Preamble Citations
Original sourcePDF at sourcePDF at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at source
Other documents for the same rulemaking (all, by stage)
References: 4,893 extracted, 1 linked to papers
[3] National Energy Technology Laboratory, "Quality Guidelines for Energy System Studies: Specification for Selected Feedstocks," Department of Energy, Pittsburgh, 2019.
[4] National Energy Technology Laboratory, "Quality Guidelines for Energy System Studies: Cost Estimation Methodology for NETL Assessments of Power Plant Performance," Department of Energy, Pittsburgh, 2019.
[5] Environmental Protection Agency, "40 CFR Part 60 - Carbon Pollution Emissions Guidelines for Existing Stationary Sources: Electric Utility Generating Units; Final Rule Vol. 80 No. 205," 23 October 2015. [Online]. Available: https://www.gpo.gov/fdsys/pkg/FR-2015-10-23/pdf/2015-22842.pdf. [Accessed 9 October 2018].
[6] Environmental Protection Agency, "40 CFR Part 60: Review of Standards of Performance for Greenhouse Gas Emissions from New, Modified, and Reconstructed Stationary Sources: Electric Utility Generating Units Vol. 83 No. 244," 20 December 2018. [Online].
[7] National Energy Technology Laboratory, "Quality Guidelines for Energy System Studies: Process Modeling Design Parameters," Department of Energy, Pittsburgh, 2019.
[8] National Energy Technology Laboratory, "Quality Guidelines for Energy System Studies: Specification for Selected Feedstocks," Department of Energy, Pittsburgh, 2019.
[9] Gas Research Institute, Variability of Natural Gas Composition in Select Major Metropolitan Areas of the United States, Springfield: Department of Commerce, 1992.
[12] Environmental Protection Agency, "Review of New Sources and Modifications," 7 November 1986. [Online]. Available: https://www.ecfr.gov/current/title-40/chapterI/subchapter-C/part-51/subpart-I. [Accessed 31 March 2023].
[13] Environmental Protection Agency, "Map of Counties Designated "Nonattainment" for Clean Air Act's National Ambient Air Quality Standards (NAAQS)," 30 April 2018. [Online]. Available: https://www3.epa.gov/airquality/greenbook/map/mapnpoll.pdf. [Accessed 10 June 2019].
[14] Environmental Protection Agency, "40 CFR Part 423 Effluent Limitations Guidelines and Standards for the Steam Electric Power," 2019.
[15] Environmental Protection Agency, "National Pollutant Discharge Elimination System (NPDES)," [Online]. Available: https://www.epa.gov/npdes. [Accessed 13 July 2017].
[16] L. B. Davis and S. Black, "Dry Low NOx Combustions Systems for GE Heavy-Duty Gas Turbines," GE Power Systems, October 2000.
[17] GE Power, "7HA.01/.02 Gas Turbine," October 2015. [Online]. Available: https://www.ge.com/content/dam/gepowerpgdp/global/en_US/documents/product/gas%20turbines/Fact%20Sheet/7ha-factsheet-oct15.pdf. [Accessed 23 April 2021].
[18] Siemens Energy, "Gas turbines from 4 to 593 MW," 2019. [Online]. Available: https://assets.siemens-energy.com/siemens/assets/api/uuid:b86b3850-ef42-4c8da040-15866aa95f02/gas-turbines-siemens-int.pdf. [Accessed 23 April 2021].
[19] National Energy Technology Laboratory, "Quality Guidelines for Energy System Studies: Cost Estimation Methodology for NETL Assessments of Power Plant Performance," Department of Energy, Pittsburgh, 2019.
[20] Electric Power Research Institute, "Flexible Operation of Current and NextGeneration Fossil Plants With and Without Carbon Capture," EPRI, 2016.
[21] PJM, "Cost Development Subcommittee," 2 December 2021. [Online]. Available: https://www.pjm.com/-/media/committeesgroups/subcommittees/cds/2021/20211202/20211202-item-06-start-cost-alternateproposal.ashx. [Accessed 10 March 2023].
