Reference 21 Block Stimuli to the Revision Process Modernization of Asbestos Testing in Talc USP PF 40 4 2014
Other documents for the same rulemaking (all, by stage)
References: 435 extracted, 0 linked to papers
2. Damgaard R, Rasmussen M, Buus P, Mulhall B, Guazzo D, High-voltage leak detection of a parenteral proteinaceous solution product packaged in form-fill-seal plastic laminate bags. Part 1. Method development and validation. PDA J Pharm Sci Technol. 2013;67(6):634–651. 3. Möll F, Doyle DL, Haerer M, Guazzo DM. Validation of a high voltage leak detector for use with pharmaceutical blow-fill-seal containers–a practical approach. PDA J Pharm Sci
Technol. 1998;52(5):215–227. 4. Rasmussen M, Damgaard R, Buus P, Mulhall B, Guazzo DM. High-voltage leak detection of a parenteral proteinaceous solution product packaged in form-fill-seal plastic laminate bags. Part 2. Method performance as a function of heat seal defects, product-package refrigeration, and package plastic laminate lot. PDA J Pharm Sci Technol. 2013;67(6):652–663.
5. Rasmussen M, Damgaard R, Buus P, Guazzo DM. High-voltage leak detection of a parenteral proteinaceous solution product packaged in form-fill-seal plastic laminate bags. Part 3. Chemical stability and visual appearance of a protein-based aqueous solution for injection as a function of HVLD exposure. PDA J Pharm Sci Technol. 2013;67(6):664–669.
Sci Technol. 2012;66(5):434–444. 7. Lin TP, Hsu CC, Kabakoff BD, Patapoff TW. Application of frequency-modulated spectroscopy in vacuum seal integrity testing of lyophilized biological products. PDA J
Pharm Sci Technol. 2004;58(2):106–115. 8. Cook IA, Ward KR. Applications of headspace moisture analysis for investigating the water dynamics within a sealed vial containing freeze-dried material. PDA J Pharm Sci
Technol. 2011;65(1):2–11. 9. Zuleger B, Werner U, Kort A, Glowienka R, Wehnes E, Duncan D. Container/closure integrity testing and the identification of a suitable vial/stopper combination for lowtemperature storage at 80 C. PDA J Pharm Sci Technol. 2012;66(5):453–465. 10. Yoon S-Y, Sagi H, Goldhammer C, Li L. Mass extraction container closure integrity physical testing method development for parenteral container closure systems. PDA J
Pharm Sci Technol. 2012;66(5):403–419. 11. ASTM F2095. Standard test methods for pressure decay leak test for flexible packages with and without restraining plates. West Conshohocken, PA: ASTM International; 2013.
PF 40(5): Sep.-Oct. 2014 Theory and practical example. PDA J Pharm Sci Technol. 2010:64(1):71–79.
13. ASTM F2391. Standard test method for measuring package and seal integrity using helium as the tracer gas. West Conshohocken, PA: ASTM International; 2005.
14. ASTM F2338. Standard test method for nondestructive detection of leaks in packages by vacuum decay method. West Conshohocken, PA: ASTM International; 2013.
15. ASTM F2096. Standard test method for detecting gross leaks in medical packaging by internal pressurization (bubble test). West Conshohocken, PA: ASTM International; 2011.
16. ASTM D3078. Standard test method for determination of leaks in flexible packaging by bubble emission. West Conshohocken, PA: ASTM International; 2013.
17. ASTM D6653/D6653M. Standard test methods for determining the effects of high altitude on packaging systems by vacuum method. West Conshohocken, PA: ASTM International; 2013.
18. ASTM F2391. Standard test method for measuring package and seal integrity using helium as the tracer gas. West Conshohocken, PA: ASTM International; 2011.
19. ASTM F1929. Standard test method for detecting seal leaks in porous medical packaging by dye penetration. West Conshohocken, PA: ASTM International; 2012.
Technol. 2000;54(6):449–455. 21. Wolf H, Stauffer T, Chen S-C Y, Lee Y, Forster R, Ludzinski M, Kamat M, Mulhall B,
Guazzo D. Vacuum decay container/closure integrity testing technology. Part 2. Comparison to dye ingress tests. PDA J Pharm Sci Technol. 2009;63(5):489–498.
22. Jacobus RH, Torralba P, Moldenhauer J, Scheidt WC, Runkle JA. Development and validation of a spectrophotometric dye immersion test method used to measure container-closure integrity of an oil-based product. PDA J Pharm Sci Technol. 1998;52(3):110–112. 2S (USP38)
BRIEFING 1207.3 Package Seal Quality Test Methods. This proposed new general information chapter summarizes test methods useful for characterizing and monitoring package seal quality. These methods are not leak tests but provide additional data regarding package seal characteristics that may affect package integrity and leakage. The purpose of this chapter is to provide information to guide the selection and use of package seal quality test technologies. Chapter 1207.3 is part of a set of related chapters; for additional information, refer to the Briefing for Sterile Product Packaging—Integrity Evaluation (GCM: R. Tirumalai.) Correspondence Number—C147438 Comment deadline: November 30, 2014 Add the following: 1207.3
PACKAGE SEAL QUALITY TEST METHODS 1207 . PF 40(5): Sep.-Oct. 2014
1. ASTM D2063/D2063M. Standard test methods for measurement of torque retention for packages with continuous thread closures using non-automated (manual) torque testing equipment. West Conshohocken, PA: ASTM International; 2012.
2. ASTM D3198. Standard test method for application and removal torque of threaded or lug-style closures. West Conshohocken, PA: ASTM International; 2007.
3. ASTM D3469. Standard test methods for measurement of vertical downward forces to disengage type IIA lug-style child-resistant closures. West Conshohocken, PA: ASTM International; 2007.
