{"document":{"doc_id":10431,"source":"fr_rule","org":"DEPARTMENT OF ENERGY","doc_type":"Rule","title":"Energy Conservation Program: Energy Conservation Standards for Single Package Vertical Air Conditioners and Single Package Vertical Heat Pumps","date":"2015-09-23","url":"https://www.federalregister.gov/documents/2015/09/23/2015-23029/energy-conservation-program-energy-conservation-standards-for-single-package-vertical-air","source_native_id":"2015-23029","status":"fetched","abstract":"The Energy Policy and Conservation Act of 1975 (EPCA), as amended, prescribes energy conservation standards for various consumer products and certain commercial and industrial equipment, including single package vertical air conditioner (SPVAC) and single package vertical heat pump (SPVHP) equipment (collectively referred to as single package vertical units or SPVUs). EPCA also requires the U.S. Department of Energy (DOE) to determine whether more-stringent standards for SPVACs and SPVHPs would be technologically feasible and economically justified, and would save a significant amount of energy. In this final rule, DOE is adopting standards equivalent to the American National Standards Institute (ANSI)/American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)/ Illuminating Engineering Society (IES) Standard 90.1-2013 levels for four SPVU equipment classes, and adopting amended energy conservation standards for two other equipment classes of single package vertical units more stringent than the SPVU standards in ASHRAE Standard 90.1- 2013. DOE has determined that the amended energy conservation standards for this equipment are technologically feasible and economically justified, and would result in the significant conservation of energy.","action":"Final rule."},"dockets":["EERE-2012-BT-STD-0041"],"rins":["RIN 1904-AC85"],"related":[{"doc_id":10710,"source":"ria","org":"EERE","doc_type":"technical_support_document","title":"2014-12  Technical Support Document: Energy Efficiency Program for Commercial and Industrial Equipment: Single Package Vertical Units. (NOPR)","date":"2014-12-12"},{"doc_id":11073,"source":"fr_rule","org":"DEPARTMENT OF ENERGY","doc_type":"Proposed Rule","title":"Energy Conservation Program for Certain Industrial Equipment: Energy Conservation Standards for Single Package Vertical Air Conditioners and Single Package Vertical Heat Pumps","date":"2014-12-30"},{"doc_id":130830,"source":"docket_item","org":"EERE","doc_type":"review_record","title":"Documentation of Changes between the draft NOPR submitted to the Office of Information and Regulatory Affairs (OIRA) and the issued NOPR.","date":"2015-01-05"},{"doc_id":10707,"source":"ria","org":"EERE","doc_type":"technical_support_document","title":"2015-08  Final Rule Technical Support Document:  Energy Efficiency Program for Commercial and Industrial Equipment:  Single Package Vertical Units","date":"2015-09-02"},{"doc_id":23195,"source":"ria","org":"DEPARTMENT OF ENERGY","doc_type":"regulatory_impact_analysis","title":"RIA cited in FR 2015-23029: Energy Conservation Program: Energy Conservation Standards for Single Package Vertical Air Conditioners and Single Package Vertical Heat Pumps","date":"2015-09-23"},{"doc_id":23057,"source":"ria","org":"Federal Motor Carrier Safety Administration","doc_type":"regulatory_impact_analysis","title":"RIA cited in FR 2016-20934: Federal Motor Vehicle Safety Standards; Federal Motor Carrier Safety Regulations; Parts and Accessories Necessary for Safe Operation; Speed Limiting Devices","date":"2016-09-07"},{"doc_id":22979,"source":"ria","org":"DEPARTMENT OF ENERGY","doc_type":"regulatory_impact_analysis","title":"RIA cited in FR 2017-14079: Energy Conservation Program: Energy Conservation Standards for Walk-In Cooler and Freezer Refrigeration Systems","date":"2017-07-10"},{"doc_id":22982,"source":"ria","org":"DEPARTMENT OF ENERGY","doc_type":"regulatory_impact_analysis","title":"RIA cited in FR 2017-14079: Energy Conservation Program: Energy Conservation Standards for Walk-In Cooler and Freezer Refrigeration Systems","date":"2017-07-10"},{"doc_id":22683,"source":"ria","org":"DEPARTMENT OF ENERGY","doc_type":"regulatory_impact_analysis","title":"RIA cited in FR 2019-26350: Energy Conservation Program: Energy Conservation Standards for Portable Air Conditioners","date":"2020-01-10"}],"references":[{"citation_id":60245,"raw_reference":"Deru, M., et