Reference 13 IWGACP Appendices to White Paper January 13 2022
Other documents for the same rulemaking (all, by stage)
References
FR 24310; June 8, 1992). The MSHA asbestos PEL for miners is 0.1 fibers/cc over 8 hours (defined similarly to
ISO 17025), use of established (published) methods, and participation in proficiency testing using well-characterized materials are beneficial toward ensuring the reliability of the asbestos analysis. 1. Qualifications of a Laboratory for Detecting Asbestos in Talc In response to the February 4, 2020 Public Meeting on Testing Methods for Asbestos in Talc and Cosmetic Products Containing Talc a docket 26 contained comments suggesting that insufficient analyst education in mineralogy may lead to inaccurate reports of asbestos due to mischaracterization of minerals. The IWGACP agrees that certain qualifications are necessary and that only competent individuals trained in mineral detection and identification should be conducting analysis of talc and cosmetics for asbestos minerals. However, the IWGACP concludes that an advanced degree in mineralogy is not a prerequisite for individuals conducting asbestos analysis routinely in commercial, industry, or government laboratories.
Institute, AIHA, and U.S. government labs, such as USGS and NIST. Organizations that accredit a laboratory for measurement of asbestos include, but are not limited to, NIST National Voluntary Laboratory Accreditation Program (NVLAP), American Industrial Hygiene Association’s Laboratory Accreditation Program (AIHA-LAP), and The NELAC Institute (TNI) (National Environmental Laboratory Accreditation Conference). December 2021 management, and independent oversight are essential elements of a standardized approach to testing cosmetics for asbestos. December 2021
TEM, and SEM should remain unground or un-milled to retain original particle dimensions and shapes. Aliquots supplied for PLM, TEM, and SEM should be of sufficient mass to allow replicate analyses and archiving. Laboratories should ensure the sample preparation methods have negligible effects on the dimensions of any particles present. Regardless of the sample preparation method (e.g., removing moisture and organics, mixing/homogenization, dissolution), any change in sample weight between each of the steps in the procedure must be measured and recorded (weight accountability). Standard gravimetric procedures for preparing other bulk materials for asbestos analysis by optical and electron microscopy may be applicable and should be consulted when using gravimetric procedures to prepare talc and talc-containing cosmetic samples (e.g., ISO 11358-1:2014; ISO/IEC 17025:2017; ASTM E2402-11 (2017); CTFA E36-1; ASTM E11131-20; USP<731>;
Assuncao, J. and Corn, M. 1975. The effects of milling on diameters and lengths of fibrous glass and chrysotile asbestiform fibers. Am. Ind. Hyg. Assoc. J. 36(11): 811-819
ASTM E2402-11. 2017. Standard test method for mass loss and residual measurement validation of thermogravimetric analyzers. American Society for Testing and Materials International (ASTM). West Conshohocken, PA: ASTM International.
ASTM E1131-20. 2020. Standard test method for compositional analysis by thermogravimetry. American Society for Testing and Materials International (ASTM). West Conshohocken, PA:
ASTM International. California Environmental Protection Agency: Air Resources Board. 1991. Method 435: determination of asbestos content of serpentine aggregate. https://ww3.arb.ca.gov/testmeth/vol3/m_435.pdf (last accessed 11/13/20).
Cosmetic, Toiletry. and Fragrance Association (CTFA) Method E36-1. 1990. Ash or loss on ignition of talc. In Compendium of Cosmetic Ingredient Composition: Methods, Section E.
