{"document":{"doc_id":138665,"source":"docket_item","org":"EERE","doc_type":"analysis","title":"2017-10  Technical Support Document (Energy Savings Analysis)","date":"2018-02-21","url":"https://www.regulations.gov/document/EERE-2017-BT-DET-0046-0006","source_native_id":"EERE-2017-BT-DET-0046-0006","status":"fetched","abstract":null,"action":null},"dockets":["EERE-2017-BT-DET-0046"],"rins":["RIN 1904-AE14","FR 2018-03931"],"related":[{"doc_id":232616,"source":"docket_item","org":"EERE","doc_type":"other","title":"2017-07-25  Preliminary Analysis Regarding Energy Efficiency Improvements in ANSI/ASHRAE/IES Standard 90.1-2016: Energy Standard for Buildings, Except Low-Rise Residential Buildings; Notice of availability","date":"2017-07-25"},{"doc_id":311207,"source":"docket_item","org":"EERE","doc_type":"other","title":"2018-02-27  Final Determination Regarding Energy Efficiency Improvements in ANSI/ASHRAE/IES Standard 90.1-2016:  Energy Standard for Buildings, Except Low-Rise Residential Buildings; Notice of order","date":"2018-02-27"},{"doc_id":137076,"source":"fr_rule","org":"DEPARTMENT OF ENERGY","doc_type":"Notice","title":"Final Determination Regarding Energy Efficiency Improvements in ANSI/ASHRAE/IES Standard 90.1-2016: Energy Standard for Buildings, Except Low-Rise Residential Buildings","date":"2018-02-27"},{"doc_id":138664,"source":"docket_item","org":"EERE","doc_type":"review_record","title":"Documentation of Changes between the draft Final Determination submitted to the Office of Information and Regulatory Affairs (OIRA) and the issued Final Determination","date":"2018-03-15"}],"references":[{"citation_id":880534,"raw_reference":"ASHRAE. 2013a. ANSI/ASHRAE/IES Standard 90.1-2013. Energy Standard for Buildings Except Low-Rise Residential Buildings. American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Atlanta, Georgia. Read-only version available at https://ashrae.iwrapper.com/ViewOnline/Standard_90.1-2013_I-P.","cited_authors":"ASHRAE","cited_year":"2013a","cited_title":"ANSI/ASHRAE/IES Standard 90.1-2013","cited_venue":null,"cited_doi":null,"cited_url":"https://ashrae.iwrapper.com/ViewOnline/Standard_90.1-2013_I-P","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":880535,"raw_reference":"ASHRAE. 2013b. ANSI/ASHRAE Standard 169-2013. Climatic Data for Building Design Standards. American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Atlanta, Georgia. Relevant information available as Annex 1 in ASHRAE 2016b.","cited_authors":"ASHRAE","cited_year":"2013b","cited_title":"ANSI/ASHRAE Standard 169-2013","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":880536,"raw_reference":"ASHRAE. 2016a. ANSI/ASHRAE/IES Standard 90.1-2016. Energy Standard for Buildings Except Low-Rise Residential Buildings. American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Atlanta, Georgia. Read-only version available at https://ashrae.iwrapper.com/ViewOnline/Standard_90.1-2016_(IP).","cited_authors":"ASHRAE","cited_year":"2016a","cited_title":"ANSI/ASHRAE/IES Standard 90.1-2016","cited_venue":null,"cited_doi":null,"cited_url":"https://ashrae.iwrapper.com/ViewOnline/Standard_90.1-2016_(IP","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":880537,"raw_reference":"ASHRAE. 