Policy Replication

Energy Conservation Program for Certain Industrial Equipment: Energy Conservation Standards and Test Procedures for Commercial Heating, Air-Conditioning, and Water-Heating Equipment

Federal Register2012-05-16 · DEPARTMENT OF ENERGY · Rule · 2012-10650
Final rule.

The U.S. Department of Energy (DOE) is amending its energy conservation standards for small, large, and very large water-cooled and evaporatively-cooled commercial package air conditioners, and variable refrigerant flow (VRF) water-source heat pumps less than 17,000 Btu/h. DOE is adopting new energy conservation standards for computer room air conditioners and VRF water-source heat pumps with a cooling capacity at or greater than 135,000 Btu/h and less than 760,000 Btu/h. Pursuant to the Energy Policy and Conservation Act of 1975 (EPCA), as amended, DOE must assess whether the uniform national standards for these covered equipment need to be updated each time the corresponding industry standard--the American National Standards Institute (ANSI)/American Society of Heating, Refrigerating, and Air- Conditioning Engineers (ASHRAE)/Illuminating Engineering Society of North America (IESNA) Standard 90.1 (ASHRAE Standard 90.1)--is amended, which most recently occurred on October 29, 2010. The levels DOE is adopting are the same as the efficiency levels specified in ASHRAE Standard 90.1-2010. DOE has determined that the ASHRAE Standard 90.1- 2010 efficiency levels for the equipment types listed above are more stringent than existing Federal energy conservation standards and will result in economic and energy savings compared existing energy conservation standards. Furthermore, DOE has concluded that clear and convincing evidence does not exist, as would justify more-stringent standard levels than the efficiency levels in ASHRAE Standard 90.1-2010 for any of the equipment classes. DOE is also updating the current Federal test procedures or, for certain equipment, adopting new test procedures to incorporate by reference the most current versions of the relevant industry test procedures specified in ASHRAE Standard 90.1- 2010. Furthermore, DOE is adopting additional test procedure provisions to include with modification certain instructions from Air- Conditioning, Heating, and Refrigeration Institute (AHRI) operations manuals in that organization's test procedures that would clarify the application of the DOE test procedures and harmonize DOE testing with the testing performed by industry.

RIN 1904-AC47 · Docket EERE-2011-BT-STD-0029

Other documents for the same rulemaking

2011-05-05 Federal RegisterEnergy Conservation Program for Certain Industrial Equipment: Energy Conservation Standards for Commercial Heating, Air-Conditioning, and Water-Heating Equipment
2011-05-05 Regulatory impact analysis2011-05-02 Notice of Data Availabillity Technical Support Document
2012-01-17 Federal RegisterEnergy Conservation Program for Certain Industrial Equipment: Energy Conservation Standards and Test Procedures for Commercial Heating, Air-Conditioning, and Water-Heating Equipment
2012-03-13 Regulatory impact analysis2012-02-14 Technical Support Document
2012-03-22 Federal RegisterEnergy Conservation Program for Certain Industrial Equipment: Energy Conservation Standards and Test Procedures for Commercial Heating, Air-Conditioning, and Water-Heating Equipment
2012-07-20 Regulatory impact analysisCommercial Heating, Air Conditioning, and Water Heating Equipment (i.e., ASHRAE Equipment) Final Rule Rulemaking Technical Support Document
2015-03-05 Federal RegisterEnergy Conservation Program for Certain Industrial Equipment: Energy Conservation Standards and Test Procedures for Commercial Heating, Air-Conditioning, and Water-Heating Equipment; Correction

