Preamble Citations
Original sourcePDF at sourcePDF at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at source
Other documents for the same rulemaking (all, by stage)
References: 4,893 extracted, 1 linked to papers
ASHRAE prescribed ventilation Average of daily average (daily peak): 76 ppb (93 ppb) Calculated as mean indoor/daily average outdoor: daily average (daily peak): 0.13 (0.13) 1.2 L/s-m2 Volume-weighted concentrations Average of daily average (daily peak): 76 ppb (93 ppb) Calculated as mean indoor/daily average outdoor: daily average (daily peak): 0.079 (0.075) 0.4 L/s-m2 2-26 Table 2-4 (Continued): Summary of U.S. studies of ozone infiltration published after 2011. Reference Lai et al. (2015) Location West Lafayette, Time Period Ambient Ozone Population Microenvironment Concentration Test chamber I/O Ratio Correlation Infiltration 24.02– 53.5 ppb 0.050–0.099 Median (10th–90th percentile) 0.40 (0.15–0.85) Simple mechanical ventilation 38.96– 39.69 ppb 0.57–0.63 Median (10th–90th percentile) 0.98 (0.22–4.84)
Miami, FL; Data from Houston, TX; 2013 or
Sacramento, CA Ben-David and Waring (2018) Time Period January– February 2014 15 cities: 1999–2015
Detroit, MI February 2008–April 2009 U.S. EPA mild to Mean (SD): 3.4 ppb Mean (SD): severe, (3.6 ppb) 29.7 ppb nonsmoking adult (15.0 ppb) asthmatics and their environment study panel (N = 16) 0.0665 (slope) P/A: 0.27 Chen et al. (2012)
NMMAPS cities: 1987–2000 All residents Calculated change in total ozone exposure per unit change in ambient ozonea
Buffalo, NY 0.30 Chicago, IL 0.28 Cincinnati, OH 0.27 Corpus Christi, 0.28 Dallas/Ft. Worth, 0.27 2-31 Table 2-5 (Continued): Studies reporting relationships between personal ozone exposures and ambient ozone concentrations. Reference Chen et al. (2012) (continued) Jones et al. (2013) Location
Denver, CO Time Period 1987–2000 (continued) Population All residents (continued) Personal Concentration
Washington, DC 0.27 Worcester, MA 0.27 New York City, June 1– August 31, 2001–2005 Hospital admissions for respiratory diagnoses (N = 34,760 respiratory hospitalizations) Avg 8-h daily max (95th percentile): 12.78 ppb (20.78 ppb) Avg 8-h daily max: 30.67 ppb Mean (95th percentile): 0.48 (0.83) P/A: 0.979
SEARCH, U.S. EPA PAMS, U.S. EPA STN, IMPROVE monitoring networks L: In and near the Atlanta metropolitan area; T: Between the yr 1999 and 2007; P: Entire population considered Observed Long-term fixed-site exposure ambient monitors only, protocols of observed data were referenced in previous publications Mean summer quartiles of peak 8-h ozone in ppb, 44.85, 55.73, 64.93, 80.23 Observed Spatial data collected variability is directly; limited to speciation monitoring collected; locations several years of data collected Hackbarth et al. (2011) Daily 8-h max ozone within 20 miles of the zip-code centroid weighted by inverse distance from U.S. EPA's fixed-site monitors L: California; T: 2005– 2007; P: Those with
ER visits for cardio, resp, asthma Observed data Short-term used in exposure inverse-distance weighting validated from U.S. EPA Ozone daily avg in California between 2005 and 2007 because 37.1−73.8 ppb Observed data used directed with
FEM ambient 19, 2010; monitors (two P: Entire models: population Teledyne Model 211 and Teledyne Model 265E). The Teledyne Model 265E has since been certified as an FRM Comparison Short-term between exposure ambient monitor types using air spiked with known quantity of ozone 8-h daily max = avg 22 ppb, max 94 ppb, 19 values and 6 days with 8-h daily max above 75 ppb Average and maximum data compare well; frequent calibrations zero/span improved data quality Positive bias of FRM due to water vapor, gas-phase mercury, and VOCs Differences between monitors presented graphically but not reported Johnson et al. (2014)
FEM ambient L: Durham, monitor T: September 2012; P: Entire population Comparison with an FRM and a microenvironmental model 10-min avg value = 33.0−55.2 ppb Average values are only slightly higher than Potentially high positive errors in vicinity of VOC sources In the vicinity of VOC sources, ozone concentration from the FEM was several hundred percentage higher (depending on the source) than a microenvironmental monitor that compared well with the Short-term exposure 2-61 Table 2-8 (Continued): Studies informing assessment of exposure measurement error when concentrations measured by fixed-site monitors are used for exposure surrogates. Reference Buteau et al. (2017) Monitor Fixed-site monitors reporting data for 8-h daily Location, Time Period, Population L: Montreal, Quebec, Canada; T: January 1, 1991– December 31, 2002; P: Entire population Measurement Evaluation Technique Epidemiology Applications Comparison Short-term with BME, IDW, exposure and backextrapolation 2-62 Concentrations Measured 8-h daily max; mean (SD) = 27.9 ppb (15.2 ppb) median = 26.3 ppb Strengths Limitations Most accurate measure of ozone Lacks spatial resolution Exposure Measurement Errors
