepared for Hoosier Environmental Council and Citizens Coal Council, Indianapolis, Indiana, March 28, 2000. Accessed Online August 2012. http://www.citizenscoalcouncil.org/wp-content/uploads/2012/07/A-REVIEW-OF-THE-ADVERSEENVIRONMENTAL-IMPACTS-OF-COAL-COMBUS.htm
TVA (2003): Colbert Fossil Plant Units 1 through 5 Reduction Systems for Control of Nitrogen Oxides, Colbert County, Alabama, Final Environmental Assessment, Project Number 2002-30, Tennessee Valley
Authority, February 2003. Accessed Online February 2013. http://www.tva.gov/environment/reports/colbert/index.htm
TVA (2004): Installation of Flue Gas Desulfurization System on Colbert Fossil Plant Unit 5, Colbert
County, Alabama, Draft Environmental Assessment, Project Number 2003-37, Tennessee Valley
Authority, February 2004. Accessed Online February 2013. http://www.tva.gov/environment/reports/colbert2/draft_ea.pdf
TVA (2008): Operational Improvements to Optimize Selective Catalytic Reduction Systems at Five Fossil Plants Tennessee, Alabama, and Kentucky, Supplemental Environmental Assessment, Project Number 2007-32, Tennessee Valley Authority, April 2008. Accessed Online February 2013. http://www.tva.gov/environment/reports/scro/2007-32_scr_opt_fea.pdf
TVA (No date, presumably 2009): TVA’s Conversion of Wet Ash and Gypsum to Dry Storage. TVA. Accessed Online August 2014. http://www.tva.gov/news/Kingston/dry_ash.pdf
Originally, TVA decided that WCF units 1 through 6, idled in 2010 and 2011, would be retired by July 31, 2015, whereas WCF units 7 and 8, with a combined summer net capacity of 974 MW, would remain active. On November 14, 2013, the TVA board of directors approved a resolution to retire Unit 8. This is in addition to previously announced commitments to retire WCF Units 1-6 by 2015. WCF Unit 7 will continue to operate (TVA, 2013). In the early 1980s, Units 7 and 8 were equipped with wet limestone scrubbers to remove particulates and sulfur dioxide emissions, as well as Selective Catalytic Reduction (SCR) systems to reduce nitrogen oxide emissions. Scrubber gypsum production at WCF ranges from about 700,000 to 750,000 cubic yards per year (including the fly ash contribution), depending on coal burn and sulfur content of the coal burned. According to the
TVA (http://www.tva.com/sites/widowscreek.htm), prior to idling of units 1 through 6, the plant used to consume about 10,000 tons of coal a day. For plans to optimize operation of an SCR system and predicted environmental implications, see TVA (2008). According to TVA (2008) and TVA (2009), the WCF fly ash is carried with the flue gas stream exiting the boiler. The Unit 7 ESP captures approximately 75 percent of the fly ash from the flue gas stream and collects it in hoppers. The fly ash from the ESP hoppers is wet sluiced to the ash pond, which discharges through Outfall DSN 001 to the Tennessee River. The partially cleaned flue gas from the Unit 7 ESP then flows through the scrubber system. A significant portion of the remaining fly ash is removed by the scrubber process. Unit 8 does not have an
ESP; therefore, the fly ash is removed solely by the scrubber system. The waste slurry from Units 7 and 8 scrubber systems is wet stacked in the FGD wet stacking area, which drains to the FGD settling pond. The FGD settling pond discharges through Outfall DSN 008 to the Tennessee River in accordance with National Pollutant Discharge Elimination System (NPDES) Permit No. AL0003875. Bottom ash is wet sluiced to the ash pond. Another source of flow to the ash pond is the Air Pre-Heater (APH) wash water through the iron pond (Outfall DSN 001b). On April 14, 2011, TVA and North Carolina settled a five-year-old lawsuit - North Carolina v. TVA - over
TVA (2009), Figures 1-2 and 2-1. In addition, there are smaller ponds on the site: copper and iron ponds, now closed, stilling ponds associated with both the Main Ash Pond and the Gypsum Stack, and a red water pond north of the Main Ash Pond (EIP, 2013, Fig. 12-1). For detailed design, operation, and waste unit disposition data, see Newberry & Davis (2012). In its assessment report on the potential groundwater impacts of the gypsum stack expansion in 1990, TVA indicates that “Widows Creek Fossil Plant is situated on karst terrain,” and that “[a]s in all karst terrains, solution activity along faults, bedding planes, joints and fractures produces enlarged openings and effective routes for groundwater movement.”(TVA, Widows Creek Fossil Plant – Assessment of Potential Effects on Groundwater of the Phase II FGD Pond (Dec. 1990), in EIP (2013, page 150).
