Policy Replication

Requirements for Blood and Blood Components Intended for Transfusion or for Further Manufacturing Use

Federal Register2015-05-22 · DEPARTMENT OF HEALTH AND HUMAN SERVICES; Food and Drug Administration · Rule · 2015-12228
Final rule.

The Food and Drug Administration (FDA) is amending the regulations applicable to blood and blood components, including Source Plasma, to make the donor eligibility and testing requirements more consistent with current practices in the blood industry, to more closely align the regulations with current FDA recommendations, and to provide flexibility to accommodate advancing technology. In order to better assure the safety of the nation's blood supply and to help protect donor health, FDA is revising the requirements for blood establishments to test donors for infectious disease, and to determine that donors are eligible to donate and that donations are suitable for transfusion or further manufacture. FDA is also requiring establishments to evaluate donors for factors that may adversely affect the safety, purity, and potency of blood and blood components or the health of a donor during the donation process. Accordingly, these regulations establish requirements for donor education, donor history, and donor testing. These regulations also implement a flexible framework to help both FDA and industry to more effectively respond to new or emerging infectious agents that may affect blood product safety.

RIN 0910-AG87 · Docket FDA-2006-N-0040

Other documents for the same rulemaking

2007-11-13 Docket documentDraft Regulatory Action for Review to OMB and OIRA re: Requirements for Human Blood and Blood Components Intended for Transfusion or for Further Manufacturing Use Part 1 of 2
2007-11-13 Docket documentDraft Regulatory Action for Review to OMB and OIRA re: Requirements for Human Blood and Blood Components Intended for Transfusion or for Further Manufacturing Use Part 2 of 2
2015-05-22 Regulatory impact analysisReference 77 Regulatory Impact Analysis re Requirements for Blood and Blood Components Intended for Transfusion or for Further Manufacturing Use
2015-05-22 Regulatory impact analysisReference 77-11 Regulatory Impact Analysis Prevalence, incidence, and residual risk of human immunodeficiency virus and hepatitis C virus infections re Requirements for Blood and Blood Components Intended for Transfusion or for Further Manufacturing Use