CTFA, currently known as the Personal Care Products Council (PCPC), Washington DC (released 1976; revised 1990). Interstate Technology & Regulatory Council. Incremental Sampling Methodology. https://www.itrcweb.org/Team/Public?teamID=11 (last accessed 12/31/2020)
ISO 10725:2000(E). International Organization for Standardization (ISO). Acceptance sampling plans and procedures for the inspection of bulk materials. https://www.iso.org/standard/33418.html (last accessed 12/31/2020)
ISO 11358-1:2014. International Organization for Standardization (ISO). Thermogravimetry (TG) of polymers–Part 1: General Principles. https://www.iso.org/standard/59710.html (accessed 11/2/20). December 2021
ISO 11648-1:2003. International Organization for Standardization (ISO). Statistical aspects of sampling from bulk materials – Part 1: General principles. https://www.iso.org/standard/33484.html (last accessed 12/31/2020)
ISO 11648-2:2001. International Organization for Standardization (ISO). Statistical aspects of sampling from bulk materials – Part 2: Sampling of particulate materials. https://www.iso.org/standard/23663.html (last accessed 12/31/2020)
ISO 14488:2007. International Organization for Standardization (ISO). Particulate materials – Sampling and sample splitting for the determination of particulate properties. https://www.iso.org/standard/39988.html (last accessed 12/31/2020)
ISO/IEC 17025:2017. International Organization for Standardization (ISO). Testing and calibration laboratories. https://www.iso.org/ISO-IEC-17025-testing-and-calibrationlaboratories.html (last accessed 12/31/2020)
Jozanikohan, G. F. Sahabi, G.H. Norouzi, H. Memarian. 2015. Thermal analysis: A complementary method to study the Shurijeh clay minerals. Int. J. Min. Geo-Eng. (49): 33-45.
Langer, A.M., Wolff, M.S., Rohl, A.N., Selikoff, I.J. 1978. Variation of properties of chrysotile asbestos subjected to milling. J. Tox. Env. Health 4(1):173-188.
Mackenzie, R.C. and Caillere, S. 1975. The thermal characteristics of soil minerals and the use of these characteristics in the qualitative and quantitative determination of clay minerals in soils. In: Soil Components. Gieseking, J.E., Ed. Springer: Berlin, Heidelberg. 529-571.
Petersen, L., Minkkinen, P., Esbensen, K.H. 2005. Representative sampling for reliable data analysis: Theory of Sampling. In Chemometrics Intell. Lab. Syst. 77(1-2): 261-277 at https://doi.org/10.1016/j.chemolab.2004.09.013 (Date accessed 11/4/2020).
Pooler, P.S., Goodrum, P.E.,Crumbling, D., Stuchal, L.D., Roberts, S.M. 2018. Incremental sampling methodology: applications for background screening assessments. Risk Anal.38(1):194209.
Willenbring, J.K. 2016. Asbestos fiber preparation methods affect fiber toxicity. Environ. Sci. Technol. Lett. 3(7):270-274.
USBM IC 9431. 1995. US Bureau of Mines. Laboratory Procedures for HydrometallurgicalProcessing and Waste-Management Experiments Section 2.4. https://ntrl.ntis.gov/NTRL/dashboard/searchResults.xhtml
USP 43-NF 38 <731>. 2020. United States Pharmacopeia and National Formulary. General Chapter: <731> Loss on drying. Rockville, MD: United States Pharmacopeial Convention. Current: Feb 1, 2020. https://online.uspnf.com/uspnf/document/1_GUID-1879E874-892E-4CB3A77A-ED3736B722C4_2_en-US?source= December 2021
USP 43-NF 38 <733>. 2020. United States Pharmacopeia and National Formulary. General Chapter: <733> Loss on ignition. Rockville, MD: United States Pharmacopeial Convention. Current: Feb 1, 2020. https://online.uspnf.com/uspnf/document/1_GUID-1879E874-892E-4CB3A77A-ED3736B722C4_2_en-US?source=
USP 43-NF 38 <1097>. 2020. United States Pharmacopeia and National Formulary. General Chapter: <1097> Bulk Powder Sampling Procedures. [gives an in-depth treatment of powder sampling theory and practice]. Rockville, MD: United States Pharmacopeial Convention. Current: Feb 1, 2020.