EPRI (2010) claims that the inclusion of this site in the damage case roster is questionable because the noted (lead) contamination was in an up-gradient monitoring well. According to Cherry et al., (2000), Sulfate, boron and manganese exceed federal limits. Iron, at 71 mg/L, exceeded the MCL by 236 times. Aluminum reached 66,000µg/L in down-gradient ground water, surpassing the
EPA (2007): 2007 CCW Damage Case Assessments, Case #32 and reference therein (Memorandum from
SAIC to Dennis Ruddy regarding Rationale and Conclusions Regarding Commenter-Identified Fossil Fuel Combustion Waste Damage Cases, April 20, 2000). http://www.regulations.gov/#!documentDetail;D=EPA-HQ-RCRA-2006-0796-0015
EPRI (2010). This site also experienced a failure (January 9, 2009) of a discharge pipe, resulting in a 6.1 million gallon of FGD material containing water, gypsum and some fly ash released from an FGD pond, leading to $9.2 million in cleanup costs. TVA issued (July 7, 2009) a FONSI. EPA did not classify this as a damage case, because samples at relevant points of potential exposure complied with applicable standards (EPA 2010). For documentation of the incident and subsequent remediation, see TVA (2009) and http://www.nrt.org/production%5Cnrt%5Crrthome.nsf/resources/RRT4Aug2009Meeting_4/$File/Gypsum_Presenta tion.pdf
TVA (2009). Ibid. TVA (No date, presumably 2009). IIa. CCR Damage Case Reassessment December 2014
EPA (2010): 40 CFR Parts 257, 261, 264 et al., Page 35128-: Hazardous and Solid Waste Management System; Identification and Listing of Special Wastes; Disposal of Coal Combustion Residuals from Electric Utilities; Proposed Rule. June 21, 2010.
EPRI (2010): Evaluation of Coal Combustion Product Damage Cases, Volume 2: Site Information. EPRI 1020554, Final Report, September 2010. Accessed Online July 2012. http://www.epri.com/search/Pages/results.aspx?sq=1&k=Evaluation%20of%20Coal%20Combustion%20 Product%20Damage%20Cases
TVA issued FONSI (7/7/2009). Accessed Online July 2012. http://www.tva.gov/environment/reports/widows_creek/wcf_gypsum_removal_fonsi.pdf Cherry et al., (2000): Review of the Global Adverse Environmental Impacts to Ground Water and Aquatic Ecosystems from Coal Combustion Wastes. Donald S. Cherry, Rebecca J. Currie, and
TVA (2009): Widows Creek Fossil Plant Gypsum Removal Project, Jackson County, Alabama, Final Environmental Assessment, Project Number 2009-38, Tennessee Valley Authority, July 2009. Accessed Online June 2012. http://www.tva.gov/environment/reports/widows_creek/widows_creek_fea_.pdf
TVA (No date, presumably 2009): TVA’s Conversion of Wet Ash and Gypsum to Dry Storage. TVA. Accessed Online August 2014. http://www.tva.gov/news/Kingston/dry_ash.pdf Lemly (2010): A White Paper on Environmental Damage from Coal Combustion Waste: The Cost of Poisoned Fish and Wildlife, A. Dennis Lemly, EPA Docket Comment No. EPA–HQ–RCRA–2009–06406313, Appendix I, December 15, 2010. Accessed Online June 2012. http://prairierivers.org/wp-content/uploads/2012/03/Lemly-2010-Environmental-Damage-from-CCW.pdf