2016b. Standards Addenda. American Society of Heating, Refrigerating, and Air-Conditioning","cited_authors":"ASHRAE","cited_year":"2016b","cited_title":"Standards Addenda","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":880538,"raw_reference":"Athalye RA, Z Taylor, and B Liu. 2016. Impact of ASHRAE Standard 169-2013 on Building Energy Codes and Energy Efficiency. Building Performance Modeling Conference 2016. Salt Lake City, UT. Available at https://www.ashrae.org/File%20Library/docLib/Events/Simbuild2016/Papers/C057.pdf.","cited_authors":"Athalye RA, Z Taylor, and B Liu","cited_year":"2016","cited_title":"Impact of ASHRAE Standard 169-2013 on Building Energy Codes and Energy Efficiency","cited_venue":null,"cited_doi":null,"cited_url":"https://www.ashrae.org/File%20Library/docLib/Events/Simbuild2016/Papers/C057.pdf","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":880539,"raw_reference":"DOE. 2013. Energy Plus Energy Simulation Software, Version 8.0. U.S. Department of Energy, Washington, D.C. Available at http://apps1.eere.energy.gov/buildings/EnergyPlus/.","cited_authors":"DOE","cited_year":"2013","cited_title":"Energy Plus Energy Simulation Software, Version 8.0","cited_venue":null,"cited_doi":null,"cited_url":"http://apps1.eere.energy.gov/buildings/EnergyPlus/","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":880540,"raw_reference":"ECPA. Energy Conservation and Production Act of 1976. Public Law 94-385. Available at http://www.gpo.gov/fdsys/pkg/STATUTE-90/pdf/STATUTE-90-Pg1125.pdf.","cited_authors":"ECPA. Energy Conservation and Production Act of","cited_year":"1976","cited_title":"Public Law 94-385","cited_venue":null,"cited_doi":null,"cited_url":"http://www.gpo.gov/fdsys/pkg/STATUTE-90/pdf/STATUTE-90-Pg1125.pdf","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":880541,"raw_reference":"EIA. 2003. Commercial Buildings Energy Consumption Survey 2003. Energy Information Administration of U.S. Department of Energy, Washington, D.C. Available at http://www.eia.doe.gov/emeu/cbecs/contents.html.","cited_authors":"EIA","cited_year":"2003","cited_title":"Commercial Buildings Energy Consumption Survey 2003","cited_venue":null,"cited_doi":null,"cited_url":"http://www.eia.doe.gov/emeu/cbecs/contents.html","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":880542,"raw_reference":"Goel S, M Rosenberg, R Athalye, Y Xie, W Wang, R Hart, J Zhang, and V Mendon. 2014. Enhancements to","cited_authors":"Goel S, M Rosenberg, R Athalye, Y Xie, W Wang, R Hart, J Zhang, and V Mendon","cited_year":"2014","cited_title":"Enhancements to","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":880543,"raw_reference":"Gowri K, M Halverson, and E Richman. 2007. Analysis of Energy Saving Impacts of ASHRAE 90.1-2004 for New York. PNNL-16770, Pacific Northwest National Laboratory, Richland, Washington. Available at http://www.pnl.gov/main/publications/external/technical_reports/PNNL-16770.pdf.","cited_authors":"Gowri K, M Halverson, and E Richman","cited_year":"2007","cited_title":"Analysis of Energy Saving Impacts of ASHRAE 90.1-2004 for New York","cited_venue":null,"cited_doi":null,"cited_url":"http://www.pnl.gov/main/publications/external/technical_reports/PNNL-16770.pdf","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":880544,"raw_reference":"Halverson M, R Athalye, M Rosenberg, Y Xie, W Wang, R Hart, J Zhang, S Goel, and V Mendon. 2014.","cited_authors":"Halverson M, R Athalye, M Rosenberg, Y Xie, W Wang, R Hart, J Zhang, S Goel, and V Mendon","cited_year":"2014","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":880545,"raw_reference":"ANSI/ASHRAE/IES Standard 90.1-2013 Determination of Energy Savings: Quantitative Analysis. PNNL23481, Pacific Northwest National Laboratory, Richland, Washington. Jarnagin RE and GK Bandyopadhyay. 