Wroble, J., Frederick, T., Frame, A., Vallero, D. 2017. Comparison of soil sampling and analytical method for asbestos at the Sumas Mountain Asbestos Site – Working towards a toolbox for better assessment. PloS ONE 12(7): e0180210. https://doi.org/10.1371/journal.pone.0180210 December 2021
Ates, 2010; Kursun, 2011; Divya et al., 2017). Despite the numerous methods and publications on beneficiation of talc and other minerals, the
LLC., under contract with the Idaho National Laboratory (INL) developed an advanced method using air-elutriation to preferentially elutriate asbestos fibers from vibrating soil (Januch et al., 2013). The FBAS is used as a sample preparation instrument that utilizes air elutriation to separate light weight asbestos structures from heavier matrix particles and deposit these structures onto a filter which can then be analysed by TEM (with EDS and SAED) or another appropriate microscopy method. Details of the FBS method are presented in Januch et al. (2013) and EPA (2018). In brief, soil samples are thoroughly dried, sieved to remove larger particles, combined 1:20 – 3:20 with laboratory-grade sand, and air is drawn through the sample/sand mixture while the mixture is vibrated mechanically. Fractions of the airborne particles are collected on mixed cellulose ester (MCE) or polycarbonate filters and analyzed by TEM or SEM. The air filter is typically analyzed by TEM for asbestos in basic accordance with the recording rules specified in method
PE standards consisting of uncontaminated Arvada, Colorado, soil containing either fibrous Libby amphibole structures, amosite asbestos, or chrysotile asbestos at concentrations of 0.01%, 0.005%, 0.001% and 0.0005% by weight. This 2015 study illustrates an approximate linear relationship between the nominal concentration of asbestos in the PE standard and the concentration estimated by TEM analysis expressed as asbestos structures per gram of test material (s/g). The method detection limits of each in this study fell within 0.002% to 0.003% by weight. In a study by Berry et al. (2019), uncontaminated Arvada, Colorado, soil was spiked with 0.0001–0.1% erionite from Rome, Oregon. The authors also tested two field samples (Dunn
County, North Dakota; Custer National Forest, Montana) that were taken from areas where erionite is present in soils. The samples were elutriated using the FBAS method, and samples were analysed by TEM following ISO 10312 protocol. The authors demonstrated a linearity (r2 The EPA Air Emission Measurement Center (EMC) publishes a list of new methods which have not yet been subject to the Federal rulemaking process in an “Other Test Method” document (OTM; EPA 2018). December 2021 of 0.93 for group means) between 0.001–0.1% spiked samples. The authors noted a minimum detection limit of 0.003% for FBAS+TEM when the probability of detection of erionite on sample filters is set at 80%. To date, however, there have been no published studies investigating the use of the FBAS method for determining the asbestos content in talc. Talc presents some unique problems that are not present in soils, such as, (a) the similarity of density (g/cm3) for talc and some asbestos amphibole minerals, and (b) the fine particle size of cosmetic talc. 6. Heavy Liquid Separation (HLS) of Minerals
Hussak, The Determination of Rock-forming Minerals. pp.73-75. 1896]. Clerici’s solution: aqueous solution of equal parts of thallium formate (CAS 992-98-3) and thallium malonate (CAS 2757-18-8). A saturated solution (500 g each salt in 100 mL water) has density of 4.28 g/cm3 at 20 oC (4.25 g/cm3 at 15 oC) [Clerici, E. 1907. Preparazione di liquidi per la separazione dei minerali. Atti. R.A. Lincei, Rome. 16, 187-195; Vassar H.E. 1925. Clerici solution for mineral separation by gravity. American Mineralogist 10(5), 123-125; https://www.mindat.org/glossary/Clerici_solution]. Partial list of companies conducting HLS analysis: https://www.chem.com.au/heavy_liquid.html; https://www.heavyliquids.com/techdata.html; https://www.alsglobal.com/en-us/services-and-products/metallurgy/explorationand-brownfields-studies/heavy-liquid-separation; https://sites.google.com/site/concentrationofminerals/home. December 2021
MSDS sheet for thallium malonate indicates same toxicities as thallium formate (http://www.acros.com/Ecommerce/msds.aspx?Language=en&PrdNr=42079). Thallium compound toxicity; https://cfpub.epa.gov/ncea/iris/iris_documents/documents/toxreviews/1012tr.pdf ; https://rais.ornl.gov/tox/profiles/thallium_f_V1.html. Bromoform toxicity profiled at https://19january2017snapshot.epa.gov/sites/production/files/201609/documents/bromoform.pdf. Methylene iodide toxicity; https://www.fishersci.com/store/msds?partNumber=AC169830250&productDescription=DIIODOMETHANE%2C +99%2B%25+25GR&vendorId=VN00032119&countryCode=US&language=en. Tetrabromoethane toxicity; http://datasheets.scbt.com/sc-237646.pdf. December 2021 heteropolytungstate; 44,45 and sodium polytungstate (H2Na6O40W12; CAS 12141-67-2). 46 7. Heavy Liquid Separation of Asbestos from Other Minerals