[22] ANSI/IEEE, "762-2006 - IEEE Standard Definitions for Use in Reporting Electric Generating Unit Reliability, Availability, and Productivity," ANSI/IEEE, 29 March 2012. [Online]. Available: https://ieeexplore.ieee.org/document/4135890. [Accessed January 2019].
[23] North American Electric Reliability Corporation, "Generating Availability Data System (GADS)," North American Electric Reliability Corporation, 2017. [Online]. Available: https://www.nerc.com/pa/RAPA/gads/Pages/GeneratingAvailabilityDataSystem(GADS).aspx. [Accessed January 2019].
[24] GE Power, "LM6000 Power Plants," April 2021. [Online]. Available: https://www.ge.com/content/dam/gepower-new/global/en_US/downloads/gas-
GAS ELECTRICITY GENERATING UNITS FOR FLEXIBLE OPERATION new-site/products/gas-turbines/lm6000-fact-sheet-product-specifications.pdf. [Accessed 23 April 2021].
[25] National Energy Technology Laboratory, "Cost and Performance Baseline For Fossil Energy Plants Volume 1: Bituminous Coal and Natural Gas to Electricity," Department of Energy, Pittsburgh, 2019.
[26] Gas Research Institute, Variability of Natural Gas Composition in Select Major Metropolitan Areas of the United States, Springfield: U.S. Department of Commerce, 1992.
[28] Energy Information Amdinstration, "Natural Gas Spot and Future Prices," [Online]. Available: https://www.eia.gov/dnav/ng/ng_pri_fut_s1_d.htm. [Accessed June 2022].
APPENDIX: STARTS-BASED O&M COSTS Starts-based operation and maintenance (O&M) costs are provided for cases CC1A-F, CC1A-H, CC2A-F, CC2A-FC, and CC2A-H in Exhibit A-1 through Exhibit A-5. Exhibit A-1. Case CC1A-F initial and annual O&M costs (starts-based) Case: CC1A-F – NGCC F-Class (1x1) Plant Size (MW, gross): 369 Cost Base: Dec 2018 Heat Rate-net (Btu/kWh): 6,461 Capacity Factor (%): 25 Operating & Maintenance Labor Operating Labor Operating Labor Requirements per Shift Operating Labor Rate (base): 38.50 $/hour Operating Labor Burden: 30.00 % of base Labor O-H Charge Rate: 25.00 % of labor Skilled Operator: Operator: Foreman: Starts Per Year: 365 #/year Lab Techs, etc.: Cost Per Start: 14,000 $/start Total: Fixed Operating Costs Annual Cost ($) Annual Operating Labor: $1,753,752 Maintenance Labor: $2,044,000 Administrative & Support Labor: $949,438 Property Taxes and Insurance: $6,337,140 Total: $11,084,337 Variable Operating Costs Annual Cost ($) Maintenance Material: $3,066,000 Consumables Initial Fill Per Day Per Unit Initial Fill Annual Cost ($) Water (gal/1000):
Sacks, J. D.; Lloyd, J. M.; Zhu, Y.; Anderton, J.; Jang, C. J.; Hubbell, B.; Fann, N. The Environmental Benefits Mapping and Analysis Program – Community Edition (BenMAP–CE): A Tool to Estimate the Health and Economic Benefits of Reducing Air Pollution. Environmental Modelling and Software 2018, 104. https://doi.org/10.1016/j.envsoft.2018.02.009. U.S. EPA-SAB. 2011.Review of: Valuing Mortality Risk Reductions for Environmental Policy: A White Paper;