References: 21 extracted, 3 linked to papers

Page 1Download these results: CSV · JSON
EnergyConsult Pty Ltd., Equipment Energy Efficiency Committee Regulatory Impact Statement Consultation Draft: Minimum Energy Performance Standards and Alternative Strategies for Close Control Air Conditioners, Report No 2008/11 (2008) (Available at: www.energyrating.gov.au).
research reportNot linked to a paper · fn 16
U.S. Department of Energy-Office of Energy Efficiency and Renewable Energy. EnergyPlus Documentation, Engineering Reference (Available at: http://apps1.eere.energy.gov/buildings/energyplus/pdfs/engineeringreference.pdf).
government reportNot linked to a paper · fn 17 · cited link
S. Wilcox and W. Marion, Users Manual for TMY3 Data Sets, National Renewable Energy Laboratory: Golden, CO., Report No. NREL/TP-581-43156 (2008).
DOE estimated the annual energy consumption for each equipment class at each efficiency level for 239 climate locations using typical meteorological year (TMY3) weather data.\18\ DOE relied on population-based climate location weights to map the results for individual TMY locations to State-level annual energy consumption estimates for each U.S.
Damodaran Online, The Data Page (Last Accessed Jan. 2012) (Available at: www.stern.nyu.edu/~adamodar/New_Home_Page/data.html).
datasetNot linked to a paper · fn 20
RS Means Company Inc., RS Means CostWorks 2011 (2011) (Available at: www.meanscostworks.com/).
datasetNot linked to a paper · fn 21
RS Means Company, Inc., RS Means CostWorks 2012 (2012) (Available at: www.meanscostworks.com/).
datasetNot linked to a paper · fn 22
U.S. Energy Information Administration, Electric Sales, Revenue, and Average Price 2009 (Last accessed May 10, 2011).
datasetNot linked to a paper · fn 23
U.S. Energy Information Administration, Annual Energy Outlook 2011.
datasetNot linked to a paper · fn 24 · cited link
U.S. Energy Information Administration, Sales and Revenue Data by State, Monthly Back to 1990 (Form EIA-826) (Last accessed Jan. 27, 2012).
datasetNot linked to a paper · fn 25 · cited link
U.S. Energy Information Administration, CBECS Public Use Microdata Files (Last Accessed April 2012).
datasetNot linked to a paper · fn 30
Federal Reserve Bank of St. Louis, State and Local Bonds-Bond Buyer Go 20-Bond Municipal Bond Index (Last accessed April 6, 2012).
datasetNot linked to a paper · fn 33 · cited link
National Research Council, Hidden Costs of Energy: Unpriced Consequences of Energy Production and Use, National Academies Press: Washington, DC (2009).
A recent report from the National Research Council \39\ points out that any assessment will suffer from uncertainty, speculation, and lack of information about: (1) Future emissions of greenhouse gases; (2) the effects of past and future emissions on the climate system; (3) the impact of changes in climate on the physical and biological environment; and (4) the translation of these environmental impacts into economic damages.
S. Wilcox and W. Marion, Users Manual for TMY3 Data Sets
DOE estimated the annual energy consumption for each equipment class at each efficiency level for 239 climate locations using typical meteorological year (TMY3) weather data.\18\ DOE relied on population-based climate location weights to map the results for individual TMY locations to State-level annual energy consumption estimates for each U.S.
Air-Conditioning, Heating, and Refrigeration Institute Standard 210/240-2008 (AHRI 210/240-2008), "Performance Rating of Unitary Air-Conditioning & Air-Source Heat Pump Equipment"
otherNot linked to a paper · Supplementary Information · cited link
Air-Conditioning, Heating, and Refrigeration Institute Standard 340/360-2007 (AHRI 340/360-2007), "Performance Rating of Commercial and Industrial Unitary Air-Conditioning and Heat Pump Equipment"
otherNot linked to a paper · Supplementary Information · cited link
Air-Conditioning, Heating, and Refrigeration Institute Standard 1230-2010 (AHRI 1230-2010), "Performance Rating of Variable Refrigerant Flow (VRF) Multi-Split Air-Conditioning and Heat Pump Equipment"
otherNot linked to a paper · Supplementary Information · cited link
American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) Standard 127-2007, "Method of Testing for Rating Computer and Data Processing Room Unitary Air Conditioners"
otherNot linked to a paper · Supplementary Information · cited link
Underwriters Laboratories, Inc. Standard 727-2006 (UL 727-2006), "Standard for Safety for Oil-Fired Central Furnaces"
otherNot linked to a paper · Supplementary Information · cited link
American National Standards Institute Z21.47-2006 (ANSI Z21.47-2006), "Gas-Fired Central Furnaces"
otherNot linked to a paper · Supplementary Information · cited link
American National Standards Institute Z21.10.3-2011, (ANSI Z21.10.3-2011), "Gas Water Heaters, Volume III, Storage Water Heaters With Input Ratings Above 75,000 Btu Per Hour, Circulating and Instantaneous"
otherNot linked to a paper · Supplementary Information · cited link
Air-Conditioning, Heating, and Refrigeration Institute Standard 390-2003 (AHRI 390-2003), "Performance Rating of Single Package Vertical Air-Conditioners and Heat Pumps"
otherNot linked to a paper · Supplementary Information · cited link