TVA (2013): Fact Sheet: Widows Creek-Coal Retirements, November 14, 2013. Accessed Online November 2013. http://www.tva.com/news/releases/octdec13/board_files/Fact_Sheet_Widows_CreekFossil_11_14_13_Fi nal.pdf Dewberry & Davis (2012): Widows Creek Fossil Plant, Tennessee Valley Authority, Stevenson,
Alabama, Round 11 - Dam Assessment Report. Dewberry & Davis, LLC, December 2012. Accessed Online June 2014. http://www.epa.gov/epawaste/nonhaz/industrial/special/fossil/surveys2/index.htm#T IIa. CCR Damage Case Reassessment December 2014 PTa03. Arizona Public Service Co. Cholla Steam Electric Generating Station,42 Navajo
TDS, boron, sodium, and chloride). However, the concentrations presented are actually those of the leachate, rather than of impacted groundwater. Cherry et al., (2000) report is based on a Hoosier Environmental Council (HEC) comment to EPA’s Docket Number F-1999-FF2P-FFFFF, as captured in a September 24, 1999 memorandum from
HEC to Dennis Ruddy, USEPA. In the September 1999 memorandum, HEC claims that the contamination at the site actually led to the formation of Arizona’s Aquifer Protection Program. IIa. CCR Damage Case Reassessment December 2014 In a response to the 2007 NODA docket,52 APS states that the (i) baseline groundwater quality was worse than presented in EPA (2007),53 and (ii) the 2007 Assessment fails to address the fact that the ponds are permitted under Arizona’s Aquifer Protection Program and that they are subject to clean closure requirements under that program. Specifically, APS claims that the record should reflect that the 1973 water quality data, generated by APS prior to construction of the fly ash pond (from approximately the same location), indicate that TDS levels in the shallow alluvium were three times the levels cited by Earthjustice in their comment to the 2007 NODA’s Damage Case Assessment report; and that in addition, the 1973 levels of sulfate, chloride, and fluoride were all higher than the data cited by Earthjustice in their cited comment. The Assessment also states that Earthjustice alleges that the fly ash pond has “caused naturally poor water quality water from upper aquifers to contaminate the pristine lower aquifer … “ APS claims, however, that lower aquifer groundwater data from 1973 show TDS levels very similar to that found at the site in 2006.
EPA (2007): Coal Combustion Waste Damage Case Assessments, Case #67, docket ID EPA-HQ-RCRA2006-0796-0015, U.S. EPA Office of Solid Waste, July 9, 2007; and a reference therein (Memorandum from SAIC to Dennis Ruddy regarding Rationale and Conclusions Regarding Commenter-Identified Fossil Fuel Combustion Waste Damage Cases, April 20, 2000). Accessed Online October 2012.
EPA-HQ-RCRA-2006-0796-0070. This reference is the 2007 NODA’s Damage Case Assessment document. I.e., A.R.S. 49-241 et. Seq, administered by the ADEQ. Bluefish (N=12) in Cholla Lake had a dry-weight selenium tissue contents of 6.629 ± 0.679 µg/L vs. 3.91 ± 2.77 µg/L in Clear Creek Lake; and Channel Catfish (n=3) in Cholla Lake had a dry-weight selenium tissue contents of 5.164 ± 0.694 µg/L vs. 1.42 ± 0.070 µg/L in Clear Creek Lake (Shomo, 1991, Tables 10 and 12). Comment to the docket: EPA-HQ-RCRA-2009-0640-9337. As inferred from APS’ response in the NODA docket: EPA-HQ-RCRA-2006-0796-0070.