2010. Weighting Factors for the Commercial Prototype buildings Used in the Development of ANSI/ASHRAE/IENSA Standard 90.1-2010. PNNL-19116, Pacific Northwest National","cited_authors":"ANSI/ASHRAE/IES Standard 90.1-2013 Determination of Energy Savings: Quantitative Analysis. PNNL23481, Pacific Northwest National Laboratory, Richland, Washington. Jarnagin RE and GK Bandyopadhyay","cited_year":"2010","cited_title":"Weighting Factors for the Commercial Prototype buildings Used in the Development of ANSI/ASHRAE/IENSA Standard 90.1-2010","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":880546,"raw_reference":"FINAL ENERGY SAVINGS ANALYSIS ANSI/ASHRAE/IES STANDARD 90.1-2016","cited_authors":null,"cited_year":null,"cited_title":"FINAL ENERGY SAVINGS ANALYSIS ANSI/ASHRAE/IES STANDARD 90.1-2016","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":880547,"raw_reference":"Thornton BA, W Wang, H Cho, Y Xie, V Mendon, E Richman, J Zhang, R Athalye, M Rosenberg, and B Liu. 2011. Achieving 30% Goal: Energy and Cost Saving Analysis of ASHRAE/IES Standard 90.1-2010. Pacific Northwest National Laboratory, Richland, Washington. Available at http://www.energycodes.gov/publications/research/documents/codes/PNNL-20405.pdf. References Interagency Working Comments on Draft Language under EO 12866 and EO 13563 Interagency Review. Subject to Further Policy Review.","cited_authors":"Thornton BA, W Wang, H Cho, Y Xie, V Mendon, E Richman, J Zhang, R Athalye, M Rosenberg, and B Liu","cited_year":"2011","cited_title":"Achieving 30% Goal: Energy and Cost Saving Analysis of ASHRAE/IES Standard 90.1-2010","cited_venue":null,"cited_doi":null,"cited_url":"http://www.energycodes.gov/publications/research/documents/codes/PNNL-20405.pdf","ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":880548,"raw_reference":"FINAL ENERGY SAVINGS ANALYSIS ANSI/ASHRAE/IES STANDARD 90.1-2016 Appendix A: Addenda Not Quantified in Energy Savings Analysis Addendum Sections Affected Description of Change Discussion Specifies combined maximum voltage drop of 5% instead of separate voltage drops for branch (3%) and feeder (2%) circuits. Cumulative voltage drop remains the same. Table 6.5.3.1-2 Clarifies interpretation of the equation used for pressure drop adjustment calculation for energy recovery devices. Clarification only. C3.5.8 Modifies the language in Appendix C to separate fan power from the cooling and heating efficiency calculation. Change applies to an alternative compliance path and does not affect prescriptive or mandatory requirements. Table G3.1 Requires opaque assemblies in the baseline building to match the descriptions in Appendix Change applies to an alternative compliance path and does not affect prescriptive or mandatory requirements. 10.4.1 Adds text on electric motors to identify the tables that must be followed based on size and type (Tables 10.8-4 and 10.8-5). Clarification only. 6.4.4.2.1 Clarifies the wording regarding duct seal class by removing text to avoid misinterpretation. Clarification only. Table 6.8.1-7","cited_authors":null,"cited_year":null,"cited_title":"FINAL ENERGY SAVINGS ANALYSIS ANSI/ASHRAE/IES STANDARD 90.1-2016 Appendix A: Addenda Not Quantified in Energy Savings Analysis Addendum Sections Affected Description of Change Discussion Specifies combined maximum voltage drop of 5% instead of separate voltage drops for branch (3%) and feeder (2%) circuits","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":880549,"raw_reference":"ASHRAE 2013a. ANSI/ASHRAE Standard 169-2013. Climatic Data for Building Design Standards. American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Atlanta, Georgia. Relevant information available as Annex 1 in ASHRAE 2016.","cited_authors":"ASHRAE","cited_year":"2013a","cited_title":"ANSI/ASHRAE Standard 169-2013","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":880550,"raw_reference":"ASHRAE 2013b. ANSI/ASHRAE Standard 62.1-2013. Ventilation for Acceptable Indoor Air Quality. American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Atlanta, Georgia.","cited_authors":"ASHRAE","cited_year":"2013b","cited_title":"ANSI/ASHRAE Standard 62.1-2013","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":880551,"raw_reference":"ASHRAE 