Apparently, the talc industry was aware in the early-1970s of the possible application of HLS for isolating and concentrating asbestos from talc samples as a method of improving analytical sensitivity. The Johnson & Johnson Company contracted F.D. Pooley (University of Cardiff,
Wales, UK) in 1973 to conduct an evaluation of the use of HLS to separate amphibole minerals that may be present in talc (Johnson & Johnson, 1973). Pooley’s publication describes HLS technique using a mixture of 1,1,2,2-tetrabromoethane (CAS 79-27-6; 2.97 g/cm3 at 20 oC) and toluene (CAS 108-88-3; 0.87 g/cm3 at 20 oC) in a 17:1 mixture to achieve density of 2.83 g/cm3 at 25 oC or at a 7:1 mixture to achieve a density of 2.68 g/cm3 at 25 oC. The minerals were collected on glass fiber filters after centrifugation. Although no details of analysis were provided, the publication provided indication of the effectiveness of the separation.
Bagioni (1975) also described the separation of asbestos from other minerals using HLS techniques with organic fluids of specified densities. Samples of mixtures of amphibole, talc, serpentine and phyllite were suspended in 3 mL of 1,1,2,2-tetrabromoethane:carbon tetrachloride 47 (35:15; density 2.45-2.50 g/mL at 20oC), quantitatively transferred with 2 mL of the 1,1,2,2-tetrabromoethane:carbon tetrachloride (35:15) solution, and centrifuged at 2000-2500 rpm. 48 The authors stated the asbestos minerals were collected by filtration through 0.45 μm Millipore filters (type HA). The collected asbestos fibers were then detected using infrared spectrum analysis of the -OH bond stretch at 3670 cm-1. The ability of this method to separate and concentrate the asbestos fibers was clearly demonstrated. Haartz et al. (1978) used bromoform (CAS 75-25-2; 2.89 g/cm3) and tetrabromoethane (CAS 7927-6; 2.97 g/cm3) for HLS separation of tremolite, cummingtonite and grunerite from quartz,
TALC 14807-96-6 2.58-2.83 http://www.handbookofmineralogy.org/pdfs/talc.pdf Anthophyllite 77536-67-5 2.9-3.5 http://www.handbookofmineralogy.org/pdfs/anthophyllite.pdf Anthophyllite 77536-67-5 2.85-3.57 https://www.mindat.org/min-8738.html Anthophyllite 77536-67-5 2.98-3.22 Blount (1991), Tröger (1979) Tremolite 77536-68-6 2.99-3.03 http://www.handbookofmineralogy.org/pdfs/tremolite.pdf Actinolite 77536-66-4 3.03-3.24 http://www.handbookofmineralogy.org/pdfs/actinolite.pdf ; https://www.mindat.org/min-18.html
ILO International Chemical Safety Cards (ICSC); http://www.ilo.org/dyn/icsc/showcard.display?p_version=2&p_ card_id=0014 https://en.wikipedia.org/wiki/Chrysotile Many sources were consulted regarding the density of asbestos minerals and talc. The range of results from multiple data sources may provide the reader a sense of the consistency (or inconsistency) of the available information. Neither the inclusion of a particular source of information, nor the order of presentation, should be considered endorsement of the data source. December 2021
Toland (2000) describes in detail an HLS process for the determination of asbestos in vermiculite or vermiculite-containing products using aqueous sedimentation, and centrifugation in solutions of either 1,1,2,2-tetrabromoethane (CAS 79-27-6; 2.96 g/cm3) or tribromomethane (bromoform;
Toland (2000) included detailed description of the sedimentation velocities for various mineral sizes and length of centrifugation required to achieve equilibrium. The International Standards Organization (ISO) describes methods for detecting and quantifying asbestos minerals in bulk materials in ISO 22262-2:2014, including detailed sections on a method for sample preparation by separation/concentration. In section 15.4 of the ISO standard,
IT 325 and Nytal 100) in lithium metatungstate (2.95 g/cm3) (Halterman (2017) as a follow-up to the work of Tomaino (2016). The author concluded that HLS analysis of talc using lithium metatungstate is promising, but that further research is required regarding the reliability of this method for detecting non-talc fractions of less than 1% from talc-based consumer products. W. Longo testified to a U.S. House Subcommittee 55 that the use of HLS successfully isolates asbestos particles from talc, allowing greater sensitivity. 56 He additionally noted that HLS is not effective for concentration of chrysotile from talc due to similar densities. As a result of these publications and presentations, it appears that both the mineral analytical industry and materials testing societies (e.g., ASTM) are aware of the use of HLS for isolating and possibly concentrating asbestos from other minerals, including talc, for quantitative analysis. The IWGACP notes there is a lack of published inter-laboratory qualitative and quantitative studies on the application of HLS to low-levels of asbestos in talc and talc-containing cosmetics.