EPA (2007). IIa. CCR Damage Case Reassessment December 2014 http://www.regulations.gov/#!documentDetail;D=EPA-HQ-RCRA-2006-0796-0015 Cherry et al., (2000): Review of the Global Adverse Environmental Impacts to Ground Water and Aquatic Ecosystems from Coal Combustion Wastes. Donald S. Cherry, Rebecca J. Currie, and
David J. Soucek, Biology Department, Virginia Tech., Blacksburg, Virginia. Prepared for Hoosier Environmental Council and Citizens Coal Council, Indianapolis, Indiana, March 28, 2000. Accessed Online October 2012. http://www.citizenscoalcouncil.org/wp-content/uploads/2012/07/A-REVIEW-OF-THE-ADVERSEENVIRONMENTAL-IMPACTS-OF-COAL-COMBUS.htm
APS (2009): Arizona Public Service Company - Cholla Generating Station: Response to Request for Information Under l04(e) of the Comprehensive Environmental Response, Compensation, and Liability
GEI (2009): Coal Ash Impoundment Specific Site Assessment Report, Arizona Public Service, Cholla Power Plant Final report, GEI Consultants, December 2009. Accessed Online October 2012. http://www.epa.gov/waste/nonhaz/industrial/special/fossil/surveys2/apsc-cholla-final.pdf
USGS Professional Paper 1625-B (no Date): Geology and Coal Resources of the Upper Cretaceous Fruitland Formation, San Juan Basin, New Mexico and Colorado, James E. Fassett, Chapter Q of Geologic Assessment of Coal in the Colorado Plateau: Arizona, Colorado, New Mexico, and Utah. Edited by M.A. Kirschbaum, L.N.R. Roberts, and L.R.H. Biewick, U.S. Geological Survey Professional Paper 1625–B. Accessed Online January 2013. http://pubs.usgs.gov/pp/p1625b/Reports/Chapters/Chapter_Q.pdf McGavock (2012): Evolution of Groundwater Quality in the Southern Part of the Coconino Aquifer,
Arizona, an extended abstract, E.H. McGavock, Montgomery & Associates, Tucson, Arizona. Accessed Online January 2014. http://azhydrosoc.org/2012Symposium/docs/abstracts/2f_McGavock.pdf Bureau of Reclamation (2006): North Central Arizona Water Supply Study—Report of Findings. U.S. Department of the Interior, Bureau of Reclamation, Denver, Colorado, October 2006. Accessed Online January 2014. http://www.usbr.gov/lc/phoenix/reports/ncawss/NCAWSSP1NOAPP.pdf Shomo (1991): Biotic and Physico-Chemical Conditions in a Cooling Reservoir of a Coal-Fired Power
Plant, Shomo, Laurie Suzanne, Master Thesis, The University of Arizona, 1991. Accessed Online January 2014. http://arizona.openrepository.com/arizona/bitstream/10150/277958/1/azu_td_1345438_sip1_m.pdf Shomo and Maughan (1991): Cooling Reservoir of a Coal-Fired Power Plant as a Warmwater Fishery,
Laurie S. Shomo and O. Eugene Maughan, pp. 229-237 in Warmwater Fisheries, Symposium I (June 4-8, 1991), edited by James L. Cooper, R. H. Hamre, Scottsdale, Arizona, USDA Forest Service, Fort Collins,
Colorado, General Technical Report RM-207, 1991. Accessed Online January 2014. http://books.google.com/books?id=oAPy_2xYf_YC&pg=PA229&lpg=PA229&dq=Arizona+Public+Serv ice+Co.+Cholla+lake&source=bl&ots=Qybb9yqwlO&sig=ePdyLxIH7Sl5y2wsU9ICi39GD8&hl=en&sa=X&ei=IwzYUuSQOrXMsQSFpYHgDg&ved=0CC4Q6AEwAQ #v=onepage&q=Arizona%20Public%20Service%20Co.%20Cholla%20lake&f=false December 14, 2011 email from K. Morrison, EPA R8, to A. Livnat, EPA/OSWER. IIa. CCR Damage Case Reassessment December 2014 PTa04. Florida Power & Light Lansing Smith Plant, Bay County, Florida Type: Surface Impoundment. Background and Description: An unlined, 172-acre surface impoundment,59 constructed in 1965 at the Florida Power and Light Lansing Smith power plant in a coastal area60 about 15 miles north of Panama City, was first identified in the Arthur D. Little, Inc. (1985) study as cited in the 1988 Report to