CAN; comparison to T: Winter fixed-site and summer, monitors 2005–2006; P: Adults and children with asthma Panel study Mean (SD) = 26 ppb (9 ppb); median = 25 ppb Can be used for personal, indoor, and outdoor sampling Bart et al. (2014) Gas sensitive semiconductor monitors L: Lower Fraser Valley, British Columbia, Canada; T: May– September 2012; P: Entire population Panel study
MB = −1 ppb SE = 6 ppb Table 2-9 (Continued): Studies informing assessment of exposure measurement error when concentrations measured by personal and microenvironmental monitors are used for exposure surrogates. Location, Time Period, Population Measurement Evaluation Technique Epidemiology Applications Concentrations Measured Reference Monitor Zimmerman et al. (2018) Low-cost sensor (Real-Time Affordable Multipollutant sensors) data filtered through model to improve data quality based on data across geographical area L: Pittsburgh, T: August 3, 2016– February 7, 2017; P: Carnegie Mellon University campus population Deployed a Short-term dense network of exposure low-cost samplers then applied one of two models (random forest or multiple linear regression) to smooth data for ozone 15-min avg time; NR Sagona et al. (2018) Personal ozone monitor operates by UV light absorption at 254 nm wavelength (2B Technologies) Piscataway, T: July 2014; P: Panel of volunteers Comparison of personal monitors with
IDW of data from 10 fixed-site monitors Location, Time Period, Population L: Atlanta, T: 2011; P: Entire population Measurement Evaluation Technique Comparison with fixed-site monitors Epidemiology Applications Short-term exposure Concentrations Measured 2-68 Strengths Better spatial resolution than monitor-based approaches Limitations Exposure Measurement Errors Quality of model Urban site: depends on spatial MB = −1.27 ppb, density of the
AQS; kriged surface is fit to high concentration monitors, low concentration monitors, randomly selected monitors, or all monitors Concentrations Measured Exposure Measurement Errors Strengths Limitations Mean (SD) for select hours 3/25/2012 2:00 p.m. = 68.2 ppb (6.15 ppb) 4/24/2012 2:00 p.m. = 65 ppb (6.32 ppb) 5/17/2012 2:00 p.m. = 72.7 ppb (10 ppb) 6/28/2012 3:00 p.m. =
BME-LUR hybrid model) Table 2-11 (Continued): Studies informing assessment of exposure measurement error when concentrations modeled by land use regression or spatiotemporal models are used for exposure surrogates. Reference Buteau et al. (2017) Model Land use regression with backextrapolation,
LUR model built from 76 monitors and included variables for land use and the built environment Location, Time Period, Population L: Montreal, Quebec, Canada; T: January 1, 1991– December 31, 2002; P: Entire population Measurement Evaluation Technique Epidemiology Applications Comparison with Short-term
MB = 5.6 ppb RMSE = 15.4 ppb; weekly MB = 9.2 ppb Adam-Poupart et al. (2014) Bayesian maximum entropy model with priors from land use regression L: Montreal, Quebec, Canada; T: May– September 1990–2009; P: Entire population Cross-validation Long-term against NAPS exposure monitoring data from 2005 When monitors are not clustered where people live, model quality is reduced R2 = 0.414,
RMSE = 9.164 ppb, percentage change in MSE = −23.0% 2-75 Accurate when monitoring stations clustered in study area Table 2-11 (Continued): Studies informing assessment of exposure measurement error when concentrations modeled by land use regression or spatiotemporal models are used for exposure surrogates. Reference Model Location, Time Period, Population Measurement Evaluation Technique Epidemiology Applications Concentrations Measured Strengths Limitations Exposure Measurement Errors Wang et al. (2016) SpatiotemporalL: Los