References: 35 extracted, 27 linked to papers

Page 1Download these results: CSV · JSON
2011 National Blood Collection and Utilization Survey Report
research reportNot linked to a paper · fn 1
Stramer, S. L., F. B. Hollinger, L. Katz, et al., “Emerging Infectious Disease Agents and Their Potential Threat to Transfusion Safety,” Transfusion, August 2009; 49:1S-29S.
Stramer, S. L. and R. Y. Dodd, “Transfusion-Transmitted Emerging Infectious Diseases: 30 Years of Challenges and Progress,” Transfusion, October 2013, 53:2375-2383.
Dumont, L. J., S. Kleinman, J. R. Murphy, et al., “Screening of Single-Donor Apheresis Platelets for Bacterial Contamination: The PASSPORT Study Results,” Transfusion, March 2010; 50:589-599.
Jacobs, M. R., C. E. Good, H. M. Lazarus, et al., “Relationship Between Bacterial Load, Species Virulence, and Transfusion Reaction with Transfusion of Bacterially Contaminated Platelets,” Clinical Infectious Disease, 2008; 46:1214-1220.
Eder, A. F. and M. Goldman, “How Do I Investigate Septic Transfusion Reactions and Blood Donors with Culture-Positive Platelet Donations?” Transfusion, August 2011; 51:1662-1668.
Domen, R. E., I. D. Grewal, N. V. Hirschler, et al., “An Evaluation of the Need for Shared Blood Donor Deferral Registries,” International Journal for Quality in Health Care, 1997; 9:35-41.
Ellis, F. R., L. I. Friedman, B. F. Wirak, et al., “A Computerized National Blood Donor Deferral Register,” The Journal of the American Medical Association, 1975; 232(7):722-724.
Trouern-Trend, J. J., R. G. Cable, S. J. Badon, et al., “A Case-Controlled Multicenter Study of Vasovagal Reactions in Blood Donors: Influence of Sex, Age, Donation Status, Weight, Blood Pressure, and Pulse,” Transfusion, March 1999; 39:316-320.
Wiltbank, T. B., G. F. Giordano, H. Kamel, et al., “Faint and Prefaint Reactions in Whole-Blood Donors: An Analysis of Predonation Measurements and Their Predictive Value,” Transfusion, September 2008; 48:1799-1808.
Cable, R. G., W. R. Steele, R. S. Melmed, et al., “The Difference Between Fingerstick and Venous Hemoglobin and Hematocrit Varies by Sex and Iron Stores,” Transfusion, May 2012; 52:1031-1040.
Cable, R. G., S. A. Glynn, J. E. Kiss, et al., “Iron Deficiency in Blood Donors: the REDS-II Donor Iron Status Evaluation (RISE) Study,” Transfusion, April 2012; 52:702-711.
Tan, L., M. K. Khan, and J. C. Hawk III, “Use of Blood Therapeutically Drawn From Hemochromatosis Patients,” Transfusion, September 1999; 39:1018-1026.
Jeffrey, G. and P. C. Adams, “Blood from Patients with Hereditary Hemochromatosis-a Wasted Resource?” Transfusion, June 1999; 39:549-550.
Shaz, B. H., D. A. Kessler, C. A. Hillyer, et al., “Evaluating the Role of Blood Collection Centers in Public Health: A Status Report,” Transfusion Medicine Reviews, January 2012; 26:58-67.
Laub, R., S. Baurin, D. Timmerman, et al., “Specific Protein Content of Pools of Plasma for Fractionation from Different Sources: Impact of Frequency of Donations,” Vox Sanguinis, October 2010; 99:220-231.
Katz, L., K. Palmer, E. McDonnell, et al., “Frequent Plateletpheresis Does Not Clinically Significantly Decrease Platelet Counts in Donors,” Transfusion, September 2007; 47:1601-1606.
Lazarus, E. F., J. Browning, J. Norman, et al., “Sustained Decreases in Platelet Count Associated with Multiple, Regular Plateletpheresis Donations,” Transfusion, June 2001; 41:756-761.
Page, E. A., J. E. Coppock, and J. F. Harrsion, “Study of Iron Stores in Regular Plateletphereis Donors,” Transfusion Medicine, February 2010; 20:22-29.
Macher, S., S. Sipurzynski-Budraβ, K. Rosskopf, et al., “Influence of Multicomponent Apheresis on Donors' Haematological and Coagulation Parameters, Iron Storage and Platelet Function,” Vox Sanguinis, October 2012; 103:194-200.
Laubach, J., P. Richardson, and K. Anderson, “Multiple Myeloma,” Annual Reviews of Medicine, February 2011; 62:249-264.
journal articleMultiple Myeloma (2010) · References, ref 61
Lewis, S. L., S. G. Kutvirt, P. N. Bonner, et al., “Plasma Proteins and Lymphocyte Phenotypes in Long-Term Plasma Donors,” Transfusion, July 1994; 34:578-585.
Ortel, T. L., “Antiphospholipid Syndrome: Laboratory Testing and Diagnostic Strategies,” American Journal of Hematology, 2012; 87:S75-S81.
Gold, J. S., S. Bayar, and R. R. Salem, “Association of Streptococcus bovis Bacteremia with Colonic Neoplasia and Extracolonic Malignancy,” Archives of Surgery, 2004; 139(7):760-765.
Bai, N., “Donor Fatigue. The Red Cross Has Banned Chronic Fatigue Syndrome Sufferers from Giving Blood. But Does a Virus Really Cause the Disease?” Scientific American, July 2011; 305(1):26.
newsNot linked to a paper · References, ref 32
Young, S., A. Fink, S. Geiger, et al., “Community Blood Donors' Knowledge of Anemia and Design of a Literacy-Appropriate Educational Intervention,” Transfusion, January 2010; 50:75-79.
Weber, J. P., P. C. Walsh, C. A. Peters, et al., “Effect of Reversible Androgen Deprivation on Hemoglobin and Serum Immunoreactive Erythropoietin in Men,” American Journal of Hematology, March 1991; 36:190-194.
Yomtovian, R. A. and M. Brecher, “pH and Glucose Testing of Single-Donor Apheresis Platelets Should be Discontinued in Favor of a More Sensitive Detection Method,” Transfusion 2005; 4:646-648.
Guidance for Industry and FDA Review Staff: Collection of Platelets by Automated Methods, dated December 2007
government reportNot linked to a paper · Executive Summary
AABB, formerly the American Association of Blood Banks, published an article in 2009 identifying 68 emerging infectious disease agents that are potentially transmitted by blood (Ref. 4)
journal articleNot linked to a paper · Section I. Introduction
Bacterial contamination is estimated to occur in as many as 1/1,000 to 1/3,000 platelet collections (Refs. 12, 13).
otherNot linked to a paper · Section D. Control of Bacterial Contamination of Platelets (§ 606.145)
"Iron deficiency in blood donors: The REDS-II Donor Iron Status Evaluation (RISE) Study," (Ref. 50).
In a 1998 report, the General Accounting Office (GAO) compared the incidence rates (positives per 100,000 person years) between paid and volunteer plasma donors
government reportNot linked to a paper · Comment 119 (Qualified Donor Standard and Inventory Hold)
Plasma Protein Therapeutics Association, Quality Standards of Excellence, Assurance and Leadership (QSEAL) Certification Program (Ref. 74).
otherNot linked to a paper · Comment 119 (Qualified Donor Standard and Inventory Hold)
In a United Kingdom study of serum ferritin levels of frequent plateletpheresis donors, there was a direct correlation between plateletpheresis donation frequency and iron depletion. (Ref. 68).
journal articleNot linked to a paper · Comment 114