2016. ANSI/ASHRAE/IES Standard 90.1-2016. Energy Standard for Buildings Except Low-Rise Residential Buildings. American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Atlanta, Georgia. Read-only version available at https://ashrae.iwrapper.com/ViewOnline/Standard_90.1-2016_(IP).","cited_authors":"ASHRAE","cited_year":"2016","cited_title":"ANSI/ASHRAE/IES Standard 90.1-2016","cited_venue":null,"cited_doi":null,"cited_url":"https://ashrae.iwrapper.com/ViewOnline/Standard_90.1-2016_(IP","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":880552,"raw_reference":"Gifford W, ML Goldberg, PM Tanimoto, DR Celnicker, and ME Poplawski. 2012. Residential Lighting EndUse Consumption Study: Estimation Framework and Initial Estimates. Fairfax, VA. Available at https://www1.eere.energy.gov/buildings/publications/pdfs/ssl/2012_residential-lighting-study.pdf","cited_authors":"Gifford W, ML Goldberg, PM Tanimoto, DR Celnicker, and ME Poplawski","cited_year":"2012","cited_title":"Residential Lighting EndUse Consumption Study: Estimation Framework and Initial Estimates","cited_venue":null,"cited_doi":null,"cited_url":"https://www1.eere.energy.gov/buildings/publications/pdfs/ssl/2012_residential-lighting-study.pdf","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":880553,"raw_reference":"LBNL. 2016. Berkeley Lab Window. Lawrence Berkeley National Laboratory, Berkeley, California. Accessed at: https://windows.lbl.gov/software/window/window.html. McCourt R and KG Hooper. 2010. Parking Generation, 4th ed. Institute of Transportation Engineers,","cited_authors":"LBNL","cited_year":"2016","cited_title":"Berkeley Lab Window","cited_venue":null,"cited_doi":null,"cited_url":"https://windows.lbl.gov/software/window/window.html","ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":880554,"raw_reference":"Washington, D.C. McGowan A. 2006. “Heat Transfer Through Roll-up Doors, Revolving Doors and Opaque Nonresidential","cited_authors":"Washington, D.C. McGowan A","cited_year":"2006","cited_title":"“Heat Transfer Through Roll-up Doors, Revolving Doors and Opaque Nonresidential","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":880555,"raw_reference":"Richman EE, E Rauch, J Knappek, J Phillips, K Petty, and P Lopez-Rangel. 2008. “National Commercial Construction Characteristics and Compliance with Building Energy Codes: 1999-2007.” 2008 ACEEE Summer Study on Energy Efficiency in Buildings, ACEEE Publications, Washington D.C.","cited_authors":"Richman EE, E Rauch, J Knappek, J Phillips, K Petty, and P Lopez-Rangel","cited_year":"2008","cited_title":"National Commercial Construction Characteristics and Compliance with Building Energy Codes: 1999-2007","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":880556,"raw_reference":"Thornton BA, W Wang, H Cho, Y Xie, V Mendon, E Richman, J Zhang, R Athalye, M Rosenberg, and B Liu. 2011. Achieving 30% Goal: Energy and Cost Saving Analysis of ASHRAE/IES Standard 90.1-2010. Pacific Northwest National Laboratory, Richland, Washington. Available at http://www.energycodes.gov/publications/research/documents/codes/PNNL-20405.pdf. B.16 Appendix B Interagency Working Comments on Draft Language under EO 12866 and EO 13563 Interagency Review. Subject to Further Policy Review. (This page intentionally left blank) For more information, visit: energy.gov/eere/buildings","cited_authors":"Thornton BA, W Wang, H Cho, Y Xie, V Mendon, E Richman, J Zhang, R Athalye, M Rosenberg, and B Liu","cited_year":"2011","cited_title":"Achieving 30% Goal: Energy and Cost Saving Analysis of ASHRAE/IES Standard 90.1-2010","cited_venue":null,"cited_doi":null,"cited_url":"http://www.energycodes.gov/publications/research/documents/codes/PNNL-20405.pdf","ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null}]}