LUR incorporating Angeles and the UCD-CIT Riverside chemical Counties; transport model T: 2000– with meteorology 2008; modeled by WRF P: Entire v.3.1.1 on a 4-km population grid, ST-LUR alone 10-fold crossShort- and validation long-term against exposure 37 monitors for each variation of model 8-h daily max; range = 10−50 ppb (long-term avg) Improved integration of different models, takes advantage of spatial residuals Modeling
ST-LUR + CTM: daily max RMSE = 4.65 ppb, R2 = 0.87 Wang et al. (2015) Spatiotemporal model drawing from universal kriging, spatiotemporal trend, and spatiotemporal residuals 10-fold crossShort- and validation long-term against home exposure and AQS monitors in each city 2-week avg; NR Low spatial variability of ozone concentration across space allows this method to be more applicable Missing ozone data during cold seasons may limit the applicability of the model L: Baltimore, Chicago, Angeles, New York, St. Paul, WinstonSalem; T: 1993– 2013; P: MESA Air study participants 2-76 Overall crossvalidation MSE Baltimore = 0.90, Chicago = 0.71, Angeles = 0.67, New York = 0.60, St. Paul = 0.91, WinstonSalem = 0.66 Overall crossvalidation R2: Baltimore = 0.89, Chicago = 0.72, Angeles = 0.78, New York = 0.61,
PLS + UK summer = 0.71 winter = 0.58 Sahu and Bakar Bayesian (2012b) autoregressive models L: Eastern U.S.; T: 1997– 2006; P: Entire population Comparison of
Denver, Fort Collins, Yellowstone, Provo, Salt Lake City, Spokane); T: May to September for 2008 to 2015; P: Entire population Measurement Evaluation Technique Epidemiology Applications Model compared Short- and (and built) with long-term surface, exposure fixed-site monitoring data 2-79 Concentrations Measured Strengths 8-h daily max Multiple models used together ozone for (e.g., HYSPLIT Houston and HMS and between 0 and obs data) 120 ppb; Table 3: obs 8-h daily max ozone mean = 39.29 ppb, no smoke n = 1,082, smoke n = 41,
CONUS; T: January and July in 2002; P: Entire population Measurement Evaluation Technique
CMAQ 4.6 with nested grids (36 and 12 km) going down to 4-km grid size Location, Time Period, Population L: Southeast Texas; T: 3 weeks of hourly ozone between August 16 September 6, 2000; P: Entire population Measurement Evaluation Technique
GEOS-Chem 8-03-01 on a 2- × 2.5degree grid, CAMx 5.30 run on a 36-km and then 12-km grid size Location, Time Period, Population L: CONUS; T: Hourly ozone data for all of 2006; P: Entire population Measurement Evaluation Technique Comparison done between
GEOS-Chem and collocated observed data Epidemiology Applications Concentrations Measured Short- and long-term exposure Summer average for 2006; NR (shown graphically) 2-83 Strengths Two different modeling methods are compared and are both are compared to observed data Limitations Exposure Measurement Errors The coarse grid of R2 for
GEOS-Chem (OMI AK); (OMI AK) T: 8-h daily max from March–May 2006 compared with June– August 2006, with results displayed between 2006 and 2008; P: Entire population 2-84 Concentrations Measured
CHIMERE at a 0.25-degree horizontal resolution (note clear on the CHIMERE version) L: CONUS, Western Europe; T: Hourly ozone data for the entirety of 2006; P: Entire population
CONUS; T: Hourly ozone in July and August 2005; P: Entire population Measurement Evaluation Technique Epidemiology Applications Modeled output Short-term compared with exposure observed ozone data from AQS coming from fixed-site monitors;
DDM-3D L: Seattle, T: Hourly data for July 12–24, 2006; P: Entire population Measurement Evaluation Technique Epidemiology Applications
CMAQ 4.7 (2012) (continued) with 12-km horizontal resolution with nested 4-km grid in Seattle with a
DDM-3D (continued) Location, Time Period, Population L: Seattle, T: Hourly data for July 12–24, 2006; P: Entire population (continued) Measurement Evaluation Technique Epidemiology Applications
SMARTFIRE (2006), point sources from Continuous Emissions Monitoring data Location, Time Period, Population L: North America; T: Hourly ozone data from all of 2006; P: Entire population Measurement Evaluation Technique Comparison to observed fixed-site monitors Epidemiology Applications Concentrations Measured Short- and long-term exposure Summer 2006 daily ozone = between 20 and
