Dow Chemical Company (2005) Dow Water & Process Solutions FILMTECTM Reverse Osmosis Membranes Technical Manual. Technical Manual
Other documents for the same rulemaking (all, by stage)
References: 22 extracted, 0 linked to papers
ASTM D 4195 – 88 (Reapproved 2003): Standard Guide for Water Analysis for Reverse Osmosis Application Water Quality and Treatment, 5th Edition, Prepared by the American Water Works Association, McGraw-Hill, Inc., New
York, 1999 Water Treatment Handbook, Degremont Company, 6th Ed 1991 Water Manual, WABAG, 2nd Ed. (2003)
ASTM D3739-94 (2003): Standard Practice for Calculation and Adjustment of the Langelier Saturation Index for Reverse Osmosis
ASTM D4582-91 (2001): Standard Practice for Calculation and Adjustment of the Stiff and Davis Stability Index for Reverse Osmosis
Marshall, W.L. and Slusher, R., “Solubility to 200°C of Sulfate and its Hydrates in Sea Water and Saline Water Concentrates and Temperature, Concentration Limits,” Journal of Chemical and Engineering Data, 13(1), 83 (1968)
10. Davis, J.W. and Collins, A.G., “Solubility of Barium and Strontium Sulfates in Strong Electrolyte Solutions,” Environmental Science and Technology, 5(10), 1039 (1971) 11. Permasep B-10 Technical Information Manual, Section IV Projections, E. I. du Pont de Nemours & Co. 1980
12. Vorum, M. and Williams, R.E., “A Study of Silica in High Recovery Reverse Osmosis Systems”, PB81-233587 (1979) 13. L. Dudley, “Combating the Threat of Silica Fouling in RO Plant – Practical Experiences”, Desalination & Water Reuse, 12(4), 28 (2003) 14. S.I. Graham, R.L. Reiz, and C.E. Hickman, “Improving Reverse Osmosis Performance though Periodic Cleaning”,
Desalination, 74, 113 (1989) 15. M. Luo and Z. Wang, “Complex Fouling and Cleaning-in-Place of a Reverse Osmosis Desalination System”,
ASTM D4993-89 (2003): Standard Practice for Calculation and Adjustment of Silica (SiO 2 ) Scaling for Reverse Osmosis
17. Alexander, G.B., Hester, W.M., Iler, R.K., “The Solubility of Amorphous Silica in Water”, Journal of Physical Chemistry, 58, 453 (1954) 18. M. Maurer and M. Boller, “Modelling of Phosphorus Precipitation in Wastewater Treatment Plants with Enhanced Biological Phosphorus Removal”, Wat. Sci. Tech, 39(1), 147 (1999) 19. S. Kubo, T. Takahashi, H. Morinaga, and H. Ueki, “Inhibition of Calcium Phosphate Scale on Heat Exchanger: The Relation between Laboratory Test Results and Tests on Heat Transfer Surfaces”, Corrosion’79, Paper No. 220, Atlanta (1979) 20. D1889 /ASTM D1889-00 Standard Test Method for Turbidity of Water
ASTM D4189-95 (2002): Standard Test Method for Silt Density Index (SDI) of Water
23. Schippers, J.C. and Verdouw, J.: The modified fouling index, a method of determining the fouling characteristics of water, Desalination 32, 137 (1980)
24. Boerlage, S.F.E., Kennedy, M, Aniye, M.P. and Schippers, J.C.: Applications of the MFI-UF to measure and predict particulate fouling in RO systems, J. Membrane Sci. 220, 97 (2003)
25. ASTM D4188-82 (Reapproved 1999): Standard Practice for Performing Pressure In-Line Coagulation-FlocculationFiltration Test Page 68 of 181 ™® Trademark of The Dow Chemical Company ("Dow") or an affiliated company of Dow Form No. 609-00071-0416 26. Handbook of Industrial Membrane Technology, Ed.: Porter, M.C., Noyes Publications, Park Ridge, New Jersey, U.S.A. (1990) 27. D4455-85(2002): Standard Test Method for Enumeration of Aquatic Bacteria by Epifluorescence Microscopy Counting Procedure 28. D4454-85(2002) Standard Test Method for Simultaneous Enumeration of Total and Respiring Bacteria in Aquatic Systems by Microscopy 29. J.S. Vrouwenvelder and D. van der Kooij, Diagnosis, prediction and prevention of biofouling of NF and RO membranes,
Desalination, 139, 65 (2001) 30. MM Nederlof, JC Kruithof, JAMH Hofman, M de Koning, JP van der Hoek, PAC Bonne, Integrated multi-objective membrane systems application of reverse osmosis at the Amsterdam Water Supply, Desalination, 119, 263 (1998) 31.
In Press (2003) 32. D. van der Kooij, H.R. Veenendaal, C. Baars-Lorist, D.W. van der Klift and Y.C. Drost: Biofilm formation on surfaces of glass and teflon exposed to treated water. Wat.Res., 29(7)(1995) 1655-1662
34. White, G.C.: Handbook of Chlorination. Van Nostrand Reinhold Co., New York (2nd ed., 1986) 35. M. Nagai, H. Iwahashi, Y. Hayashi, and Y. Ogino, “The Behavior of an Oxidizing/Reducing Agent in Seawater”,
Youngberg, D.A.: Start-up of an RO/DI Pure Water System. Ultrapure Water, March/April 1986, 46-50.
ASTM D4472-89 (Reapproved 2003): Standard Guide for Record Keeping for Reverse Osmosis Systems.
ASTM D4195-88 (Reapproved 2003): Standard Guide for Water Analysis for Reverse Osmosis Application.
Walton, V.R.G.: Electrical Conductivity and Total Dissolved Solids – What is Their Precise Relationship? Desalination, 72 (1989) 275-292. Page 120 of 181 ™® Trademark of The Dow Chemical Company ("Dow") or an affiliated company of Dow Form No. 609-00071-0416 Cleaning and Sanitization Introduction The surface of a reverse osmosis (RO) membrane is subject to fouling by foreign materials that may be present in the feed water, such as hydrates of metal oxides, calcium precipitates, organics and biological matter. The term “fouling” includes the build-up of all kinds of layers on the membrane surface, including scaling. Pretreatment of the feed water prior to the RO process is basically designed to reduce contamination of the membrane surfaces as much as possible. This is accomplished by installing an adequate pretreatment system and selecting optimum operating conditions, such as permeate flowrate, pressure and permeate water recovery ratio.
ASTM D3923-94(2003)e1 Standard Practices for Detecting Leaks in Reverse Osmosis Devices