Washington, D.C.. U.S. EPA. 2016. Guidelines for Preparing Economic Analyses; Washington, DC. U.S. EPA. 2017. 2017 National Emission Inventory Based Photochemical Modeling for Sector Specific Air Quality Assessments; Research Triangle Park, NC, 2021. U.S. EPA. 2018. User Manual for Environmental Benefits Mapping and Analysis Program (BenMAP); Research Triangle Park, NC, 2018. U.S. EPA. Technical Support Document Estimating the Benefit per Ton of Reducing PM 2 . 5 Precursors from 17 Sectors. 2018, No. January, 1–107. U.S. EPA. 2023. Regulatory Impact Analysis for the Proposed National Emission Standards for Hazardous Air Pollutants: Coal- and Oil-Fired Electric Utility Steam Generating Units Review of the Residual Risk and Technology Review; Research Triangle Park, NC, 2023. EPA-452/R-23-002 U.S. EPA. Estimating the Benefit per Ton of Reducing Directly-Emitted PM2.5, PM2.5 Precursors and Ozone Precursors from 21 Sectors.. https://www.epa.gov/system/files/documents/202110/source-apportionment-tsd-oct-2021_0.pdf (accessed 06/26/2024) U.S. EPA. 2023. Estimating PM 2.5-and Ozone-Attributable Health Benefits;. https://www.epa.gov/benmap/estimating-benefit-ton-reducing-directly-emitted-pm25-pm25precursors-and-ozone-precursors U.S. EPA. 2024. Estimating PM 2.5-and Ozone-Attributable Health Benefits: 2024 Update;. https://www.epa.gov/benmap/estimating-benefit-ton-reducing-directly-emitted-pm25-pm25precursors-and-ozone-precursors
EPA to continue evolving its reporting systems to take advantage of new technology and improve transparency for all our stakeholders. More details on implementation of the attached Policy Statement will be set forth in internal implementing guidance from the Office of Policy in October 2013 . Attachment cc: EPA Internal E-Enterprise Management Team.
EPA's Final Plan for Periodic Retrospective Reviews. August 2011 (p. 6) http://www.whitehouse.gov/sites/default/files/omb/egov/digital-govemment/digital-govemment-strategv.pdf Policy Statement on E-Reporting in EPA Regulations September 30, 2013 The Policy of the U.S. Environmental Protection Agency (EPA) is to: 1. Begin the regulatory development process with the assumption that all reporting will be electronic, unless there is a compelling reason to use paper reporting;
2. Camacho, E.F.; Samad, T.; Garcia-Sanz, M.; Hiskens, I. Control for Renewable Energy and Smart Grids. In The Impact of Control Technology; Samad, T., Annaswamy, A.M., Eds.; IEEE Control Systems Society: New York, NY, USA, 2011; pp. 69–88.
Bologna, Italy, 23–26 June 2003. 5. Lalor, G.; Ritchie, J.; Flynn, D.; O’Malley, M.J. The impact of combined-cycle gas turbine short term dynamics on frequency control. IEEE Trans. Power Syst. 2005, 20, 1456–1464.
UK, 2006. 7. Rice, I.G. Steam-Injected Gas Turbine Analysis—Part I—Steam Rates. In Proceedings of the International Gas Turbine and Aeroengine Congress and Exposition, Cincinnati, OH, USA, 24–27 May 1993.
8. Kehlhofer, R.; Rukes, B.; Hannemann, F.; Stirnimann, F. Combined-Cycle Gas & Steam Turbine Power Plants; PennWell Corporation: Tulsa, OK, USA, 2009.
9. Jonsson, M.; Yan, J. Humidified gas turbines—A review of proposed and implemented cycles. Energy 2005, 30, 1013–1078.
10. Rowen, W.I. Simplified mathematical representations of heavy-duty gas turbines. J. Eng. Gas Turbines Power 1983, 105, 865–869.
11. Bahrami, S.; Ghaffari, A.; Thern, M. Improving the transient performance of the gas turbine by steam injection during frequency dips. Energies 2013, 6, 5283–5296. © 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/).