al., U.S. Department of Energy Commercial Reference Building Models of the National Building Stock, NREL/TP-5500-46861 (2011).","cited_authors":"Deru, M., et al.","cited_year":"2011","cited_title":"U.S. Department of Energy Commercial Reference Building Models of the National Building Stock","cited_venue":"National Renewable Energy Laboratory, NREL/TP-5500-46861","cited_doi":"10.2172/1009264","cited_url":null,"ref_kind":"research_report","section":"fn 38","page":null,"context_sentence":"Operating schedules, internal load profiles, internal electric receptacle (plug) loads, and occupancy for the modular classroom were those from classroom-space-type data found in the DOE Primary School commercial prototype building model.\\38\\ Operating schedules, internal load profiles, internal plug loads, and occupancy for modular office buildings were those from office space in the DOE Small Office commercial prototype building model.","paper_id":15333,"paper_title":"U.S. Department of Energy Commercial Reference Building Models of the National Building Stock","paper_year":2011,"paper_doi":"10.2172/1009264"},{"citation_id":60246,"raw_reference":"EnergyConsult Pty Ltd., Equipment Energy Efficiency Committee Regulatory Impact Statement Consultation Draft: Minimum Energy Performance Standards and Alternative Strategies for Close Control Air Conditioners, Report No 2008/11 (2008)","cited_authors":"EnergyConsult Pty Ltd.","cited_year":"2008","cited_title":"Equipment Energy Efficiency Committee Regulatory Impact Statement Consultation Draft: Minimum Energy Performance Standards and Alternative Strategies for Close Control Air Conditioners","cited_venue":"Report No 2008/11","cited_doi":null,"cited_url":"www.energyrating.gov.au","ref_kind":"research_report","section":"fn 39","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":60247,"raw_reference":"Wilcox S. and W. Marion, User's Manual for TMY3 Data Sets, National Renewable Energy Laboratory, Report No. NREL/TP-581-43156 (2008).","cited_authors":"Wilcox S.; Marion, W.","cited_year":"2008","cited_title":"User's Manual for TMY3 Data Sets","cited_venue":"National Renewable Energy Laboratory, NREL/TP-581-43156","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"fn 45","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":60248,"raw_reference":"Jacobson, MZ (2005), “Correction to `Control of fossil-fuel particulate black carbon and organic matter, possibly the most effective method of slowing global warming,' ” J. Geophys. Res. 110. pp. D14105.","cited_authors":"Jacobson, MZ","cited_year":"2005","cited_title":"Correction to Control of fossil-fuel particulate black carbon and organic matter, possibly the most effective method of slowing global warming","cited_venue":"J. Geophys. Res. 110","cited_doi":"10.1029/2005jd005888","cited_url":null,"ref_kind":"journal_article","section":"fn 16","page":null,"context_sentence":"Because CO2 emissions have a very long residence time in the atmosphere,\\16\\ the SCC values in future years reflect future CO2-emissions impacts that continue beyond 2100. ---------------------------------------------------------------------------","paper_id":6872,"paper_title":"Correction to “Control of fossil‐fuel particulate black carbon and organic matter, possibly the most effective method of slowing global warming”","paper_year":2005,"paper_doi":"10.1029/2005jd005888"},{"citation_id":60249,"raw_reference":"Technical Update of the Social Cost of Carbon for Regulatory Impact Analysis Under Executive Order 12866. Interagency Working Group on Social Cost of Carbon, United States Government. May 2013; revised July 2015.","cited_authors":"Interagency Working Group on Social Cost of Carbon","cited_year":"2015","cited_title":"Technical Update of the Social Cost of Carbon for Regulatory Impact Analysis Under Executive Order 12866","cited_venue":"United States Government","cited_doi":null,"cited_url":"https://www.whitehouse.gov/sites/default/files/omb/inforeg/scc-tsd-final-july-2015.pdf","ref_kind":"government_report","section":"fn 13","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":60250,"raw_reference":"Heating, Air-conditioning & Refrigeration Distributors International (HARDI), 2013 Profit Report (2012 Data)","cited_authors":"Heating, Air-conditioning & Refrigeration Distributors