DISCUSSION OF HLS The IWGACP notes that HLS should be strongly considered as a candidate method in interlaboratory studies for concentrating asbestos minerals from talc and talc-containing cosmetics. It 2016 Michael E. Beard Conference, https://www.astm.org/MEETINGS/SYMPOSIAPROGRAMS/D22ID2782.pdf. 2017 ASTM Johnson Conference, https://www.astm.org/MEETINGS/SYMPOSIAPROGRAMS/D22ID3216.pdf Hearing of the House Committee on Oversight and Reform, Subcommittee on Economic and Consumer Policy (11 Dec 2019). https://oversight.house.gov/legislation/hearings/examining-carcinogens-in-talc-and-the-best-methods-forasbestos-detection. December 2021 is of particular concern that HLS is not able to separate chrysotile from talc because both minerals have similar densities.
IWGACP analysis of the literature points out two critical shortcomings of HLS to isolate and detect low-levels of asbestos in talc and talc-containing cosmetics: (1) The acceptance of the HLS technique for quantitative isolation of low levels of asbestos from talc requires inter-laboratory research to: (a) determine the reproducibility and accuracy of the method; (b) the effect of asbestos and other mineral particle size (length, width) on the recoveries from talc. (2) Talc standards (talc with specific levels of asbestos of known homogeneity, concentration, size, aspect ratio) do not exist and would be required for inter-laboratory comparisons of results using this method. Rohl and Langer (1974) described a process to generate standards with specific populations of asbestos minerals in talc; however, there are no commercially available talc-asbestos standards with specific asbestos minerals at concentrations below 1%. 8. References
ASTM C123/C123M. 2012. Standard test method for lightweight particles in aggregate. ASTM International. www.astm.org
Bagioni, R.P. 1975. Separation of chrysotile asbestos from minerals that interfere with its infrared analysis. Environmental Science & Technology 9(3):262-263.
Berry D, Januch J, Woodbury L, Kent D. 2019. Detection of Erionite and Other Zeolite Fibers in Soil by the Fluidized Bed Preparation Methodology. The Microscope; Vol. 64:4, pp 147-158.
Blount, A.M. 1991. Amphibole content of cosmetic and pharmaceutical talcs. Environmental Health Perspectives 94:225-230.
Chisholm, E.-K., Sircombe, K., and DiBugnara, D. 2014. Handbook of Geochronology Mineral Separation Laboratory Techniques. Australian Government, Geoscience Australia, Record 2014/46. (ISBN: 978-1-925124-39-2) .
Cyphert, J.M., Padilla-Carlin, D.J., Schladweiler, M.C., Shannahan, J.H., Nyska, A., Kodavanti, U.P. and Gavett, S.H. 2012. Long-Term Response of Rats to Single Intratracheal Exposure of Libby Amphibole or Amosite. Journal of Toxicology and Environmental Health, Part A 75(3);183-200.
Kodavanti, U.P. and Gavett, S.H. 2015. Comparative Long-Term Toxicity of Libby Amphibole December 2021 and Amosite Asbestos in Rats After Single or Multiple Intratracheal Exposures. Journal of Toxicology and Environmental Health, Part A 78(3):151-165.