EPA/600/R-20/012 | April 2020| www.epa.gov/isa Integrated Science Assessment for Ozone and Related Photochemical Oxidants Office of Research and Development Center for Public Health & Environmental Assessment, Research Triangle Park, NC
EPA/600/R-20/012 April 2020 www.epa.gov/isa Integrated Science Assessment for Ozone and Related Photochemical Oxidants April 2020 Contains Errata Sheet created September 2021 Center for Public Health and Environmental Assessment Office of Research and Development U.S. Environmental Protection Agency Research Triangle Park, NC Disclaimer This document has been reviewed in accordance with the U.S. Environmental Protection Agency policy and approved for publication. Mention of trade names or commercial products does not constitute endorsement or recommendation for use. Contents
Adams, WC. (2002). Comparison of chamber and face-mask 6.6-hour exposures to ozone on pulmonary function and symptoms responses. Inhal Toxicol 14: 745-764. http://dx.doi.org/10.1080/08958370290084610
Adams, WC. (2003). Comparison of chamber and face mask 6.6-hour exposure to 0.08 ppm ozone via square-wave and triangular profiles on pulmonary responses. Inhal Toxicol 15: 265-281. http://dx.doi.org/10.1080/08958370390168283
Adams, WC. (2006). Comparison of chamber 6.6-h exposures to 0.04-0.08 ppm ozone via squarewave and triangular profiles on pulmonary responses. Inhal Toxicol 18: 127-136. http://dx.doi.org/10.1080/08958370500306107
Brown, JS; Bateson, TF; Mcdonnell, WF. (2008). Effects of exposure to 0.06 ppm ozone on FEV1 in humans: A secondary analysis of existing data. Environ Health Perspect 116: 1023-1026. http://dx.doi.org/10.1289/ehp.11396
Horstman, DH; Folinsbee, LJ; Ives, PJ; Abdul-Salaam, S; Mcdonnell, WF. (1990). Ozone concentration and pulmonary response relationships for 6.6-hour exposures with five hours of moderate exercise to 0.08, 0.10, and 0.12 ppm. Am J Respir Crit Care Med 142: 1158-1163. http://dx.doi.org/10.1164/ajrccm/142.5.1158
RB; Peden, DB; Diaz-Sanchez, D. (2011). Lung function and inflammatory responses in healthy young adults exposed to 0.06 ppm ozone for 6.6 hours. Am J Respir Crit Care Med 183: 12151221. http://dx.doi.org/10.1164/rccm.201011-1813OC
Horstman, DH. (1991). Respiratory response of humans exposed to low levels of ozone for 6.6 hours. Arch Environ Occup Health 46: 145-150. http://dx.doi.org/10.1080/00039896.1991.9937441
McDonnell, WF; Stewart, PW; Smith, MV. (2013). Ozone exposure-response model for lung function changes: An alternate variability structure. Inhal Toxicol 25: 348-353. http://dx.doi.org/10.3109/08958378.2013.790523
McDonnell, WF; Stewart, PW; Smith, MV; Kim, CS; Schelegle, ES. (2012). Prediction of lung function response for populations exposed to a wide range of ozone conditions. Inhal Toxicol 24: 619-633. http://dx.doi.org/10.3109/08958378.2012.705919
Yu, H; Yu, F; Yoon, JH; Zhang, K; Zhang, H; Zhou, C. (2013). Radiative forcing of the direct aerosol effect from AeroCom Phase II simulations. Atmos Chem Phys 13: 1853-1877. http://dx.doi.org/10.5194/acp-13-1853-2013
Schelegle, ES; Morales, CA; Walby, WF; Marion, S; Allen, RP. (2009). 6.6-hour inhalation of ozone concentrations from 60 to 87 parts per billion in healthy humans. Am J Respir Crit Care Med 180: 265-272. http://dx.doi.org/10.1164/rccm.200809-1484OC U.S. EPA (U.S. Environmental Protection Agency). (2013). Integrated science assessment for ozone and related photochemical oxidants [EPA Report]. (EPA/600/R-10/076F). Research Triangle Park,
Abatzoglou, JT; Kolden, CA; Balch, JK; Bradley, BA. (2016). Controls on interannual variability in lightning-caused fire activity in the western US [Letter]. Environ Res Lett 11. http://dx.doi.org/10.1088/1748-9326/11/4/045005