International (HARDI)","cited_year":"2013","cited_title":"2013 Profit Report (2012 Data)","cited_venue":"HARDI","cited_doi":null,"cited_url":"http://www.hardinet.org/Profit-Report","ref_kind":"research_report","section":"fn 26","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":60251,"raw_reference":"Damodaran Online (Last accessed Feb. 14, 2014)","cited_authors":"Damodaran, A.","cited_year":"2014","cited_title":"Damodaran Online","cited_venue":"New York University Stern School of Business","cited_doi":null,"cited_url":"http://pages.stern.nyu.edu/~adamodar/New_Home_Page/home.htm","ref_kind":"dataset","section":"fn 48","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":60252,"raw_reference":"RS Means CostWorks 2014, R.S. Means Company, Inc. (2013)","cited_authors":"R.S. Means Company, Inc.","cited_year":"2013","cited_title":"RS Means CostWorks 2014","cited_venue":"R.S. Means Company, Inc.","cited_doi":null,"cited_url":"www.meanscostworks.com/","ref_kind":"dataset","section":"fn 49","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":60253,"raw_reference":"U.S. Energy Information Administration. Annual Energy Outlook 2015 (2015) DOE/EIA-0383(2015).","cited_authors":"U.S. Energy Information Administration","cited_year":"2015","cited_title":"Annual Energy Outlook 2015","cited_venue":"DOE/EIA-0383(2015)","cited_doi":null,"cited_url":"http://www.eia.gov/forecasts/aeo/data.cfm","ref_kind":"research_report","section":"fn 51","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":60254,"raw_reference":"ASHRAE Handbook: 2011 Heating, Ventilating, and Air-Conditioning Applications (2011).","cited_authors":"ASHRAE","cited_year":"2011","cited_title":"ASHRAE Handbook: 2011 Heating, Ventilating, and Air-Conditioning Applications","cited_venue":"ASHRAE","cited_doi":null,"cited_url":null,"ref_kind":"book","section":"fn 53","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":61314,"raw_reference":"Abramson, Interactive Web-based Owning and Operating Cost Database, Final Report ASHRAE Research Project RP-1237 (2005).","cited_authors":"Abramson","cited_year":"2005","cited_title":"Interactive Web-based Owning and Operating Cost Database, Final Report ASHRAE Research Project RP-1237","cited_venue":"ASHRAE","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"Introduction (preceding section a. Equipment Prices), fn 55","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":61315,"raw_reference":"Energy Efficient Strategies Pty Ltd., Equipment Energy Efficiency Committee Regulatory Impact Statement Consultation Draft. Revision to the Energy Labelling Algorithms and Revised MEPS levels and Other Requirements for Air Conditioners, Report No 2008/09 (September 2008)","cited_authors":"Energy Efficient Strategies Pty Ltd.","cited_year":"2008","cited_title":"Equipment Energy Efficiency Committee Regulatory Impact Statement Consultation Draft. Revision to the Energy Labelling Algorithms and Revised MEPS levels and Other Requirements for Air Conditioners, Report No 2008/09","cited_venue":"Equipment Energy Efficiency Committee","cited_doi":null,"cited_url":"http://www.energyrating.gov.au/wp-content/uploads/Energy_Rating_Documents/Library/Cooling/Air_Conditioners/200809-ris-ac.pdf","ref_kind":"research_report","section":"Introduction (preceding section a. Equipment Prices)","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":61316,"raw_reference":"Energy Information Administration, Commercial Building Energy Consumption Survey 2003, CBECS Public Use Microdata Files","cited_authors":"Energy Information Administration","cited_year":"2003","cited_title":"Commercial Building Energy Consumption Survey 2003, CBECS Public Use Microdata Files","cited_venue":"EIA","cited_doi":null,"cited_url":"http://www.eia.gov/emeu/cbecs/cbecs2003/public_use_2003/cbecs_pudata2003.html","ref_kind":"dataset","section":"d. Electricity and Natural Gas Prices, fn 58","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":61317,"raw_reference":"Modular Building Institute, State of the Industry 2006","cited_authors":"Modular Building Institute","cited_year":"2006","cited_title":"State of the Industry 2006","cited_venue":"Modular Building Institute","cited_doi":null,"cited_url":"http://www.modular.org/HtmlPage.aspx?name=analysis","ref_kind":"research_report","section":"h. Discount Rate, fn 