Valley, CA and entire state of California; T: July 27– August 2, 2000; P: Entire population Measurement Evaluation Technique Compare model results from two photochemistry modules with concentrations from CARB observation sites Epidemiology Applications Concentrations Measured Short-term exposure Mapped concentrations from different emissions sources but did not tabulate 2-91 Strengths Limitations Study designed 4-km resolution to interpret not fine enough to different detect local emissions gradients and sources’ impacts small-scale variation in concentrations sources and to evaluate different model variations Exposure Measurement Errors
UCD-CIT model (continued) L: San Joaquin Valley, CA and entire state of California; T: July 27– August 2, 2000; P: Entire population (continued) Compare model results from two photochemistry modules with concentrations from CARB observation sites (continued) Liu and Zhang (2011)
NEI 3 L: CONUS; T: Hourly ozone from June 12–28 1999; P: Entire population Comparison of U.S. Short-term
CMAQ-Dust with incorporation ISORROPIA II, WRF 3.2, 1999 NEI 1 Location, Time Period, Population L: Global model; T: April 2001; P: Entire population Measurement Evaluation Technique Epidemiology Applications
NME = 25.5– 30.6%; ozone difference spatially = −1.5 to 1.5 ppb Table 2-12 (Continued): Studies informing assessment of exposure measurement error when concentrations modeled by chemical transport modeling are used for exposure surrogates. Reference Yu et al. (2012) Model
WRF 3.0) and WRF-NMM are compared Location, Time Period, Population L: Eastern U.S. with flight data over east Texas; T: Hourly data from August 1– October 15, 2006; P: Entire population Measurement Evaluation Technique Two different modeling methods were compared with observed data from U.S. EPA's fixed-site monitors and observed data from airplanes with flight paths and ship data in port Epidemiology Applications Concentrations Measured Short-term exposure 1 h for model
WRF 3.0) and WRF-NMM are compared (continued) L: Eastern U.S. with flight data over east Texas; T: Hourly data from August 1– October 15, 2006; P: Entire population (continued) Two different modeling methods were compared with observed data from U.S. EPA's fixed-site monitors and observed data from airplanes with flight paths and ship data in port (continued) Godowitch et al. (2011)
SMOKE 2.2 L: Eastern U.S.; T: June– August 2002 hourly ozone data; P: Entire population Compared with Short-term observed data from exposure U.S. EPA's CASTNet, observed data from flights taken in the afternoon of July 2002 2-95 Exposure Measurement Errors Strengths Limitations 1 h for model
Florida, Gulf Coast, Great Lakes Carlton and Baker CMAQ 4.7.1 (2011) 12-km horizontal resolution, AERO5, CB05, WRF 3.1, 2001 NEI 2 and BEIS 3.14 compared with
SMOKE 2.5, CMAQ 4.7.1 with 4-km horizontal resolution, model compared with MM5/CMAQ for 2001, model compared with
CALGRID and UAM for 1985 Location, Time Period, Population L: Metro Vancouver, Canada; T: July 19– 21, 1985, July 17–19, 1995, August 10– 12, 2001, June 24–26, 2006; P: Entire population Measurement Evaluation Technique Epidemiology Applications Models compared Short- and with each other, all long-term model compared exposure with historical surface, fixed-site monitors from Canada's NAPS, aloft observed data from aircraft in 1995 2-97 Concentrations Measured
CMAQ (NRC) for 2001 n = 1,717 (5,948), mean mod = 26.8 ppb (21.8 ppb), mean obs = 21.2 ppb (19.2 ppb); mean mod
SMOKE 2.2 L: Eastern U.S.; T: 2002 and 2006; P: Entire population Measurement Evaluation Technique Epidemiology Applications Observed data Long-term from surface exposure fixed-site monitors were compared with CMAQ; 2002 compared with 2006; NOX SIP Call region compared with data outside of
NOX SIP Call region 2-98 Concentrations Measured Only ozone differences are explored, and direct ozone concentrations are not explored Strengths Limitations There are multiple comparisons of this paper: modeled to observed, data from 2002 compared with 2006; ozone by percentage; inside NOX SIP Call area vs. outside The paper recognizes the issues of long-range transport of ozone Exposure
SIP call region: average change (2002−2006) in 8-h daily max = 66.7%, average percentage change in 8-h daily max = 69.7% Table 2-12 (Continued): Studies informing assessment of exposure measurement error when concentrations modeled by chemical transport modeling are used for exposure surrogates. Reference Model Location, Time Period, Population Measurement Evaluation Technique Epidemiology Applications Concentrations Measured Strengths Limitations Exposure Measurement Errors Appel et al. (2012) CMAQ 4.7.1 12-km horizontal resolution, met data from both