SMCL, sodium at nearly 10 times the SMCL, and TDS at nine times the SMCL. According to Gulf Power (2009), the impoundment is divided into three cells: East Cell 79.2 – acres, Middle Cell - 35.4 acres, and Southwest Cell - 57.6 acres. The impoundment’s approximate Total Storage Capacity is 4,212,716 cubic yards. While subjected to the Dam Assessment survey, Southern Company and its subsidiary Gulf Power are claiming that the results of the survey contain “Confidential Business Information”. As of July 2014, while EPA is working to resolve these claims with the company, the reports are not posted (http://www.epa.gov/osw/nonhaz/industrial/special/fossil/surveys2/gulf_pclsp_southernco-cbi-comments.pdf). Today owned by Gulf Power. Gulf Power Company is an investor-owned electric utility with all of its common stock owned by Atlanta-based Southern Company. Four generation units have a total nameplate generating capacity of 890 MW. Bituminous coal is supplied from the Hobet Mine, a mountaintop removal coal mining operation in Boone County, West Virginia. The Lansing Smith Plant is located on Alligator Bayou off of North Bay in Bay County. http://www.gulfpower.com/about/plants.asp
EPRI (2010). Cited in EPA (2007). This decision was in accord with the scope of the 1993 Regulatory Determination, which addressed comanaged CCRs. Comment to the 2007 NODA docket: EPA-HQ-RCRA-2006-0796-0446.
FDEP, Solid Waste Section. Preliminary Evaluation of Analytical Data on Coal Combustion Products, (draft) March 18, 2008. IIa. CCR Damage Case Reassessment December 2014 Florida Power’s rebuttal 66 states that the alleged exceedances of radium 226 and 228 are the result of natural background conditions;67 and that the remaining alleged exceedances do not involve federal MCLs and were either the result of natural background conditions or were detected within the Zone of Discharge (ZOD), within which numerical primary and secondary drinking water standards do not apply.68 Florida’s Power & Light’s groundwater discharge permits were renewed by the FLDEP in 2004 after finding that the power plant was in compliance with all state regulations.
EPRI (2010),69 in its tabulation of exceedances in groundwater that is based on results presented in the 1988 Report to Congress claims that chromium, reported as a constituent of concern in the EPA (2007), had an MCL exceedance only in one out of 14 samples. Each of the other constituents associated with onsite impact: chloride, fluoride, iron, manganese, and sulfate, also had high concentrations in the seawater that was used for ash sluice make-up water. While representing a release from the ash pond, these constituents do not necessarily represent leaching of coal ash. Based on a few occurrences in upgradient wells,70 EPRI claims that cadmium concentrations were due to saltwater-induced mobilization of the cadmium present in sediments and geologic materials.
EPRI (2010). IIa. CCR Damage Case Reassessment December 2014 Basis for Consideration as a Potential Damage Case: This site has been reclassified as a potential damage case based on documented exceedances of primary drinking water standards for cadmium, chromium, and fluoride, and secondary drinking water standards for sulfate, chloride, manganese and iron in on-site ground water attributable to CCW. References
EPA (2007): 2007 Coal Combustion Waste Damage Case Assessments, Case #36 and reference therein (Compendium of nineteen alleged CCW damage cases, US EPA, May 3, 2007; Status of Alleged Damage Cases Submitted by the Hoosier Environmental Council, et. al., to Dennis Ruddy, February, 2002; Memorandum from SAIC to Dennis Ruddy regarding Rationale and Conclusions Regarding CommenterIdentified Fossil Fuel Combustion Waste Damage Cases, April 20, 2000). http://www.regulations.gov/#!documentDetail;D=EPA-HQ-RCRA-2006-0796-0015