62","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":61318,"raw_reference":"Modular Building Institute, Commercial Modular Construction Report 2008","cited_authors":"Modular Building Institute","cited_year":"2008","cited_title":"Commercial Modular Construction Report 2008","cited_venue":"Modular Building Institute","cited_doi":null,"cited_url":"http://www.modular.org/HtmlPage.aspx?name=analysis","ref_kind":"research_report","section":"h. Discount Rate, fn 63","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":61319,"raw_reference":"Modular Building Institute, Commercial Modular Construction Report 2009","cited_authors":"Modular Building Institute","cited_year":"2009","cited_title":"Commercial Modular Construction Report 2009","cited_venue":"Modular Building Institute","cited_doi":null,"cited_url":"http://www.modular.org/HtmlPage.aspx?name=analysis","ref_kind":"research_report","section":"h. Discount Rate, fn 64","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":61320,"raw_reference":"Modular Building Institute, Relocatable Buildings 2011 Annual Report","cited_authors":"Modular Building Institute","cited_year":"2011","cited_title":"Relocatable Buildings 2011 Annual Report","cited_venue":"Modular Building Institute","cited_doi":null,"cited_url":"http://www.modular.org/HtmlPage.aspx?name=analysis","ref_kind":"research_report","section":"h. Discount Rate, fn 65","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":61321,"raw_reference":"M. J. Scott, O. V. Livingston, P. J. Balducci, J. M. Roop, and R. W. Schultz, ImSET 3.1: Impact of Sector Energy Technologies, PNNL-18412, Pacific Northwest National Laboratory (2009)","cited_authors":"M. J. Scott, O. V. Livingston, P. J. Balducci, J. M. Roop, R. W. Schultz","cited_year":"2009","cited_title":"ImSET 3.1: Impact of Sector Energy Technologies","cited_venue":"Pacific Northwest National Laboratory","cited_doi":null,"cited_url":"www.pnl.gov/main/publications/external/technical_reports/PNNL-18412.pdf","ref_kind":"research_report","section":"M. Employment Impact Analysis, fn 96","page":null,"context_sentence":null,"paper_id":15669,"paper_title":"ImSET 3.1: Impact of Sector Energy Technologies Model Description and User's Guide","paper_year":2009,"paper_doi":"10.2172/962848"},{"citation_id":61322,"raw_reference":"National Research Council, Hidden Costs of Energy: Unpriced Consequences of Energy Production and Use, National Academies Press: Washington, DC (2009).","cited_authors":"National Research Council","cited_year":"2009","cited_title":"Hidden Costs of Energy: Unpriced Consequences of Energy Production and Use","cited_venue":"National Academies Press","cited_doi":"10.17226/12794","cited_url":null,"ref_kind":"book","section":"K.1.a Monetizing Carbon Dioxide Emissions, fn 88","page":null,"context_sentence":null,"paper_id":6873,"paper_title":"Hidden Costs of Energy: Unpriced Consequences of Energy Production and Use","paper_year":2010,"paper_doi":"10.17226/12794"},{"citation_id":61323,"raw_reference":"Jacobson, MZ, “Correction to `Control of fossil-fuel particulate black carbon and organic matter, possibly the most effective method of slowing global warming,' ” J. Geophys. Res. 110. pp. D14105 (2005).","cited_authors":"Jacobson, M.Z.","cited_year":"2005","cited_title":"Correction to Control of fossil-fuel particulate black carbon and organic matter, possibly the most effective method of slowing global warming","cited_venue":"J. Geophys. Res.","cited_doi":"10.1029/2005jd005888","cited_url":null,"ref_kind":"journal_article","section":"Section C Conclusions, fn 102","page":null,"context_sentence":null,"paper_id":6872,"paper_title":"Correction to “Control of fossil‐fuel particulate black carbon and organic matter, possibly the most effective method of slowing global warming”","paper_year":2005,"paper_doi":"10.1029/2005jd005888"},{"citation_id":61324,"raw_reference":"Morningstar, Inc., Ibbotson SBBI 2013 Classic Yearbook. Market Results for Stocks, Bonds, Bills, and Inflation 1926-2012 (2013).","cited_authors":"Morningstar, Inc.","cited_year":"2013","cited_title":"Ibbotson SBBI 2013 Classic Yearbook. Market Results for Stocks, Bonds, Bills, and Inflation 1926-2012","cited_venue":"Morningstar, Inc.","cited_doi":null,"cited_url":null,"ref_kind":"book","section":"H. Consumer Subgroup Analysis, fn 76","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null}]}