IIA child-resistant closures. West Conshohocken, PA: ASTM International; 2007.
5. ASTM D3472. Standard test method for reverse-ratchet torque of type IA childresistant closures. West Conshohocken, PA: ASTM International; 2007.
6. ASTM D3810. Standard test method for minimum application torque of type IA childresistant closures. West Conshohocken, PA: ASTM International; 2007.
7. ASTM D3968. Standard test method for monitoring of rotational torque of type IIIA child-resistant closures. West Conshohocken, PA: ASTM International; 2007.
8. ASTM F2054/F2054M. Standard test method for burst testing of flexible package seals using internal air pressurization within restraining plates. West Conshohocken, PA: ASTM International; 2014.
10. ASTM F88/F88M. Standard test method for seal strength of flexible barrier materials. West Conshohocken, PA: ASTM International; 2009.
11. Ludwig JD, Nolan PD, Davis CW. Automated method for determining Instron residual seal force of glass vial/rubber stopper closure systems. PDA J Pharm Sci Technol. 1993;47(5):211–253.
12. Ludwig JD, Davis CW. Automated method for determining Instron residual seal force of glass vial/rubber closure systems. Part II. 13 mm vials. PDA J Pharm Sci Technol. 1995;49(5):253–256.
13. Morton DK, Lordi NG. Residual seal force measurement of parenteral vials. I. Methodology. J Parenteral Sci Technol. 1988;42(1):23–29.
14. Morton DK, Lordi NG. Residual seal force measurement of parenteral vials. II. Elastomer evaluation. J Parenteral Sci Technol. 1988;42(2):57–61.
15. ASTM F3004. Standard test method for evaluation of seal quality and integrity using airborne ultrasound. West Conshohocken, PA: ASTM International; 2013. 2S (USP38)
PF 40(5): Sep.-Oct. 2014 to Validation of Compendial Procedures 1225 with the purpose of providing statistical methods that can be used in the validation of analytical procedures. Specifically, this chapter discusses all of the following analytical performance characteristics from a statistical perspective: accuracy, precision, range, detection limit, quantitation limit, and linearity. Additional related topics that are discussed in this proposed new chapter include statistical power, two one-sided test (TOST) of statistical equivalence, tolerance intervals, prediction intervals, corrected Akaike Information Criterion (AICc), Bayesian analysis, experimental design, calibration, and variance pooling strategy. (STAT: H. Pappa.) Correspondence Number—C135740 Comment deadline: November 30, 2014 Add the following: 1210
PF 40(5): Sep.-Oct. 2014 6.2 Reasons for Studying the Calibration Relationship 6.3 Current Practice 6.4 Calibration Model Definition 6.5 Methods for the Assessment of Linearity 6.6 Methodological Assumptions 6.7 Two One-Sided Tests of Equivalence to Evaluate Bias in Reported Concentrations 6.7.1 TOST for Bias When Approximating a Quadratic with a Straight-Line Model 6.7.2 TOST for Bias When Approximating a Straight-Line Model with a Proportional Model 6.8 Corrected Akaike Information Criterion for Model Selection 6.9 Examples 6.9.1 TOST and AICc Comparison of Quadratic and Straight Line Models 6.9.2 TOST and AICc Comparison of Straight-Line and Proportional Models 7. Appendix 8. References
Assoc.1952;47:583–621. 2. Levene H. Robust tests for equality of variances. In: Contributions to probability and statistics: essays in honor of Harold Hotelling. Palo Alto, CA: Stanford University Press; 1960. p 278–292.
3. Bartlett MS. Properties of sufficiency and statistical tests. Proceed R Stat Soc Lond A. 1937;160(901):268–282.
Biometrika. 1965;52(3-4):591–611. 5. Barnett V, Lewis T. Outliers in statistical data. In: Wiley series in probability and mathematical statistics. 3rd ed. New York: John Wiley & Sons; 1994.
6. JCGM member organizations (BIPM, IEC, IFCC, ILAC, ISO, IUPAC, IUPAP, and OIML). International vocabulary of metrology—basic and general concepts and associated terms (VIM). 3rd ed. Geneva: JCGM; 200:2012.
7. Graybill FA, Wang CM. Confidence intervals on nonnegative linear combinations of variances. J Am Stat Assoc. 1980;75:869–873.
Biopharmaceut. 1987;15(6):657–680. 10. Hubert P, Nguyen-Huu JJ, Boulanger B, et al. Harmonization of strategies for the validation of quantitative analytical procedures. A SFSTP proposal—part I. J Pharm
Biomed Anal. 2004;36(3):579–586. 11. Hubert P, Nguyen-Huu JJ, Boulanger B, et al. Harmonization of strategies for the
PF 40(5): Sep.-Oct. 2014 validation of quantitative analytical procedures. A SFSTP proposal—part II. J Pharm
Biomed Anal. 2007;45(1):70–81. 12. Hubert P, Nguyen-Huu JJ, Boulanger B, et al. Harmonization of strategies for the validation of quantitative analytical procedures. A SFSTP proposal—part III. J Pharm
Biomed Anal. 2007;45(1):82–96. 13. Mee RW. Beta-expectation and beta-content tolerance limits for balanced one-way
ANOVA random model. Technometrics. 1984;26(3):251–254.
14. Hahn GJ, Meeker WQ. Statistical intervals: a guide for practitioners. New York: John Wiley & Sons;1991. p. 412.
15. Hoffman D, Kringle R. A total error approach for the validation of quantitative analytical methods. Pharm Res. 2007;24(6):1157–1164.
16. Wolfinger RD. Tolerance intervals for variance component models using Bayesian simulation. J Quality Technol. 1998;30(1):18–32.