Weston Unit 4 PM CEMS Test Report
Other documents for the same rulemaking
References
NIST Traceable Thermometer Temp. (F) Working Thermocouple Temp. (F) 66.7 Reference Thermometer Temp. (F) Working Thermocouple Temp. (F) 70.2 Difference 0.00 0.13 0.00 Difference 0.00 -0.34 0.00 a (temp. diff.) = (ref.temp + 460) - (Thermo. temp. + 460) / (ref. temp. +460) x 100 Where -1.5 < a < 1.5 Signature Date 6/8/2022 119 of 127 MW023AS-013305-RT-1394 Pitot Tube Inspection Data Client Name: Pitot ID: AE5-6-22 Reference Thermometer: 210124988 Date: Pre-Test 1/5/2022 Date: Post-Test 6/8/2022
NIST Traceable Thermometer Temp. (F) Working Thermocouple Temp. (F) 63.1 Reference Thermometer Temp. (F) Working Thermocouple Temp. (F) 71.2 Difference 0.00 -0.36 0.00 Difference 0.00 -0.15 0.00 a (temp. diff.) = (ref.temp + 460) - (Thermo. temp. + 460) / (ref. temp. +460) x 100 Where -1.5 < a < 1.5 Signature Date 6/8/2022 120 of 127 MW023AS-013305-RT-1394
Appendix C.3 Accreditation Information/Certifications Wisconsin Public Service 2022 RCA Source Test Report, Weston Power Plant 121 of 127 MW023AS-013305-RT-1394 American Association for Laboratory Accreditation Accredited Air Emission Testing Body A2LA has accredited
ASTM D7036:2004 - Standard Practice for Competence of Air Emission Testing Bodies. Presented this 4th day of February 2022. _______________________ Vice President, Accreditation Services For the Accreditation Council Certificate Number 3925.01 Valid to February 29, 2024 This accreditation program is not included under the A2LA ILAC Mutual Recognition Arrangement. 122 of 127 MW023AS-013305-RT-1394 123 of 127 MW023AS-013305-RT-1394 124 of 127 MW023AS-013305-RT-1394
CERTIFICATE OF COMPLETION Paul Repuyan This document certifies that this individual has passed a comprehensive examination and is now a Qualified Individual (QI) as defined in Section 8.3 of ASTM D7036-04 for the following method(s): Source Evaluation Society Group 1: EPA Manual Gas Volume and Flow Measurements and Isokinetic Particulate Sampling Methods Certificate Number: 023-2021-37
DATE OF ISSUE: 01/03/2019 DATE OF EXPIRATION: 01/02/2024 125 of 127 MW023AS-013305-RT-1394 126 of 127 MW023AS-013305-RT-1394 This is the Last Page of This Document If you have any questions, please contact one of the following individuals by email or phone. Name: Title: Region: Email: Phone: Mr. Brandon Check Client Project Manager Midwest bcheck@montrose-env.com 630-860-4740 Name: Title: Region: Email: Phone: Mr. Steve Flaherty Midwest District Manager Midwest sflaherty@montrose-env.com 847-487-1580 Ext. 12417