AK Steel, Middletown, OH (AKS-Middletown-OH) BOF Vessel 15 Scrubber Stack Test 04/2-3/2007
Other documents for the same rulemaking
References: 3 extracted, 0 linked to papers
POSTTEST Reference Barometer Reading .2-9 •L Difference** 0 , o I, Date 3 6- 1 /07 ii. if fi Calibrator .74°) * Barometer is adjusted so that the difference does not exceed 0.05 in.Hg. ** Barometer is rig! adjusted_ If the difference exceeds 0.10 in.Hg, inform the project manager immediately. E-23 Title: E-2 Date: 8/7/03 Continuous Emission Monitor (CEM) Calibration Gases Calibration gases for CEMs are certified by the rnanufacturer to be within at least ±2 percent of the labeled values. Zero gases are generally certified to contain less than 0.5 ppm by volume of the particular gas being analyzed. Gas concentrations for the •cylinders used in this project are shown in the following Certificates of Analysis. Generic.applEnm F-7.4 Airgas Airgas Great Lakes, Inc. 2009 Bellaire Ave. Royal Oak, MI 48067 Ph: (248) 399-9150 Fax: (248) 584-2540 http://www.airgas.com Certificate of Analysis: EPA Protocol Gas Mixture Cylinder Number: CC239858 Reference Number: 32-112495158-1 Cylinder Pressure:• 2000.6 PSIG Expiration Date: 8/14/2009 Certification Date: 8/14/2006 Laboratory: M1C - Royal Oak - MI Certified Concentrations Component
CARBON MONOXIDE CARBON DIOXIDE OXYGEN 4 NITROGEN Concentration 2.000 % 9.820 % 12.55 % Balance Accuracy +/- 1% +I- 1% +1- 1% Analytical Principle Nondispersive Infrared (NDIR) Nondispersive Infrared (NDIR) Paramagnetic (Para) Procedure Certification performed in accordance with "EPA Traceability Protocol (Sept. 1997) using the assay procedures listed. Analytical tvlethodology does not require correction for analytical interferences. Notes: MIDDLETOWN Do not use cylinder below 150 psig. Approval Signature Reference Standard Information ap_t
CARBON MONOXIDE 2nd Component CARBON DIOXIDE 1st Analysis Date: 08/07/2006 Z 0.00 Conc 2.000 % R 0.985 Cone 2.000 % S 1.00 Cone 2.000 %